Agilent U2000 Series USB Power Sensors



Similar documents
Agilent U2000 Series USB Power Sensors

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent 87421A/87422A Power Supply

Agilent E5063A ENA Series Network Analyzer

The Next Generation in Automated Oscilloscope Test

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent U2000 Series USB Power Sensors

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent E6832A W-CDMA Calibration Application

Agilent Television Power Consumption Testing. Application Note

Agilent 4338B Milliohm Meter

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Keysight N6854A Geolocation System. Configuration Guide

802.11ac Power Measurement and Timing Analysis

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent FieldFox Remote Viewer

Think SAFETY When Selecting a Handheld Multimeter

Agilent 4339B/4349B High Resistance Meters

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

DDR Memory Overview, Development Cycle, and Challenges

Building Hybrid Test Systems, Part 1

Agilent 8753ET/8753ES Network Analyzers

The Real Total Cost of Ownership of Your Test Equipment

PXI and AXIe Modular Instrumentation

Agilent P940xA/C Solid State PIN Diode Switches

Agilent Test Solutions for Multiport and Balanced Devices

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

N6171A MATLAB Data Analysis Software for Agilent Instruments

PXI and AXIe Modular Instrumentation

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Agilent U2000 Series USB Power Sensors

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Application Note. Double click System tray icon after service started. Click start/continue button

Make Better RMS Measurements with Your DMM

E5092A Configurable Multiport Test Set

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

Evaluating Oscilloscope Bandwidths for Your Application

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Keysight E5063A ENA Series PCB Analyzer

Agilent EEsof EDA.

Agilent E5100A Network Analyzer

Report on Government Information Requests

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes

Get the benefits of Norgren s unique range of Online services

Keysight Technologies Compatibility of USB Power Sensors with Keysight Instruments. Application Note

WD Hard Drive Interface Guide

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Agilent EEsof EDA.

Keysight U8480 Series USB Thermocouple Power Sensors

High-Speed Inter Connect (HSIC) Solution

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

1.5 GHz Active Probe TAP1500 Datasheet

PANDUIT Physical Layer Infrastructure Management. EMC Smarts Integration Module

Microsoft Voucher Ordering Processes

MANDATORY PROVIDENT FUND SCHEMES AUTHORITY

Theatres/Channels All theatres. Indirect channel. Author/Owner

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Release Notes: PowerChute plus for Windows 95 and Windows 98

Updating the QIAcube operating software

How does a venture capitalist appraise investment opportunities?

TekSmartLab TBX3000A, TSL3000B Datasheet

Supported Payment Methods

Supported Payment Methods

Wireless Connectivity Testing

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Report on Government Information Requests

Agilent 8590C/E Series Spectrum Analyzers and Accessories Configuration Guide

E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

FedEx is the preferred and primary courier company for BP small package, parcel and express envelope (up to 150 lbs.) requirements worldwide.

Table 1: TSQM Version 1.4 Available Translations

Techniques for precise cable and antenna measurements in the field

NI USB-6008/6009 OEM USER GUIDE

Report on Government Information Requests

BT Premium Event Call and Web Rate Card

WHITE PAPER TEN CRUCIAL CONSIDERATIONS FOR EVALUATING AND SELECTING FIELD SERVICE MANAGEMENT SOFTWARE

Transcription:

Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10 MHz to 18 GHz) U2001H (10 MHz to 6 GHz) U2002H (50 MHz to 24 GHz) U2000B (10 MHz to 18 GHz) U2001B (10 MHz to 6 GHz)

Introduction U2000 Series Models This configuration guide describes the standard configurations, options, and compatible accessories for the U2000 Series USB power sensors. Contact your local Agilent representative for more information. Sensor model U2000A U2001A U2002A U2004A U2000H U2001H U2002H U2000B U2001B Description 10 MHz to 18 GHz, 60 dbm to +20 dbm USB Power Sensor, N-type (m) 10 MHz to 6 GHz, 60 dbm to +20 dbm USB Power Sensor, N-type (m) 50 MHz to 24 GHz, 60 dbm to +20 dbm USB Power Sensor, 3.5 mm (m) 9 khz to 6 GHz, 60 dbm to +20 dbm USB Power Sensor, N-type (m) 10 MHz to 18 GHz, 50 dbm to +30 dbm USB Power Sensor, N-type (m) 10 MHz to 6 GHz, 50 dbm to +30 dbm USB Power Sensor, N-type (m) 50 MHz to 24 GHz, 50 dbm to +30 dbm USB Power Sensor, 3.5 mm (m) 10 MHz to 18 GHz, 30 dbm to +44 dbm USB Power Sensor, N-type (m) 10 MHz to 6 GHz, 30 dbm to +44 dbm USB Power Sensor, N-type (m) Options and Accessories Special Options Option Number U2001A-H03 U2001A-H16 U2001A-H25 U2002A-H26 Description U2001A sensor with extended frequency range, 3 MHz to 6 GHz With 1K ohms input trigger impedance. Higher impedance is typically required when several instruments input trigger ports are connected in parallel for triggering purpose. Standard option has 50 ohms input trigger impedance. U2001A sensor with extended power range, -60 dbm to +25 dbm U2002A sensor with extended frequency range, 10 MHz to 26.5 GHz Calibration Documentation Option U200xx-A6J: ANSI Z540 compliance calibration test data including measurement uncertainties Option U200xx-1A7: ISO17025 compliance calibration test data including measurement uncertainties Documentation A hard copy and CD version of the English language operating and service guide, programming guide, and the N1918A Power Analysis Assembly are shipped together with the USB power sensor as standard items. 2

