GE Energy Wind Technology and Windfarm Overview



Similar documents
GE Power & Water Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY.

Onshore Wind Services

GE Energy 1.5MW. Wind Turbine

V MW. Your best option for low cost energy production at low and medium wind sites. Federico Gonzalez Vives. Director Technology.

V kw The turbine that goes anywhere

Nordex SE. Capital Markets Day Products & Sales - Lars Bondo Krogsgaard

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

PMDD WIND TURBINE 1.5MW

Siemens Wind Turbine SWT The new productivity benchmark.

NORDEX USA, INC. GREAT LAKES SYMPOSIUM

GE Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY.

V MW Making wind even more profitable

GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT.

QUALITY OF WIND POWER. How does quality affect the cost of electricity generation from wind power?

GE Energy. Solutions

Monitoring the Operation of Wind Turbines Alex Robertson, Vestas Northern Europe

Passion for Offshore. Wind Power & Renewables Division Market Unit Offshore

2.1MW PLATFORM Generations ahead

OPERATION AND MAINTENANCE. Levent İshak Service Manager, Vestas Turkey

MAXIMISING YOUR. Offshore wind assets ASSET OPERATION & MAINTENANCE SERVICES

Case Study 5 Use of Wind Turbine Technology

Nordex SE. Nordex goes Offshore

Siemens D7 platform 6.0-MW and 7.0-MW direct drive wind turbines. The new standard for offshore. siemens.com/wind

ALSTOM IN THE WIND. Industry Trends. CIII class wind turbines will represent over half of total installs in 2016

EXPERT REMANUFACTURED WIND TURBINE

Outline. Introduction to Wind Energy. US Wind Energy Installations. ME 483 Alternative Energy Engineering II 1

Wind turbine database: Modelling and analysis with focus on upscaling. Master s thesis in the Master programme Applied Mechanics

The Reliance on Wind Energy Depends on Advancements in Blade Pitch Control

POWER CURVE MEASUREMENT EXPERIENCES, AND NEW APPROACHES

Power Performance Testing: Truly Useful of Just Box Ticking. Mark Young 2 July 2012

GE Wind Turbine Climbing Rules and Rescue from Height

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

V MW & V MW (OFFSHORE)

Title: IEC WT 01 vs. IEC Development of a new standard and innovations in certification of Wind Turbines. mike.woebbeking@gl-group.

EFFECTS OF COMPLEX WIND REGIMES ON TURBINE PERFORMANCE

ENERCON WIND TURBINES

Sound Power measurements according to IEC

Document number #12 DNS Authors #20 Telephone: Date #40 AUGUST 2013

Simplified Design as Secret to higher Performance: Siemens Direct Drive Technology

Press Presse Press Presse

Operational analysis & Optimisation

THE NEW GUIDELINE FOR THE CERTIFICATION OF WIND TURBINES, EDITION 2010

Haliade 150-6MW Experiencia funcional con la nueva generación offshore

Wind Turbine Power Calculations

Session: Turbine Manufacturers and New Technologies. Istanbul November 2014 A.Beyer

Development of 5-MW Offshore Wind Turbine and 2-MW Floating Offshore Wind Turbine Technology

V kw. Pitch regulated wind turbine with OptiTip and OptiSlip

Libellula 50/55 kw WIND TURBINE TECHNICAL DESCRIPTION

Ensuring Vestas current and future competitiveness

SMART ASSET MANAGEMENT MAXIMISE VALUE AND RELIABILITY

Enhancing Business Performance using Integrated Visibility and Big Data

INFLUENCES OF VERTICAL WIND PROFILES ON POWER PERFORMANCE MEASUREMENTS

Managing Wind Farms in the San Gorgonio Pass

Assessment of the Economic Benefits of Offshore Wind in the Mid-Atlantic

Critical Limitations of Wind Turbine Power Curve Warranties

N60/1300 KW. Nordex N60 Long-term experience all over the world.

