Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS



Similar documents
Solid-State Timer H3G

Centro-Matic Automatic Lubrication Systems System Controls

Speed Control Relays SX2

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Solid State Timers Type F

RY2 miniature industrial relays

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Multifunction devices

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Multifunction Digital Timer

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power Supplies 3. SDN-P DIN Rail Series

1.44 kw Programmable DC Power Supplies XLN Series

Data Sheet. Electro-mechanical counters Hengstler 800 series

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS

SKR - industry relay

Preset Counter signo 721

Operating Instructions

Digital Pressure Measuring Instrument MDR480

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

General Purpose Relays Types K, R, N, and C

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

NC-12 Modbus Application

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Digital display DA 48

38 Series - Relay interface modules A

*.ppt 11/2/ :48 PM 1

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

38 Series - Relay interface modules A

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

IO-RM3 3-Stage Relay Module

General-purpose Relay

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Thyristor-controlled power supplies and battery chargers

Flow Monitoring System

7.5 Watt AC-DC Switch Power Supply

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Duct Humidity Transmitter

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

SPEED CONTROL SYSTEM

Operating Manual UWAPS-TINY Series

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Unattended Answering Device Instruction Manual

Series Six Plus Programmable Controller

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Telefon (+45) Telefax (+45) Installation and operating manual

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

SELF-POWERED VOLTAGE DETECTING & PROTECTING RELAY

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

PIEZOMETER AIRFLOW MEASURING RING

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

40.3. Control Relays and Timers

60 Series - General purpose relays 6-10 A. Features

User s Manual Before using the inverter, you need to read and save the safety instructions.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

SPST-NO SPDT DPST-NO DPDT

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Single Channel Loop Detector

WINGLIKE ELECTRONICS CO.,LTD

Contents. Document information

British BS 88 Fuses. Introduction

Relays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

SX460. Generator Automatic Voltage Regulator Operation Manual

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

650W Single Output Power Supply

Modular I/O System Analog and Digital Interface Modules

SECTION LOW VOLTAGE LIGHTING CONTROLS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

49 Series - Relay interface modules A. Features

Universal Voltage Terminal Photoelectric E3JM

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

40 Series - Miniature PCB/Plug-in relays A. Features

Physical Specifications (Custom design available.)

Cross-beam scanning system to detect slim objects. 100 mm in

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

mecotron Safety relay ESTOP-2 For emergency stop monitoring

SYSTEM 4C. C R H Electronics Design

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Transcription:

Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation Output Contacts Rated 10A at 120/240 VAC and 30 VDC Timing Ranges: 0 to 9.99, 99.9 and 999 sec., min., and hours Universal Power Supply; 24-240 VAC and 24 VDC 48mm 2 DIN Standard Housing 11-pin Socket Mount or Panel Mount Range & Mode Switches are Tamper Proof when Panel Mounted EEPROM Memory Available as an Option for Applications Requiring Memory 3 Separate Control Inputs: Start, Gate, Reset DIGITAL SETTING The 427 is set digitally by rotating each setting knob. This digital setting allows exact, accurate and repeatable timing cycles. HIGH ACCURACY The 427 utilizes a crystal controlled oscillator which provides 0.1% timing accuracy across all rated voltages and temperatures. FIELD SELECTABLE MODES OF OPERATION An 8 position tamper proof mode switch allows easy selection of any one of eight different timing modes. On Delay Repeat Cycle Signal Interval/Off Delay Signal Off Delay Interval Cycle One Shot Signal On Delay/Off Delay Signal Off Delay (2) UNIVERSAL POWER SUPPLY The 427 can be powered using 24-240 VAC or 24 VDC power, greatly simplifying ordering and inventory management of replacement units. 48mm 2 DIN HOUSING The 48mm 2 (1/16 DIN) housing is compact. The 427 is mounted in an 11 pin round socket. With an optional mounting clip, the 427 can be panel mounted. Positive indication of the setpoint is shown on the front of the 427. Each digit can be changed by rotating the setting knobs. The decimal point and sec./min./hr. range are also clearly displayed. The decimal point and sec./min./hr. select switches are located on the side of the unit, so that when panel mounted, these switches are not accessible to the operator. This tamper proof feature prevents unauthorized or hazardous changes to the timing range from being made. CYCLE PROCESS INDICATION The 427 LED bargraph indicator provides a unique and effective method of cycle progress indication. Off before timing, the first five LED s blink for the first 20% of the timing cycle. After the first 20%, this LED stays on and the next LED blinks. This operation continues for all 5 LEDs until the timing cycle is complete. When timed out, all 5 LEDs remain on providing positive indication to the operator. APPROVALS See Agency Listing on inside back cover of catalog. 83

