The In-Flow Intraurethral Valve-Pump



Similar documents
Self Catheterization Guide

CATHETERISATION. East Lancashire Hospitals NHS Trust Eileen Whitehead 2010

CARE PROCESS STEP EXPECTATIONS RATIONALE

Postoperative. Voiding Dysfunction

Achieving Independence

Learning Resource Guide. Understanding Incontinence Prism Innovations, Inc. All Rights Reserved

Achieving Independence. A Guide to Self-Catheterization with the Bard Touchless Plus Intermittent Catheter System

symptoms of Incontinence

What s new? INVESTIGATIVE PROTOCOL FOR URINARY INCONTINENCE & CATHETERS. The Revised Guidance Includes: Interpretive Guidelines

URINARY CATHETER CARE

NICE Pathways bring together all NICE guidance, quality standards and other NICE information on a specific topic.

Infection Prevention & Control Team. Your urinary catheter & how to care for it / Patient Information Leaflet

PROCEDURE FOR CLEAN INTERMITTENT CATHETERIZATION MALE

Managing your bladder with a suprapubic catheter at home

Bladder and Bowel Control

PATIENT URINARY CATHETER PASSPORT

Bladder Management Options Following Spinal Cord Injury

Intermittent Self Catheterisation for Women

Overactive Bladder (OAB)

SECTION 12.1 URINARY CATHETERS

PATIENT CARE MANUAL PROCEDURE

Fact Sheet. Caring for and Changing your Supra-Pubic Catheter (SPC) Queensland Spinal Cord Injuries Service

510(k) SUMMARY. OPTION-vyM Urinary Catheter

MEDICAL POLICY No R1 INCONTINENCE SUPPLIES FOR MEDICAID MEMBERS

MEDICAL POLICY No R1 INCONTINENCE SUPPLIES FOR MEDICAID MEMBERS

online version Understanding Indwelling Urinary Catheters and Drainage Systems Useful information When to call for help

Normal bladder function requires a coordinated effort between the brain, spinal cord, and the bladder.

Adult Urodynamics: American Urological Association (AUA)/Society of Urodynamics, Female Pelvic Medicine & Urogenital Reconstruction (SUFU) Guideline

PREVENTION OF CATHETER ASSOCIATED URINARY TRACT INFECTIONS. (CAUTIs)

Instruction Guide to Sterile Self-Catheterization for Women Using the Cure Catheter Closed System

Kaiser Oakland Urology

A PRINTED copy of this guideline may not be the most recent version. The OFFICIAL version is located on IHNET at the Policies & Procedures Home Page

Case Based Urology Learning Program

Catheter Care. What you need to know. Jacinta Stewart Continence Nurse

Catheter Associated Urinary Tract Infection (CAUTI) Prevention. System CAUTI Prevention Team

2. Does the patient have one of the following appropriate indications for placing indwelling urinary catheters?

Topic review: Clinical presentation and diagnosis of urinary incontinence in the elderly. Prapa Pattrapornpisut 7 June 2012

SAMPLE Policy and Procedure Insertion, Removal and Care of an Indwelling Foley Catheter

URINARY CATHETER INSERTION - STRAIGHT OR INDWELLING CATHETER

Bladder Health Promotion

URINARY INCONTINENCE CASE PRESENTATION #1. Urinary Incontinence - History 2014/10/07. Structure of the Female Lower Urinary Tract

Hot Topics In Infection Control!

Spinal Cord and Bladder Management Male: Intermittent Catheter

Indwelling urinary catheter. Information for patients and carers. RDaSH. Doncaster Community Integrated Services

Discussions about having a Supra pubic catheter

INTERDISCIPLINARY CLINICAL MANUAL Practice Guideline

Urinary Incontinence

A Guide to Help You Manage Your Catheter and Drainage Bags

Having a supra pubic urinary catheter

URINARY INCONTINENCE IN WOMEN

Male Urinary Catheterisation & Catheter Care

ATI Skills Modules Checklist for Urinary Catheter Care

Female Urinary Disorders and Pelvic Organ Prolapse

VaPro Touch Free Hydrophilic Intermittent Catheter

Intermittent Clean Catheterization for Women

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

Bladder Catheterization

THE MANAGEMENT OF URINARY INCONTINENCE WITHIN A STROKE UNIT POPULATION REENA DHAMI STROKE CNS EPSOM & ST.HELIER UNIVERSITY HOSPITALS

