HL Series - Commercial Heaters Tankless Water Heating Solutions



Similar documents
Light Duty Commercial Electric Water Heater

Installation C1N Series Tankless Heater Models

Explosion-Proof Electric Unit Heaters

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Commercial Electric Water Heater

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Tempra / DHC-E. Simply the Best The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

ASME Packaged Indirect Fired Water Heater

PLUMBING SUBMITTAL

Commercial Electric Water Heater

MAC-120HE-01 Air-Cooled Chiller

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

Screw Plug Immersion Heaters

AIR LINE VALVES AND GAUGES

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

! WARNING. Before using product, read and understand instructions.

FIRING RANGE PHASE 1 DESIGN

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Sanitary Type Electronic Flow Switches

Commercial Gas Water Heaters

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

MUELLER FALLING FILM CHILLERS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Centro-Matic Automatic Lubrication Systems System Controls

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Legacy Chiller Systems, Inc

Heating Cable. Construction

In-Line Electronic Flow Switches

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

VSO MAX HP High Flow Proportional Valve

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Commercial Semi-Instantaneous Water Heaters

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

T&P and ASME Safety Relief Valves

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

FLASH TANK ECONOMIZER PRODUCT GUIDE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Generator DoCKInG StatIonS

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

SIOUX HYBRID WATER HEATER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Electronic Flow Switches

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

High kw Electric Tankless Water Heater Troubleshooting Guide

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

ELEC ELE TR CTRIC P IC PRODUCTS RODUCT

TANKLESS DURABILITY Tankless Product Guide

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Installation Manual CLIFC Fan & Coil Variable Speed

Model 1210C Battery Powered Pump Shown. Description

ice 3 FLUID TO FLUID HEAT PUMP

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Commercial Gas Furnace Upflow

SOLI TANKLESS PRODUCT GUIDE

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Stainless Steel Single and Dual Circulation Kits

Overheating limit control

PRESSURE REDUCING CONTROL VALVE

EMERGENCY PLUMBING FIXTURES

4 Posiflow Proportional Solenoid Valves

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

REGULATORS 175/153 Series

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

INSTALLATION GUIDE AND OWNER S MANUAL

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

Oil and Coolant Circulating Heating System. Model - OCSM

Turbine Flow Sensor Series VTR

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

300 Series PA Pump and Cooler Assemblies

Electric Mini Tank Water heaters GL GL 4 - GL 6+

NAVIEN AMERICA INC FITCH AVENUE

"EC" Series Electric Humidifier

Aquamax Australia Pty Ltd ABN

Morrison Bros. Co. General Product Specifications

Solar Skies Stainless Tank Series Water Heater

Electric Tankless Water Heater

Technical Information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Applications manual. For tankless and point-of-use water heaters

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Low Voltage Transformers Sealed, General Purpose, Dry Type

Float and Thermostatic Traps Series H, C and X

Transcription:

HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage NEMA 1 enclosure 3/4" connections ETL certified to UL Standards Liquid-Cooled Triac Switches Surface Mounted Bi-Metal Thermostat with Manual Reset Internal fusing (included) adds safety and permits single power connection Standard Equipment Tankless Water Heating Specifications Keltech, Inc. HL-Series Tankless Water Heaters are designed to accommodate most commercial fluid heating applications including: environments where demand is < 18kW and total flow is 7 GPM, and environments where lower activation flows are required: standard units are.5 GPM with options as low as.15 GPM. HL-Series units are also suited to applications where only single phase service is available or 3-Phase 208V, 240V and 480V is required. HL Series products include a NEMA 1 enclosure as standard, with NEMA 4 and 4X options available. Construction Temperature Controller Keltech's PID Temperature Controller is more energy efficient and reliable than traditional microprocessors using staged elements. Power is infinitely variable, with no fixed inputs. The PID controller makes it possible to modulate the amount of power applied to the elements while also dispersing the required power evenly across all elements. This unique feature increases the product's life cycle. Heating Element Each heater features a heavy duty, low watt density, incoloy 800 sheathed resistive element. The Keltech design ensures greater protection, durability and resistance to scaling from hard water because water is only heated when flowing; this means sediment will not collect in the heat exchanger. Triac Switches The liquid cooled, triac switches provide silent switching which has a faster response than mechanical relays to assist in maintaining an accurate temperature. Electrical The HL-Series requires only one service feed per unit. Includes internal fusing as standard. Internal fusing provides superior protection so the incoming circuit can be higher than 48 amps (NEC). Keltech protects both hot sides of each heating element with fusing. Independent Safety The surface mounted bi-metal thermostat with manual reset acts as a fail-safe. In the event the temperature limit is exceeded, it must be manually reset before power is restored to the elements. Cabinet Enclosure Standard cabinet enclosure is NEMA 1 rated and made from 18 gauge electro galvanized and powder coated steel. The HL-Series also features an optional 18 gauge NEMA 4 enclosure with ANSI 61 gray, corrosive resistant paint. The NEMA 4X enclosures are for harsher environments made from 16 gauge 304 stainless steel. The NEMA 4X enclosure can also be specified with 316 stainless steel. Page 1 of 6 12/3/2015 Code Compliance and Certifications Certified to NSF/ANSI 372 Lead-Free Products marked with the Lead-Free logo comply with the Safe Drinking Water Act (SDWA) requirements of a weighted average of less than 0.25% lead content on wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures. ETL listed to UL499 Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Product Options Building Management System Integration The D1 option transfers control of the heater to a Building Management System (BMS). The heater is no longer adjusted or controlled at the heater location. 4-20mA input for integration with BMS. The D1 option requires selecting a NEMA 4/4X cabinet enclosure. Other Product Options For additional heater options and installation accessories, reference the appropriate section at the end of this document.

