Decontamination Showers



Similar documents
Laminar Flow Cabinets

LAMINAR FLOW FOR ALL YOUR NEEDS

Laminar Flow Cabinets and Workstations

Risk Assessment: Biosafety Cabinet

Series 18 Pass Thru Air Lock Cleanroom Entry System

Chemical Fume Hoods. Environmental Health and Safety

Biosafety Level 2 (BSL-2) Safety Guidelines

ASTCCR2 - SQA Unit Code H Carry out and complete clean-room cleaning operations

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

Procedures for the Effective Use of Biological Safety Cabinets

Biosafety Program University of Colorado. BSL-1 Audit Checklist

CONTROL METHODS. There are five ways to control the release of asbestos fibers:

Laboratory Design & Construction Guidelines

Biosafety Spill Response Guide

Multi-pollutant control solutions for coal based power plants

Lead Exposure Management Plan

Appendix J IBC Biohazard Spill Management Plan

Guidance on safe use of Autoclaves

Bird and bat droppings

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Standard Operating Procedure for Dacarbazine in Animals

PPG SUPPLIER DEVELOPMENT ASSESSMENT

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Cleanroom Solutions Ltd T: F: E: W:

UBC Plant Operations Asbestos Work Procedures April 2004

Data Centre and Server Room Technical Cleaning

STANDARD OPERATING PROCEDURES SPILL RESPONSE AND CLEAN-UP OUTSIDE BIOSAFETY CABINET

Preparing the Work Area

PERSONAL PROTECTIVE EQUIPMENT (PPE)

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

SPILLS & SPILL KITS. Spills -General Guidelines:

GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

Biosafety Level 2 Criteria

Case Study: Successful Decontamination of an HVAC System s Ductwork Using Chlorine Dioxide Gas

DUST AND DEBRIS MANAGEMENT PROCEDURES HPD HOUSING REHABILITATION PROGRAMS

Excerpts from EPA s Mold Remediation in Schools and Commercial Buildings

Hazardous Drug. Cleanroom. Standards

Decontamination and Waste Management

Decontamination Units

Biosafety Guidelines. 5. Pipetting Mechanical pipetting devices must be available and used. Mouth pipetting is prohibited.

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

ASBESTOS MANAGEMENT PLAN. Borough of Poole Transportation Services, Property Management, Civic Centre, Poole, Dorset BH15 2RU

IEQ-15 Air Distribution System

BSL3 and BSL4 Autoclaves. Laboratory Line

Required Biosafety Level Three (BSL-3) Practices, Procedures, Facilities, and Safety Equipment For BSL-3 and BSL3/2 Laboratories

Containment Solutions

Standard Door Specification

Knowledge and Awareness of Proper Waste Disposal and Routine Biosafety Measures Among HealthCare Workers in Karachi, Pakistan (JUW-BEP-BSAP Project)

Chemical Spill Response Guideline

Tel: Sales: STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK

Lead Management. Presented by: Gary Chinn (815) President, Best Technology Systems

CONTAMINATION CONTROL IN HOSPITALS. Isabelle Pautrel Ingénieur Clean Concept Patriarche & Co i.pautrel@patriarche.fr

THE IDEAL SOLUTION SHELVING. Sales Telephone: Sales Fax:

BSL 1 Laboratory Biosafety Manual

Specifications for Removal and Replacement of Water Damaged/Mold Impacted Materials

Re: Addendum to Preliminary Water Damage Report, Mendocino Public Health Branch, 1120 South Dora Street, Ukiah, CA

UI Procedures for Asbestos Management

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

ASBESTOS MANAGEMENT PROGRAM

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

Best Practices for Handling Nanomaterials in Laboratories

BIO MEDICAL WASTE MANAGEMENT

PAINT BOOTH LIGHTING

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

EMERGENCY EYE WASH FACILITY POLICY. Under the Occupational Health and Safety Regulations of the Province of Newfoundland and Labrador

Laboratory scale mixers

BOSTON COLLEGE ENVIRONMENTAL HEALTH AND SAFETY LABORATORY GUIDE FOR RENOVATIONS, REMODELS, MOVES AND TERMINATIONS

CHILDCARE SETTINGS. Childcare Settings

Range Equipment HVAC Design & Supply Modular Ranges

UniMax Large Floor Mount (Walk-In) Fume Hoods

Vacuum drying oven for non-flammable solvents

Administrative Procedure

Guidance sheet 4: Chemical Spill Management

SECURITY LATCH TM SIMPLE, SAFE & SECURE

Carnegie Mellon University s Policy and Procedures for Recombinant and Synthetic Nucleic Acid Materials Spills

Procedures for Cutting and Handling of Asbestos Cement Pipe. City of Richmond Public Works Operations

Genett Group, Inc. Genett Group, Inc. Anti Microbial Technology. Hospitality Schools Hospitals Construction Remediator Assessor

Laboratory Biosafety Level 3 Criteria

Infection Control in the Dental Practice through Proper Sterilization

3M Personal Safety Division E C O R D. Cartridge. Filter. and. Guide. User Information to Help Optimize Protection

ASBESTOS AWARENESS IN THE WORKPLACE. This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

