Effects of Atmospheric Pressure on Gas Measurement



Similar documents
Testing, maintenance and operation of Electronic Flow Computers for the Gas Industry

Barometric Effects on Transducer Data and Groundwater Levels in Monitoring Wells D.A. Wardwell, October 2007

TEACHING TOMORROW S INDUSTRY LEADERS TODAY. Manufacturing Small Parts on Machining Centers

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

THE STRAIN GAGE PRESSURE TRANSDUCER

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

Understanding Pressure and Pressure Measurement

Experiment # 3: Pipe Flow

Temperature Measure of KE At the same temperature, heavier molecules have less speed Absolute Zero -273 o C 0 K

Gas Custody Transfer Calibration

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Custody Transfer Measurement. with the V-Cone Flowmeter

Float & Tape Tank Gauging Solutions for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory-Grade Level Measurement

Name Date Class. As you read about the properties of air, fill in the detail boxes that explain the main idea in the graphic organizer below.

CHAPTER 3: FORCES AND PRESSURE

2005 WJTA American Waterjet Conference August 21-23, 2005 Houston, Texas Paper SAFE WATERJET CLEANING OF STEEL PROCESS LINES

How to measure absolute pressure using piezoresistive sensing elements

FLUID FLOW Introduction General Description

p atmospheric Statics : Pressure Hydrostatic Pressure: linear change in pressure with depth Measure depth, h, from free surface Pressure Head p gh

Morrison Bros. Co. General Product Specifications

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Experiment (13): Flow channel

User s Manual Laminar Flow Elements

barometer 1 of 5 For the complete encyclopedic entry with media resources, visit:

Pressure in Fluids. Introduction

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Pressure calibration equipment

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

WEATHER STATION FOR SOLAR FARM MONITORING

OUTCOME 1 STATIC FLUID SYSTEMS TUTORIAL 1 - HYDROSTATICS

Understanding the altimeter

Calibrating Differential Pressure Sensors

Ambient Pressure = and Pressure, collectively

PRODUCT PROFILE FEATURES

Many Products...One Source

Improving SCADA Operations Using Wireless Instrumentation

Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

Evaluation copy. Figure 1

COMPRESSED AIR ULTRASONIC LEAK DETECTION GUIDE

SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions

BaseCal 3. BaseCal, the web-based performance calculation tool for Diaphragm Seals

nvision Reference Recorder

Experiment 3 Pipe Friction

Jump Start: Storage Tank Protection in Aspen HYSYS and Aspen Plus

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

Thermal Dispersion Mass Flow

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

DISSOLVED OXYGEN PROBE

Toroidal Conductivity Sensor

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

Weight Measurement Technology

T U R B I N E G A S M E T E R

Tank Level Gauging, Safety Equipment & Inventory Management for Alcohol and Beverage Applications

Physics 1114: Unit 6 Homework: Answers

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

qê~çé=~êíáåäé= Fundamentals of hydrostatic level measurement

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

Fundamental Principles of Rotary Displacement Meters

Theory, Application, and Sizing of Air Valves

The Unique Accelabar Flow Meter

A Practical Guide to Free Energy Devices

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

oil liquid water water liquid Answer, Key Homework 2 David McIntyre 1

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

THE HUMIDITY/MOISTURE HANDBOOK

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Global GSM & Satellite Remote Monitoring

A. Kinetic Molecular Theory (KMT) = the idea that particles of matter are always in motion and that this motion has consequences.

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

= water horsepower WHP brake horsepower QH WHP = (222) ( 33,000 ft-lbs/min-hp)( gal/ft ) 1 HP=0.746 kw

Kinetic Theory of Gases. 6.1 Properties of Gases 6.2 Gas Pressure. Properties That Describe a Gas. Gas Pressure. Learning Check.

Chapter 4 Atmospheric Pressure and Wind

Subminiature Load Cell Model 8417

ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019)

Step Rate Testing: Determining Fracture Pressure for Injection Wells 2016 UNDERGROUND INJECTION CONTROL CONFERENCE DENVER, CO LEWIS WANDKE, PE

WIKA INSTRUMENT CORPORATION

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

Environment-Laboratory Ambient Conditions

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

In-Line Air Separators

Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper

RGC-IR Remote Gas Calibrator for IR400

How To Use A Corona Mdi 110

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Transcription:

Effects of Atmospheric Pressure on Gas Measurement Class # 1390.1 March 2012 / White paper by Denis Rutherford Regional Sales Manager Central US Schneider Electric Telemetry & Remote SCADA Solutions 6650 W Sam Houston PKY N Suite 420 Houston, TX 77041 USA Make the most of your energy

Summary Executive Summary... p 2 Introduction... p 3 Pressure Defined... p 4 Electronic Sensors... p 6 Flow Computer Configuration... p 6 Flow Error Example... p 7 Conclusion... p 9 Glossary of common pressure terms... p 10

