IMPROVEMENT OF JET ENERGY RESOLUTION FOR SEGMENTED HCAL USING LAYER WEIGHTING TECHNIQUE



Similar documents
ATLAS Test Beam Analysis in Stockholm: An Overview

Calorimetry in particle physics experiments

Jets energy calibration in ATLAS

Delphes, a framework for fast simulation of a general purpose LHC detector

Silicon Sensors for CMS Tracker at High-Luminosity Environment - Challenges in particle detection -

Calorimeter Upgrades for the High Luminosity LHC

Jet Reconstruction in CMS using Charged Tracks only

Information about the T9 beam line and experimental facilities

Which calorimeter for FCC detector

90 degrees Bremsstrahlung Source Term Produced in Thick Targets by 50 MeV to 10 GeV Electrons

A Guide to Detectors Particle Physics Masterclass. M. van Dijk

A.Besson, IPHC-Strasbourg

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

Proton tracking for medical imaging and dosimetry

Electron-Muon Ranger (EMR)

Atomic and Nuclear Physics Laboratory (Physics 4780)

JET ENERGY CALIBRATION IN ATLAS

Real Time Tracking with ATLAS Silicon Detectors and its Applications to Beauty Hadron Physics

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC

Precision Tracking Test Beams at the DESY-II Synchrotron. Simon Spannagel DPG 2014 T88.7 Mainz,

Detectors in Nuclear and Particle Physics

Testing thermo-acoustic sound generation in water with proton and laser beams

An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout

The TOTEM experiment at the LHC: results and perspective

Cross section, Flux, Luminosity, Scattering Rates

The accurate calibration of all detectors is crucial for the subsequent data

Recent SiD Tracking Studies at CU (and Ancient Outer Tracker Studies at SLAC)

variables to investigate Monte Carlo methods of t t production

The Compact Muon Solenoid Experiment. CMS Note. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. D. J. Mangeol, U.

Operation and Performance of the CMS Silicon Tracker

Simulation of Neutron Backgrounds from the ILC Extraction Line Beam Dump. Siva Darbha. Office of Science, SULI Program. University of Toronto

ENERGY LOSS OF ALPHA PARTICLES IN GASES

The OPERA Emulsions. Jan Lenkeit. Hamburg Student Seminar, 12 June Institut für Experimentalphysik Forschungsgruppe Neutrinophysik

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

Measurement of the Mass of the Top Quark in the l+ Jets Channel Using the Matrix Element Method

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Track Trigger and Modules For the HLT

Cosmic Ray Astrophysics with AMS-02 Daniel Haas - Université de Genève on behalf of the AMS collaboration

CMS Tracking Performance Results from early LHC Running

07 - Cherenkov and transition radiation detectors

Image Processing Techniques applied to Liquid Argon Time Projection Chamber(LArTPC) Data

Abderrahman El Kharrim

Geometrical importance sampling in Geant4: from design to verification

Characterisation of the Timepix Chip for the LHCb VELO Upgrade

Electron-Muon Ranger (EMR)

Tracking/Vertexing/BeamSpot/b-tag Results from First Collisions (TRK )

Solid State Detectors = Semi-Conductor based Detectors

A Process for ATLAS Software Development

Hadro-Production Experiments: Impact on T2K and LBNE

Event viewer for HRS-L

Introduction to Geiger Counters

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Performance of the CMS cathode strip chambers with cosmic rays

arxiv: v1 [physics.ins-det] 4 Feb 2014

Evaluation Tools for the Performance of a NESTOR Test Detector

1 Experiments (Brahms, PHENIX, and STAR)

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

arxiv:astro-ph/ v1 15 Sep 2005

Neutron Detection Setups proposed for

Gamma-rays from Dark Matter Mini-Spikes in Andromeda Galaxy M31. Mattia Fornasa Dipartimento di Fisica G. Galilei I.N.F.N. Padova

Radiation Detection and Measurement

AC coupled pitch adapters for silicon strip detectors

EUTelescope: tracking software

arxiv:nucl-ex/ v2 18 Jul 2005

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

Biasing. 7 th FLUKA Course NEA Paris, Sept.29-Oct.3, 2008

Monte Carlo Simulation for Solid Angle Calculations in Alpha Particle Spectrometry

Recent developments in Electromagnetic Hadron Form Factors

π 0 γγ calibration Savrina Daria, ITEP, Moscow SINP MSU, Moscow Victor Egorychev, ITEP, Moscow Ivan Belyaev

Single photon detection with H8500 MAPMTs for the CBM RICH detector*

HIGH-ENERGY COLLIDER PARAMETERS: e + e Colliders (I)

