Others ph conductivity measurement module ph and conductivity measurement in 96 deep well plates



Similar documents
AIRMoN, ph and Conductivity Field Measurement

SenTix 950 SenTix 980

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Density- & Refractometers

Inventory Control. Inventory Control Tank & Silo Weighing

AxyPrep TM Mag PCR Clean-up Protocol

EQUIPMENT CALIBRATION/MAINTENANCE

USEPA Electrode Method Method 8156

ab vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Operating Instructions

API Marine. BMS Presentation. Ballast Measurement Systems

Experiment 9 Electrochemistry I Galvanic Cell

Powers Controls TH 192 S Single Temperature Room Thermostat

Trace Dissolved Oxygen Sensor

Your Personal Pipetting Robot

Compact ph Measuring Instruments

Fixed and Adjustable Spacing Electronic Pipettes

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

ph Measurement and Control

6 H2O + 6 CO 2 (g) + energy

Milwaukee USER MANUAL

Microwave Meter. Instruction Manual

GC-xt. The most flexible GC /GC-MS liquid sample injector

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Chloride and Salinity

High-Precision Platforms

etape Continuous Fluid Level Sensor Operating Instructions and Application Notes

ph and Acidity in Wine and Fruit Juice

User Manual. Thermo Scientific Orion VERSA STAR

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

cobas 8100 automated workflow series 3-D intelligence in lab automation

Benchmark. WASH l RINSE l PASSIVATE l DRY. Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service

Retail Scale bc: be connected be successful

For additional information, please visit our website at

REDOX AND REFERENCE ELECTRODE USER MANUAL

Experiment 6 Titration II Acid Dissociation Constant

cobas connection modules (CCM) Sample flow solutions for high-throughput laboratories

Let Tecan care about your routine data calculation Magellan and i-control software for Tecan microplate readers

Roadway Plan Production

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Cooking at the Speed of light!

cobas connection modules (CCM) Sample flow solutions for high-throughput laboratories

Household Acids and Bases

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

DISSOLVED OXYGEN PROBE

How To Get Rid Of Small Dna Fragments

Measurement by Ion Selective Electrodes

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

ph and Acidity in Tomato Sauce

Gas Custody Transfer Calibration

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Enzyme Action: Testing Catalase Activity 50 Points

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

AutoCAD Structural Detailing Getting Started with AutoCAD Structural Detailing, Reinforcement module

User Guide IM/AX4PH Rev. O. AX416, AX436, AX460, AX466 & AX468 Single and dual input analyzers for ph/redox (ORP)

ThermoSorb Desiccant Dryers

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ngenieros Ingenieros Asociados De Control S.L.

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

Chemistry 212 VAPOR PRESSURE OF WATER LEARNING OBJECTIVES

LabX titration Software

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

INNOVATION TO MEET YOUR NEEDS

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

XCal-View user manual

Human Luteinizing Hormone (LH) Custom Kit

Determining the Identity of an Unknown Weak Acid

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

ab Protein Sumoylation Assay Ultra Kit

Bourns Sealed Through-Hole Cermet Trimming Potentiometers. Short Form Brochure

MACHEREY-NAGEL NucleoSpin Robot-96 Extract Kit Genesis Freedom Genesis RSP Genesis RWS

A Complete Solution for Method Linearity in HPLC and UHPLC

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

ExStik TM ph Waterproof Meters

Understanding Pressure and Pressure Measurement

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

EQuan MAX Getting Connected Field Service Guide

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Stainless Steel Dissolved Oxygen Electrodes

Multifunctional Autosampler AOC-6000 C146-E272A

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

18 Conductometric Titration

Robot soldering head 4900

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

ADP/ATP Ratio Assay Kit (Bioluminescent)

User Guide Dissolved Oxygen Probes

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

Flow-Through Cell ph SENSOR PROBES. Instruction Manual

Appendix C. Vernier Tutorial

Transcription:

Others ph conductivity measurement module ph and conductivity measurement in 96 deep well plates Technical Reference EU-0850 30078161 Input Process Output 96 well DWP with 2 ml sample Plate is transported by the RoMa to the loading position Storage 48 well plate with storage solution and calibration buffers Automated calibration of the ph electrodes Test the calibration of the conductivity electrodes Simultaneous measurement of ph (4 wells) and conductivity (4wells) Measurement of 12 rows in straight plate orientation (A1) Turn the plate with the RoMa (regrip position) Measurement of 12 rows rotated plate orientation (H12) Washing and drying of electrodes Storage of electrodes in suitable storage solution Text files with calibration and calibration test results for the ph and conductivity electrodes Text files with ph and conductivity and temperature values for each well