MOLD REMEDIATION KEY STEPS

Removing asbestos in workplaces

Medical Waste Autoclaves. Medical Waste Autoclaves

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you

ATS-SOI-5910 Page: 1 of 7. Approval Block. Prepared by: Signature Date. Evan Parnell 04 AUG Reviewed by: Signature Date. Brian Flynn 04 AUG 2014

Transcription:

Decontamination Showers

PBSC Operator Over suit Decontamination: API powders from routine operations contaminate over suit / work ware/ppe: Your Facility Could be at Risk: Risk 1: Cross contamination to other products Risk 2: Exposure of staff to API particles during change out /de-gowning The PBSC Decontamination Material Transfer with no loss of facility Shower integrity: has been proven to minimise these Risks Effective API Encapsulation

PBSC Operator Over suit Decontamination: Process generates API Exposure PBSC Decontaminate API Exposure Exposure Risk Reduction

PBSC Decontamination Systems: PBSC De-Con Shower Range Air showers (Personnel) Fogging Showers (Personnel) Bio-Decon (Personnel) Bio-Decon (Materials) 20 Year Experience

PBSC Decontamination Systems: HPV gassing: Material Decontamination Chemical Fogging Shower: Bio-Decontamination Fogging Misting Shower Decontaminates Water Proof PPE PBSC Fogging Shower Encapsulates API s Tyvek type PPE Personnel (PPE) Decontamination PBSC Air Shower Not Suitable for API s Hierarchy Of Decontamination

PBSC Air Shower Shower Provides General Purpose De-Dusting of PPE Ideal for removal of dander and particulate Prior to entry into Clean Facility Not recommended for removal of occupational exposure Proven Technology

PBSC Ultra-Sonic Fogging Shower Proven Technology

PBSC Ultra Sonic Fogging Shower Encapsulates hazardous API with out wetting Thru Suit Proven Technology

PBSC Ultra-Sonic Fogging Shower Ultrasonic fogging of contaminated surfaces results in a low turbulence wetting fog that encapsulates API particles that contaminate work suits Why Ultrasonic Fog?

PBSC Ultra-Sonic Fogging Shower Ultrasonic Fogging Nozzle

PBSC Decontamination Showers Key Features The PBSC Hinge: solid stainless steel hinge in 304 or 316 stainless steel. The PBSC Door seal system: Silicone rubber perimeter seal No visible fixings No contamination trap cgmp compliant The hinge is purpose built for clean room environments with a robust design, providing low maintenance and clean finish. Key Features

Shower Door Interlocks for Maximum Security: When Access Control is Critical. Rely on PBSC: Facility Security

PBSC BSL Chemical Fogging Shower Bio-Decontamination

PBSC BSL Chemical Fogging Shower Why is PPE decontamination needed? To assure that active biological organisms do not breech the facility containment line during personnel exit. How is bio-decontamination carried out? The PBSC fogging system introduces a chemical disinfecting fog that encapsulates biocontamination on the PPE suit and over a pre-determined dwell time effects a kill* on the organisms present. How is the bio-decontamination validated? PBSC will support site SHE team with execution of Bio-indicator tags and similar performance monitoring agents to establish log reduction with/without Biodecontamination * Kill factor dependant on cycle development Additional questions will be fielded by PBSC technical team: Proven Technology

PBSC BSL Chemical Fogging Shower Proven Technology

PBSC BSL Chemical Fogging Shower Proven Technology

PBSC BSL Chemical Fogging Shower Proven Technology

PBSC Decontamination Shower Construction Decon Shower Type Air Shower Fogging/Fogging Misting/Chemical Fogging Size Range 55 x 55 x 84 high (nominal) 55 x 55 x 84 high (nominal) Maximum Clear Size Construction type Door type Available Features Height: 72 H Width Via single door 32 W Phenolic Resin construction Epoxy Coated Carbon Steel 304/3b finish Stainless Steel 316/3b finish Stainless Steel (Other materials available to order) Interlock type Mag lock Electrical codes to suit site standards Glass panel with fixing free PBSC hinge Phenolic panel with fixing free PBSC hinge Stainless door with fixing free PBSC hinge Shelving Waste container bag out HEPA filtration/hvac connections Lighting Electronic access control Height: 72 H Width Via single door 32 W Phenolic Resin construction Epoxy Coated Carbon Steel 304/3b finish Stainless Steel 316/3b finish Stainless Steel (Other materials available to order) Interlock type MAG LOCK Electrical codes to suit site standards Glass panel with fixing free PBSC hinge Stainless Steel door with fixing free PBSC hinge Bio-Decontamination Shelving Bag/container supports HEPA filtration/hvac connections Lighting Electronic access control Construction Detail Shipping Weights: Contact Factory Contact Factory

PBSC HPV Bio-decontamination - Materials Material Bio Decon

PBSC Decontamination Products Personnel Decontamination Five Decontamination Regimes dependant on contaminant Proven Effectiveness at reducing PPE Contamination levels Proven Reduction in Bio-Contamination Electronic Door Interlocks Epoxy Steel or Stainless steel constructions Shelving or container holders Material Decontamination HEPA filtration HVAC connections HPV Decontamination / Inflatable Door Seals Formaldehyde Decontamination with Prep to change over to HPV Further Technical Information: UK & Worldwide +44 1484 354 500 USA +1 888 554 5885 Options