BB2/PSR & QB2/PSR PRESSURE CONTROL VALVES. BB2 Control Valve Electrical Inputs & Monitor Outputs. Zero/Span Access Cap. QB2 Control Valve.



Similar documents
Fluid Power and Fluid Control Solutions For Tire Manufacturing

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Model SRMD Setra Remote Monitoring Display

Electronic Pressure Switch EDS 300

Part I - Installation

Advantium 2 Plus Alarm

WHOLESALE DIRECT INC WEST 65TH STREET

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

AMS-1000 Multi-Channel Air Management System for Boost Control

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Models SFP33 & SFP32 Pressure Transmitters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

3M Wrist Strap and Footwear Tester 740. User s Guide

Electronic Pressure Switch EDS 3000

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Digital inductive conductivity transmitter

INTMOD485-LH Protocol Converter

SDX Submersible Depth Transmitter User Manual

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Utility Distribution Systems

Original instructions Tina 3A/Aps Adaptor unit

Absolute Rotary Encoder E6CP

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Technical Data. Installation

DPI 260 SERIES: Digital Pressure Indicators

HIH-4000 Series Humidity Sensors

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

15/40/80CN Series Coreless Medium Pressure Filters

LED...A Q Series Sealed High-Intensity

Model 111 Mass Flow Instruments

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Model 43. Precision Low Profile Load Cell DESCRIPTION FEATURES

OEM-EP Pressure Controllers

i ChatterBox! Motorcycle Security

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Series 6000 Torque measured metal bellow coupling

The Do s and Don ts of Pressure Transducers

PRODUCT PROFILE FEATURES

PK5500 v1.1 Installation Instructions

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

How To Use A Cdm250 Digital Multimeter

PTU Series Ultrahigh-Purity Pressure Transducers

Streaming Potential System (SPT1000, SPD1000)

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

How To Power A Schen

Tina 2A/B Adaptor unit

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Fiber Optics and Liquid Level Sensors Line Guide

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Water Leak Detection System

Heavy Duty Pressure Sensors/ Transducers Line Guide

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ER3000 Electronic Pressure Controller. User Manual

InHome Water Leak Detection Package

Line to Refrigerator Ice/Water Dispenser

mpm DIN CONNECTORS

PS/2 Extender USER MANUAL.

Color Mark Sensor with Red or Green LED E3S-VS

INSTRUCTION MANUAL MODEL PCD-88

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

CQM1-SF200/CS1W-SF200

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Ceiling Mount Air Handler Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

PEDAL POWER. User s Manual

ADM1TE 5/30A DIN rail single phase two wire energy meter

Centro-Matic Automatic Lubrication Systems System Controls

INSTALLATION AND OPERATING INSTRUCTIONS

ABB Drives. User s Manual HTL Encoder Interface FEN-31

USER MANUAL. Kramer Electronics, Ltd. Models:

AUTOMOTIVE LED LIGHT CATALOG

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

STC 3S A Series Solenoid Valves

WORLD-BEAM QS30 Sensors

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

=============================== WARNING

RGC-IR Remote Gas Calibrator for IR400

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

FEATURES Temperature-compensated magnetics Miniature plastic package Low voltage: 3.8 V operation

4-20mA Current Transmitter with RTD EXCITATION AND LINEARIZATION

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

VSO MAX HP High Flow Proportional Valve

Transcription:

BB2 Control Valve lectrical Inputs & Monitor Outputs Zero/Span Access Cap QB2 Control Valve Supply Pressure xternal Feedback Controlled Pressure Proair Volume Booster Supply Pressure Controlled Pressure BB2/PSR & QB2/PSR PRSSUR CONTROL VALVS

FATURS BNFITS Closed loop electronic control of pressure Quick response Immune to shock and vibration Mounts in any position QB NMA 4 anodized enclosure C approved Can be field recalibrated Analog or BB digital command option Non air consuming in steady state Control pressure up to 200 psig, flow up to 700 scfm Capable of accepting feedback from external sensors liminates time consuming manual regulators Increases productivity by reducing cycle times Can be mounted directly on the machine Simplifies installation and design Withstands industrial environments Suitable for uropean installations Saves costly downtime Allows many control options Reduces noise and saves energy Accurate pressure control at high flow rates Closed loop control of force, torque, vacuum, position, and flow APPLICATIONS Automotive manufacturing Instrumentation Spray painting Resistance welding Paper manufacturing Food processing Metal processing nvironmental waste management Controller A QB2 mounted on a PSR series regulator is controlling the pressure in a plastic accumulator tank molding application. A DS series pressure transducer is providing second loop feedback to the QB2 to indicate when the desired pressure has been achieved in the manifold. Air Supply PSR Series Volume Booster 4 5 6 3 2 QB2 1 McCordsville, IN Manifold DS Series Pressure Transducer Made in U.S.A. 2 Accumulator Tanks

