Lighting Control Systems



Similar documents
LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

OMX-RS232 Control Interface

Control Interfaces. GRAFIKR Systems a LUT-DMX

4000 Series Installer s Guide

QSE-CI-DMX Control Interface

BACnet Automation Interface Module (Network Version)

QSE-CI-NWK-E Control Interface

Model SRMD Setra Remote Monitoring Display

HMI display Installation Guide

INSTALLATION INSTRUCTIONS

LIEBERT VNSA Installation Sheet

Application Note #402 Revision B November 2014 Energi Savr NodeTM System Wireless Networks

EMBEDDED ACCESS CONTROL Hardware Installation Guide

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

AXIS T81B22 DC 30W Midspan

Applied Electronics. Commercial Dimming System UPDATE NOTICE

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

USB Rover port USB m Cat 5 Extender. User Guide

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

About the BitStorm 6051 POTS Splitter

Advantium 2 Plus Alarm

Operation and Installation Manual

Remote Power Panels with Breakers

Application Note #537 Revision D August 2015 Solutions for Upgrading from HomeWorks Illumination to HomeWorks QS

12 Volt 30 Amp Digital Solar Charge Controller

BroadBand PowerShield. User Manual

Fire Fighter Phone System Installation Instructions

T-Extender E-Extender

GRX-PWM Pulse Width Modulation Interface

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Architect/Contractor Information Package

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

for DNE-K07 Reference and Installation Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Installation Guide Solar Connect-11

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

HomeWorks QS Processor

Installation and Operation Guide for PD4100 Series Power Control Centers

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Installation & Operation Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

HomeWorks QS Wired Signature SeriesTM Keypads

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

Model 201 Wiegand Touchpad Reader Installation Guide

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

OPERATING INSTRUCTIONS

MechoNet TM Network Interface (MNI) Specification Submittal

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Installation and Operation Guide for PD4000 Series Power Control Center

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

User Guide. HDMI Active Cable Extender. DVI-7370c

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Single Station Remote Alarm

INSTRUCTION MANUAL MODEL PCD-88

TrueAlarm Fire Alarm Systems

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Switching Power Module

Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT. Perfect for ANDROID TM

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

MCR1900 Media Converter 19-Slot Chassis

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Canopy Surge. User Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

ADM1TE 5/30A DIN rail single phase two wire energy meter

Phase-Adaptive Power Module

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

16-Port and 24-Port 10/100 Switches

Installation instructions for Series NRX INCOM communications adapter module

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

8-Port PoE Network Switch

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Water Leak Detection System

T7560A,B,C Digital Wall Module

, User s Manual

Duct Humidity Transmitter

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

UniStream CPU-for-Panel

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

CompactLogix Power Supplies Specifications

MEDMASTER EXTERNAL POWER SUPPLY

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Transcription:

Lighting Control Systems GAFIK 7000P Including... Installation and Maintenance Guide

System Overview Use this guide to successfully install a GAFIK7000, GAFIK6000, or GAFIK5000 lighting control system. This guide describes installing Processor Panels and running low-voltage type Class 2 / PELV wiring, such as the Control Station Device (CSD), Power Panel, User Interface, and Interprocessor Links. See instructions included with all Power Panels for running line (mains) voltage wiring. The GAFIK7000, GAFIK6000, and GAFIK5000 lighting control systems have a central processor that downloads circuit information to the Power Panel Link. Power Panels Processor Panel Control Station Devices (CSDs) Feed Loads Feed Loads GAFIK 7000P, 6000P, or 5000P Control Interface Control Unit Wallstations Power Panel Link (S485 2 ) 125 panels max. Control Station Device (CSD) Link Wiring (S485 2 ) with up to 32 CSDs per link GAFIK 7000P models have 0 to 6 CSD Links GAFIK 6000P has 3 CSD Links GAFIK 5000P has 1 CSD Link Optional S232 (50 ft. (15 m) max) or Modem wiring to equipment by others. Interprocessor Link Wiring (S485 2 ) or (10/100 Base T-Ethernet 1 ) with up to 32 GAFIK7000P s - GAFIK7000 only User Interface Link (10/100 BaseT Ethernet 1 ) or (S485 2 ) to a Computer or Network Interface 1 The Interprocessor Link and the User Interface Link can both enter the processor panel on the same Ethernet wiring. There is only one Ethernet connector per processor panel. Ethernet wiring can be up to 300 ft. (90 m) long. 2 S485 Links can be up to 2000 ft. (610 m) long when using the correct wire. See the S485 Wiring Overview for more details. 2 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

