SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. AM-480800A1TZQW-A0H APPROVED BY DATE Approved For Specifications Approved For Specifications & Sample AMPIRE CO., LTD. 4F., No.116, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City221, Taiwan (R.O.C.) 新 北 市 汐 止 區 新 台 五 路 一 段 116 號 4 樓 ( 東 方 科 學 園 區 A 棟 ) TEL:886-2-26967269, FAX:886-2-26967196 or 26967270 APPROVED BY CHECKED BY ORGANIZED BY Date : 2012/01/10 AMPIRE CO., LTD. 1
RECORD OF REVISION Revision Date Page Contents Editor 2012/01/10 -- New Release Eric Date : 2012/01/10 AMPIRE CO., LTD. 2
1 Features Ampire 4.3 Display Module is a color active matrix TFT-LCD that uses amorphous silicon TFT as a switching device. This model is composed of a TFT-LCD panel and LED Backlight. This TFT-LCD has a high resolution (480(R.G.B) X 800) and can display up to 262,144 colors. (1) Construction: 4.3 a-si color TFT-LCD, White LED driver & Everlight middle power LED Backlight and PCB. (2) Main LCD : 2.1 Amorphous-TFT 4.3 inch display, Normally black type (MVA). 2.2 480(RGB)X800 dots Matrix,1/800 Duty. 2.4 Main LCD Driver IC: ILI9803 2.5 262K: Red-6bit, Green-6bit, Blue-6bit (18-bit interface) (3) Interface : 6-bit LVDS Interface (4) LCD Power Supply Voltage : 3.3V (5) Build-in LED Driver IC (VLED=3.3V~5V) 2 Mechanical specifications Dimensions and weight Item Specifications Unit External shape dimensions *1 63.18 (W) x 107.35(H) X 7.56(D). mm Pixel size 0.117 (W) x 0.117 (H) mm Main LCD Active area 56.16 (W) x 93.6 (H) mm Number of Pixels 480(H)x800(V) pixels mm Weight 64 g *1. This specification is about External shape on shipment from AMPIRE. 3 Absolute max. ratings and environment 3-1 Absolute max. ratings Ta=25 o C GND=0V Item Symbol Min. Max. Unit Remarks Power voltage VCC GND -0.3 +3.6 V Power voltage VLED GND -0.3 +6 V Input voltage VIN -0.5 VCC+0.3 V Date : 2012/01/10 AMPIRE CO., LTD. 3
3-2 Environment Item Specifications Remarks Storage temperature Max. +80 o C Min. -30 o C Note 1: Non-condensing Operating temperature Max. +70 o C Min. -20 o C Note 1: Non-condensing Note 1:Ta +40 o C Max.85%RH Ta>+40 o C The max. humidity should not exceed the humidity with 40 o C 85%RH. 4 Electrical specifications 4-1 Electrical characteristics of LCM (V CC =3.0V, Ta=25 o C) Item Symbol Conditions MIN. TYP. MAX. Unit Input power voltage LED driver input voltage High-level input voltage Low-level input voltage Consumption current of VCC Consumption current of VLED 1. 1/800 duty. V CC 2.5 2.8 3.3 V V LED 2.5 5 5.5 V IHC 0.8V CC V CC V V ILC 0 0.2V CC V I CC LED OFF - 45 65 ma I LED V LED =5V - 210 230 V LED =3.3V - 350 380 ma Date : 2012/01/10 AMPIRE CO., LTD. 4
4-2 LED back light specification Item Symbol Conditions MIN. TYP. MAX. Unit Forward voltage V f I f =100mA 8.7 9.9 10.8 V Reverse voltage V r - - 15 V Forward current I f 3-chip Serial X2 90 100 110 ma Power Consumption P BL I f =100mA - 990 1080 mw Uniformity (with L/G) - I f =100mA 75%*1 - - Color coordinate (Center point) Luminous color Chip connection X 0.27 0.29 0.33 I f =100mA Y 0.24 0.28 0.33 White 3 chip Serial X 2 connection Bare LED measure position: A 5/6 A 1/6 B 1/2 A 1/6 A 1 2 3 B 5/6 B 1/2 B 4 5 6 7 8 9 Light source (MAIN LCD) Min( P1 ~ P9) *1 Uniformity (LT): 100 80% Max( P1 ~ P9) Date : 2012/01/10 AMPIRE CO., LTD. 5
