CONTINUOUS FRACTIONATION OF FRIED OIL BY SUPERCRITICAL CO 2 AND HEXANE L. Sesti Osséo*, T. Capolupo, E. Reverchon



Similar documents
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Analysis of Vegetable Oils by High Performance Liquid Chromatography

ß-CYCLODEXTRIN SYNONYMS

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Purification of reaction mixtures using flash chromatography.

Fractional Distillation and Gas Chromatography

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Decaffeination of Raw, Green Coffee Beans Using Supercritical CO 2

105 Adopted:

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

TABLE OF CONTENT

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

PhD Theses STUDY OF THE SOLVENT GRADIENT SIMULATED MOVING BED PREPARATIVE LIQUID CHROMATOGRAPHIC PROCESS. Written by Melinda Nagy

The Use of Hydrogen Carrier Gas for GC/MS

Faculty of Chemistry, Department of Physical Chemistry, University of Bucharest, 4-12 Regina Elisabeta, Bucharest, Romania

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

IB Chemistry. DP Chemistry Review

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

23 The Thermal Conductivity Detector

LIPE- Institut National des Sciences Appliquées Toulouse, France Contact:

The Empirical Formula of a Compound

PURIFICATION TECHNIQUES

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

How To Make A High Co 2 Gas Blend

BTU ANALYSIS USING A GAS CHROMATOGRAPH

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Experiment 5: Column Chromatography

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

[ Care and Use Manual ]

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

DEGASSED CATION CONDUCTIVITY MEASUREMENT

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

The Problem. Enhanced Oil Recovery Research. Research Details. For immediate release: June, 2015

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

CHM220 Addition lab. Experiment: Reactions of alkanes, alkenes, and cycloalkenes*

Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Anion chromatography using on-line recycled eluents

Gas Chromatography Liner Selection Guide

Lecture 35: Atmosphere in Furnaces

UNIVERSITA DEGLI STUDI DI ROMA LA SAPIENZA DIPARTIMENTO INGEGNERIA CHIMICA MATERIALI AMBIENTE

Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes

CHROMOCTANE O N LINE ANALYZER

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction

Research for leachables of nuclear grade cation exchange resin

HiPer Ion Exchange Chromatography Teaching Kit

AMD Analysis & Technology AG

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

8.9 - Flash Column Chromatography Guide

Vacuum and Compressor Systems for the Chemical Process Industry

EXTRACTION OF OIL FROM ALGAE BY SOLVENT EXTRACTION AND OIL EXPELLER METHOD

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Tamsulosin Hydrochloride Capsules

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

Fact Sheet Technology. Bergius-Pier Process (1)

Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

Optimization of Natural Gas Processing Plants Including Business Aspects

Compounds vs mixtures. Physics and Chemistry IES Jaume Salvador i Pedrol February 2009

Module 1: History of Fuels. Lecture 6: Fundamental definitions, properties and various measurements

Yu. F. Vasyuchkov*, M. Yu. Bykova* NEW TECHNOLOGY OF GAS EXTRACTION ON THE BASE OF A COAL TO A HYDROGEN TRANSFER

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Organic Chemistry Calculations

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

Performing Calculatons

Protocol: HPLC (amino acids)

SUGAR ESTER SYNTHESIS IN HIGH PRESSURE ACETONE-CO 2 SYSTEM

Gel Filtration Standard

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

MOLES, MOLECULES, FORMULAS. Part I: What Is a Mole And Why Are Chemists Interested in It?

MINERAL OIL (MEDIUM VISCOSITY)

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

SUCRALOSE. White to off-white, practically odourless crystalline powder

Analyzing Small Molecules by EI and GC-MS. July 2014

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Diffusion and Fluid Flow

Amino Acid Analyzer L-8900

Chapter Test B. Chapter: Measurements and Calculations

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

ETC -SV. Class 0 oil-free compressed air through catalysis

TCI Chiral HPLC Column

TiO 2. : Manufacture of Titanium Dioxide. Registered charity number

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

Transcription:

CONTINUOUS FRACTIONATION OF FRIED OIL BY SUPERCRITICAL CO 2 AND HEXANE L. Sesti Osséo*, T. Capolupo, E. Reverchon Dipartimento di Ingegneria Chimica e Alimentare, Università degli Studi di Salerno, Via Ponte Don Melillo, 84084 Fisciano (SA), Italy FAX +39089964057, E-Mail: lsestiosseo@unisa.it ABSTRACT Fractionation of fried oils by Supercritical Carbon Dioxide (SC-CO 2 ) might be a suitable purification technique, since a selective separation of the oil components can be attained [1, 2, 3]. Unfortunately, the specific quantity of CO 2 with respect the oil is fairly high [2, 3] and thus the operating cost is estimated to be high [4]. The use of hexane as cosolvent has been tested to reduce it. The influence of the hexane concentration at selected operating condition (P = 35 MPa and T = 50 C) has been tested at constant ratio oil-hexane (60% vol). Ratio between CO 2 and oil has been reduced from 52 down to a 22 kg/kg at constant CO 2 flow rate. Fractionation yields and composition of products has been analysed and discussed. Experimental results indicate that the use of hexane can allow a significant CO 2 flow rate reduction maintaining the oil composition and recovery substantially constant at column top. Nevertheless, the presence of some percentage of hexane residue in the oil has been detected and further treatments are necessary. INTRODUCTION Fractionation of fried oils to recovery triglycerides components is receiving an increase of interest because of the recent availability in many countries of collected fried oils. A large part of fats and oils in the world is used for the preparation of fried foods. During deep fat frying a significant quantity of oil is heated for a long period and a complex series of chemical changes during frying occur. Fried oil, as a consequence of oxidation, polymerisation and hydrolysis reactions, contains a variety of undesired substances such as oligopolymers, oxidized triglycerides, sterols and fatty acids. The discharged fried oil still has a large portion of triglycerides, but there are also volatile compounds, that include hydrocarbons, aldehydes and ketones, and polymers, that include mostly triglycerides dimers (DPTG), which were not even detectable in fresh oil [4]. Oil composition is usually considered as a mixture of three class of compounds: Low Molecular Weight Components (LMWC), Triglicerydes (TG) and Higher Molecular Weight (POL) [1, 2, 3]. Moreover, Acidity and Peroxide Value (PV) parameters are often used to characterize the oil, these are determined according to standard methods specified in European Commission Regulation 2568/91 [5].

Tab 1. Fresh oil and fried oil properties. POL % TG % LMWC % Acidity % PV meq O 2 /Kg Fresh Peanuts Oil 3.6 93.0 3.4 0.11 5.59 Fried Peanuts Oil 39.7 59.6 0.7 0.8 12 Table 1 shows a fresh and a fried oil. Fried oil exhibits a strong increase in the POL, corresponding to a sharp decrease in TG content; moreover, POL increases both values, Acidity and PV. The recent availability of recovered fried oil, now possible in many countries because of environmental protection law, encourages to find new techniques able to valorise the collected material. The fried oil can be treated with supercritical carbon dioxide (SC-CO 2 ) to fractionate TG; LMWC and POL. This technique allows a very interesting TG recovery and purity [2, 3]. Nevertheless the specific quantity of CO 2 with respect the oil that is fairly high and thus the operating cost is expected to be high [4]. Hexane has been selected as cosolvent because this is an excellent solvent for the vegetable oils, well accepted in oil processing. Moreover the hexane was the original solvent and oil separation is easy and almost quantitative in SC-CO 2 packed tower [6, 7]. MATERIALS AND METHODS Peanut fried oil was obtained from our university canteen after 36 hours (three cycles of 12 hours) of frying fish at 150 C in an industrial frying machine. Carbon dioxide (purity 99 %) was supplied by S.O.N. (Naples, Italy) and hexane (purity 95 %) by Sigma Aldrich. The Acidity and Peroxide Value parameters of the oil were determined according to standard methods specified in European Commission Regulation 2568/91 [5]. All analytical reagents were bought by Sigma-Aldrich, Italy. Since the analysis of the exact distribution of the different compounds in the oil is out of the scope of this work, we decided to evaluate the oil composition on the basis of the molecular weight of the three main components of the oil: LMWC, TG, POL. Molecular weights of these compounds were determined by High Pressure Size Exclusion Chromatography (HPSEC). We used a HP 1100 chemstation equipped with a 20 µl injector loop, a UV detector set at 230 nm, and two PLGel columns (Perkin-Elmer, U. K.) 30 cm x 0.75 cm. A HP 1100 Chemstation equipped with a 20 µl injector loop, UV detector set at 230 nm, and two PLGel columns (Perkin-Elmer, U. K.) 30 cm x 0.75 cm, was used. The two columns were packed with 5 µm cross-linked styrene-divinylbenzene copolymer particles having a pore diameter of 100 and 500 Å respectively. The elution solvent was Methylene Chloride at 0.8 ml/min flow rate. A sample having a concentration of 1.75% w/v was injected at T =25 C. The elution time of each class of compounds has been determined against three standards supplied by Supelco. The composition of DPTG, TG and LMWC in the samples was determined by calculating the relative area of each peak. The hexane content has been determined through static headspace gas chromatography. Adsorbent column was Agilent 19091J-413, 30 m long and 0.3 mm of diameter, support was HP 95-5% Phenyl Methyl Siloxane. Vial volume was 20 µl, heated at 170 C and equilibration time 15 min. The loop temperature was 175 C / 180 C, duration 7 min. Tranfer line between vial and headspace has been set at 180 C. Gas carrier are H 2 (30.0 ml/min) and Air (400 ml/min).