Urinary Incontinence in Women. Susan Hingle, M.D. Department of Medicine

Urinary Incontinence Dr. Leffler

VUMC Guidelines for Management of Indwelling Urinary Catheters. UC Access/ Maintenance

Patient Information:

Urinary Incontinence (Involuntary Loss of Urine) A Patient Guide

FEMALE INCONTINENCE REVIEW

Self-Catheterization after Bladder Surgery For Women

Looking after your bladder

III-701 Urinary Catheterization/Bladder Irrigation Original Date: 3/1/1977 Last Review Date: 10/28/2004

Bladder Health Promotion

Guidelines on Neurogenic Lower Urinary Tract Dysfunction

Going home with a urinary cathether

Foley Catheter Placement

Prevention of catheter associated urinary tract infections

PROCEDURE FOR URINARY CATHETERISATION

Urodynamic Studies. Urinary flow rate Cystometry (CMG) Urethral pressure profile (UPP)

150640_Brochure_B 4/12/07 2:58 PM Page 2. Patient Information. Freedom From an Enlarged Prostate

Transobturator tape sling Female sling system

Catheter-Associated Urinary Tract Infection (CAUTI) Prevention. Basics of Infection Prevention 2 Day Mini-Course 2013

URINARY INCONTINENCE

Urinary Tract Infections in Children

Male Urethral Catheterisation Education Package

Catheter-Associated Urinary Tract Infections Lauren Tew, Bard Ltd, UK A Webber Training Teleclass Catheter-Associated Urinary Tract Infection

PROCEDURE FOR CATHETER AFTERCARE

Essential steps to safe, clean care

Appropriate Urinary Catheter Use and Management

Looking after your urinary catheter at home

Bard. Guide for Patients. Comprehensive Care Managing Urinary Catheters and Drainage Systems. Useful information. Useful organisations

High Impact Intervention Urinary catheter care bundle

Urinary Incontinence FAQ Sheet

NHS Professionals. CG8 Guidelines for Continence and Catheter Care. Introduction

Avoiding Urinary Tract Infections in Patients practising Intermittent Catheterization

COMPLICATIONS OF FISTULA REPAIR SURGERY. Sherif Mourad

Location: Clinical Practice Manual

Refer to Coaptite Injectable Implant Instructions for Use provided with product for complete instructions for use.

Infection Control in the Use of Urethral Catheters: Knowledge and Practices of Nurses in a Private Hospital in Iloilo City

Nursing college, Second stage Microbiology Dr.Nada Khazal K. Hendi L14: Hospital acquired infection, nosocomial infection

Transcription:

The In-Flow Intraurethral Valve-Pump 29 March 2011 1

Advanced Technology for More Natural Voiding How do you get urine out of the bladder without causing infection? 100,000,000 urinary catheters are used globally every year, but they cause infections that kill tens of thousands and cost billions in medical care The In-Flow has been shown to have the lowest infection rate by far of any indwelling device for bladder drainage Active stent-like device replaces passive urinary catheters The In-Flow is also the most discrete and dignified solution for female bladder drainage Significantly improves quality of life 2

In-Flow Indication Replaceable urinary prosthesis intended to normalize toileting in women with atonic bladder or other voiding dysfunction resulting in an inability to fully empty the bladder A prosthetic device compensates for a specific physiologic deficiency The In-Flow compensates for the lack of bladder pressure in women with atonic bladder by providing forceful, virtually complete evacuation of urine on demand 3

Design and Materials Female-only Intraurethral Device Miniature valve-pump mechanism entirely housed in medical-grade silicone Supplied sterile, 29 day use Sized to length of patient s urethra (9 lengths) Flexible bladder fixation - simple and safe removal Magnetic remote-control ( Activator ) Spins internal magnet at 10,000 RPM, creating turbine pump Engages valve automatically when pump is not in use to maintain continence 4

Principles of Operation - Insertion Device is inserted using disposable introducer Flexible silicone fins hold it in place 5

Principles of Operation - Voiding Patient normally sits on a toilet Patient / caregiver presses the button Pump is activated and provides normal flow, quickly draining the bladder Releasing the button automatically engages the valve, stopping further flow 6

Target Patient Population Women with atonic bladder Lack bladder pressure - cannot spontaneously urinate Typically due to neurologic injury or disease (MS, stroke, SCI, diabetic neuropathies, etc.) Incurable condition with very limited treatment options Typically requires life-long use of urinary catheters The inability to void is one of life s most discouraging circumstances 7