FUNCTIONAL DSCRIPTION BB2/PSR and QB2/PSR pressure control valves combine Proportion- Air s closed loop electronic pressure control valve and ProAir series volume booster into one complete package. Output pressure is proportional to an electrical signal input. Three components make up the valve package: BB2 or QB2 electro-pneumatic valve, an external transducer, and ProAir electropneumatic valve regulator. BB2/QB2 Theory of Operation At the heart of this package is the BB2 or QB2 closed loop electronic pressure control valve. The BB2 or QB2 is a complete closed loop system consisting of valves, manifold, housing and electronic controls. Pressure is controlled by use of two internal solenoid valves. One valve functions as inlet control, the other as exhaust. Controlled pressure output from the volume booster is measured by the external pressure transducer. This transducer provides a feedback signal to the electronic circuit inside the BB2 or QB2. This second loop feedback is compared with the command signal input. This comparison is then summed with the internal pressure transducer signal. The circuit gain is designed with priority given to the external feedback signal. A difference between the two signals causes one of the solenoid valves to open, allowing flow in or out of the BB2 or QB2. Accurate pressure is maintained by controlling these solenoid valves. The control pressure functions as the pilot signal to the volume booster. latching version. This option allows the user to address which valves are to respond to signal changes, while others maintain present state. An additional latch bit is required with digital latching valves. Monitor Feedback The BB2 has an optional monitor signal available for output to a panel meter or for data acquisition needs, and a one-bit digital TTL signal. The analog output is a buffered signal from the external transducer representing output signal. The TTL output is a conditional on/off signal to use for diagnostic purposes. This signal is LOW when the pressure is within 1% of final setting. The outputs can function as logic information to other controls in the process. BB valves come with a red LD light to indicate power to the valve. When ordered with the monitor option, an additional green LD is also supplied. This light indicates the valve s pressure status. A bright green glow shows that desired pressure has been reached. QB series products come standard with a 0-10 Vdc monitor output or with 4-20 ma as an option. This analog output is a buffered signal from the external transducer representing output signal. xternal Transducer The second system component is a feedback signal from an external transducer. BB2 and QB2 can accept a variety of feedback signals such as 0-10 vdc, 4-20mA, or 2-3mV/V. Consult factory for special options. PSR Regulator The third component in this system is the ProAir series volume booster. This air piloted booster functions as a slave valve to the BB2 or QB2. It provides controlled pressure at a higher flow rate than is possible directly through the BB2 or QB2. An auxiliary air line is plumbed from the inlet of volume booster to supply pressure to the BB2 or QB2. Command Signal Command signal inputs come in one of three choices; analog-voltage, analog-current, or 8 bit digital (BB valve only). Analog driven units give virtually an infinite range of output pressures from zero to full scale. Digital driven units give 256 increments of pressure including zero. For multiplexing situations (many digital valves run off the same buss line) there is a digital BB2 BB2/PSR 3

4 PRFORMANC CHARACTRISTICS

GNRAL SPCIFICATIONS LCTRICAL SUPPLY VOLTAG...15-24 VDC SUPPLY CURRNT...250 ma max (Special options may have higher requirements.) COMMAND SIGNAL VOLTAG...0-10 VDC CURRNT BB STANDARD...4-20 ma sinking BB OPTION(S191)...4-20 ma differential QB STANDARD...4-20 ma differential DIGITAL (BB only) HIGH...2.5-24 VDC LOW...0-0.5 VDC COMMAND SIGNAL IMPDANC VOLTAG...4700Ω CURRNT BB...470Ω BB OPTION (S191)...100Ω QB...100Ω ANALOG SIGNAL VOLTAG...0-10 VDC @ 20 ma max CURRNT...4-20mA sinking (sourcing option available) TTL SIGNAL BB STANDARD HIGH/LOW...5/0 VDC BB DIGITAL LATCH SIGNAL HIGH...2.5-24VDC LOW...0-0.8 VDC BB DIGITAL LATCH TIM...200ns BB DIGITAL LATCH LOGIC...High = Latched Low = Active XTRNAL FDBACK STANDARD...0-10VDC OPTION...4-20mA** MCHANICAL* INLT PRSSUR RANGS...0-300 psig [0-20.7 bar] OUTPUT PRSSUR RANGS...0-200 psig [0-13.8 bar] FLOW RAT...Up to 700 SCFM - see graphs [330 Liters/sec] FILTRATION RCOMMNDD...20 micron included LINARITY/HYSTRSIS...<±0.2% F.S. BFSL RPATABILITY...<±0.02% F.S. ACCURACY...<±0.2% F.S. PHYSICAL OPRATING TMPRATUR...32-158 F (0-70 C] WIGHT BB2/PSR...3 to 4 lb [6.6 to 8.8 kg] QB2/PSR & DS Transducer...2.5 lb [1.1 kg] PROTCTION RATING BB...NMA 1 [IP50] QB...NMA 4, [IP65] *Specifications are for a 0-100 psig calibration. Other calibration ranges may have different specifications. Consult factory. **Consult factory for other sensor outputs. 5