Table of Contents Step-by-Step Instructions Page Install System System Overview.........................................................2 Processor Panel Model Numbers.............................................4 STEP 1: Mount Wallboxes.........................................................5 STEP 2: Mount Processor Panels...................................................6 Processor Panel Overview..................................................8 S485 Wiring Overview...................................................10 STEP 3: Processor Panel Line-Voltage Wiring.........................................12 STEP 4: CSD Link and Power Panel Link Wiring.......................................13 STEP 5: User Interface Link Wiring.................................................14 STEP 6: Interprocessor Link Wiring (GAFIK 7000P only)................................15 STEP 7: Set CSD Link Address Switches............................................16 STEP 8: Set Processor Panel Address Switches.......................................17 STEP 9: Address Power Panels....................................................18 STEP 10: Install Control Station Devices..............................................19 Start Up System STEP 11: Activate System.........................................................20 Trouble Shooting Guide...................................................21 Maintain System Maintenance...........................................................22 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 3

Model Numbers of Processor Panels G7-A-0000-0-120 100: 100 V 50/60 Hz, 15 A 120: 120 V 50/60 Hz, 15 A 230: 220 240 V 50/60 Hz, 10 A 0: No Modem option included - GAFIK 7000P only M: Integrated modem and S232 interface included 0000: No CSD Link - GAFIK 7000P only W000: 3 CSD Links with 32 Control Station Devices max per link (96 total) - GAFIK 5000P has only 1 CSD link WW00: 6 CSD Links with 32 Control Station Devices max per link (192 total) - GAFIK 7000P only : etrofittable panel (includes subplate)?: Other options available - contact Lutron A: U.S. English version?: Multiple languages available - contact Lutron 7: GAFIK 7000P Processor Panel 6: GAFIK 6000P Processor Panel 5: GAFIK 5000P Processor Panel System Information Processor Information Type Processors Name CSD Links Zones GAFIK7000 up to 32 GAFIK 7000P up to 6 up to 512 GAFIK6000 1 GAFIK 6000P 3 512 GAFIK5000 1 GAFIK 5000P 1 128 4 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

Step 1 Mount Wallboxes Use wallboxes with a minimum depth of 2-3/4 in. (70 mm) for Control Station Devices (CSDs) Multigang installations may require spacers between wallboxes Mount wallboxes between flush and 1/8 in. (3 mm) below finished wall surface Finished wall should not have gaps around the wallbox of greater than 1/8 in. (3 mm) Ground metal Wallboxes whenever possible 1/8 in. (3 mm) max. 2-3/4 in. (70 mm) min. Wall Wallbox Wallbox Mounting Frame Drywall Mounting of a single-gang US wallbox shown. See the instructions sent with each individual CSD for mounting requirements and instructions. Mounting frame orientation of a single-gang EG product shown. Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 5

