Advantages & Features



Similar documents
GSM Alarm System User Manual

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

In The Worldwide! GSM Elderly Care Alarm Telecare & Telehealth System. User Manual. An Advanced Programmable Multifunctional Elderly Care Alarm

GSM ALARM SYSTEM USER MANUAL

Intelligent GSM Auto-dial Alarm System User s Manual

GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: All rights reserved by King Pigeon Hi-Tech. Co., Ltd.

Security module CG2 User manual

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

Intelligent GSM Auto-Dial Alarm System

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

DC-8706K Auto Dial Alarm System

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

S100. GSM House Alarm System.

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

MOBILE CALL GSM Alarm System User s Manual

Business/Home GSM Alarm System. Installation and User Manual

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

Iphone & Android App Smart GSM Home Alarm System

Quick Installation Guide LCD GSM ALARM SYSTEM LH

GSM Elderly Guarder. User Manual. Ver 1.1 Date Issued: All rights reserved by Shenzhen Daiya Electronic Technology Co., Ltd.

Six-defense zone Display Alarm System. User Manual

STATUS POWER MONITOR ALARM SOS DISARM

SECURITY SYSTEM MANUAL

GSM Elderly Guarder User Manual Ver 1.0 X-TRON

GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.1 Date Issued: All rights reserved by King Pigeon Hi-Tech. Co., Ltd.

GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Home Alarm System User s Manual. Home Alarm System User Manual

GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE. Please read it carefully before installation and operation

MOBILE CALL GSM alarm system

Home Security Alarm System

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Business/Home GSM. Alarm System(III) Installation and Users guide

Business/ Home GSM Alarm System

Business/Home. GSM Alarm system

GSM home alarm system s manual

GSM House Alarm System. S110 User Manual. Ver 1.00 Date Issued:

Security GSM Alarm System

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Users Manual of GSM Home Alarm System with Photo-taken

Wireless Auto-dial Intruder Alarm System

GPS Vehicle and personal location tracker. User manual

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Wireless Alarm system s manual

Ademco Vista-20P/First Alert FA-168C Basic Commands

Intruder Alarm System

Intelligent Alarm System

GSM HOME SECURITY SYSTEM

GSM Security Alarm GSM Senior Telecare. In The Worldwide! User Manual. An Advanced Programmable Multifunctional GSM Alarm Panel GSM Senior Telecare

Wireless Home Security System Product Manual (Model #80355)

GE Concord 4 Quick User Guide

GE Simon XT Quick User Guide

GSM Alarm. An Advanced Programmable Multifunctional GSM Auto Dialer GSM Alarm Panel In The Worldwide! User Manual. S100Pro. Ver 1.

tattletale User Guide Consumer unit version P a g e

An Advanced Programmable Multifunctional GSM Auto-Dialer GSM Alarm Panel In The Worldwide!

Safe Health Guarder User Manual

Residential & Commercial Alarm Systems by Gross Security, LLC

Security System Owner s Manual

Destiny Destiny Owners Manual

CAD-05 Kit GSM Auto Dialer. Owner s Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

PhoneWatch Smart Security System User Manual - Domonial

Using your LED Plus keypad

WITURA CORPORATION SDN BHD

PiSector Home security systems

Temperature & Humidity SMS Alert Controller

GUIDE GETTING STARTED IMPORTANT SUPPORT RESOURCES

SECTION DETECTION AND ALARM

GSM Gate Opener GSM Remote Switch

Welcome to Bell Aliant NextGen Home Security

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

CCTR-805-V2 3G Car GPS Tracker

Auto Dialer. Manual E-921APQ E-921GPQ

An Advanced Programmable Multifunctional GSM Auto Dialer GSM Alarm Panel In The Worldwide!