Present Clinical Alternatives Urinary catheters may be the simplest and most commonly used medical devices, but they cause serious problems, notably: Low quality of life, and High rates of urinary tract infection (UTI) Problems amplified with atonic bladder - must use catheters for life New treatments exist for neurogenic OAB (overactive bladder), but not for atonic (underactive) bladder Two types of urinary catheters are most often used for women Intermittent catheters Indwelling (Foley) catheters 8

Clean Intermittent Catheterization (CIC) Current standard of care for long term bladder drainage Known to have substantially lower clinical UTI rate than indwelling (Foley) catheters Patient inserts a tube into her urethra 4-8 times per day for voiding However, many cannot reliably self-catheterize Lack necessary manual, visual or cognitive ability Particularly true of many women with atonic bladder due to serious nature of their primary medical condition Others simply will not perform this procedure Find repeated touching of genital area distressing Elderly women in particular often opt for Foleys despite well understood problems 9

Indwelling (Foley) Catheters Held in place via a water-filled balloon in the bladder Typically connected to a urine collection bag Medically demanding 5% risk of UTI per day (virtually 100% in 30 days) 50% encrustation, routine skin/tissue problems 10

Psychologically challenging Literally tied to a bag of your own urine Many patients consider this an end-stage development Correctly or not 11

Comparison to Urinary Catheters Based on clinical evidence to date, In-Flow compares favorably to both CIC and indwelling (Foley) catheters Compared to CIC, improves quality of life with similar safety and effectiveness In-Flow Low UTI rate Foleys Compared to Foley catheters, Easy to use improves quality of life with Convenient vastly superior safety CIC Hygienic Positive body image Allows use of toilet 12

In-Flow Evidence Six clinical studies (total n=510), including two long-term studies Extensive laboratory testing, including independently conducted encrustation study 12 years of patient use in Germany, Canada and Australia 13

IDE Study Design 18-site study (n=273) to compare safety, effectiveness and patient satisfaction of the In-Flow device versus clean intermittent catheterization (CIC) CIC is current standard of care for long-term bladder drainage Study limited to women with atonic bladder who were already using CIC Single-arm crossover design in which each subject acted as her own control Relevant clinical endpoints were selected Primary endpoint of PVR objectively indicates how effectively each device drains bladder Required excluding subjects using indwelling (Foley) catheters Secondary endpoint of QoL indicates effects of using these highly personal devices Wagner I-QOL most appropriate instrument available at time of study All aspects of study independently monitored 14

IDE Study Results All clinical endpoints were met 1. Primary Endpoint: Post-void residuals (PVRs) - CIC and the In-Flow were equivalent in their ability to fully empty the bladder (98% same) 2. Secondary Endpoint: Quality of life per Wagner I-QOL - Scores were 50% higher for In-Flow than for CIC (clinically & statistically significant superiority) 3. Comparative safety: UTI rates were equivalent, although In-Flow is indwelling and CIC is intermittent (breakthrough technology) 15

Clinical Role The In-Flow distinguished itself in two areas of its IDE study Quality of life scores were significantly higher than for CIC 50% better in the IDE and 80% better in another study In-Flow s UTI rate was equivalent to CIC unprecedented for an indwelling device Showing a UTI rate comparable to that for intermittent catheters is a unique and powerful effect Even so, the In-Flow is probably better positioned on basis of its ability to improve quality of life Can be quickly driven by patient demand vs. requiring large-scale studies Exception is that present data re UTI rate are probably adequate to drive adoption by indwelling (Foley) users 16

Independent Studies Five independent (non-company sponsored) clinical studies (total n=239) report similar findings to the IDE study Device performed as expected in all instances No serious or lasting adverse events were reported in any study Specific findings from the two long-term studies include: In a one-year study of 20 acontractile (atonic) bladder patients, Lynch et al reported 80% improvement in quality of life (QoL) and no negative tissue changes: This study shows that the Inflow device provides an effective method of bladder drainage, with few side-effects and significant improvement in QoL. In a pre-ide study of 40 patients with voiding dysfunction in which 21 patients were followed for more than a year with a mean follow-up time of 24.6 months, Madjar et al concluded that, although dropout was a problem (due largely to discomfort): Women who continue treatment for a prolonged time are satisfied with the device use. In fact, All patients were satisfied with the device and preferred it to previous treatment modalities used. 17