The Mainz LXe TPC MC simulations for a Compton scattering experiment

Delphes, a framework for fast simulation of a generic collider experiment

arxiv:hep-ph/ v1 1 Oct 2003

Energy Deposition in MICE Absorbers and Coils

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Study of the B D* ℓ ν with the Partial Reconstruction Technique

Theory versus Experiment. Prof. Jorgen D Hondt Vrije Universiteit Brussel jodhondt@vub.ac.be

SIZE OF A MOLECULE FROM A VISCOSITY MEASUREMENT

Performance of the BaF2-calorimeter TAPS 1

Transcription:

IMPROVEMEN OF JE ENERGY RESOLUION FOR SEGMENED HCAL USING LAYER WEIGHING ECHNIQUE V. Andreev 1, I. Golutvin 2, A. Nikitenko 3,V.Palichik 2 1 Lebedev Physical Institute, Moscow, Russia 2 Joint Institute for Nuclear Research, Dubna, Russia 3 Imperial College, London, UK / IEP, Moscow, Russia he future upgrade of CMS hadron calorimeter (HCAL) foresees increasing the number of longitudinal readout channels. It was shown that the longitudinal segmentation accompanied by the dedicated readout weighting method allows the essential improvement of the jet energy resolution. 1. INRODUCION In CMS jets are reconstructed with the three main methods, which differently combine individual contributions from sub-detectors to form the inputs to the jet clustering algorithm: calorimeter jets, Jet Plus rack (JP) jets and Particle Flow (PF) jets [1]. he future upgrade of CMS hadron calorimeter (HCAL) foresees the increasing longitudinal number of readout channels. Such new segmentation accompanied by the dedicated readout weighting method allows the essential improvement of the calorimeter jets energy resolution. In this paper H1-style software weighting method (π 0 -weighting) [2] is considered for the purpose of improvement the jet energy resolution. 2. READOU WEIGHING ECHNIQUES Energy resolution of non-compensated hadron calorimeters is affected by the different response of the calorimeters to the π 0 and non-π 0 components of the hadron shower. he electromagnetic (π 0 ) component of hadron showers is large 30 60%, it increases with energy and has a big and non-poissonian fluctuations (see, for example, Fig. 1 taken from [3]). Electromagnetic showers from π 0 component produce large and localized energy deposits in the calorimeters as illustrated in Fig. 2 ([3]). his feature (local deposition of high density energy) in segmented hadron calorimeter is used in the different readout weighting methods in order to reduce response of π 0 component and make it closer to the response of non-π 0 component. Such software methods can essentially improve both the energy resolution and linearity of the calorimeter [4].

Andreev V. et al. Improvement of Jet Energy Resolution 193 Fig. 1. Response of non-compensated calorimeter to hadronic ( h ) and electromagnetic ( e ) components of hadron showers and dependence of the average electromagnetic shower fraction on the energy of primary pions two top figures. Distribution of electromagnetic component of hadron shower bottom figure [3] In our investigation we used π 0 -weighting method which was developed in H1-collaboration [2] for fine segmented Pb Cu liquid argon calorimeter. CMS hadron calorimeter is a sampling calorimeter consisting of brass absorber layers (with different thickness for barrel and endcap parts) and 3.7-mm-thick scintillator layers. he additional 9-mm-thick scintillator layer (zero-layer) is located between ECAL and HCAL to sample hadronic showers developing in the dead material between these calorimeters. Using this structure of CMS calorimeter system and supposing that the readout from each individual layer of hadron calorimeter is available, the following expression is used for the primary pion and jet energy reconstruction: layers E rec = a E ECAL + H weighted i + c E zero, (1) i=1 where E ECAL is the deposited energy in electromagnetic calorimeter, E zero deposited energy in the zero layer and H weighted i is the weighted energy in each layer of hadron calorimeter. he weighted 7

194 CMS Detector at HL-LHC Fig. 2. Local energy deposits of high density for sampling calorimeter as consequence of π 0 production in different parts of non-compensated calorimeter [3] layer energy H weighted i is determined by the next formula (similar to H1-weighting method) with non-weighted layer energy H i in expression: H weighted i = b 1 H i + b 2 H i exp ( b 3 H i ). (2) he calibration constants a, b 1, b 2, b 3, c are determined for each energy of primary pion or jet by the minimizing of χ 2 from the following expression: χ 2 = (E rec E gen ) 2, (3) events where E gen is generated energy of pions or jets. And afterwards all these calibration constants are applied to determine the reconstructed energy of pions or jets. We will call this procedure π 0 -weighting reconstruction method. In what follows we will always compare the π 0 -weighting method with the standard ( E + bh ) reconstruction procedure, which is determined as E rec = E ECAL + b E HCAL, (4) where E ECAL and E HCAL are deposited energies in ECAL and HCAL active volumes respectively, E HCAL includes also energy in zero layer. A calibration coefficient b for HCAL is determined (and fixed afterwards) for pions with 50 GeV energy and the condition that the deposited energy in ECAL corresponds to MIP (minimum ionising particle).