PiSector GSM Cellular Wireless Alarm System

User s Information Guide R1A

GC2 Panel User Guide

SMS GSM Alarm Messenger

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

How To Program An Autodialer

Business/Home GSM Alarm systems. Installation and User Manual

MAGICAR M871A. Car alarm with two-way remote User s guide

GSM SMS IR CONTROLLER

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

IDS X-Series User Manual D Issued July 2012

COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT600i GPRS PANEL

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

ABUS WIRELESS ALARM SYSTEM

DESTINY OWNER S MANUAL

The A10 GSM Elderly Guarder is a very innovative concept of GSM Panic Alarm, GSM

PiSector Land Line Auto Dial Professional Wireless Alarm System

EM8610 e-alarm GSM Alarm System Starter Kit

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Security System. User Guide for the LED Command Center

Transcription:

Advantages & Features 2G/3G mobile frequency enable K9 works great in worldwide. GSM/3G Wireless Security Alarm System 99 zones for security intrusion alarm, elderly care, SOS help, 7*24 hours safety, door bell, on site alarm applications. 10 different zone types and zone name editable. Multiple status optional: Stay, Away, Bypass, Schedule Arm/Disarm. User friendly menu with more than 12 languages selectable. Visible information on big LCD screen, easy setting and operation by touch keypad. K9 Two way voice communications, regular phone call as hand set supported. 2 wireless switch channel for remote control & door access (*works with WS1,WS2). Just simply dial in to the K9, change the status to Arm / Stay / Disarm by missed call, or create two way talk automatically. Monitoring zone for take care of elderly daily life activities. Temperature monitoring alarm. 1. Basic Setting Wireless sensors battery low power alarm SMS. 2. Edit Zones 3. Advance Settings Backup rechargeable battery inside, AC power lost alert available. Audible alarm inside, support wireless siren too. Ademco Contact ID protocol over GPRS/UMTS/HSDPA data supported. Fashion design of sleek panel with a classic elegant piano finish. Easy DIY--Smart phone APP for remote configuration & operation. Up to 999 alarm event logs and 99 operation logs for review. All rights reserved King Pigeon. www.gsmalarmsystem.com

How the system works for your family? How the system works for your family? Security Protection Press to arm the system when leaving home. Press to arm the system when at home. 7* 24 hours Home Safety Guard When smoke, gas, CO or water flood detected, system makes audible alarm, send alert SMS text and call to the alarm receivers/call center/firefighting or other CMS system. SOS Alarm & Call Press SOS button more than 3 seconds to make SOS Call. System dial the 1st receiver number and then next numbers if no answering, totally repeat twice, and SOS alert SMS send to receivers at same time for asking SOS help. Other Wireless SOS button or fall detectors optional. Make Phone Call Dial phone number and then press Call button to start talk, when alert receiver s phone call in, you can press call button to answer and talk. You can also press Call button to end the talk. Elderly Daily Life Care System sends alert SMS text if no activities detected by the 5th zone's PIR/Door sensor during the monitoring time period. For example, install one wireless door sensor at your Dad's bed room, setting the monitoring time period as 05:30~09:00 am, if he didn't get up (didn't open his door) during that time, system sends alert SMS to the you says Monitor Zone Alarm ---you can edit this SMS text for sure. You will receive SMS text only for this event, no calls or audible alarm. Door Bell Install and connect one door bell button to the system, setting the zone function as 10. Door bell, when someone push the button, system makes 6 bell sound. Temperature Monitoring System sends alert SMS text to you when indoor temperature too hot or too cold. Other Living Care System sends alert SMS text to you when AC/DC power lost (default: more than 30 minutes) and recovery, and when the wireless sensor's battery low power(if have). Remote Control Connect with the alarm interlock relay, system will switch on/off your equipments automatically when alarm triggered. Open the Door Press 0 1 and Key button to open your door (*if you have installed the WS1 wireless switch on your electronic lock). Call in to control Connect with the WS2 wireless switch, you can remote switch on/off your equipments by phone call. 1 2

Control Panel Layout Key Buttons LCD Display Setting Menu Touch Keypad Away Arm Button Stay Arm Button 1. Basic Setting 2. Edit Zones 3. Advance Settings All the sensors are Armed except the sensors in Inner zones which disarmed so that users can move freely at home. Disarm Button Press Disarm button and 4 digits password (default: 1234), and press the system after two beeps. to disarm SOS Button Key Back/Delete Stay Home Up Away Arm Left SOS Down Alarm indicator-- Flash Red lights: alarm Disarm Right Menu Enter/OK/ Call/End Press the SOS button more than 2 seconds to make SOS alarm. Call Button Dial phone number and then press Call button to start talk or answer phone call in. You can also press the Call button to end talk. Microphone Key Button Arm indicator-- Green: Stay Home Arm Red: Away Arm Off: Disarm Press and Key button to open your door (*if you have installed the WS1 wireless switch on your electronic lock). 3 4