STEP 2 Mount Processor Panels emove the subplate, if applicable, to access mounting holes. Keep the screws and protect the subplate from damage and dirt until it is returned to the enclosure. Dimensions and Conduit Entry Front View 14.38 in. (365 mm) ight Side View Top View (No Class 2 / PELV Entry) 1.5 in. (38 mm) Dedicated Feed Wiring 6.475 in. (164 mm) 3.25 in. (95 mm) Screws (4) for hanging subplate 6.0 in. (152 mm) 2 in. (51 mm) 3.875 in. (98 mm) 0.5 in. (13 mm) and 0.75 in. (19 mm) conduit knockouts (18) 34.75 in. (883 mm) 22 in. (559 mm) 21.27 in. (540 mm) Surface Mounting Holes (4) Flush Mounting Holes (4) Bottom View (Class 2 / PELV Entry Only) 0.5 in. (13 mm) conduit knockouts S232 Input 6 in. (152 mm) Power Panel Link Interprocessor Link Control Station Device (CSD) Links 8.63 in. (219 mm) 2.875 in. (73 mm) 1.75 in. (44 mm) User Interface Link Notes - Not all processor panels use a subplate Make sure relative humidity is less than 90% non-condensing einforce wall structure, if necessary. A processor panel weighs up to 50 lbs. (22 kg) 6 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

STEP 2 (Continued) Mount Processor Panels ecess or Surface Mount the enclosure as per the following diagrams. ecess Mount Surface Mount Wall shown cut away Dedicated Feed Dedicated Feed Class 2 / PELV wiring Class 2 / PELV wiring Space off of the wall as noted 16 in. (410 mm) Front View Side View Front View Side View Water Damages Processors! Install this processor in a location where it will not get wet. Surface mount as shown! Back surface must be 1/8 in. (3.2 mm) away from the wall. Subplate mounting screws will protrude 1/8 in. (3.2 mm) behind the panel Use only the four holes indicated when surface mounting - other holes are for mounting the subplate Install Subplate If there is a subplate, install it using the four screws shipped with the mounted enclosure. Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 7

Processor Panel Overview Line voltage supply eceptacle - for Lutron use only Panel Power Switch Class 2 / PELV Transformers (up to 6) Power Supply Board Main Board Assembly - See next page CSD Link D CSD Link E CSD Link F CSD Link A CSD Link B CSD Link C S-232 Telco Modem / S232 Card UI Link AUX Link IP Link PP Link N/C Ethernet LNK G7000 ADD Processor Panel Address Switch Ethernet Port GAFIK 7000P with six CSD Links and Modem / S232 Interface shown 8 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

Processor Panel Overview Main Board Assembly CSD Link D CSD Link E CSD Link F S-232 Telco CSD Link A CSD Link B CSD Link C UI Link AUX Link IP Link PP Link N/C Ethernet LNK G7000 ADD Notes - Abbreviations are as follows: CSD = Control Station Device UI = User Interface AUX = Auxilliary (no connection) IP = Interprocessor PP = Power Panel GAFIK 7000P with six CSD Links and Modem / S232 Interface shown Warning - This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 9

S485 Wiring Overview S485 wiring is the Class 2 / PELV wiring used for the following links: Control Station Device Link(s) Power Panel Link Interprocessor Link (if using the S485 connection option) User Interface Link (if using the S485 connection option) LT-1 2000 ft (600 m) max. Daisy chain wiring - do not home run wiring. LT-1 Specifications and Notes - Do not run S485 wiring with line (mains) voltage wiring Each link must be daisy-chained. Do not home run wiring The Processor Panel does not need to be at an end of any S485 Link Use a Link Terminator at the beginning and end of each S485 Link Connections to numbered terminals are wired 1 to 1, 2 to 2, 3 to 3, etc... throughout the link Total length of any S485 wiring may not be more than 2,000 ft. This distance is based on proper shielding on the twisted shielded pair, #12 AWG wire to terminal 1 and terminal 2 of the Control Station Device (CSD) Link, and the use of link terminators (LT-1s) at each end of each link. If smaller wire is used, the max CSD Link length must be de-rated - see chart Terminal 1 & 2 Wires Sizes #12 AWG #14 AWG #16 AWG #18 AWG 2.5 mm 2 1.0 mm 2 Max. CSD Link Length 2000 ft. (610 m) 1400 ft. (425 m) 900 ft. (275 m) 600 ft. (180 m) 450 m (1500 ft.) 200 m (650 ft.) S485 communication is a stream of 5V data that all of the products on the link understand. The details listed on this page help to keep the data understandable: - proper shielding blocks noise and has low capacitance (which would reduce the signal) - LT-1 s stop the end of the link from bouncing the signal back onto the link - daisy-chaining prevents the data from being divided, and keeps the number of ends of the link to two - #12 AWG wire minimizes the voltage drop along the link Notice If Link Terminators (LT-1) are not used, or improper wiring topology is employed, the system will not communicate. 10 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