5 Optical characteristics Main LCD 5.1 Optical characteristics (1/800 Duty in case except as specified elsewhere Ta = 25 C) LED backlight transmissive module: Item Symbol Temp. Min. Std. Max. Unit Conditions Response Tr + Tf 25 o θ=0 o,φ=0 o C -- 25 -- ms time (Note 2) Contrast ratio CR 25 o θ=0 o, φ=0 o LED:ON, LIGHT:OFF C 720 900 - - (Note 4) Transmittance T 25 o C 4.2 4.7 - % Visual angle range front and rear θ 25 o C (θf) 80 (θb) 80 Degree φ= 0 o, CR 10 LED:ON LIGHT:OFF (Note 3) Visual angle range left and right θ 25 o C (θl) 80 (θr) 80 Brightness 25 o C 400 500 600 Degree cd/ m2 Life time 25 o C 30k -- -- Hrs φ=90 o, CR 10 LED:ON LIGHT:OFF (Note 3) V LED =9.9V, 160mA Full White pattern 5.2 CIE (x, y) chromaticity (1/800 Duty Ta = 25 C) Item Red Green Blue White Symbol Transmissive Min. Typ. Max. X 0.632 0.652 0.672 Y 0.310 0.330 0.350 X 0.297 0.317 0.337 Y 0.555 0.575 0.595 X 0.117 0.137 0.157 Y 0.112 0.132 0.152 X 0.291 0.311 0.331 Y 0.321 0.341 0.361 Conditions θ=0,φ=0 θ=0,φ=0 θ=0,φ=0 θ=0,φ=0 Date : 2012/01/10 AMPIRE CO., LTD. 6
NOTE 1: Optical characteristic measurement system Ring light LCD module Brightness gauge BM-7 (Topcon) Glass fiber LED:OFF, LIGHT:ON Metal halide lamp LCD Optical Detector Brightness gauge BM-7 (Topcon) LED LED:ON, LIGHT:OFF NOTE 2: Response tome definition Date : 2012/01/10 AMPIRE CO., LTD. 7
NOTE 3: φ θ definition NOTE 4: Contrast definition NOTE 5: Visual angle direction priority 12 : 00 9 : 00 8 8 8 8 3 : 00 6 : 00 Date : 2012/01/10 AMPIRE CO., LTD. 8
6 Block Diagram Block diagram (Main LCD) Display format: A-Si TFT, Normally Black type(mva). Display composition: 480 x RGB x 800 dots LCD Driver : ILI9803 Back light: White LED x 6 (I LED =100mA) G800 4.3" TFT LCD Panel 480(RGB)X800 pixels G1 S1440 S1 VCOM DC/DC Power Supply Circuit Gate Driver Circuit Driving Circuit ILI9803 LED Driver Vcc 18 VSSD, VSSD2, VSSA MCU 4 R2~R7 B2~B7 G2~G7 VSYNC, HSYNC, DCLK, DE /RESET Vss VLED Date : 2012/01/10 AMPIRE CO., LTD. 9
7. Electrical Specifications 7.1 TFT LCD Panel LVDS Descriptions CN1: Pin No Symbol Function 1 VDD POWER SUPPLY:3.3V 2 VDD POWER SUPPLY:3.3V 3 Gnd Power Ground 4 Gnd Power Ground 5 IN0- Transmission Data of Pixels 6 IN0+ Transmission Data of Pixels 7 Gnd Power Ground 8 IN1- Transmission Data of Pixels 1 9 IN1+ Transmission Data of Pixels 1 10 Gnd Power Ground 11 IN2- Transmission Data of Pixels 2 12 IN2+ Transmission Data of Pixels 2 13 Gnd Power Ground 14 CLK- Sampling Clock 15 CLK+ Sampling Clock 16 Gnd Power Ground 17 ADJ Adjust for LED brightness 18 VLED Power supply for LED: 3.3~5V 19 Gnd Power Ground 20 Gnd Power Ground Note1: The module is with a MCU 48R05. The MCU will send the initial code to ILI9803 when power ON. NOTE : 1. ADJ adjust brightness to control Pin, Pulse duty the bigger the brighter. Date : 2012/01/10 AMPIRE CO., LTD. 10
2. ADJ signal = 0 ~ 5.0V, operation frequency : 100Hz~100KHz 3. VSS Pin must ground contact, can not be floating. Date : 2012/01/10 AMPIRE CO., LTD. 11
7.2 Instruction List Date : 2012/01/10 AMPIRE CO., LTD. 12
Date : 2012/01/10 AMPIRE CO., LTD. 13
Date : 2012/01/10 AMPIRE CO., LTD. 14
Date : 2012/01/10 AMPIRE CO., LTD. 15
Date : 2012/01/10 AMPIRE CO., LTD. 16
8. Application 8.1 Display ON Date : 2012/01/10 AMPIRE CO., LTD. 17
8.2 Display OFF Date : 2012/01/10 AMPIRE CO., LTD. 18
8.3 Standby Mode Date : 2012/01/10 AMPIRE CO., LTD. 19
9. Electrical Characteristics 9.1 AC Characteristics ( RGB Interface Timing Characteristics ) Date : 2012/01/10 AMPIRE CO., LTD. 20
Date : 2012/01/10 AMPIRE CO., LTD. 21
The timing chart of 18-16-bit RGB interface mode is shown as below RGB Interface default: VSPL= 0, HSPL= 0, DPL= 0 and EPL= 1 of Interface Mode Control (B0h) command. Date : 2012/01/10 AMPIRE CO., LTD. 22
Date : 2012/01/10 AMPIRE CO., LTD. 23
Date : 2012/01/10 AMPIRE CO., LTD. 24