Bottom View Wiring Connections Mount Socket Speaker Terminal cover Tamper Switch Temperature Sensor Reset button Power Switch Wired Zone 1/2 SIM Card Slot Alarm Interlock Relay Output + - DIN1 DIN2 NC COM NO Screw hole Mounting Bracket Install the bracket on the wall by using screws, after wiring connection and power on, plug the socket to the bracket tightly, make the tamper switch close. When plug out the socket, tamper switch will make alarm. IP Camera Alarm Output 1A 2B Door sensor L N Light 100~240V AC 5 6

Easy Setting by Keypad Basic Settings Start: Put the mobile SIM Card to the slot. Connect the power supply, Switch ON. On Setup mode, below buttons used for: Menu, Enter, OK 1. View 2. Setup 1. Basic Setting 2. Edit Zones 3. Advance Settings Select Language Back, Exit Left, Delete Right 1. English 2. Espanol 3. Deutsch 4. Pyccknn 5. Italiano 6. Dansk 7. Cestina 8. Francais 9. Bahasa Up If you changed menu language, you should reset the system and reboot again. Caution: All settings and sensors are lost after reset except language. Setup Date & Time Down Reset: Open the SIM Card cover, press and hold the Reset button. Switch ON. After 5 seconds, release the Reset button, LCD display Reset OK, system back to factory mode. 7 8 Setup Time 06-23-15 10: 33: 26 Month-Day-Year

Setup Alert Number (Alarm Receiver) Temperature Alarm Threshold 01. Empty Input Tel Number 008613510150873 1. High:99 2. Low:99 High: +99 1. Total 9 Alert receiver numbers. 2. Country code issue: If you can't received the alert SMS or call, please try to change the country code as 0086, 86 or just remove the country code on front of your phone number. 99 means disable the temperature alarm function. Up/Down button to adjust + and -. Left/Right button to select number position. Receiver's phone number can be programming to below major functions: Function code 1 (alarm notify method): 1. receive SMS and call when alarm. 2. receive SMS only when alarm. 3. receive call only when alarm. Function code 2 (when this number call to system): 1. system changes status from Away Arm to Stay Arm. 2. system answers the call automatically. 3. system needs to press Call button to answer the call in. 1. Send SMS&Call 2. Only Send SMS 3. Only Call 1. Call to Armed/Stay 2. Call to Talk 3. Call to Wait Answer Arm Sound Notification Armed Alert by Sound No Yes No: Silent when Arm the system. Yes: Short alarm sound when Arm the system. 9 10

Arm Delay Time Alarm Sound Time Armed Delay Time 30 Default: 30 seconds. Optional: 0~99 seconds. Alarm Sound Time 180 Default: 180 seconds. Arm Notify SMS Alarm Delay Time Armed Alert Tel 1 No Yes No: The 1st receiver will not get notify SMS when system Armed. Yes: The 1st receiver will get notify SMS when system Armed. Alarm Delay Time 20 Default: 20 seconds. Optional: 0~999 seconds. 11 12

Add Remote Control Edit Wired Zone 1 & 2 1.Basic Setting 2. Edit Zones 3. Advance Settings 1. Edit Remote 2. Edit Wired Zones 3. Edit RF Detector 1. Edit Remote 2. Edit Wired Zones 3. Edit RF Detector 1' SOS Button Type: 24Hr Silent Zone Name: SOS Help! 3' Wired Zone 1 Edit Remote Add Delete 1. Delete All 2. Used 3. Empty 2' Tamper Switch Type:24Hr Sound Zone Name: Tamper Switch Input: NO Type: Not Use Name: Wired Zone 1 Alarm 4' Wired Zone 2 Turn On Device Press a button on remote control Press OK Key Rec Code: 0B85BD Input: NO Type: Not Use Name: Wired Zone 2 Alarm. Wired Zone 1 NC NO st The 1 zone: the SOS button on the keypad. Press OK Key Rec Code: 0B85BD Press OK Key Operation OK Repeat do Press a button on remote control 1. Entrance Zone 2. Outer Zone 3. Inner Zone 4. Onsite Zone 5. 24Hr Sound Zone 6. 24Hr Silent Zone 7. Armed 8. Stay 9. Not Use 10. Door Bell nd The 2 zone: the tamper switch on back side. rd The 3 zone: the Wired Zone 1. th The 4 zone: the Wired Zone 2. NC: Normally Close NO: Normally Open If you setting the Wired Zone 1/2 as NC, then you have to connect NC sensor on the DIN1/DIN2 port, otherwise system will make alarm once switch ON. 1~10: Zone type see below explanation on page 16. 13 14