FLOW FLOW DIMNSIONS GRN LD, CONDITION INDICATOR ( OPTION MODLS ONLY) BB2/PSR QB2/PSR* *w/optional DS Series Transducers 6.06 [154] RD LD, POWR INDICATOR 5.24 (133.10) 4.62 [117] LCTRICAL CONNCTIONS 3 PIN - BRAD HARRISON 5 PIN - BRAD HARRISON 18 PIN - DIGITAL BB 3.00 [76] HIRSCHMAN STYL CONNCTOR CALIBRATION ADJUSTMNTS Z S 1/8-27 NPTF RLIF PORT A MAIN BODY CALIBRATION ADJUSTMNTS (NORMALLY SALD) 1/8-27 NPTF RLIF PORT D D PORT C L C PRSSUR TRANSDUCR CALIBRATION ADJUSTMNTS (NORMALLY SALD) C FLOW Dimensions are for reference use only. B INCHS [mm] PRSSUR TRANSDUCR CALIBRATION ADJUSTMNTS (NORMALLY SALD) Model A B C D PSR-2, -3, -4 7.78 [198] 3.50 [89] 1.37 [35] 2.33 [59] 5.85 [148.59] PSR-6, -8 9.38 [238] 4.38 [111] 2.42 [62] 2.90 [74] 7.47 [189.74] PSR-A, -B 9.38 [238] 4.88 [124] 2.10 9[53] 3.23 [82] 7.48 [189.99] FLOW B MODL PSR-2 PSR-3 PSR-4 PSR-6 PSR-8 PSR-A PSR-B PORT SIZ 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT 1 NPT 1 1/4 NPT 1 1/2 NPT BRACKT FOR PSR-2, -3, -4 BRACKT FOR PSR-6, -8, -A, -B 1.13 [29] 1.25 [32] C L 1.00 [25] 13/32" (2 PLC'S).25 [6].57 [14] 1.53 [39] LC 5.00 [127] 3/8" (2 PLC'S) 6 3.50 [89]

SCOND LOOP INFORMATION All BB2 valves come with a matched pressure transducer for second loop feedback input. This transducer may be excluded by ordering option S59. Select this option if using a sensing device other than the pressure transducer provided. QB2 valves do not come with a matched pressure transducer for second loop feedback input. Standard QB2 valves accept 0-10vdc second loop signal. Special options are available for 4-20mA and unamplified feedback signals. The second loop feedback can be wired directly to the 6-pin Hirschmann connector or through an auxiliary receptacle (S305 option). To help facilitate wiring, an auxiliary adapter cord H23 is required when ordering BB2 with S59 option or QB2 with S305 option. Select H23 cord if using a sensing device other than DSY, DSTY, or DSVY pressure transducer. CONNCTION INFORMATION BB2/PSR 3 PIN DSIGNATORS PIN# WIR COLOR FUNCTION 1 GRN ( ) DC COMMON 2 BLACK (+) POWR 3 WHIT (+) COMMAND 5 PIN DSIGNATORS PIN# WIR COLOR FUNCTION 1 WHIT (+) COMMAND 2 RD ANALOG OUT 3 GRN ( ) DC COMMON 4 ORANG TTL OUT 5 BLACK (+) POWR ALL VIWS AR LOOKING AT RCPTACL ON BB2. SIGNAL OUTPUTS (OPTIONAL) Analog Output TTL Output Voltage = 0-10 Vdc sourcing Low = 0 Vdc Current = 4-20 ma sinking High = 5 Vdc DIGITAL PIN DSIGNATORS PIN# WIR COLOR FUNCTION A PINK BIT 1 (MSB) B GRAY BIT 2 C VIOLT BIT 3 D BROWN BIT 4 R BLU BIT 5 P YLLOW BIT 6 N WHIT BIT 7 L TAN BIT 8 (LSB) M ORANG TTL-OUT U RD ANALOG OUT K GRN ( ) DC COMMON G BLACK (+) POWR J RD/YLLOW LATCH PIN DSIGNATORS PIN# WIR COLOR* FUNCTION 1 GRN ( ) DC COMMON 2 BLU ( ) COMMAND (4-20 ma RTURN) 3 BROWN (+) 2ND LOOP IN QB2 ONLY 4 WHIT (+) COMMAND (0-10V or 4-20 ma) 5 RD (+) ANALOG 6 BLACK (+) DC POWR *FOR UNITS ORDRD WITH POWR CORD QB2/PSR RCPTACL ON HOUSING WIRING All QB products come with plug to mate to receptacle. Wiring to the plug requires field soldering wires during assembly. QB valves can be ordered with a pre-wired cord as an option. See ordering information for details. 7

