Doc. no.lec-om05101. PRODUCT NAME Controller setting kit install manual (bundled with CD-ROM) MODEL/ Series LEC-W2



Similar documents
Installation Manual LATC-W1

Installing PowerLink on Windows 7 64-bit

Select Correct USB Driver

Guide to Installing BBL Crystal MIND on Windows 7

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS. For. Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS

USB Driver Installation for Windows XP

Installing the Gerber P2C Plotter USB Driver

Windows XP.. ELITE Firmware Update procedures.. v1.41

ScanWin Installation and Windows 7-64 bit operating system

Connecting your Omega/BetaPAT PLUS to a PC via a USB

Safety Precautions WARNINGS

Printer Sharing of the Brother QL-Series in a Windows Environment

SAPIP GUI INSTALLATION. Table of Contents

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

USB DRIVER INSTALLATION GUIDE

Colorfly Tablet Upgrade Guide

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

ISK 200 Driver Installation

Virtual COM Port Driver Installation Manual

Virtual COM Port Driver Installation Manual

HUMAC2009 Software Installation Instructions for Windows XP and Vista

USB 3.0 to Gigabit Ethernet Adapter

Iridium Extreme TM Satellite Phone. Data Services Manual

KI6501 Data Manager. Software User Manual

Install Device Drivers and Toolkit for Windows 7

Installing Global Logger USB Drivers

PP8X Printer Driver Installation Instruction

Please read and understand this instruction manual thoroughly before using this product.

1. TIB388 about the Windows compatibility of all Mutoh devices subdivided in

How to install USB driver (MICRO/I)

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

3. USB DRIVER Installation of USB driver Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual

SOFTWARE INSTALLATION INSTRUCTIONS

Windows 7 Printer Driver Installation procedure

SoundLAB Software Download Software from the Bogen website:

Screen Capture. User s Guide. For ClassPad Series

Installation of USB Virtual COM. Version 1.02

Chapter 1 Downloading Images to Your Computer (Windows)

Data Management Software. CL-S10w. Installation Guide

MonitorKey USB Driver Installation Instructions

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

Installing the IF-NMEASC & SC30 Windows XP Drivers & Software

Title: ZOLL USB Direct Connect Cable Installation Instructions

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

USB/RS485 Communication Cable Installation

Centurion PLUS CPC4 Download Guide

USB DRIVER INSTALLATION GUIDE

CANON FAX L360 SOFTWARE MANUAL

Printer Sharing of the PT-9500pc in a Windows Environment

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

CODESOFT Installation Scenarios

AUDITVIEW USER INSTRUCTIONS

Printer Support Guide. FedEx Ship Manager Software

CMP-102U. Quick Installation Guide

PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)

IVS-Basic 4.4 IVS-Professional 4.4 IVS-PowerPoint 1.1

AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE

Blastmate III and Minimate Plus USB to PC Cable (Part No. 716A3401)

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

Installation Instructions

AUDITVIEW USER INSTRUCTIONS

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

IrDA-USB IrDA USB Adapter

USB 2.0 TO IDE/SATA ADAPTER CABLE

MF Driver Installation Guide

Clavia USB Driver v2.06. Manual driver installation, Windows XP. Clavia USB Driver v2.06

BMV-602 Data Link Manual

Lab: Data Backup and Recovery in Windows XP

Caplio Utility for Windows

DIAL-UP DATA. User s Guide

PL2303HXA/XA Windows 8 Update Driver Installation. How to Update Driver to Support PL2303HXA/XA in Windows 8 Operating Systems

Metasys System Direct Connection and Dial-Up Connection Application Note

User Manual. 2 Bay Docking Station

Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software

Installing a printer in Windows 95.

USB TO SERIAL CONVERTER

Print Server Application Guide. This guide applies to the following models.

Installing the USB driver for Firmware 7 or later For use with E-blocks programmer boards and PICmicro Development boards.

USB Driver Installation Manual [Windows Vista/Windows 7]

Mini Amazing Box Update for Windows XP with Microsoft Service Pack 2

Windows XP Home Edition / Windows XP Professional

WindO/I-NV2 Utility Pass-Through Tool

DIGITAL FULL COLOR MULTIFUNCTIONAL SYSTEM. Software Setup Guide

Downloading Images and Movies from a Digital Camera to OLYMPUS Master 2

MF Driver Installation Guide

Guide for Remote Control PDA

The FlexiSchools Online Order Management System Installation Guide

USB Driver. Installation Manual

Running the R4 Software on a USB Port

Configuring Windows 7 64 bit for AutoVISION

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

Verbatim Secure Data USB Drive. User Guide. User Guide Version 2.0 All rights reserved

ENPS-MF1. 1 USB Port. Multifunctional Print Server. Quick Installation Guide V1.0

Software Repair Assistant Manual for DuraXV

Communication with BushingGard using computer USB port

EDMS Operation Manual. 1. Install the USB Driver. 1.3 Click next

English version. Introduction. Hardware. Installation under Windows 98SE. PU006 Sweex 2 Port Serial PCI Card