Electrical Specifications for the Heater (1-Phase) HL Series - Commercial Heaters HL Pressure Drop Advantage All internal fuses necessary for installation are included with the unit. Capacity (kw) Voltage Maximum Amperage Minimum AWG Wire Size 5 208 25 10 5 240 21 10 6 208 29 8 6 240 25 8 6 277 22 10 6 480 13 12 10 208 48 4 10 240 42 6 12 208 58 4 12 240 50 4 12 480 25 8 12 277 43 6 15 208 72 3 15 240 63 3 18 208 87 3 18 240 75 3 18 277 65 3 18 480 38 6 Pressure Drop GPM 1 2 3 4 5 6 7 PSI 0 2 4 8 12 17 24 L-MIN 3.8 7.6 11.3 15.1 18.9 22.7 26.5 BAR 0.0 0.1 0.3 0.5 0.8 1.2 1.6 Electrical Specifications for the Heater (3-Phase) All internal fuses necessary for installation are included with the unit. Capacity (kw) Voltage Maximum Amperage Minimum AWG Wire Size 10 208 28 10 10 480 13 12 15 208 42 6 15 240 36 6 18 208 50 4 18 240 43 6 18 480 22 10 Page 2 of 6 12/3/2015

HL Series - Commercial Heaters HL Series - NEMA 1 Dimensions (mm) Select product options shown. Other options available. HL Inlet 3/4" Copper HL Outlet 3/4" Copper 4.7" (119) 1.1" (28) 13" (330) 2" (51) 11" (279) 2.75" (70) 13.5" (343) 23" (584) Side View 14" (356) Back View (Mounting Holes) Front View Outlet Inlet Ball or Gate Valves 1.3" (33) 1.5" (38) Pressure Relief Valve (if Local Code Requires) Y-Strainer, 100 Micron Recommended Bottom View 1.3" (33) Inlet, 3/4" Copper Threaded Unions Inlet, 3/4" Copper Suggested Installation Configuration Components provided by installer unless otherwise specified. Reference the product options sections or contact your local Bradley Representative for product options. Page 3 of 6 12/3/2015 Power Entrance

HL Series - NEMA 4/4X Dimensions HL Series - Commercial Heaters (mm) Select product options shown. Other options available. 3/4" Female NPT Outlet 2" (51) 11" (279) 3/4" Female NPT Inlet 2-5/16" (59) 25-1/2" (648) 24" (610) Front View 14-1/2" (368) 16" (406) 7" (178) N4 8-3/4" (222) N4X Side View Page 4 of 6 12/3/2015

kw Calculator HL Series (kw): 5, 6, 10, 12, 15, 18 HL Series - Commercial Heaters Flow Temperature Δ F ( C) 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 GPM L-MIN (6 ) (8 ) (11 ) (14 ) (17 ) (19 ) (22 ) (25 ) (28 ) (31 ) (33 ) (36 ) (39 ) (42 ) (44 ) (47 ) (50 ) (53 ) (56 ) (58 ) (61 ) (64 ) (67 ) (69 ) (72 ) (75 ) (78 ) 0.15 0.6 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 0.25 0.9 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 0.50 1.9 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 10 10 10 10 10 10 10 10 10 10 10 12 0.75 2.8 5 5 5 5 5 5 5 5 6 6 10 10 10 10 10 10 10 12 12 12 15 15 15 15 15 15 18 1 3.8 5 5 5 5 5 6 6 10 10 10 10 10 12 12 12 15 15 15 15 18 18 18 18 - - - - 1.5 5.7 5 5 5 6 10 10 10 10 12 15 15 15 18 18 18 - - - - - - - - - - - - 2 7.6 5 5 6 10 10 12 12 15 15 18 18 - - - - - - - - - - - - - - - - 3 11.3 5 10 10 12 15 18 18 - - - - - - - - - - - - - - - - - - - - 4 15.1 6 10 12 12 18 - - - - - - - - - - - - - - - - - - - - - - 5 18.9 10 12 15 - - - - - - - - - - - - - - - - - - - - - - - - 6 22.7 10 15 18 - - - - - - - - - - - - - - - - - - - - - - - - 7 26.5 12 18 - - - - - - - - - - - - - - - - - - - - - - - - - Sizing for the proper flow rate is important. If the temperature rise requirements exceed a single HL model, consider using multiple HL-Series units or the C1N & C2N Series. Please contact your Keltech Representative for additional product information. How to Size a Heater 1. Calculate Delta-T ( T). Set point temp - coldest ground water temp = T T = 2. Select kw required by using chart or formula below. Peak demand in GPM x T x.1465 = kw kw = 3. Confirm voltage and phase available on site. Voltage and Phase = 4. Confirm minimum flow. Minimum Flow = Page 5 of 6 12/3/2015

