Indirect fired heaters



Similar documents
Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS

Condensing Boiler Efficiency

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Energy Efficiency in Steam Systems

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Combined Cycle Control Overview

Factory owners must ensure the boiler is:

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Originators of the Flexible Water Tube design

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Hot water supply, distribution and use

SULFUR RECOVERY UNIT. Thermal Oxidizer

Guidelines for Preparing for a Temporary Steam Plant

High Efficiency Heating

Electric Process Heaters & Engineered Systems

Committed to make a better world

Gas-Fired, Residential Storage Type Water Heaters

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

COLORADO APCD IR Camera Survey Program Guidance/Protocol (rev. 11/8/11)

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Presentation Outline. Background

Session 2: Hot Water Supply

Fired Heater Design and Simulation

DIRECT-FIRED HEATERS: OPERATOR TRAINING. Intensive 2-Day Training Course for Facility Operators

System Solutions for Boiler Air Preheating

The soot and scale problems

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

Solar Hot Water Heaters

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Boiler NOx Emissions and Energy Efficiency

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

I. STEAM GENERATION, BOILER TYPES

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Backup Fuel Oil System Decommissioning & Restoration Plan

Steam System Best Practices Condensate System Piping

Efficiency on a large scale CFB Steam Boilers

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Bosch Commercial and Industrial Heating High efficiency steam boilers (175kg/h to 55,000kg/h)

Propane-Fueled Microturbine: Case Study

Commercial Boiler Systems and Controls

Improving Energy Efficiency through Biomass Drying

SUPERSONIC GAS CONDITIONING - COMMERCIALISATION OF TWISTER TECHNOLOGY

BorsodChem MCHZ, Czech Republic. 6,000 Nm 3 /h HTCR Topsøe Hydrogen Plant A Case Story: 18 Months from Engineering to Operation

Integrated Solar Radiant Systems

Solar Hot Water. What systems are available?

Commercial Gas Water Heaters

Industrial Steam System Process Control Schemes

1 DESCRIPTION OF THE APPLIANCE

Boiler Efficiency. Charles Stark Department of Poultry Science.

Hot Water Heating: Technologies and Use

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Boiler Preparation, Start-Up and Shutdown

RPV - RP - RA air handling units

Natural Gas Conversions of Existing Coal-Fired Boilers

Boiler System Efficiency

What is a successful Steam Trap Management Program?

Exam on Heat and Energy

Nominal Life Expectancy for Building Components

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

Your Boiler Room: A Time Bomb?

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

PHOENIX ENERGY of NEVADA, LLC (PENV) (PENV)

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

Continuous flow direct water heating for potable hot water

How To Understand Evaporator

Building Energy Systems. - HVAC: Heating, Distribution -

Commercial Gas Water Heaters

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Solar Thermal Systems

C. starting positive displacement pumps with the discharge valve closed.

TECHNICAL CHARACTERISTICS

Marine Boilers. From a world class boiler manufacturer

OROT RABIN POWER STATION UNITS x 350 MW

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Efficiency Options for Thermal & Catalytic Oxidizers

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007

Heat recovery. Ian Matthews Sales & Marketing Director Gasco

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Center for Energy Education Laboratory

INDEX GENERAL

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

How To Power A Power Plant With Waste Heat

Balance of Fuel Cell Power Plant (BOP)

Arkansas Natural Gas Severance Marketing Costs

TABLE OF CONTENT

Heat Recovery In Retail Refrigeration

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

Routine and Emergency Boiler Operation

Transcription:

Indirect fired heaters

Indirect Fired Heaters General INDIRECT BATH HEATERS have a wide variety of successful applications in the oil and gas production, processing and transmission industry. Some of the most common application include the following: 1. Gas Dew Point Heating: high-pressure natural gas heating upstream pressure regulation stations preventing condensation phenomena due to the Joule-Thomson effect. 2. Heating of high-pressure natural gas upstream pressure regulation in order to prevent external icing formation. 3. Fuel gas super-heating upstream gas turbines (Performance haters) 4. Gas heating downstream low temperature storages 5. Hydrate prevention 6. Viscosity reduction: Crude Oil Heating upstream treatments to facilitate degassing and dewatering. Range: The duty of Pietro Fiorentini heaters can vary from 90Kw up to 10Mw.