Executive summary This white paper discusses the differences between gauge and absolute pressure sensors, methods of determining the atmospheric pressure at a location, and effects of atmospheric pressure on measurement accuracy. White paper on Effects of Atmospheric Pressure on Gas Measurement 02

Introduction One of the often overlooked or misunderstood parameters in upstream gas measurement is the atmospheric pressure input. To correctly configure any Electronic Flow Measurement (EFM) device to calculate a corrected volume, the static pressure at the meter run must be an input to the calculations as an absolute pressure value. Since the absolute pressure is defined as the sum of the gauge and atmospheric pressures at the site, proper EFM setup requires that the atmospheric pressure be accurately determined for each metering location. This paper discusses the differences between gauge and absolute pressure sensors, methods of determining the atmospheric pressure at a location, and effects on measurement accuracy. White paper on Effects of Atmospheric Pressure on Gas Measurement 03

Pressure Defined We need to first understand the concept of atmospheric pressure. Simply put, atmospheric pressure is the force exerted by the weight of the atmosphere on a given point of the earth s surface. A standard atmosphere at mean sea level is generally accepted to be 101.325 kpa or 14.696 PSI or 1 ATM. This brings up two points to consider: 1. The weight of the atmosphere at any given moment, at any given point on the earth s surface changes with the density of the air, which is dependent on the temperature and moisture content, or put simply, it changes with the weather. In reviewing some Environment Canada data for atmospheric pressure changes over the course of a year for any given location, the maximum change due to weather is limited to approximately +/- 2 kpa or +/-.3 psi. So we can see that the impact of weather on determining the atmospheric pressure at a location is, for most production applications, quite small. 2. The weight of the atmosphere at any given point is a function of the elevation above sea level. For example there is more atmosphere above a lower elevation on earth, such as sea level, and hence a higher atmospheric pressure, than at any point of higher elevation. As you climb a mountain, and your elevation above sea level increases, the amount of atmosphere above you decreases; subsequently the atmospheric pressure on you decreases. The following formula is often used to approximate the atmospheric pressure at an elevation: Atmospheric Pressure (kpa) = 101.56 (0.0113 * Elevation (m)) From the above formula you can see that as a rule of thumb, the atmospheric pressure decreases by approximately 1 kpa for each 100 meters or 328.8 feet of elevation rise above sea level. To illustrate the above point, the Calgary International Airport website states their elevation as 1139 m above sea level. Using the above formula the approximate atmospheric pressure at the airport will be 88.7 kpa, a considerable change from the mean sea level value of 101.325 kpa. So we now a have a good understanding of atmospheric pressure, the next step in defining absolute pressure is to understand gauge pressure. The term gauge pressure comes from the original gauges that are still routinely used to measure the pressure contained in a tank or vessel. A typical pressure gauge utilises an invention called the Bourdon tube to translate pressure in the tube to a linear movement of a needle on a gauge face. A Bourdon tube is typically a thin stainless steel tube with an oval cross-section that is bent into a semi circular or coiled shape. The tube is sealed at one end and open to the pressure source at the other. As the pressure increases inside the Bourdon tube, it causes the tube to expand and straighten, thereby causing its shape to change. A mechanism is then used to translate this increased radius to a linear deflection of the dial. White paper on Effects of Atmospheric Pressure on Gas Measurement 04

Because the outside of a Bourdon tube is subject to atmospheric pressure at the site, the atmospheric pressure becomes the reference and the measured value shows only how much higher the process pressure is in comparison to the atmosphere. Therefore, if we are located at sea level where our atmospheric pressure is highest, our gauge reading will be lower than if we are at 1000 meters above sea level where there is less atmospheric pressure, and subsequently less counter force exerted on the Bourdon tube. Hence a Bourdon tube gauge will need to be calibrated to read correctly at the installed atmospheric pressure. The term absolute pressure is defined as: Absolute Pressure = Gauge Pressure + Atmospheric Pressure Where absolute zero pressure is defined as the pressure inside a perfect vacuum. White paper on Effects of Atmospheric Pressure on Gas Measurement 05