OPERATION WIRING Operating Power is applied to terminals (10) & (2). Depending upon the Mode of Operation selected and the wiring of the three Control terminals (START, RESET, GATE) the 427 can be started by wiring the START terminal (6) to (3). The 427 can be reset by wiring the RESET terminal (7) to (3). The timing can be temporarily stopped by wiring the GATE terminal (5) to (3). When wiring the Control terminals: (5), (6), (7), the use of high quality signal relay or switch is recommended. Do not apply power to any of these terminals or the 427 may be damaged. Keep the leads to the Control terminals as short as possible and do not route in the same conduit or wiring bundles as load carrying wires. Model: 0427A300F80XX Do not wire external loads in parallel with these Control terminals. See modes of Operation Before starting your design, read the safety statement in the back of the ATC catalog Concerning safety... ATC makes every effort to build a safe product. We try to state specifications accurately, but every product made will eventually fail, so design our products into equipment so they fail safely. Bottom View of Timer MODES OF OPERATION On-Delay Operation (Mode A) When operating power is applied, the time-delay begins. At the end of the time-delay, the output relay energizes and remains energized until reset by removing the operating power. Using the START and RESET control terminals: With operating power applied, timing starts at the leading edge of the start signal. At the end of the timing, the output relay energizes and remains energized until reset by the leading edge of the reset signal, or removal of operating power. 84

Signal Interval/Off Delay (Mode B) When operating power is applied, the preset off time begins. When the off time ends, the output relay energizes and the on time begins. When the on time ends, the relay de-energizes and a new cycle begins. The timer recycles until the operating power is removed, or momentarily enabling the reset. Signal Interval/Off Delay (Mode C) When operating power is applied, the output relay energizes and timing starts when the start switch is opened or closed. When the time setting is reached, the output relay de-energizes. The timer restarts from zero if the start switch transitions during the timing cycle. Signal Off Delay 1 (Mode D) With power applied, the output relay energizes when the start switch is closed. Timing starts when the start switch is opened. At the end of the time delay, the relay de-energizes and the timer resets. Interval (Mode E) When operating power is applied, the output relay energizes and timing starts. At the end of timing, the relay de-energizes and timing stops. The reset, remove the operating power or enable the reset terminal momentarily. 85

Cycle One Shot (Mode F) When operating power is applied, the timing cycle starts. When the time setting is reached the output relay energizes and remains energized. If the operating power is still applied, the timer continues timing and when the time setting is reached again, the output relay de-energizes. Reset is accomplished by removing operating power or closing the reset switch. Signal On Delay/Off Delay (Mode G) When operating power is applied, the timing cycle starts with the opening or closing of the start switch. A. Closing a normally open switch, the timing cycle starts and when the time setting is reached the output relay energizes. Opening the start switch, timing restarts and the relay de-energizes when the time setting is reached. B. Using a normally closed start switch, when operating power is applied, the timer begins the above timing cycle immediately Signal Off Delay 2 (Mode H) With operating power applied, the timing cycle starts and the output relay energizes when the start switch opens. When the time setting is reached, the output relay de-energizes. 86

SPECIFICATIONS MODEL: 427A300F80XX 8 Switch selectable Modes of Operation: A - On Delay B - Repeat Cycle C - Signal Interval/Off Delay D - Signal Off Delay 1 E - Interval F - Cycle One Shot G - Signal On Delay/Off Delay H - Signal Off Delay 2 CONTACT RATING Rated 10 AMPS resistive at 30 VDC or 250 VAC (or less) 1/8 HP @ 120 VAC 1/4 HP @ 240 VAC 240 VA @ 240 VAC LIFE: 10 million operations with no load 100,000 operations with: 10 AMPS at 30 VDC (or less) or 10 AMPS at 250 VAC (or less) @ 50 C CONTACT MATERIAL Cadmium Silver Oxide TEMPERATURE RATING -18 C to 60 C. (0 to 140 F.) NOISE IMMUNITY Showering ARC per NEMA ICS 2-230. In addition, the 427 will withstand a voltage surge of 4500 volts for 50 usec.without damage. MOUNTING 11-pin plug-in base; mounts in any position with retaining clips. Options: Surface mounting DIN mounting socket Panel-mounting adapter kit Plug-on socket POWER REQUIREMENTS Universal power supply - reverse polarity protected 24 to 240VAC, 50/60 Hz; (+10%, -20%) 24VDC (+20%,-20%) AC: Inrush - 1.5 Amps Power required - 1.2 watts DC: Maximum ripple @ 100 Hz - 10% Current required - 50 ma Power required - 1.2 watts F option - Peak inrush current= 2 Amps @ 24 VDC REPEAT ACCURACY +/-0.1% over all rated voltages (crystal controlled) POWER RESET TIME a. 0 to 20 msec power interruption; guaranteed no reset. b. 20 to 65 msec; it may reset (40 msec typical reset) c. Over 65 msec guaranteed to reset WEIGHT 5 oz. (140 g) CONTROL RESET TIME a. Start: 50ms b. Reset: 50ms c. Gate: 50ms DIMENSIONS: INCHES MILLIMETERS Before starting your design, read the safety statement on the inside back cover of the ATC catalog. 87

SERIES 427A TIMER ORDERING CODE BASIC TYPE 427A 300 F 80 XX RANGE 300 0 to 9.99, 99.9, 999 sec., min., hrs. VOLTAGE & FREQUENCY F 24 to 240 VAC and 24 VDC ARRANGEMENT 80 8 operating modes FEATURES XX Standard plug-in, 11-pin round XK Special ACCESSORIES 0000-825-86-00 11 Pin surface/din rail socket 0405-025-07-00 Hold down for above socket 0405-320-02-00 Panel mounting bracket 0314-260-07-00 11-pin plug on socket kit 0000-825-88-00 11 Pin panel socket w/rear facing terminals For prices and further information, consult factory. ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Before starting your design, read the safety statement on the inside back cover of the ATC catalog.