Lecture 4 Energy Conversion in Wind Turbine

Wind Energy Development in Jamaica

Dansk Offshore Netværk, Lindø Industripark, 21. April 2015 The Road to Below 10 ct /kwh

Uptime for Wind Turbines. Dedicated Remote Condition Monitoring System for the Wind Power Industry

Innovative Medium-Speed Drivetrain Design Program and Dynamometer Testing

ENERGY YIELD ASSESSMENT

Óbuda University Power System Department. The wind. Dr. Péter Kádár Óbuda University, Power System Department, Hungary

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

SCADA 2014 systems for wind

Wind resources and wind turbine wakes in large wind farms. Professor R.J. Barthelmie Atmospheric Science and Sustainability

Wind Turbine Technology Overview

PMG vs. DFIG the big generator technology debate

Forces on Large Steam Turbine Blades

Industrial Metrology and Engineering Applications in the Wind Turbine Industry

Wind Turbine Design Cost and Scaling Model

The DTU 10-MW Reference Wind Turbine

Brochure. Electric generators to power the world

Transformer Fleet Management with e-terraassetcare

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

OFFSHORE WIND TOWARD 2020 ON THE PATHWAY TO COST COMPETITIVENESS

Deutsche WindGuard. WindGuard North America Varel / Berlin /Bremerhaven, Germany Goderich, Canada. info@windguard.de

Nordex SE. Capital Markets Day Introduction - Thomas Richterich

Brochure. Generators for wind power Proven generators reliable power

Wind Service Offshore. We can t conquer the elements But we can outthink them

in-service inspections

Advanced nacelle anemometry and SCADA-data, analysis techniques and limitations. Frank Ormel Chief Specialist in Product Integration Vestas

BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20 (Phase A)

The Promise of Industrial Big Data

McKinsey on Electric Power and Natural Gas

Wind Resource Assessment for BETHEL, ALASKA Date last modified: 2/21/2006 Compiled by: Mia Devine

Some scientific challenges in aerodynamics for wind turbines

Christopher Monk Engineering Manager STRUCTeam Ltd

Improved Bankability. The Ecofys position on LiDAR use. Summary

GRAVITY BASE FOUNDATIONS

Wind Power Overview - with offshore focus. Jörgen Svensson Industrial Electrical Engineering and Automation

E.ON Wind Turbine Technology and Operations Factbook

Comparison of Resource and Energy Yield Assessment Procedures

Newsletter September 2013

Transcription:

GE Energy Wind Technology and Windfarm Overview Forum on Renewable Energy Development in Myanmar November 1, 2012 saumil.shah@ge.com

Topics for discussion Introduction to Wind Power technology Windfarm design Windfarm construction Windfarm operation

GE Renewables wind business World s most efficient & reliable wind turbine fleet 28GW+ installed ~18+k WTGs in 22 countries 98+% availability 15% Energy capture 52% GE Onshore Product strategy Portfolio flexibility value where you need it Evolutionary development strategy world s best running fleet Continual investment focused on increasing customer value Invested $2B in technology GE is changing the game

GE s Installed Wind Fleet USA (12,617 units/19,202 MW) Europe +Turkey 16 Countries China (792 units/1,188 MW) (3,533 units/5,900 MW) Canada (1,070 units/1,619 MW) Brazil (59 units/94 MW) Japan (290 units/478 MW) Over 18,000+ WTGs, 28GW+ installed 22 countries 4 As of 2Q 2012

Wind technology overview

Wind Turbines... a highly engineered product 103 meter blade diameter is larger than a Boeing 747 wing span Swept Area = 8332 sq m = 2.05 acres Tip speed of GE wind turbine is 322 km/h F-18 Hornet at take off is 225 Thrust load is greater than 2 X F-18 in max after burn Power Electronics 18,000 switching events per second GE converter fleet = 200M switches/sec Input torque is >2,000 knm, (~1.5M ft-lbs) ~2,400 times torque from an Indy car engine Pitch bearing supports >6,000 knm 7 ton Mack dump truck at a lever arm more than a football field 6 2012, General Electric Company

Modern Wind Turbines Onshore & Offshore 80 110+ meter hub height onshore Rotor diameter 50 120m Output 0.75 5MW Operates between wind speed of typically 6 25m/s Tubular steel towers Remote operation through web based instrument control Note: 1MW equivalent to energy for approximately 1,300 homes in Thailand