Laboratory Testing A series of pre-clinical bench studies were conducted to characterize the performance of the In-Flow system. The results of these tests demonstrated that the In-Flow device and Activator meet their performance specifications and, where applicable, conform with the requirements of relevant voluntary standards. The tests performed were as follows: Device Pull-out Force Testing (as per "Inflated Balloon Response to Traction" test in ASTM F623-89 Standard Performance Specification for Foley Catheters) Device Flow Rate Testing (as per "Flow Rate through Drainage Lumen" test in ASTM F623-89) High Pressure Test (seal maintained under 200 cm H20 bladder pressure) Device Pump and Valve Endurance Test (1,140 voiding cycles = 6 months use) Activator Endurance Testing (11,552 operation cycles=5 years) Activator Drop Testing (50 cm onto hard surface) Activator Battery Endurance Testing (2 months) Catheter's DC Magnetic Field Levels (Alpen Committee standards) Activator DC Magnetic Field Testing (Alpen Committee standards) Activator AC Magnetic Field Testing (IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 khz to 300 GHz) 18

Biocompatibility Testing A series of biocompatibility tests was conducted to characterize the biocompatibility of the materials used in the In-Flow device, inserter, Activator, and Sizing Device. These tests demonstrated that these components do not cause cytotoxic response, irritation, or sensitization. The device was also shown to be nonmutagenic. The tests were conducted by NAmSA on final, gamma radiation-sterilized devices, in accordance with GLP regulations. The tests conducted are listed below, according to component. In-Flow Device: Cytotoxicity (MEM elution as per ISO 10993-5) Vaginal irritation in rabbits Sensitization (guinea pig maximization) Genotoxicity (Ames mutagenicity test) Implantation testing (as per ISO 10993-6) Urinary bladder irritation study in rabbit (surgical implantation) Urinary bladder irritation study in rabbit (saline extract) In-Flow Device Magnet Assembly: Cytotoxicity testing of nickel and parylene coated magnets (MEM elution as per ISO 10993-5) Acute systemic toxicity of nickel and parylene coated magnets (U.S.P. methodology) Acute intracutaneous reactivity of nickel and parylene coated magnets (ISO Tests for Irritation and Sensitization) Corrosion potential of nickel and parylene coated magnets Individual In-Flow Device Materials: Silicone elastomer Elastosil (Certificate of Compliance with USP Class VI Biological Tests) Polycarbonate Lexan HF 1140 (USP Class VI) Parylene Coating (USP Class VI) Adhesive Loctite 3311 (USP Class VI) In-Flow Inserter (Nylon 6,6; transient contact with labia): Cytotoxicity (MEM elution as per ISO 10993-5) Acute intracutaneous reactivity (ISO Tests for Irritation and Sensitization) Sensitization (guinea pig maximization test) In-Flow Activator (Nylon 6,6: brief contact with hands and abdomen): Cytotoxicity (MEM elution as per ISO 10993-5) 19

Encrustation Study Stickler et al1 in vitro study showed In-Flow encrustation resistance to be at least 8.4x superior to an all-silicone Foley: Under conditions that simulated a heavy infection of P. mirabilis, where a conventional Foley catheter blocked with crystalline biofilm after 25.7 hours, the In-Flow device drained the bladder for at least 9 days (and its) central lumen appeared to be essentially clear. 1Microbiology Research Group at Cardiff UK (internationally recognized experts on CAUTI) 20

Transformational Technology It can simply, yet absolutely transform the quality of individuals lives. - Brother of IDE patient the device has been an unqualified success. It is difficult to put into words the effect that (In-Flow) has had on (my daughter s) life. - Father of IDE patient The In-Flow allows use of a toilet Psychologically significant as that is the normal way to void Promotes hygiene, personal dignity Eliminates need to self-cath 4-8 times daily Eliminates tubes, drainage bags 21

Thank You 22

0459 The In-Flow device conforms to Council Directive 93/42/EEC and bears the CE mark. Authorized European Representative: www.mtm-med.com CAUTION: Not cleared by the FDA for sale in the USA. Investigational device. Limited by US law to investigational use. U.S. Patent Nos. 5,762,599 and 6,417,750 and related patents worldwide. Additional patents pending. In-Flow is a trademark of SRS Medical Systems, Inc. 2007-2011 SRS Medical Systems, Inc. All rights reserved. 23

New: Sizing Device In order to improve the accuracy of In-Flow sizing, both the Sizing Device and measurement protocol have been revised A graduated version of the longest In-Flow device (7cm) is now used to measure urethral length Bladder neck contact is now consistent, minimizing sizing errors The measurement protocol now includes several postures and not just the lithotomy position in order to account for possible prolapse 24