S485 Wiring Overview Wiring Notes: Two #12 AWG (2.5 mm 2 ) wires cannot fit into most connectors on the S485 link. Use a screw on connector (or other approved connector) to T-tap a #18 AWG (1.0 mm 2 ) wire to each connector terminal, as needed. Make this T-tap in the Wallbox in order to keep the length of the new #18 AWG (1.0 mm 2 ) wire(s) as short as possible Connect the uninsulated Drain/Shield wire(s) to terminal D whenever present. If there is no terminal D, connect the two Drain/Shield wires together, making a continuous shield throughout the link. If the connector at the end of the link does not have a D terminal, terminate the shield and let it float Do not allow any part of the shield to touch ground (earth) or any electrical circuitry CSDs are expected to mount into metal Wallboxes that are connected to grounded conduit. Grounding the metal mounting plate helps keep Electrostatic Discharge (ESD) from affecting the S485 link 4 3 2 1 Control Station Device (CSD) connector 1 #18 AWG (1.0 mm 2 ) Drain / Shield 2 #12 AWG (2.5 mm 2 ) 2 #12 AWG (2.5 mm 2 ) Approved sources of wire include: Twisted-Shielded Pair (Data Link) only: Belden #9461 Alpha #2211 One-cable solutions (Data Link, Control Wiring, and Sense Line in one cable): Lutron G-CBL-46L-500 (non-plenum) Lutron G-PCBL-46L-500 (plenum) Belden, Alpha, Liberty, and Signature have approved cables. Ask for GAFIK Eye Cable Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 11

STEP 3 Line Voltage Wiring of Processor Panel Make sure line voltage feed wiring enters the processor from the top right un a dedicated feed circuit - see model number for feed rating un wiring so that line (mains) voltage is separate from Class 2 / PELV wiring eceptacle for Lutron use only (120 V shown) GOUND/EATH (green) HOT/LIVE (black - 100 V, 120 V ) (brown - 230 V ) NEUTAL (white - 100 V, 120 V ) (blue - 230 V ) 12 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

CSD Link D CSD Link A UI Link CSD Link E CSD Link B AUX Link CSD Link F CSD Link C IP Link PP Link N/C S-232 Telco Ethernet LNK G7000 ADD 1 2 3 4 5 6 STEP 4 CSD and Power Panel Link Wiring Control Station Device (CSD) Link Control Station Devices Last Control Station Device on Link 123456 1 2 3 4 5 6 I Ceiling eceiver CSD Link 4 3 2 1 1 2 3 4 Link Terminator (LT-1) 3 4 Control Wiring (2) #12 AWG (2.5 mm 2 ) 1: Common 2: +VDC Data Link (1) shielded, twisted pair #18 AWG (1.0 mm 2 ) 3: 4: D: Drain wire in shield - Connect together to make one continuous link shield. Keep away from ground and control electronics. 3 4 Link Terminator (LT-1) Processor Panel - GAFIK 7000P shown PP Link N/C Power Panel Power Panel Last Power Panel on Link 1 Common 2 N/C 3 4 D Drain 5 Sense Line 1 Common 2 N/C 3 4 D Drain 5 Sense Line 1 Common 2 N/C 3 4 D Drain 5 Sense Line Power Panel Link Link Terminator (LT-1) 3 4 Control Wiring (1) #18 AWG (1.0 mm 2 ) 1: Common 2: No Connection Data Link (1) shielded, twisted pair #18 AWG (1.0 mm 2 ) 3: 4: D: Drain wire in shield - Keep away from ground and all electronics Link Terminator (LT-1) 3 4 Emergency / Essential Sense Line (1) #18 AWG (1.0 mm 2 ) 5: Sense Line Notes: It is not necessary to have the processor panel at the end of any S485 link The Power Panel Link s Sense Line is used whenever there is a panel being supplied by an Emergency / Essential feed. See Power Panel instructions for more details See S485 Overview for approved cable options Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 13