Components of a Wind Turbine (Model shown is Vestas V80 - onshore wind turbine) Nacelle Oil cooler Ultrasonic sensors High voltage transformer Electrical generator Rotor blades Hub controller Main shaft Gearbox Yaw gears Tower Hydraulic system

1.6-100, 96m HH, 4-Section Tower Improvements Comparison with 100mHH Tower 24.05m Same robust top flange design 24.05m Longer Individual Sections 100m Natural Frequency Optimized 96m Buckling and Frequency Optimized 24.05m 96m Tower approx. 20% lighter, 68 MTs 21.2m Reduced frequency vibrations, large tower & fast spending rotor, not tower buckling such as crushing a can

GE Component Test Lab Greenville, SC Main Bearing Pitch Bearing Bedplate Gearbox Setting the standard on reliability

Quality and performance critical the downside of getting it wrong Cross-section of wind blades Bond joint critical to blade life Blade life? 20yr+ life Chinese OEM blade GE designed blade Poor quality can reduce wind farm value by 80%+ Long term asset customers buy quality 11 Source: Karen Newby, Journal Star; GE Marketing

Evolution of GE wind products Units >> 1,000 th 5,000 th 10,000 th 18,000 th 2.5-120 2.5s (88m) 2.5xl (100m) 2.75-100 2.75-103 2.85-103 Model introduction 1.85-82.5 1.5i (65m) 1.5s (70.5m) 1.5sle (77m) 1.5xle (82.5m) 1.6-82.5 1.6-100 1.7-100 96 02 03 04 05 06 07 08 09 10 11 12 13 GE enters wind industry GE 37c blade GE 40m blade Mark VIe controller GE 48.7m blade Next Gen Grid LVRT introduced GE Pitch HALT Introduced WindBOOST Enhanced controls GE Wind Products 02 12 AEP (GWh/yr)* 6.0 12.6 Capacity Factor (%)** 45 60 Availability (%) 85 98 *2.5-120@8.5m/s, **1.6-100@8.5m/s, EOY 12 +110% +33% +15% GE wind products proven performance and reliability 12

GE 4.1-113 World s highest output shallow water (offshore) turbine Solid electrical system design... Enhanced reliability... modular generator & converter design High efficiency... PM Generator Direct-drive Simple mechanical design... Protected from offshore environment... sealed nacelle containing all components Robust & reliable... up-scaled components from proven 1 3 MW models Designed with service in mind... Serviceability... In place tower exchange for converter and generator parts Spacious nacelle with internal hub access Proven direct drive technology over 5 years operating experience

Large machines

Bigger is not always better 60% 2.X-8.5 m/s 1.6-82.5 1.6-100 55% 2.X-7.5 m/s 1.X-8.5 m/s 1.6-82.5 1.5.77 1.6-87 Capacity Factor 50% 1.X-7.5 m/s 1.5-77 1.6-100 45% 2.5-100 1.6-87 2.75-103 ~100 MW Wind Farm 1.6-82.5 WTG # WTGs MW Total 1.5-77 66 99.0 1.5-77 2.75-103 1.6-82.5 62 99.2 40% 2.5-100 1.6-100 62 99.2 2.5-100 40 100.0 2.75-103 36 99.0 35% 325 350 375 400 425 450 475 500 525 550 AEP, GWHrs 100 MW wind farm production

Windfarm design

Wind Project Technical Challenges Energy yield assessment Data acquisition Wind modeling Layout design Uncertainty analysis WTG technology selection and specification Electrical system design Foundation and road design Environmental assessment Maximising operating performance

Site data requirements 12 months site data for seasonal balance Mast set up to IEC or equivalent standard Location representative of whole site As close to hub-height as possible least ¾ advisable) (at Free from sheltering Instruments calibrated and correctly configured Wind speed Collected from several heights to assess shear wind 10 minute averages from high frequency samples Standard deviation (to calculate turbulence) Max 3 second gust Wind direction 10 minute averages from high frequency samples Standard deviation