Add Wireless Sensors Zone Type Explanation Zone Type When sensor triggered, the alarm system will Used for Sensors 1. Edit Remote 2. Edit Wired Zones 3. Edit RF Detector 1. Delete All 2. Used 3. Empty 1. Entrance When you arm system: 30 seconds delay enter to arm mode, so you have time to leave home. When you back home: 20 seconds delay alarm, so you have time to disarm the system. Main gate or lobby Door sensors, PIR sensors Turn On Device Trigger the sensor Edit RF Detector Add Delete 2. Outer 3. Inner Stay Home Arm: Alarm Away Arm: Alarm. Stay Home Arm: No alarm. Away Arm: Alarm. Intrusion protection outside of the house Intrusion protection inside the house Door, PIR, Been, Vibration, Glass breakage sensors. CPIR, Door, PIR sensors Press OK Key Rec Code: 0B85BD Repeat do Trigger the sensor 4. Onsite 5. 24Hr Sound Stay Home Arm: alarm sound only Away Arm: alarm sound, alert SMS and dial Make alarm whenever Away, Stay Home or Disarm. System sends alert SMS, dial and audible alarm sound at same time. Windows or rear gate Smoke fire, Gas, Water, CO leakage detection Windows contact, Curtain PIR Smoke, Heat, Gas, Water, CO detectors 1. Entrance Zone 2. Outer Zone 3. Inner Zone Press OK Key Rec Code: 0B85BD Zone type refer to next page. 6. 24Hr Silent 7. Armed 8. Stay Make alarm whenever Away, Stay Home or Disarm. System sends alert SMS and dial only, no audible alarm sound. Shift to Away Arm mode. Shift to Stay Home Arm mode. Emergency help SOS alarm Press to Arm the system, no need remote control. Press to Stay Arm, no need remote control Fall detector, Panic buttons Wireless buttons Wireless buttons 1. Entrance Zone 2. Outer Zone Operation OK 9. Not Use 10. Door bell Disabled the sensor function. Make 6 door bell sounds. Disabled the zone Door bell Door bell buttons 15 16

Unique Monitoring Zone (the 5th zone) Bypass Zone Function The special zone type for take care of elderly, FIXED in the 5th zone only. System sends alert SMS to the 1st receiver if the sensor did not triggered during monitoring time period, this function works on Stay Home Arm mode only, if you changed the system to Away Arm or Disarm status, the monitoring function will be ignored automatically. The purpose of this Monitoring Zone: Take care of elder people s activities on daily life. For example, install one wireless door sensor at your Dad s bed room, setting the monitoring time period at 05:30~09:00, If he didn t get up (didn t open his door) during that time, The monitoring alarm send SMS only, no alarm call or audible alarm sound. Recommend sensors: Wireless door sensors, Curtain PIR motion sensors. Bypass definition: A bypassed zone will not set off the alarm no matter how often it is tripped. With this function, you can bypass an upstairs window so that you can leave it open during the day without having to worry about it setting off your alarm. For example, you want to be able to open and close a specific window during the night, while your system is armed; You want to bypass a certain motion sensor so that a person or pet can move through an area without creating an alarm event; While you are making repairs or renovations to your home, a sensor may be temporarily displaced - and you still want to use your system to protect the rest of the house. How to Bypass a specific zone? Step 1 Enter the two-digit number for the zone you want to bypass, single digit zones must be preceded by a zero, for example, "03", "06", or "09", etc. Step 2 Press the Disarm button, wait for the LCD display a " Zone xx Bypass" message, the zone bypassed confirmed. How to Cancel a Bypass zone? Press the Arm or Stay Home Arm button to arm your system as usual and enter the password, bypass zone function canceled. 17 18