CSD Link D CSD Link A UI Link STEP 5 CSD Link E CSD Link B AUX Link CSD Link F CSD Link C IP Link PP Link N/C S-232 Ethernet LNK Telco G7000 ADD LUT LIGHTING CTOL S485 POT User Interface Link Wiring S485 Option UI Link Network Interface shown is an Ethernet to S485 converter (G7-A-NWK-E-D-x). The Wall Jack shown is an NTOMX-485J-WH. Processor Panel - GAFIK 7000P shown Computer Link Terminator (LT-1) S485 Data Link from Network Interface to (each) processor: 3 4 (1) #18 AWG (1.0 mm 2 ) 3 4 1: Common 2: No Connection (1) shielded, twisted pair #18 AWG (1.0 mm 2 ) 3: 4: D: Drain wire in shield - Keep away from ground or circuitry. Link Terminator (LT-1) Ethernet Data Link from Computer to Network Interface: (1) Category 5 UTP (unshielded, twisted pair) Cable Ethernet Option 1 with Network Switch or Hub Computer GAFIK 7000P Ethernet Data Link from Computer to Network Interface to processor(s): (1) Category 5 UTP (unshielded, twisted pair) Cable The Wall Jack shown is an NT-6PS-WH with an J45 connector. Ethernet Option Direct to Computer Ethernet Data Link from one Computer to one processor: (1) Category 5 UTP (unshielded, twisted pair) Crossover Cable Computer Notice Wiring distance for any Ethernet Data Link is 300 ft. (90 m) max. Use the S485 option for longer distances. 1 The Interprocessor Link and the User Interface Link can both enter the processor panel on the same Ethernet wiring. There is only one Ethernet connector per processor panel. 14 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

CSD Link D CSD Link A UI Link CSD Link E CSD Link B AUX Link CSD Link F CSD Link C IP Link PP Link N/C S-232 Ethernet LNK Telco G7000 ADD STEP 6 Interprocessor Link Wiring Processor Panel - GAFIK 7000P only S485 Option IP Link N GAFIK 7000P GAFIK 7000P GAFIK 7000P IP Link IP Link IP Link Link Terminator (LT-1) 3 4 3 4 Control Wiring Data Link (1) #18 AWG (1) shielded, twisted pair #18 AWG (1.0 mm 2 ) Link (1.0 mm 2 ) 3: Terminator 1: Common 4: (LT-1) 2: No Connection D: Drain wire in shield Ethernet option Ethernet Data Link from an Ethernet Switch or Hub to one processor per port: (1) Category 5 UTP (unshielded, twisted pair) Dedicated Ethernet Hub or Switch To additional GAFIK 7000P s and/or computers, if applicable Notes: Each Ethernet Data Link can be a maximum of 300 ft. (90 m) long The Interprocessor Link and the User Interface Link can both enter the processor panel on the same Ethernet wiring. There is only one Ethernet connector per processor panel Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 15

STEP 7 Set Control Station Device Address Switches Each device along the Control Station Device (CSD) Link must have a unique address ranging from 1 to 32. The Address Switches may have been pre-set to give the address shown on the job drawings. Job drawings may show: 2B3 Address 3... on CSD Link B... in Processor 2 (omitted if only one processor) If the Address Switches were not pre-set (all set to address 1), assign each CSD a unique address and document its location and description. If needed, refer to the instructions for each CSD to help locate its Address Switches. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Address Switch Settings Chart - shows how to set the Address Switches to get a specific address. Note GAFIK Eye Control Units (G-46xx-x-xx) do not have Address Switches but must be programmed with a unique address(es). See separate instructions sent with each Control Unit. Notice! Do not install a CSD without confirming that the Address Switches have been set. 16 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