Additional documentation Selection can be made for the localized languages of the operating and service guide. The table below lists out the available languages. U200xx-0B1 U200xx-ABD U200xx-ABE U200xx-ABF U200xx-ABJ U200xx-ABZ U200xx-AB2 English language operating and service guide German language operating and service guide Spanish language operating and service guide French language operating and service guide Japanese language operating and service guide Italian language operating and service guide Simplified Chinese operating and service guide Standard Cables A 1.5 m ( Option 301) USB 2.0 Compliance cable with USB Mini-B connector and locking mechanism to the sensor is provided as standard (The 1.5 m cable can be replaced with 3.0 m (Option 302) or 5.0 m (Option 303) USB 2.0 Compliance cable length, charges applied) A 1.5 m trigger cable BNC male to SMB female 50 W Additional cables U2031A: USB 2.0 compliance cable with USB Mini-B connector and locking mechanism, length 1.5 m (5 ft) U2031B: USB 2.0 compliance cable with USB Mini-B connector and locking mechanism, length 3 m (10 ft) U2031C: USB 2.0 compliance cable with USB Mini-B connector and locking mechanism, length 5 m (16.7 ft) U2032A: Trigger cable BNC male to SMB female 50 W, length 1.5 m (5ft) Accessories U2000A-201 Transit Case U2000A-202 Soft Carrying Case U2000A-203 Holster U2000A-204 Soft Carry Pouch To fit in 4 USB sensors, operating & service guide, programming guide, cables. To carry the sensor for field applications To mount on test systems To carry the sensor for field applications 3

Warranty and Calibration Each of the U2000 Series USB Power Sensors comes with a standard 12-month return to Agilent warranty. For an extension of the initial warranty and service plan to 3 or 5 years, order from the listed options below: R1280A Return-to-Agilent warranty and service plan R-51B-001-C R-51B-001-3C R-51B-001-5C 1 year Return-to-Agilent warranty 1 year Return-to-Agilent warranty extended to 3 years 1 year Return-to-Agilent warranty extended to 5 years R1282A Return-to-Agilent calibration plan 1 R-50C-011-3 R-50C-011-5 R-50C-021-3 R-50C-021-5 R-50C-016-3 R-50C-016-5 Agilent Calibration Upfront Support Plan 3 years coverage Agilent Calibration Upfront Support Plan 5 years coverage Z540 Calibration Upfront Support Plan 3 years coverage Z540 Calibration Upfront Support Plan 5 years coverage 17025 Calibration Upfront Support Plan 3 years coverage 17025 Calibration Upfront Support Plan 5 years coverage Standard Shipped Components USB power sensor unit Power sensor cable: 1.5 m, 3.0 m, or 5.0 m length ( Option 301, 302, 303) Trigger Cable BNC Male to SMB female 50 Ω, 1.5 m length Certificate of Calibration 2 N1918A Power Analysis Assembly Agilent IO Libraries Suites CD U2000 Series USB Power Sensors Operating and Service Guide U2000 Series USB Power Sensors Programming Guide U2000 Series USB Power Sensors Documentation CD Software Application The basic version of the Power Analysis Manager, Power Panel, is bundled with the purchase of Agilent U2000 Series USB power sensors. The Power Panel offers an easy-to-use standard graphical user interface (GUI) for the USB sensor. For more information on the Power Panel, please refer to N1918A Power Analysis Manager Data Sheet, literature number 5989-6612EN. 1 Only applicable for U2000A, U2001A, U2002A, and U2004A models. 2 The N1918A Option 100 license is required to operate the Power Analyzer; it needs to be purchased separately. 4

Complementary Equipment Agilent E5813A: NETWORKED 5-PORT USB-to-LAN hub, for multi-channels and long distance operation. User can connect an extended long LAN cable from the USB-to-LAN hub to a computer. Commercially available active USB hub, for multi-channel operations Instrument Compatibility Compatible Model PNA-X: N5242A PNA: E8361A/C, E8362B/C, E8363B/C, E8364B/C PNA-L: N5230A/C Handheld Spectrum Analyzer: N9340A/B MXG: N5181A/82A/83A, N5161A/62A RF Spectrum Analyzer: N9320B FieldFox RF Analyzer: N9912A Handheld Cable Antenna Tester: N9330 ENA: E5071C Compatible Firmware Revision A.07.50.13 and above A.01.05 and above A.01.31 and above B.02.20 and above A.02.05 and above A.01.05 and above 9.2 and above 5

For More Information Agilent provides free, detailed product and application notes: [1] Fundamental of RF and Microwave Power Measurements (Part 1), application notes 1449-1, literature number 5988-9213EN [2] Fundamental of RF and Microwave Power Measurements (Part 2), application notes 1449-2, literature number 5988-9214EN [3] Fundamental of RF and Microwave Power Measurements (Part 3), application notes 1449-3, literature number 5988-9215EN [4] Fundamental of RF and Microwave Power Measurements (Part 4), application notes 1449-4, literature number 5988-9216EN [5] Steps for Making Better Power Measurements, application note 64-4D, literature number 5965-8167EN [6] Choosing the Right Power Meter and Sensor, product note, literature number 5968-7150E Related Literature [1] U2000 Series USB power sensor datasheet, literature number 5989-6278EN [2] U2000 Series USB power sensor technical overview, literature number 5989-6279EN [3] U2000 Series USB power sensor configuration guide, literature number 5989-6281EN [4] U2000 Series USB power sensor demo guide, literature number 5989-6280EN 6

www.agilent.com www.agilent.com/find/powermeters www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment through-out its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Latin America 305 269 7500 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2010 Printed in USA, July 5, 2010 5989-6281EN