10.QUALITY AND RELIABILITY 10.1 TEST CONDITIONS Tests should be conducted under the following conditions : Ambient temperature : 25 5 C Humidity : 60 25% RH. 10.2 SAMPLING PLAN Sampling method shall be in accordance with MIL-STD-105E, level II, normal single sampling plan. 10.3 ACCEPTABLE QUALITY LEVEL A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 10.4 APPEARANCE An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under florescent light. The inspection area of LCD panel shall be within the range of following limits. Date : 2012/01/10 AMPIRE CO., LTD. 25
11.5 INSPECTION QUALITY CRITERIA No. Item Criterion for defects Class of Defec Accept able level 1 Non display No non display is allowed Major 0.65 2 Scratch,Dent Plastic Mold of Serious one is not allowed Major 0.65 3 Scratch on FPC By limited sample Major 0.65 4 Dot Defect Minor 1.5 5 Line Defect None Minor 1.5 6 7 Uneven Brightness : Line Shape None Major 0.65 Uneven Brightness : Dot Shape None Major 0.65 8 Display pattern Unit:mm A B D E 0.30 0 < C 0.25 2 2 F G 0.25 2 Note: 1. Acceptable up to 3 damages 2. NG if there re to two or more pinholes per dot Minor 1.5 9 Scratch of Polarizer :Dot Shape s Size: A B D 2 Size D (mm) D < 0.1 0.1 < D < 0.3 0.3 < D Acceptable number Ignore 3 0 Minor 1.5 Date : 2012/01/10 AMPIRE CO., LTD. 26
Scratch of Polarizer : Width (mm) Length (mm) Acceptable number W<0.05 L < 0.3 Ignore 10 Line Shape 0.1<W<0.05 0.3 < L < 2.0 Minor 1.5 0.1<W - See dot shape 11 Bubble in polarizer Size D (mm) D < 0.3 0.30 < D < 0.50 0.50 < D Acceptable number Ignore 1 0 Minor 1.5 12 Stains inclusion : Line shape Width (mm) Length (mm) Acceptable number W<0.04 0.04<W<0.06 0.06<W Ignore L < 0.8 - Not Allowed Not Allowed Not Allowed Minor 1.5 13 Stains inclusion : dot shape Size D (mm) D < 0.1 0.1 < D < 0.2 0.25< D Acceptable number Not Allowed Not Allowed Not Allowed Minor 1.5 Date : 2012/01/10 AMPIRE CO., LTD. 27
11.6 RELIABILITY Test Item Test Conditions Note High Temperature Operation Low Temperature Operation 70 3 C, t=72 hrs -20 3 C, t=72 hrs High Temperature Storage 80 3 C, t=72hrs 1,2 Low Temperature Storage -30 3 C, t=72 hrs 1,2 Humidity Test 40 C, Humidity 90%, 72 hrs 1,2 Thermal Shock Test -30 C ~ 25 C ~ 80 C 30 min. 5 min. 30 min. ( 1 cycle ) Total 5 cycle Sweep frequency:10~55~10 Hz/1min Vibration Test (Packing) Amplitude : 0.75mm Test direction : X.Y.Z/3 axis Duration : 30min/each axis 150pF 330 ohm +8kV, 10times air discharge Static Electricity +5kV, 10times contact discharge Note 1 : Condensation of water is not permitted on the module. Note 2 : The module should be inspected after 1 hour storage in normal conditions (15-35 C, 45-65%RH). Definitions of life end point : Current drain should be smaller than the specific value. Function of the module should be maintained. Appearance and display quality should not have degraded noticeably. Contrast ratio should be greater than 50% of the initial value. 1,2 2 Date : 2012/01/10 AMPIRE CO., LTD. 28
12 USE PRECAUTIONS 12.1 Handling precautions 1) The polarizing plate may break easily so be careful when handling it. Do not touch, press or rub it with a hard-material tool like tweezers. 2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If the surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or chamois leather in benzine and wipe off with it. Do not use chemical liquids such as acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction phenomena and deteriorations. 3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform or decolorize. 4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck on your skin or clothing, wash thoroughly with soap and water immediately. 12.2 Installing precautions 1) The PCB has many ICs that may be damaged easily by static electricity. To prevent breaking by static electricity from the human body and clothing, earth the human body properly using the high resistance and discharge static electricity during the operation. In this case, however, the resistance value should be approx. 