CSD Link D CSD Link A UI Link CSD Link E CSD Link B AUX Link CSD Link F CSD Link C IP Link PP Link N/C S-232 Ethernet LNK Telco G7000 ADD STEP 8 Set Processor Panel Address Switches If there is only one processor panel in the system, leave its address as shipped (default is address 1). If there are two or more processor panels on the Interprocessor Link, each must have a unique address, ranging from 1 to 32. The Address Switches may have been pre-set to give the address shown on the job drawings. Use the Address Switch Settings Chart, on the previous page, to see how to set the Address Switches to get a specific address. Panel Address Processor Panel - GAFIK 7000P shown. Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 17

STEP 9 Address Power Panels Each power panel must have a unique address on the Power Panel Link. Power Panels are not pre-addressed by the factory. Without the unique address, the Processor Panel cannot download system settings to the Power Panel. efer to job drawings to see the intended address of each power panel. Set the address by manually programming the Circuit Selector within each Power Panel. See instructions provided with each Power Panel for this procedure. If the job drawings do not include an address, document the Power Panel s location and Model Number for each address. This information will be needed to set up the system properly. 5 C D Common 24VFW Link A Link B Data A OK Drain Sense Power Circuit Level Load Type (See Instructions) Low-End Trim High-End Trim Link Link A B Circuit Value Comm 1 2 3 4 5 Data B OK Drain 5 C D SELECT CICUIT VIEW VALUE SELECT VALUE SELECT VALUE DISPLAYED Zone Assignment w/ Circuit Schedule Zone Assignment w/ Zone CaptureTM Address('Ad' Displayed) Power Panel Address on a Circuit Selector 18 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

STEP 10 Install Control Station Devices After confirming that each Control Station Device (CSD) is addressed, install them into the wallboxes. See the instructions sent with each individual CSD for installation instructions. CSD Link CSD Mounting Screws Adaptor Mounting Screws CSD Link CSD Mounting Screws Adaptor Mounting Screws Single-gang US Wallbox CSD Faceplate Adaptor Faceplate Single-gang EG Wallbox Mounting Frame Carrier Faceplate Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 19

STEP 11 Activate System Once all links are installed and wiring is verified, turn the Processor Panel power switch. After 10 seconds, compare the diagnostic LEDs to those listed in the Troubleshooting Guide. Power Switch CSD Link D 1 OK 2 OK 3 OK CSD Link D CSD Link E CSD Link F CSD Link A CSD Link B CSD Link C S-232 Telco UI Link AUX Link IP Link PP Link N/C Ethernet LNK G7000 ADD UI Link PP Link N/C GAFIK 7000P with six CSD Links and Modem / S232 Interface shown 20 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

Troubleshooting Guide LED Diagnostics Location of LED Name Normal Operation Problem Indicator / Possible Cause Power Board On No power from transformer - check if power feed and switch are On CSD Link On Flashes apidly On Short on CSD Link - wire 2 to 1 or ground Processor in self-test - contact Lutron No database loaded Processor Panel PP Link IP Link Flashes apidly Flashes Dimly On Dim On Dim No database loaded No data received - Power Panel not addressed or check wires 1, 3, and 4 No database loaded No data received - Link not used or check wires 1, 3, and 4 UI Link On Irregular Flash Irregular Flash Short on UI Link - wire 2 to 1 or ground No communication to computer No communication from computer Ethernet LNK Irregular Flash On No activity on network, if connected No network detected - check wiring CSD Front of CSD none On (if button pressed) Flash No power - wires 1 and 2 miswired, or If On then, CSD not programmed Those that flash have the same address, or Miswire - check wires 1, 3, and 4 Power Panel Circuit Selector Dimmer / Module DATA Value none Flashes 1 per sec On OK Flashes 1 per sec apid Slow apid Miswire of wires 3 and 4 Control Breaker off Circuit Selector timed out - press any button No communication from Circuit Selector Shorted Triac - contact Lutron LED problem indicators: Flash on CSD is all LEDs turning On for approx. 1 second, then off 3 seconds apid on a Circuit Selector is any rate faster than the Heartbeat of once per second apid = Flutter on a Dimmer/Module is one LED turning On approx. 5 times per second Slow on a Dimmer/Module is one LED turning On approx. once per 7 seconds Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 21