Andreev V. et al. Improvement of Jet Energy Resolution 195 3. PERFORMANCE FOR SINGLE PIONS WIH SANDALONE GEOMERY Preliminary checking of this π 0 -weighting method was performed on the base of simple GEAN4 standalone simulation program which included description of CMS ECAL and HCAL calorimeters with some dead material between. he geometrical description reproduces in general the structure of the CMS calorimeters (Hadron Endcap calorimeter with 17 sensitive layers and zero layer between ECAL and HCAL). his standalone program is used for simulation in CMS Forward Calorimetry ask Force group [5]. Such kind of simplified simulation program can provide the first and quick estimation of the calorimeter response and the different reconstruction techniques. Figure 3 shows example of two different types of events simulated with this standalone program for incident pions with the primary interaction in ECAL or HCAL calorimeter volume. Dependence of the energy resolution ΔE/E (RMS of the distribution (E rec E gen )/E gen ) obtained with the π 0 -weighting method and comparison on the standard reconstruction procedure is presented Fig.3.Exampleoftwodifferenttypesofprimaryinteractionofpionssimulatedby standalone program: primary interactions in ECAL (top) and in HCAL (bottom) calorimeter 7*

196 CMS Detector at HL-LHC Fig. 4. Energy resolution as a function of incident pion energy for two different reconstruction procedures: open circles for the standard and closed circles for the π 0 -weighting technique in Fig. 4. he big improvement in the energy resolution is clearly observed for the π 0 -weighting reconstruction method in the full simulated pion energy range. 4. PERFORMANCE FOR SINGLE PIONS WIH CMSSW GEOMERY he Full Simulation Package CMSSW is used for checking the possibility to apply this π 0 -weighting reconstruction method for the real CMS calorimeter geometry. As the present CMSSW package doesn t simulate a separate readout for each layer of hadron calorimeter, the modification which can provide this information is introduced in CMSSW. he deposited energies in active volume of ECAL and in scintillator of HCAL layers provided by GEAN4 are considered as the response of calorimeters. he deposited energy in ECAL and HCAL calorimeters inside cone with R = 0.7 (R = (Δη 2 +Δϕ 2 ) ) around direction of incident pions are collected for reconstruction procedures. he value of pseudorapidity η = 0.65 and ϕ-angle range π ϕ π for direction of the primary pions are chosen in this simulation. Figure 5 shows the distribution of reconstructed energy for 10 GeV pions obtained with the two different reconstruction procedures ( standard and π 0 -weighting). he π 0 -weighting method demonstrates essential improvement of both the quality (shape is close to Gaussian distribution) and quantity (decreasing RMS of distribution) of reconstructed pion energy. he energy resolution obtained with π 0 -weighting reconstruction method is summarized in able 1 and presented in Fig. 6 as a function of primary pion energy. he same results for the standard reconstruction procedure are added for comparison. As for the standalone simulation

Andreev V. et al. Improvement of Jet Energy Resolution 197 Fig. 5. Distribution of reconstructed energy for 10 GeV pions simulated with CMSSW program and reconstructed by two different reconstruction procedures: standard and π 0 -weighting methods able 1. Energy resolution ΔE/E (%) as a function of incident pion energy for two different reconstruction procedures ( E + bh andπ 0 -weighting) determined from CMSSW simulation E gen 5GeV 10 GeV 20 GeV 30 GeV 50 GeV 75 GeV 100 GeV E + b H 36.68 28.81 21.71 18.41 16.27 15.04 13.67 π 0 -weighting 23.25 18.58 15.17 12.97 11.03 10.33 9.54 Fig. 6. Energy resolution as a function of incident pion energy for two different reconstruction procedures ( standard and π 0 -weighting) with CMSSW full simulation case, an essential improvement of the energy resolution is also observed for the CMSSW simulation.