A scheme of the experimental apparatus is shown in Figure 1. The column, 1920 mm long, is cylindrical, i.d. of 17.5 mm, O.D. of 25.4 mm. It consists of 5 sections (Autoclave Engineers), 305 mm long connected to each other and to the process lines by 6 similar 4-port elements. Two ports (17.5 mm ID) are utilized for column connection, two (6.35 S-2 mm) are for piping or and instrumentation use. All parts are made in AISI 316 stainless steel S-1 and are designed to withstand up to a maximum internal pressure of 70 Mpa at 30 C. The column is packed with stainless steel packing 5 mm nominal size with 1600 m -1 specific surface and 0.9 T-1 voidage. The temperature along the column is controlled by five PID controllers (Watlow Model E-1 965). CO2 is fed to the column by a high-pressure diaphragm pump (Milton Roy Model Milroyal B), that can deliver CO 2 flow rates up to 12 kg/h and that is provided with a cooled head. The CO 2 temperature at the column inlet is controlled by a PID controller. Figure 1. Experimental Apparatus. T-1 Supercritical tower TC Temperature controller S-1 First Separator FC Flow controller S-2 Second Separator PI Pressure indicator P-1 Oil and hexane pump TI Temperature indicator P-2 CO 2 pump FI Flow indicator E-1 CO 2 Cooler SP sample point. Similar temperature-controlling techniques are also adopted for the liquid feed. The oil, mixed with hexane, is withdrawn directly from a reservoir, and fed to the column by a piston pump (Milton Roy Model Minipump). The stream exiting from the top of the column is depressurized to 8 MPa by local pressure control valve and 30 C and then the top stream is fed to a second separator, kept 2 MPa and 30 C. The oil fractions are collected at the bottom of the tower and at the first and second separator bottom. A rotameter and a dry test meter measure approximately at atmospheric pressure the CO 2 flow rate (before oil/hexane feeding) and during normal operation, the total quantity of CO 2 and cosolvent flowing. Extract and raffinate samples were weighted and analyzed according to the analytical procedures. The product yields are calculated by the ratio of target product with respect of the total amount of liquid from the two separators and bottom of the column.

RESULTS AND DISCUSSION Experiments have been carried out maintaining constant the main flows in the column. Because CO 2 flow rate is largely higher with respect to fried oil, during experiments this flow rate has been kept constant, whereas oil and cosolvent flow has been changed. The first set of measurements was realized in order to test the hexane co-solvent effect. For this reason the packed tower has been operated maintaining constant the pressure at 35 MPa, the temperature at 50 C, the CO 2 flow rate at 24 g/min and the oil flow rate at 0.45 g/min. Fractionation at this condition was tested in a previous work [2]. With respect to this experiments, hexane flow rate has been progressively added to feed, starting from 0 up to 0.44 g/min of hexane, corresponding to the range 0-60% vol for oil-hexane mixture and to 0-2.5 of ratio hexane- CO 2. Thus CO 2 flow rate has been continuously reduced from 53 down to a 23 kg of CO 2 /kg of oil, when the ratio oil/hexane feed is constant (60% vol of hexane). Top and bottom fractionation and their products composition has been analysed. Fig. 3 shows the top oil recovery as total and fractional in the first and in Fractional recovery % Overal top oil recovery 1,0 0,5 Hexane/CO 2 0,0 0,5 1,0 1,5 2,0 2,5 Top Bottom 0,0 0 10 20 30 40 50 60 100 80 60 40 20 Hexane/Oil mixture, vol % Figure 2. Recovery at top (open triangle) and bottom (filled triangle) fraction as a function of hexane to CO 2 ratio. I separator II separator Total (I+II separator) 0 20 25 30 35 CO 2 /Oil ratio (/) Fig 3. Overall oil recovery on top of tower at 35 Mpa and 323 K (60% vol of hexane in oil/hexane mixture).