System Overview 1 2 7 3 4 5 6 8 10 9 # Type of module Brand, model 1. ph Electrodes Mettler Toledo InLab Micro ph probe without temperature sensor 2. Conductivity Electrodes Mettler-Toledo InLab 751-4mm conductivity probe with temperature sensor 3. Loading position Tecan 4. Electrode dryer Tecan 5. Calibration and Storage Plate Axygen 48 Well Clear V-Bottom 5mL Polypropylene Rectangular Well Deep Well Plate 6. Wash Station Tecan 7. Measurement devices Mettler Toledo, SevenMulti ph/conductivity meter 8. System Liquid Tubing Tecan 9. Waste Tubing Tecan 10. Support Frame Tecan The whole module can be integrated on the right side of a Freedom EVO 100, 150 or 200. An eccentric RoMa is required for loading the plates as well as a regrip station on the Freedom EVO worktable to ensure loading in straight (A1) or rotated (H12) orientation in order to measure all wells. Manufactured by TIG, Tecan Schweiz AG, Seestrasse 103, 8708 Männedorf Switzerland, www.tecan.com, TIGflyer p 2/6

Highlights: TIG parts Parallel measurement with 4 ph- and 4 conductivity probes The minimal immersion depths of the electrodes recommended by the manufacturer are 5 mm for ph and 8-15 mm for conductivity electrodes. Manufactured by TIG, Tecan Schweiz AG, Seestrasse 103, 8708 Männedorf Switzerland, www.tecan.com, TIGflyer p 3/6

Wash station for ph and conductivity electrodes The active wash station washes every tip in a separate well with a duct from below. Wash power can be set in the macro. The overflow water is passively running through the waste tubing. Electrode dryer The 8 channel electrode dryer is working as an air knife with filtered compressed air while the electrodes are moving up through the air flow. Manufactured by TIG, Tecan Schweiz AG, Seestrasse 103, 8708 Männedorf Switzerland, www.tecan.com, TIGflyer p 4/6

Highlights: Freedom EVOware driver Store Macro To avoid drying out of the ph electrode, it can be stored in a suitable ph solution in the first column of the 48 well storage/calibration plate. This position is approached when choosing the lower position. The upper position can be used for exchanging the storage/calibration plate or for long term storage (ph electrodes have to be capped with liquid filled caps provided by the manufacturer) Measure Macro Wash macro For cleaning the electrodes before or after a calibration measure or store step, the wash macro can be used. The parameters are the same as in the measure, calibrate ph or test conductivity macro. It is recommended to wash the electrodes before each calibration or measurement. Manufactured by TIG, Tecan Schweiz AG, Seestrasse 103, 8708 Männedorf Switzerland, www.tecan.com, TIGflyer p 5/6

Calibrate ph Macro The ph calibration is carried out according to the setting of the measurement device. The buffer is detected manually and the user can define the acceptable borders for the slope between two buffers. If desired, the results will be prompted after the calibration and the user can decide if the calibration shall be saved or not. If the data is not shown the calibration will be automatically be saved if the slopes are inside the allowed range. The values are anyway saved in an output file. Test Conductivity Calibration The conductivity calibration test is carried like a measurement, but buffers are stored in the 48 well storage and calibration plate. The user defines the acceptable borders for expected value for each buffer to be measured. If desired, the results will be prompted after the measurement and the user can decide if the process shall proceed or not. The values are anyway saved in an output file. Scientific instrumentation; not for use in human, clinical or diagnostic procedure. All systems or products are tailor-made one-offs that were exclusively developed on customer demand. All displayed pictures and images originate from development-, test- or installation phases and do not claim to represent the final installation at customer site. All mentioned trademarks are protected by law. In general, the trademarks and designs referenced herein are trademarks, or registered trademarks, of Tecan Group Ltd., Männedorf, Switzerland. A complete list may be found at www.tecan.com/trademarks. Product names and company names that are not contained in the list but are noted herein may be the trademarks of their respective owners. 2014, Tecan Trading AG, Switzerland, all rights reserved. For disclaimer and trademarks please visit www.tecan.com Manufactured by TIG, Tecan Schweiz AG, Seestrasse 103, 8708 Männedorf Switzerland, www.tecan.com, TIGflyer p 6/6