Main features Indirect Bath Heaters are composed of the following main parts: - Main body - The coil or tube bundle - The water expansion tank - The fuel feed line - Burner (gas type, oil type or bi-fuel) - The fire-tube - Chimney - Burner management system panel - Skid frame and service platform - Insulation The heater shell contains the fire-tube that allows a rapid heat transfer (both radiant and convective) from the flame to the hot medium. The heat is transferred from the bath to the coil / tube bundle and then safely to the gas or the oil. The expansion tank allow the hot medium to be contained for the thermal expansion due to the temperature increase. Level gauges and transmitters advise when additional water or hot medium is required and give alarms in case of overfilling.

External insulation Heaters are thermally insulated, except end sides left bare to facilitate access to the coils, burner or stack. Insulation materials are properly selected based on operating temperature and climate conditions. Forced draft vs natural draft Forced or natural draft heater designs are available depending on working conditions and power availability on site. Natural draft burner relies on a stack to create negative pressure at the burner inlet, which induces as much air as is required for combustion. These heaters are popular for remote locations and/or locations with limited or even no power supply available. Forced draft heaters are ideal whenever there is a low emission requirement, utilizing small bore fire-tubes in conjunction with a combustion air fan. High velocities in the small bore fire tube reduce the dead gas film region along the tube walls. This results in a reduced tube areas compared to their large bore counterparts, therefore, overall heater size is minimized creating a significantly smaller footprint while offering superior burner control compared to natural draft style heaters. API 12K OFFICIAL MONOGRAM PIETRO FIORENTINI is one of the few companies worldwide bearing the API 12K monogram confirming the full compliance of Indirect Heaters to API (American Petroleum Institute) specifications.

Indirect fired gas heater (water bath heaters) Tailor designed according to customer specification and design conditions they can have different configurations: GAS PIPE INSIDE THE HEATER: AIR DRAFTS: BURNERS HEAT SOURCE: HOT MEDIUM: Tube bundle or coil. Natural circulation or forced flow. Low NOx or conventional, mono-fuel or bi-fuel Gas, oil or electricity. De-mineralized Water, Glycol, hot oil, Thermal B The operation of the gas heaters is completely automatic. Gas heaters are fired with natural gas which will be supplied to the burner at a specific pressure thanks to a dedicated fuel gas pressure regulators complete of all the required safety devices and electrical heating on a dedicated line.

HOT OIL HEATER Used in order to reduce the viscosity to ease the oil stream transportation. The hot medium can be water, hot oil, Glycol or Thermal B. Almost every coil bundle require a tailored design in order to meet the requirements of heat duty, working pressure, corrosion allowance, sour gas service, NACE MR-01-75 and governing specification or normative, usually ASTM or ANSI B 31.3.

Electric heaters All the previous type of heater can be constructed with Electrical heating source. Example of electrical Gas Heating to prevent condensate creation after the gas temperature reducing at the pressure reducing valves for the joule- Thompson effect. On Electrical Heaters the temperature control is operated by a Thyristor systems. FIORENTINI can offer a full range of flameproof heaters, immersion heaters, process flow heaters and electric heating skids for a variety of applications. Typical electric process heating applications include fuel gas heaters, fuel oil heaters, glycol reboilers, TEG heaters, MEG heaters and water heaters.

Pietro Fiorentini Solutions Gas treatment plants Reducing station Ball valve Pietro Fiorentini S.p.A. via E.Fermi 8/10 I-36057 Arcugnano (VI) Italy Tel. +39 0444 968.511 Fax. +39 0444 960.468 The data are not binding. We reserve the right to make eventual changes without prior notice. CT-s 568-E April 10 www.fiorentini.com