ORDRING INFORMATION BB 2 M F 100 / PSR-2 S14 SRIS 2 = Two loop MODL CONTAINR M=Aluminum S=Stainless steel BB2 POWR CORDS 3 PIN CORDS (no monitor option) H6033 3 length [0.91 m] H6036 6 length [1.83 m] H6312 12 length [3.66 m] H6315 15 length [4.57 m] H6320 20 length [6.10 m] QB 2 T OPTION Blank=No Monitor F=Monitor SPCIFY SIGNAL WITH THIS OPTION COMMAND INPUT =Voltage 0-10 Vdc I=Current 4-20 ma D=Digital K=Digital Latching SIGNAL =Voltage 0-10 Vdc C=Current 4-20 ma Additional lengths available, consult factory. 5 PIN CORDS (monitor option and S191 option) H6053 3 length [0.91 m] H6056 6 length [1.83 m] H6512 12 length [3.66 m] H6515 15 length [4.57 m] H6520 20 length [6.10 m] F MAX. CALIBRATD PRSSUR Ranges Available 0 thru 200 psig xamples: 100=0-100 psig 005=0-5 psig 020=0-20 psig 159=0-159 psig VOLUM BOOSTR SPCIAL OPTIONS S14 = Third valve fail safe S59 = Build w/o external transducer S191 = 4-20 differential Contact factory for more available options. PSR-2 = 1/4 in. PSR-3 = 3/8 in. PSR-4 = 1/2 in. PSR-6 = 3/4 in. PSR-8 = 1 in. PSR-A =1-1/4 in. PSR-B =1-1/2 in. DIGITAL CORDS 13 PC-10 10 length [3.05 m] (additional lengths available) H618P lectrical connector only 100 / PSR-2 S305 SRIS MODL 2=Two Loop CONTAINR T=Impact Alum. SIGNAL F=Monitor 0-10 VDC STANDARD (4-20 ma optional) COMMAND INPUT = Voltage 0-10 Vdc I = Current 4-20 ma SIGNAL = Voltage 0-10 Vdc C = Current 4-20 ma MAX. CALIBRATD PRSSUR Ranges Available 0 thru 200 psig xamples: 100=0-100 psig 005=0-5 psig 020=0-20 psig 159=0-159 psig SPCIAL OPTIONS S305=Aux. receptacle S560=Fail to atmosphere S38=Calibrate 3-15 psi Contact factory for more available options. VOLUM BOOSTR ACCSSORIS QB2 POWR CORDS QBT-C-6 LNGTH (feet) One foot increments only PRSSUR TRANSDUCR DSY 100 xternal Pressure Transducer For Range Up to 200 psi (13.8 bar) Pressure Range Specify (psi) PSR-2 = 1/4 in. PSR-3 = 3/8 in. PSR-4 = 1/2 in. PSR-6 = 3/4 in. PSR-8 = 1 in. PSR-A =1-1/4 in. PSR-B =1-1/2 in. WARRANTY Proportion-Air products are warranted to the original purchaser only against defects in material or workmanship for (1) year from the date of manufacture. The extent of Proportion-Air s liability under this warranty is limited to repair or replacement of the defective unit at Proportion-Air s option. Proportion-Air shall have no liability under this warranty where improper installation or filtration occurred. All specifications are subject to change without notice. This warranty is given in lieu of, and buyer hereby expressly waives, warranties or liabilities, express implied or statutory, including without limitation any obligation of Proportion-Air with regard to consequential damages, warranties of merchantability, description, and fitness for a particular purpose. WARNING: Installation and use of this product should be under the supervision and control of properly qualified personnel in order to avoid the risk of death or injury. 8 PROPORTION-AIR, INC. BOX 218 McCORDSVILL, IN 46055 PHON: (317) 335-2602 FAX: (317) 335-3853 INTRNT www.proportionair.com -MAIL info@proportionair.com BR088 02/01