Advance Settings Remote Access Control Interlock 1.Basic Setting 2. Edit Zones 3. Advance Settings AC Power Lost Alarm 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. AC Loss Alert 30 Default: 30 minutes. Optional: 0~99 minutes. 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. The system can open your electronic lock by pressing 01 and Key button, or interlock with your phone call in (your phone number must on the alert numbers list). 1. Interlock Armed by call: when you call in, system reject and recall back to confirm the arm success (you should reject the system s recall), and open your door at same time. This setting will help you to open the garage or main gate when leaving home by a single phone call. 2. Interlock Stay by call: you should call the system twice within 30 seconds, to change the system to Stay Home Arm mode, and open your door at same time. This setting will help you to open the garage or main gate when back home. Schedule Arm/Disarm 1. Interlock Armed by call 2. Interlock Stay by call 3. Not Interlock 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. 1. Arm Time: 22:58 2. Stay Time: 99:99 3. Disarm Time: 01:01 19 20

Contact ID Protocol over GPRS/3G Data Wireless Switch Code 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. Please Setup it by SMS command 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. 1. Coding 1 2. Coding 2 3. Coding 3 The alarm system supports CID protocol to CMS center over GPRS data communication, please setting it by SMS commands. 3 wireless code on the system, coding 1 is the default for wireless siren (*optional). Panel s SIM Card Number Modify Password 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. New Password: 9527 Password: 4 digits Default: 1234 1. AC Loss Alert 2. RF Opener Interlock 3. Timer 4. CID Protocol Over GPRS 5. Modify Password 6. Transmitter Coding 7. Panel s SIM Card No. Panel s SIM Card No. 00861351015 Enter the Alarm panel s SIM Card number for gain date & time from mobile network. Alarm system will get mobile operator's date & time according to the phone number, LCD will correct and display the real date & time after few minutes when setting done. If system can't get date & time automatically, please try to add or remove the country code, for example, 00861351015 instead of 1351015. 21 22

Alarm Event Logs 1. View 2. Setup 999 alarm event logs for review. 1. Alarm Record 2. Operation Record Setting & Operation by SMS commands The alarm system cab be easily setting by Smart phone APP or SMS commands with password protection remotely. * The SMS commands should with password, 1234 is the default password on below context, please change it to new password if you had changed already. * The command body AA, EE, etc. must be Caps Lock. * No space and ( or ) on the SMS commands, the space on command list just for reading purpose. Function SMS Commands Description & Example 3' 15-06-23 14:53:10 Entrance Alarm! Arm 1234AA Away Arm system without arm delay. Disarm 1234BB Disarm system. Operation Logs Alarm sound ON 1234CC Alarm sound OFF 1234DD Make audible alarm on Make audible alarm off 1. Alarm Record 2. Operation Record 1' 15-06-23 15:04:10 Disarmed by Keypad Inquiry status 1234EE K9 sends back the current status: AC/DC power status GSM Value: xx (01~31, less than 17 means mobile signal weak.) Arm/Disarm status IMEI code: xxx Modify password 1234 P new password 1234P6666 99 operation event logs for review. Add alert number (alarm receiver) 1234 position(1~9) A function code 1(1~3) #function code 2(1~3) # phone number# 12343A1#2#00861351015# Function code 1/2 refer to page 9. Inquiry alert number Delete alert number 1234A# 1234position(1~9) A # 12343A# 23 24