198 CMS Detector at HL-LHC 5. PERFORMANCE FOR JES WIH CMSSW GEOMERY One of the most important characteristics of different jet reconstruction algorithms is the jet energy resolution. So, the advantage of the π 0 -weighting reconstruction technique should be firstly demonstrated on jet energy resolution. Using the modified CMSSW with separate readout from each hadron calorimeter layer gluon-jets are generated and simulated. he primary jets were generated with the pseudorapidity η = 0.65 and inside ϕ-range π ϕ π. he deposited energies in ECAL and HCAL calorimeters inside a cone with R = 0.7 around primary jet-direction are collected for jet energy reconstruction. he calibration coefficients a, b 1, b 2, b 3, c for jet energy reconstruction with π 0 -weighting method are determined separately for each jet p with the same procedure given by expressions (1) (3). For the standard ( E + bh ) jet energy reconstruction the same calibration coefficient b obtained for 50 GeV pions is used. Figure 7 shows the jet p resolution Δp /p (sigma of the distribution (p reco p gen )/pgen ) for two different reconstruction procedures: standard and π 0 -weighting methods (jet energy correction factor is applied for standard reconstruction). he clear improvement in jet p reconstruction is observed both for RMS of distribution and for the sigma from Gaussian fit. Fig. 7. p resolution distribution for jets with p gen = 50 GeV for two different reconstruction procedures: standard (left) and π 0 -weighting (right) methods able 2. p resolution of jets Δp /p (%) as a function of generated jet p gen the standard and π 0 -weighting reconstruction procedures jet p gen 10 GeV 20 GeV 30 GeV 50 GeV 75 GeV 100 GeV E + b H 29.37 19.97 15.81 12.41 10.27 9.06 π 0 -weighting 25.86 16.36 12.84 9.82 8.12 7.06 for

Andreev V. et al. Improvement of Jet Energy Resolution 199 Fig. 8. Jet p resolution as a function of generated jet p gen for two different reconstruction procedures: standard and π 0 -weighting methods he results of jet p resolution for the different p gen of generated jets aresummarizedinable2andshowninfig.8.hesigmaofdistributions is used for determination of jet p resolution. As was observed for single pion simulation, the π 0 -weighting technique of jet p reconstruction demonstrates essential improvement of p resolution 25 30% in the broad 10 100 GeV p range. 6. SUMMARY he π 0 -weighting reconstruction technique used for segmented HCAL improves jet energy resolution by 25 30% for jets in the range 10 100 GeV. his improvement still has to be verified with the realistic simulation of readout electronics, thresholds and with pileup simulation, taking into account radiation damage for High Lumi-LHC. REFERENCES 1. CMS Collaboration, Jet Plus racks Algorithm for Calorimeter Jet Energy Corrections in CMS, CMS PAS JME-09-002 (2009); CMS Collaboration, Particle-Flow Event Reconstruction in CMS and Performance for jets, aus, and E, CMS PAS PF-09-001 (2009). 2. H1 Calorimeter Group, Results from a test of a Pb-Cu liquid argon calorimeter, NIM A265 (1988) 419 434; H1 Calorimeter Group, Performance of a Pb-Cu liquid argon calorimeter with an iron streamer tube tail catcher, NIM A275 (1989) 246 257; V. Shekelyan, Simulation and reconstruction in H1 liquid argon calorimetry, H1 note, H1-04/93-288; H. P. Wellisch, J. P. Kubenka, H. Oberlack, P. Schacht, Hadronic Calibration of the H1 LAr Calorimeter using Software Weighting echniques, MPI- PhE/94-03, January 1994 (H1-02/94-346).

200 CMS Detector at HL-LHC 3. R. Wigmans, Effect of calorimeter peculiarities on the jet scale, Pisa Workshop on Jet Reconstruction and Spectroscopy at Hadron Colliders, April 18, 2011, J. Phys.: Conference Ser. 323(2011)012001; D. Acosta et al., Lateral shower profiles in a lead/scintillating fiber calorimeter, NIM A316 (1992) 184 201; N. Akchurin et al., Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection, NIM A399 (1997) 202 226. 4. J. P. Dishaw, he production of neutrinos and neutrino-like particles in proton-nucleus interactions, hesis, SLAC-216, 1979; H. Abramowicz et al., he response and resolution of an iron-scintillator calorimeter for hadronic and electromagnetic showers between 10 GeV and 140 GeV, CERN-EP/80-188, October 14, 1980; Halil Saka, Chris G. ully, CMS Barrel Hadron Calorimeter est Beam 2009 Analysis with Layer Weighting echnique, CMS IN -2010/016, 20 May 2010 (V. 2, 08 June 2010); M. Stein et al., Studies with an Energy Weighting Method for the Upgrade of the Hadronic Barrel Calorimeter of CMS, CMS CR-2010/028, 29 January 2010. 5. https://twiki.cern.ch/twiki/bin/view/cms/fcalsimslhc.