Wind Resource Assessment Inputs Flow angle Annual mean wind speed @98m - Vavg Extreme wind Vref Flow angle 3º Shear measured (40-60m) Characteristic Turbulence Intensity 6.7 7.0 m/s 33 m/s 0.25 13% Air density 1.210 kg/m 3 Shear β All parameters below IEC IIIb Wind speed

Optimum Product Mix Several factors impact turbine suitability Comparing avg. wind speed (site vs. wind class) not sufficient Any parameter below IEC standard creates design margins Mech. Load % design Design limit Excess margin IEC 61400 Design Envelopes (TC) Ia Ib IIa IIb IIIa IIIb V ave [m/s] 10 10 8.5 8.5 7.5 7.5 V ref [m/s] 50 50 42.5 42.5 37.5 37.5 V e50 [m/s] 70 70 59.5 59.5 52.5 52.5 TI 15 [%] 18 16 18 16 18 16 Air density [kg/m³] 1.225 1.225 1.225 1.225 1.225 1.225 Vertical wind shear exponent [-] 0.2/ 0.11 0.2/ 0.11 0.2/ 0.11 0.2/ 0.11 0.2/ 0.11 Flow inclination [ ] 8 8 8 8 8 8 0.2/ 0.11 Portfolio flexibility value where you need it Blades Hub Main Shaft Gearbox Bedplate GE wind turbine models offering flexible configuration for site specific optimization Tower 1.6MW, 2.5MW, 2.75MW 82,5m, 100m, 103m, 120m (3.xMW 2015) (120+ 2015) 75m,80m, 85m, 96m, 98,3m, 123.5TT Optimze your WF with GE s product portfolio based on one core design architecture and an +15year evolutionary design strategy Turbine selection complexity increasing, GE can help

Site wind conditions IEC TC IIIb Site Impact on loads LAYOUT -- 31 -- WRA: -- GE -- Vavg [m/s] 7.5 7.3-9.3 Weibull shape factor (k) 2 2.2-2.5 CTI @ 15m/s [%] 16 8.7-11.6 Vertical Shear exponent [-] 0.20 0.07-0.22 Flow inclination angle [º] 8 0.6 6.3 Air density [kg/m 3 ] [StW/CWE] 50-yr 10min gust [m/s] [StW/CWE] 1.225 / 1.269 / 1.452 1.038 40.0 / 37.5 34.1 46.5 All site conditions rarely align across all modeled parameters Site specific loads analysis performed always to confirm suitability

Mechanical Loads Analysis GE s rigorous Mechanical Loads Analysis model uses V avg, V ref, CTI, air density, shear, flow inclination angle, wake effects, and wind speed distribution to ensure site loads are within the design loads envelope of the wind turbine. Selecting the correct WTG can increase AEP by as much as 1GW/yr = $1MMNPV* *$50/MWHr PPA GE 1.6-100 Tehachapi, CA

Mechanical Loads Analysis, MLA, inputs Wind rose Wind speed distribution, V avg Turbine spacing wake effect Vw Extreme wind conditions, V 50 Characteristic turbulence Intensity Air Density Flow inclination angle Wind shear

Wind farm layout Pole or land constrained Phase 2 Phase 1 of the project is limited to XX fixed turbine positions Phase 2 open in terms of number and size of turbines to reach a total project capacity of 300MW Phase 1 Phase 2: optimized for different product scenarios Number of turbines based on the Rated Power -> 200MW Different HH and RD possible + Wind Reserve Option 2000m

Calculating gross yield The wind flow model is used to calculate the gross energy yield of the wind farm, using: Wind turbine measured power curve Adjusted for site air density Warranted by manufacturer Wind turbine thrust curve (for calculating wake effects) Methodology Wind speed distributions for each direction sector, at each turbine location and are extracted from wind flow model and integrated across power curve. Wake losses are calculated using specialist software models

Calculating net energy yield Net yield is reduced from gross yield to account for efficiency factors, availability, planning constraints (e.g. shadow flicker / noise) or manufacturer imposed curtailments Typical Losses and adjustments to gross yield: Loss Factor Turbine availability 0.960 Blade degradation 0.985 Blade icing 0.990 Wind hysterisis 0.990 Electrical efficiency 0.970 Substation availability Adjustment 0.997 Grid availability 0.997 TOTAL adjustment 0.894