Setting & Operation by SMS commands Setting & Operation by SMS commands Wired zone 1 sensor type Wired zone 2 sensor type 123403 zone type (NC or NO)# 123404 zone type (NC or NO)# 123403NC# to set wired zone 1 sensor as NC connection. 123404NO# to set wired zone 1 sensor as NO connection. AC power lost alarm 1234 M time(00~99)# 1234M10# Default: 30 minutes, when AC/DC power lost more than 30 minutes, system sends SMS to the alarm receivers. Edit zone alert content 1234 B zone number# alert SMS content# 1234B05#Dad did not got up yet!# Alert SMS content: Max. 40 characters, can t be empty. Monitoring time 1234 Q start (hh:mm)# end(hh:mm)# 1234Q05:30#09:00# Monitoring time period from 05:30 am to 09:00 am, for the Zone number 5 only. Inquiry zone alert content Modify zone function 1234Bzone number# 1234D zone number (01~99)#function code(0~9)# 1234B06# 1234D06#1# th The 5 zone can t change zone function. One SMS setting more zones available, e.g.: 1234D06#1#07#2# Wireless Access Control time 1234 GT time (000~999) 1234GT030 Default: 1 second. To set the Wireless access control time, when press 01 and Key button, how long the wireless signal keep sending to the wireless switch to open the door(or other devices). Alarm sound time Alarm delay time Arm delay time 1234 E sound time (001~999)# 1234 F alarm delay time (000~999)# 1234 G arm delay time (00~99) 1234E120# Unit: second, Default is 180 seconds. 1234F030# Default: 20 seconds 1234G15# Default: 30 seconds Tips: When using remote control to Arm the system, press then Arm(A) button and then press the SOS(D) button immediately, K9 system will enter to Arm status without any delay. Alarm interlock relay working time Reboot remotely 1234 RT time (000~999) 1234RESTART 1234RT030 Default: 1 second. To set the alarm interlock relay closure time, how long the relay keep close after alarm occurrence. To reboot the alarm system by SMS. Arm notify SMS 1234 H# System sends Arm by xxx, Disarm by xxx to the 1st receiver when Armed/ Disarmed by SMS command. Arm notify SMS disable 1234 J# No SMS notification when system Armed/ Disarmed by SMS commands. Monitor on site voice 1234 K# System calls back for on site voice monitoring 25 26

GPRS Data Function (for engineer only) SMS Content list For engineer and remote server system only. Please ignore this part if the total quantity of the alarm system deployed less than 200pcs. Event SMS Content Remarks AC/DC power lost AC Power Goes off Default: AC Power Goes off 30minutes AC/DC power recovery AC Power Goes on Remote Control SOS Remote Key SOS Help! SOS button on remote control pressed. Data Function Setup 1234 APN apn name ; user name; password # 1234APNeverywhere; eesecure;secure# Zone #1 alarm Zone #2 alarm Zone #3 alarm SOS Help! Tamper Switch Alarm Wired Zone 3 Alarm! SOS button on panel pressed. Tamper switch on the back side triggered. Wired zone 1 sensor triggered. Contact ID server IP and Port 1234 IP IP address; port number# 1234IP175.164.49.20;4005# Zone #4 alarm Wireless zone #5 alarm Wired Zone 4 Alarm! Monitor Zone Alarm! Wired zone 2 sensor triggered. For monitoring zone only. Wireless zone #6 alarm Entrance Alarm! Wireless zone #7 alarm Zone 7 Alarm! Wireless zone #8 alarm Zone 8 Alarm! Wireless zone #9 alarm Zone 9 Alarm! Alarm Process Wireless zone #10 alarm Wireless zone #11 alarm Zone 10 Alarm! Zone 11 Spot Alarm! Alert SMS GPRS data to CID Server system Alarm dial out GPRS/UMTS data upload to server system depends on the alarm events(trigger) automatically, data connection off line when data send complete. The alarm system can't receive data from server. GPRS/UMTS data following the Contact ID (SIA DC-9) protocol. Wireless zone #12 alarm Wireless zone #13 alarm Wireless zone #14 alarm Wireless zone #15 alarm Wireless zone #16 alarm Wireless zone #16 alarm Wireless zone #17 alarm Wireless zone #99 alarm Smoke Detector Alarm! Water Leakage Alarm! Gas Leakage Alarm! Panic Help Alarm! For SM-100 or other smoke detector (*optional) For WL-100 (*optional) For GL-100/GL-100A (*optional) For EM-60/EM-100 (*optional) Emergency Silent Alarm! For EM-70/EM-90 (*optional) Zone 16 Alarm! Zone 17 Alarm! Zone 99 Alarm! Wireless sensor s battery low power alert Zone xx low voltage alert! Works for the sensors with low batter alarm functions only. 27 28