Electronic Sensors With increased use of electronic sensors (Multivariable Transmitters MVT s) coupled with Electronic Flow Measurement (EFM) devices to calculate corrected flow at the well head or sales points, it is important that users understand the type of pressure transmitter technology being used so that the pressure input is applied to the flow computer correctly. There are basically two types of electronic pressure sensors available on the market today: 1. Gauge pressure sensor 2. Absolute pressure sensor Gauge pressure sensors are constructed in two configurations: vented gauge, and sealed gauge. A vented gauge sensor has its reference connected to the local atmospheric pressure and is designed to compensate for changes in atmospheric pressure, and always report the true gauge pressure in the line or vessel. A sealed gauge sensor has the reference side of the pressure sensor sealed at atmospheric pressure. Typically a sealed gauge sensor will show a zero offset when initially installed and opened to atmosphere, due to the difference in the atmospheric pressure at the local site from the atmospheric reference pressure in the cell. This zero offset is typically calibrated out at the time of installation. The third sensor type is a true absolute pressure transmitter. The absolute pressure sensor is constructed with its reference to a near perfect vacuum or absolute zero pressure. This type of sensor when properly calibrated and opened to atmosphere will read the actual atmospheric pressure at the location based on local elevation and weather conditions. In lab conditions an absolute pressure sensor zero calibration is often done by applying a vacuum to the sensor. Since applying a vacuum to a sensor is not practical for field calibrations, and since many field service companies are not equipped with accurate electronic barometers, it is common practice to set the vented absolute pressure to be equal to the atmospheric pressure obtained from the site and the estimation formula on page 1. Flow Computer Configuration When configuring the static pressure input for an EFM device there is typically a selection box to select whether the pressure will be input as a gauge or absolute pressure value. A second input box is typically provided to enter the Atmospheric Pressure reference for the location. If using a gauge sensor the atmospheric pressure must be either measured or calculated using the estimation formula and entered as part of the configuration. If using an absolute pressure sensor there is no further need to enter a fixed atmospheric pressure, as a properly calibrated sensor will automatically provide this reference. White paper on Effects of Atmospheric Pressure on Gas Measurement 06

SCADA Systems Overview Flow Error Example What are the effects of an incorrectly set atmospheric pressure reference on measurement? This largely depends on the actual static pressure that is being measured by the well. As the static pressure decreases, the effect of any error in the atmospheric pressure reference has an increased effect on the calculated flow rate. One of the most common mistakes in well head EFM is to enter the atmospheric pressure reference as 101.325 kpa (the standard for sea level). Let s assume that the meter is installed at the Calgary Airport where the reference atmospheric pressure should be 88.7 kpa. Utilising an industry standard calculation-check program with sample inputs, a comparison of the calculated flow rate with an incorrect atmospheric pressure input of 101.325 kpa versus the correct input of 88.7 kpa shows a 5% error for 50 kpa gauge readings. The effects at higher pressures are shown in the table and graph below: Flow Calculation Inputs Orifice Diameter: Pipe Diameter: 50 mm 100 mm Temperature: 20 C Differential Pressure: 25 kpa Flow Rate (E 3 M 3 ) Flow Rate Flow Rate P gauge kpa Patm = 101.325 Patm = 88.7 kpa Difference % Error 50 31.40 29.91 1.50 5.01% 100 36.75 35.48 1.28 3.60% 200 45.64 44.61 1.03 2.30% 500 65.55 64.83 0.72 1.11% 1000 89.71 89.18 0.53 0.60% 5000 202.57 202.29 0.28 0.14% 10000 299.19 298.99 0.20 0.07% Table 1: Flow Error due to incorrectly entered Atmospheric Pressure reference White paper on Effects of Atmospheric Pressure on Gas Measurement 07

Figure 1 From the above data you can see that a significant overstatement of the corrected volume is shown for pressures below 2000 kpa. As expected, the significance of the error diminishes as the static pressures climb. In practice, the effect of using an incorrect atmospheric pressure reference will have more effect at the well head especially in low pressure fields, than at a higher pressure sales or distribution point. White paper on Effects of Atmospheric Pressure on Gas Measurement 08

Conclusion As the reservoir pressures decline in our traditional gas fields and with growing interest in the production of lower pressure coal bed methane wells, the error incurred by incorrect specification of the atmospheric pressure reference can begin to have a large effect on the overall accuracy of the measurement. Utilising proper calibration equipment, or as a minimum, applying the estimation formulas to calculate the atmospheric pressure based on the elevation of the site, will help to minimise measurement errors. White paper on Effects of Atmospheric Pressure on Gas Measurement 09

Glossary of common pressure terms: Absolute Pressure The sum of gauge pressure and atmospheric pressure. Atmospheric Pressure Pressure exerted on the earth by the weight of the atmosphere above it. Barometric Pressure or Station Pressure Local atmospheric pressure as measured using a barometer. This pressure is often reported by weather stations and is typically referenced to zero elevation (sea level) with the effects of elevation removed. Contract Pressure This is the reference contract pressure condition that the gas volume being measured is to be corrected to. This value is 101.325 kpa in Canada. Gauge Pressure Pressure exerted in the piping or vessel by the volume of gas being contained. Standard Atmosphere 101.325 kpa is generally considered a standard atmosphere at 0 m elevation above sea level. White paper on Effects of Atmospheric Pressure on Gas Measurement 10

Schneider Electric Telemetry & Remote SCADA Solutions 48 Steacie Drive, Kanata, Ontario K2K 2A9 Canada Direct Worldwide: 1 (613) 591-1943 Fax: 1 (613) 591-1022 Toll Free within North America: 1 (888) 267-2232 www.schneider-electric.com Document Number TBUL00001-27 This document has been printed on recycled paper March 2012 tk 2011 Schneider Electric. All rights reserved.