Driver Installation for Windows XP Home Edition and Windows XP Professional

Transcription:

Doc. no.lec-om05101 PRODUCT NAME Controller setting kit install manual (bundled with CD-ROM) MODEL/ Series LEC-W2

LEC-W2 procedure for installing driver and software 0. Preparation Prepare the following before using the ACT Controller software. 0.1 Personal computer This software can be used on a PC operated with Microsoft Windows XP 32bit and Windows 7 32bit or 64bit. 0.2 USB cable Please prepare the communication unit, the communications cable, and the USB cable (A-mini B type) 1. Installation 1.1 Installation of communication unit s driver When the communication unit is connected to the USB port of the PC. <Windows XP> The following screens are displayed. <Windows 7> Open the Control Panel Hardware and Sound. Push the Device Manager button in the screen. Right-click on SMC Serial Converter displayed in Other devices and select the [Update Driver Software...].. (1) Please insert CD-ROM (2) <Windows XP> Select [Install from a list or specific location (Advanced)] and push the [Next >] button. <Windows 7> Push the [Browse my computer for driver software] button. Windows XP Windows 7 (3) The following screen will be displayed. <Windows XP> Click [Include this location in the search]. <Windows 7> Click [Include subfolders]. Select the folder in CD-ROM by pushing [Browse] button. The folder location is followings. OS Folder location Windows XP (32bit) \Drivers\32bit Windows 7 (32bit) Windows 7 (64bit) \Drivers\64bit And then push the [Next >] button.

(4) When the search is complete the following screen will be displayed. <Windows XP> Push the [Continue anyway] button to continue <Windows 7> Push the [Install this driver software anyway] button to continue. (5) When installation of the driver is completed, the following screen will be displayed. <Windows XP> Pushing the [Finish] button. <Windows 7> Pushing the [Close] button. (6) The installation of the USB driver is now complete. Next is the installation of the virtual COM port. Install the virtual COM port driver using the same procedure. 1.2 Installation of software Select the \ACT Controller\EN(VER1200)\Setup.exe in CD-ROM. To install the software follow the on screen instructions. When the installation is completed the "ACT Controller Menu" is displayed as an icon. To start software click this icon. Important: Check Confirmation the communication port before starting software 2. Confirmation of communication port The communication port number is needed to set up communication setting between PC and LEC by the ACT Controller Software. The communication port number is automatically allocated for the communication unit by Windows. It is necessary to confirm the communication port number (COM number). This number can be confirmed by the Windows device manager. (1) <Windows XP> Open the Control panel System in the start menu. Select Hardware tab in the upper part of the screen. <Windows 7> Open the Control panel. Select Hardware and Sound.

(2) Push the [Device manager] button in the upper part of the screen. (3) Check the COM port number allocated to SMC serial Port (COM*) displayed in Ports (COM and LPT). In Windows XP example, it is COM6. The COM port number is changed depending on the USB port that is connected to the communication unit. If the USB port connected to the communication unit is changed, the COM port number for the communication setting should also be changed. 3. Start menu The "ACT Controller Menu" icon is displayed on the PC desktop after the software is installed. The following menu is displayed when this icon is double clicked. Select "Normal mode" or "Easy mode"

4. Communication setting When the software is started up in either "Normal mode" or "Easy mode", the software recognizes the connected controller automatically. (Communication setting is necessary for this to happen) Please check the following points before starting communication. The controller that is being used for communication is switched on. The controller and the personal computer are connected through the communication unit. < Normal mode > The following window is displayed when "Action" - "System" - "Setting" is selected from the menu bar. Set the COM port number as confirmed by the 2. Confirmation of the communication port" in the row named Port No. Maximum number of axis COM port Communication rate Confirmed number of axes used. COM port number of communication unit The communication rate to the controller is specified. * The default value of LEC series is 38400 bps. After setting up the communication, select "Action" - "System" - "Reset". The software will then search for the connected controller and PC. If, at start up in "Normal mode" the "Offline" is displayed in the part of the screen shown in the figure below, the controller is not recognized. Check the power supply etc. to the communication port setting, wiring, and the controller. If the controller is connected correctly, "01-***" is displayed instead of "Offline" as shown in the figure below. < Easy mode > If communication is not possible, the communication-setting screen is displayed. The communication setting/connection should be completed as per section 4. Operation is now allowed. 5. Explanation of the function of each mode Refer to the "ACT Controller Help" for explanation of the function of each mode. The "ACT Controller Help" is displayed by selecting the "ACT Controller "- "ACT Controller Help" in the program menu or via the icon on the PC desktop. Notes: Do not turn off the power supply to the communicating controller, or disconnect the cable when the setting software (ACT Controller) is running. Communication is continuous while software is running. If the cable is pulled out while communicating, it causes malfunction of the software.