Connect with Wireless Switch Connect with Wireless Siren 1. Coding 1 2. Coding 2 3. Coding 3 1. Coding 1 2. Coding 2 3. Coding 3 Works with the wireless switch WS1 (optional), you can remote open your electronic lock or other devices by pressing or control by incoming phone call. Add wireless switch steps: 1. Connect WS1 relay output to the electronic lock as a switch. 2. Connect 12VDC from your lock to the WS1. 3. Press the learning button on WS1, LED flash quickly. 4. Press, WS1 LED off, connection created. 5. Press for test. How to open the door by phone call The alarm system inbuilt audible alarm function, in addition, you can also connect with the wireless siren (*optional) for the whole system. Just connect the power adapter of wireless siren is OK, then you can press for test if the siren is working or not. Please note that the wireless siren function works only on Coding 1" on Advanced Setting -- RF Interlock Switch. If you want to use the alarm system to operate other device but not the siren, you can select code 2 or code 3 and then programming the wireless switch as same as above mentioned on page 31. Specifications You can also call in to open your door or other devices by interlock settings(your phone number must on the alert numbers list, Caller-ID), setting method refer to page 20. 1. Interlock Armed by call: when you call in, system reject and recall back to confirm the arm success (you should reject the system s recall), and open your door at same time. This setting will help you to open the garage or main gate when leaving home by a single phone call. 2. Interlock Stay by call: you should call the system twice within 30 seconds to change the status to Stay Home Arm mode, and open your door at same time. This setting will help you to open the garage or main gate when back home. 3. Disabled the remote access control interlock function. GSM Frequency Radio Frequency Digital Output Rated Power Supply Power Consumption SIM Card Antenna Temperature Range Humidity Range Backup Battery Exterior Dimension Net Weight Quad-band 850/900/1800/1900 MHz 433.92MHz for sensors, 315MHz for wireless switch (*optional) 1 relay, NC/NO dry contacts,3a/240vac 9~24V DC/1A 12V input Max. 270mA, Standby 30mA Support 3V SIM Card 50 Ω SMA Antenna interface -20~+60 C Relative humidity 90% (condensing free) 3.7V/900mAH Li-ion rechargeable 18.8*13.1*2.8 cm (7.4*5.1*1.1 inch) 320 g (0.7 lb) 29 30

Specifications Trouble Shooting Safe Startup Do not use the alarm system when GSM/3G equipment is prohibited or might bring disturbance or danger. Interference All wireless equipment might interfere network signals of the alarm system and influence its performance. Avoid Use at Gas Station Do not use the alarm system at a gas station. Power off it when near fuels or chemicals. Power it off near Blasting Places Please follow relevant restrictive regulations. Avoid using the device in blasting places. Reasonable Use Please install the product at suitable places as described in the product documentation. Avoid signal shielded by covering the mainframe. Use Qualified Maintenance Service Maintenance can be carried out only by qualified person. No GSM signal 1) Backup battery low voltage. 2) GSM Module connection loose in transportation. 3) GSM Signal is too weak. Solution 1) Plug the AC/DC Power adapter. 2) Please take the panel to a mobile phone repair store, and then ask the engineer to check the GSM Module socket and the GSM Module connection. 3) Please change another location to install the alarm panel. Auto Restart Backup battery low voltage. Solution Plug the AC/DC Power adapter. False Alarm PIR Motion sensor installation incorrect. Solution-- Please install the PIR sensor according to the user manual carefully. No SMS/Call when alarm,no action when you send SMS command 1) GSM Operator communication protocol. 2) Didn t setup SMS Alert/Call receiver s phone umbers. 3) Caps Lock letters in the SMS. Solution 1) Change another GSM Operator SIM Card for test. 2) Setting SMS Alert/Call receiver s phone umbers correctly, e.g.: country code. 3) Check the commands with CAPS LOCK and correct format. Can not call in to the alarm panel 1) Country code incorrect. 2) GSM Signal too weak. Solutions 1)Check and ensure the country code format, e.g.: 0086 or +86. 2) Please put the alarm panel in strong signal coverage area. Big noise while two way talk 1) Near-Cross interference. 2) GSM Signal too weak. Solutions 1) Please make sure the other phone is far away from the panel. 2) Please put the panel in strong signal coverage area. 31 32