HL Series - Commercial Heaters Standard Product - HL Series (Single Phase) 5kW Commercial Heaters HL050/208D Single Phase 5kW, 208V Commercial Heater HL050/240D Single Phase 5kW, 240V Commercial Heater** 6kW Commercial Heaters HL060/208D Single Phase 6kW, 208V Commercial Heater HL060/240D Single Phase 6kW, 240V Commercial Heater HL060/277D Single Phase 6kW, 277V Commercial Heater HL060/480D Single Phase 6kW, 480V Commercial Heater 10kW Commercial Heaters HL100/208D Single Phase 10kW, 208V Commercial Heater HL100/240D Single Phase 10kW, 240V Commercial Heater** 12kW Commercial Heaters HL120/208D Single Phase 12kW, 208V Commercial Heater HL120/240D Single Phase 12kW, 240V Commercial Heater HL120/277D Single Phase 12kW, 277V Commercial Heater HL120/480D Single Phase 12kW, 480V Commercial Heater 15kW Commercial Heaters HL150/208D Single Phase 15kW, 208V Commercial Heater HL150/240D Single Phase 15kW, 240V Commercial Heater** 18kW Commercial Heaters HL180/208D Single Phase 18kW, 208V Commercial Heater HL180/240D Single Phase 18kW, 240V Commercial Heater HL180/277D Single Phase 18kW, 277V Commercial Heater HL180/480D Single Phase 18kW, 480V Commercial Heater ** This specific model may have a longer lead time if ordered with the TE2 option. Only 480V heaters can be down rated to 380, 400 and 415 volts. Enhanced Performance Tuning Please select your type of application. Keltech will precisely "tune" your heater specifically to your application for the highest level of performance at no additional charge. Process Heating Potable Boosting Re-Circulating Model Number Configuration Standard Product - HL Series (Three Phase) 10kW Commercial Heaters (Three Phase) HL103/208D Three Phase 10kW, 208V Commercial Heater HL103/480D Three Phase 10kW, 480V Commercial Heater 15kW Commercial Heaters (Three Phase) HL153/208D Three Phase 15kW, 208V Commercial Heater HL153/240D Three Phase 15kW, 240V Commercial Heater** 18kW Commercial Heaters (Three Phase HL183/208D Three Phase 18kW, 208V Commercial Heater HL183/240D Three Phase 18kW, 240V Commercial Heater HL183/480D Three Phase 18kW, 480V Commercial Heater Product Options D1* 4-20mA Input for Integration with Facility Controls* IC Temperature Lock Out at F (40-160 F) or C (5-71 C) L15 Low Flow.15 GPM Turn On Point L25 Low Flow.25 GPM Turn On Point N4 NEMA-4 Enclosure (NEMA 1 Standard) N4X NEMA-4X Enclosure - Stainless Steel N4-EXP2 NEMA-4 Enclosure w/ Explosion Proof Class1/Division2 N4X-EXP2 NEMA-4X Stainless Steel Enclosure w/ Explosion Proof Class1/Division2 T190 High Temperature Package (Specify temp between 160 F and 190 F) TE2 Xylan Fluoropolymeric Coated Heat Exchanger with Bright Annealed Stainless Steel Elements, FDA Approved for Food Contact (Use in deionized water applications) * D1 requires NEMA 4 or NEMA 4X Enclosure Installation Accessories BSPP Stainless steel thread adapter converts NPT to BSPP PR Pressure and Temperature Relief Valve PRS ASME pressure relief valve, stainless steel YS Y-Strainer YSS Y-Strainer, stainless steel Use with NEMA 4 or NEMA 4X Enclosure only. Keltech Tankless Water Heaters are non-cancelable, non-refundable and non-returnable. Application Attributes (MANDATORY) Coldest ground water temperature: Minimum Flow: Maximum Flow: Set point temperature: Delta T Calculation Set Point Temperature - Coldest Incoming Water Temperature = Minimum Delta T for Application HL / D- - - - - - - - List applicable option codes alphabetically. Do not include Installation Accessories in configuration. Customer Signoff Page 6 of 6 12/3/2015