Windfarm construction

Windfarm elements Turbine foundations Site roads Approach roads Inter-turbine electrical network Substation Grid interconnection

2.x Truck Examples

Turbine Erection

Windfarm operation

Windfarm Operation Key driver of windfarm performance is turbine availability Turbine supplier should guarantee 95-98% availability for warranty period Long-term 98% levels are achieved by some onshore portfolios internationally Typically operated without staff on site remote operation and technical support Cost savings for portfolio operators Need for owners to build a degree of in-house O&M capacity Requires careful negotiation with turbine suppliers on operator training and turbine performance data access, in advance of placing new orders Less of a critical issue if third-party O&M providers present

1.5/1.6MW availability trends 07 08 09 10 11 2Q 12 2007-2012 1.X platform Model Year Trends 2007 95.6% 97.1% 97.6% 96.9% 97.6% 98.3% 2008 97.0% 98.1% 98.0% 98.4% 98.6% 2009 97.0% 98.1% 98.1% 98.0% 2010 97.9% 98.2% 98.3% 2011 98.2% 98.6% 1.5-82.5 98.5% 98.2% 98.5% 98.8% 1.6-82.5 98.5% 98.6% Improved design Year over year 2Q 2012 Improved service, resolved top issues Model year: The year in which a turbine is commissioned First 12 weeks of operation excluded World s best running fleet defined 35

Remote Monitoring & Diagnostics maximized availability 24X7 customer support including strong collaboration with field engineers Centers - Salzbergen, Germany & Schenectady, NY Hot Swap Capability 50+ customer service specialists 7,000+ turbines controlled remotely 98%+ availability Fleet analysis operating rhythm with engineering-based fault resolution, continuously evolved 12,700+ turbines w/ data connections * As of EOY 2011 36

GE Energy Learning Center (ELC) State-of-the-Art Training Technical Training 2000 engineers 1200 technicians High-Risk EHS Training 1526 classroom 1074 WEBEX Leadership Programs World-Class EHS Training Digital Program Development Simulated Demonstrations Blended Training Solutions Guided Self-Assessments Interactive Animations Video Analysis Offline Learning Solutions World-wide Productivity 1 million online completions 181 online EHS courses 20 different languages Tiered Structure Flexibility Global Country Business Site

O&M Contracts from Turbine Suppliers Typically fixed price for a specified period with the option to renew 2 or 5 years are typical terms Guarantee for availability with damages based on lost revenue for non-performance Availability needs to be carefully defined Third party operators in the future? Historically lower-cost and can be higher performing (supply constraints, warranty incentives for supplier to fix worst performing, rather than optimise) Will likely take time to build up a third-party capability

GE multi-level support packages Maintenance and Remote Operations Extended Parts and Services Full Service Agreement Remote Monitoring & Troubleshooting On-Site Support Unplanned Maintenance Routine Services Preventative Maintenance Providing defined scope of planned maintenance. Parts Package Availability Guarantee Ensuring highest standards of operation. Condition Monitoring Turbine Performance & Life Extension Worry-free operation & maintenance. Flexible options crucial to meeting unique customer needs

GE wind services experience GE wind fleet Mining the installed base Cumulative units 2,000 5,500 13,500 21,000 + Technical fleet data and insight 18,000+ units operating globally 1,000+ technicians, 350 reliability engineers Differentiated rigor and speed 80% of issues resolved within 10 mins Smart early warning algorithms Upgrading fleet performance Driving new tech into fleet '03 '06 '09 '12F World s best running fleet 98%+ availability 40

GE s wind services locations Service Ctr. Parts Distribution Ctr. Parts Distribution Ctr. Europe HQ Parts Operation Ctr. Service Ctr. Central Warehouse 2 Service Centers Parts Operation Ctr. Service Ctr. Parts Distribution Ctr. Energy Learning Ctr. Renewable Energy HQ Remote Operations Ctr. Services Offices Services Ctr. Energy Services HQ Customer Support Ctr. Parts Distribution Ctr. Parts Distribution Centers Services Office Global resources, local support

Thank You