1MΩ and the resistance should be placed near the human body rather than the ground surface. When the indoor space is dry, static electricity may occur easily so be careful. We recommend the indoor space should be kept with humidity of 60% or more. When a soldering iron or other similar tool is used for assembly, be sure to earth it. 2) When installing the module and ICs, do not bend or twist them. Failure to do so may crack LC element and cause circuit failure. 3) To protect LC element, especially polarizing plate, use a transparent protective plate (e.g., acrylic plate, glass etc) for the product case. 4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing plate) and product case stick together. Failure to do so may cause the polarizing plate to peel off. Date : 2012/01/10 AMPIRE CO., LTD. 29
12.3 Storage precautions 1) Avoid a high temperature and humidity area. Keep the temperature between 0 C and 35 C and also the humidity under 60%. 2) Choose the dark spaces where the product is not exposed to direct sunlight or fluorescent light. 3) Store the products as they are put in the boxes provided from us or in the same conditions as we recommend. 12.4 Operating precautions 1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs. When applying power voltage, check the electrical features beforehand and be careful. Always turn off the power to the LC module controller before removing or inserting the LC module input connector. If the input connector is removed or inserted while the power is turned on, the LC module internal circuit may break. 2) The display response may be late if the operating temperature is under the normal standard, and the display may be out of order if it is above the normal standard. But this is not a failure; this will be restored if it is within the normal standard. 3) The LCD contrast varies depending on the visual angle, ambient temperature, power voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage. 4) When carrying out the test, do not take the module out of the low-temperature space suddenly. Failure to do so will cause the module condensing, leading to malfunctions. 5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less and H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond the standard, the module may often malfunction. In addition, always connect the module when making noise level measurements. 6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is not adopted for the input so avoid putting the input signal open while the power is ON. Date : 2012/01/10 AMPIRE CO., LTD. 30
7) The characteristic of the semiconductor element changes when it is exposed to light emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To prevent these malfunctions, design and assemble ICs so that they are shielded from light emissions. 8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs when the regularized display is maintained. Also, crosstalk is affected by the LC drive voltage. Design the contents of the display, considering crosstalk. 12.5 Other 1) Do not disassemble or take the LC module into pieces. The LC modules once disassembled or taken into pieces are not the guarantee articles. 2) The residual image may exist if the same display pattern is shown for hours. This residual image, however, disappears when another display pattern is shown or the drive is interrupted and left for a while. But this is not a problem on reliability. 3) AMIPRE will provide one year warrantee for all products and three months warrantee for all repairing products. Date : 2012/01/10 AMPIRE CO., LTD. 31
13. MECHANIC DRAWING Date : 2012/01/10 AMPIRE CO., LTD. 32