Maintain the System Lutron products are designed to have minimal maintenance requirements. Control Station Devices (CSDs) Clean front surface with a soft towel moistened with a mild soap solution (non-ammonia based). Clean approximately every six months. Do not spray cleaning solution directly at any CSD. Power Panels Visually inspect installation periodically - keep air flow clear of obstructions. Power panels generally need 12 in. (300 mm) of clearance above, below, and in front of the enclosure. Processor Panels There are no maintenance requirements for these products. Clean the front cover as needed. Other See instructions supplied with individual products for any other recommendations for maintenance. Danger Turn power off before working on any load. See instructions supplied with individual Power Panels. Warning When working on any load (such as rewiring a load), replace the bypass jumpers to protect the Power Panels until the load is proven. Danger Any liquid entering products with line (mains) voltage may reach internal components, cause personal injury, damage the equipment, and void the warranty. 22 Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System

Notes - Installation of GAFIK5000 / GAFIK6000 / GAFIK7000 System 23

Contact Information Warranty Internet: www.lutron.com E-mail: product@lutron.com WOLD HEADQUATES Lutron Electronics Co. Inc., TOLL FEE: 1.800.523.9466 (U.S.A., Canada, portions of Caribbean) Tel: 1.610.282.3800 Fax: 1.610.282.3090 GEAT BITAIN Lutron EA Ltd., Tel: +44.207.702.0657 Fax: +44.207.480.6899 GEMANY Lutron Electronics GmbH Tel: +49.309.710.4590 Fax: +49.309.710.4591 JAPAN SALES OFFICE Lutron Asuka Corporation Tel: +813.5405.7333 Fax: +813.5405.7496 HG KG SALES OFFICE Lutron GL (Hong Kong) Tel: +852.2104.7733 Fax: +852.2104.7633 SINGAPOE Lutron GL (Singapore) Tel: +65.220.4666 Fax: +65.220.4333 LIMITED WAANTY Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter d., Coopersburg, PA 18036-1299, postage pre-paid. This warranty is in lieu of all other express warranties, and the implied warranty of merchantability is limited to one year from purchase. This warranty does not cover the cost of installation, removal or reinstallation, or damage resulting from misuse, abuse, or improper or incorrect repair, or damage from improper wiring or installation. This warranty does not cover incidental or consequential damages. Lutron s liability on any claim for damages arising out of or in connection with the manufacture, sale, installation, delivery, or use of the unit shall never exceed the purchase price of the unit. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This product may be covered by one or more of the following U.S. patents: 4,797,599; 4,803,380; 4,825,075; 4,893,062; 5,030,893; 5,191,265; 5,430,356; 5,463,286; 5,530,322; 5,808,417; DES 308,647; DES 310,349; DES 311,170; DES 311,371; DES 311,382; DES 311,485; DES 311,678; DES 313,738; DES 335,867; DES 344,264; CES 370,663; DES 378,814 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, GAFIK6000, and GAFIK Eye are registered trademarks; GAFIK5000, GAFIK7000, and 2Link are trademarks of Lutron Electronics Co., Inc. 2004 Lutron Electronics Co., Inc. Lutron Electronics Co., Inc. Made and printed in U.S.A. P/N 032-120 ev. A - 2/19/04