Total top composition () I Separator composition () 100 80 60 40 20 100 TG POL LMWC Hexane 0 20 25 30 35 80 60 40 20 CO 2 /Oil ratio (/) Fig. 4 Overall composition in the top fraction of the column operated at 35 MPa and 323 K, 60% hexane in the feed. TG POL LMWC Hexane 0 20 25 30 35 CO 2 /Oil ratio (/) Fig. 5 Composition of the liquid collected at the first sepator. Column is operated at 35 MPa and 323 K, 60% hexane in the feed, separator is at 8 MPa and 303 K the second separator, as a function of the flow rates ratio CO 2 /oil. Coming down from value 1 corresponding to ratio oil/hexane 53 (not shown in Fig. 3), a progressive reduction of total top recovery can be observed in the range experimentally investigated (limited by feed oil pump capacity). The value of top oil recovery is consistent with TG content in the feed; and the first separator (pressure at 8 MPa, T=30 C) collect the greater part; the second separator (pressure at 2 MPa, T=30 C) collects the remaining, in the range from 10% to 20%. Fig. 4 shows the composition of the oil collected at the first and second separator, as a function of CO 2 /oil oil ratio. With respect to the most valuable components, i.e. TG, composition ranges from about 70% corresponding to a CO 2 /oil ratio of about 22, up to 90% at greater values of Fig. 4. Fig. 5 shows the liquid composition collected at the first separator, set at temperature of 303 K and pressure of 8.0 MPa. The results of TG concentration Vs CO 2 /oil ratio are higher than 90% and substantially constant. Hexane contents ranges between 1.5 and 2.9. So, if hexane is removed, TG, POL and LMWC composition are not far from the original values (see Tab.3).

Tab 3 Oil composition at first separator, base free of hexane CO 2 /Oil Ratio (/) POL TG LMWC 32.60 5.54 93.22 1.23 29.86 5.33 94.67 0 26.41 4.54 93.52 1.94 21.84 5.81 92.93 1.26 Fresh oil 3.6 93.0 3.4 CONCLUSION Hexane has been demonstrated an effective cosolvent for fried oil in supercritical fractionation using CO 2. The experiments carried out in this work show that cosolvent can reduce in two possible way operating cost of the separation: 1. reduction CO 2 flow rate 2. maintaining at high level the separator pressure With respect to the first point, it is clear that operating costs are well approximated by a linear dependence to CO 2 flow rate. So, CO 2 flow rate reduction higher than 50% as here shown has an high impacts on operating cost. With respect to the second point, it should be noted that a separation above CO2 critical pressure could have a positive impact on cost, avoiding the CO 2 condenser need. Nevertheless, the hexane presence makes the flow sheet more complicated (and more expensive) also using supercritical CO 2 techniques. REFERENCES 1. Yoon, J., Han, B.S., Kang, Y., Kim, K.H., Yung, M.Y. and Kwon, Y.A., Food Chemistry, 71, 2000, p. 275. 2. E. Reverchon, L. Sesti Osséo, G. Caputo and I. Gracia, 6th Int. Symp.on SF, Versailles, 2003, p. 397 3. L. Sesti Osséo, G. Caputo, I. Gracia, and E. Reverchon, J.A.O.C.S., Vol. 81, 2004, p. 879 4. L. Sesti Osséo, M. Poletto, E. Reverchon, 6 th Conf. on SF and Their Applications, Maiori, 2001, p. 81 5. European Parlament, docunents PE - 289.889, 2001 6. M. Poletto, L. Sesti Osséo, G. Della Porta, E. Reverchon, 7th Meeting on SF, Antibes, 2000, tome 1, p. 745 7. E. Reverchon, M. Poletto, L. Sesti Osséo, M. Somma, J.A.O.C.S., vol. 77 no. 1, 2000, p. 9