Light wear for a powerful hearing. Bone Conduction Headset



Similar documents
SEMI-IMPLANTABLE AND FULLY IMPLANTABLE MIDDLE EAR HEARING AIDS

A diagram of the ear s structure. The outer ear includes the portion of the ear that we see the pinna/auricle and the ear canal.

Surgery for Conductive Hearing Loss

Your Hearing ILLUMINATED

BONE-CONDUCTION HEARING AIDS

AP Psychology ~ Ms. Justice

Lecture 4: Jan 12, 2005

CONVENTIONAL AND DIGITAL HEARING AIDS

So, how do we hear? outer middle ear inner ear

Dr. Abdel Aziz Hussein Lecturer of Physiology Mansoura Faculty of Medicine

Hearcentres Guide to Hearing Aid Terminology

Hearing Aids. What Is a Hearing Aid? How Common Is Hearing Loss and What Causes It? How Do We Hear?

What are the causes of presbycusis? What can be done? How can I communicate with someone who has a hearing loss? How does hearing work?

Veterans UK Leaflet 10. Notes about War Pension claims for deafness

Pure Tone Hearing Screening in Schools: Revised Notes on Main Video. IMPORTANT: A hearing screening does not diagnose a hearing loss.

Diseases of the middle ear

Understanding Hearing Loss

Sound Perception. Sensitivity to Sound. Sensitivity to Sound 1/9/11. Not physically sensitive to all possible sound frequencies Range

Hearing and Deafness 1. Anatomy & physiology

Audiology Services. Carolyn Dando Audiology Services Manager South Warwickshire NHS

Byron's Hudson Valley Hearing Aid Centers Kingston/Lake Katrine Poughkeepsie Your hearing Journey

Anatomy and Physiology of Hearing (added 09/06)

Presbycusis. What is presbycusis? What are the symptoms of presbycusis?

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

Noise: Impact on Hearing; Regulation

The Design and Implementation of Multimedia Software

Noise. CIH Review PDC March 2012

Middle ear conditions

Guideline for Hearing Conservation and Noise Control

Getting Started Kei Te Timata

Vibrant Soundbridge Implantable Hearing System

Implantable Bone Conduction Clinical Coverage Policy No: 1A-36 Hearing Aids (BAHA) Amended Date: October 1, 2015.

Hearing Conservation Procedures

Ear Disorders and Problems

PURE TONE AUDIOMETRY Andrew P. McGrath, AuD

PROTECT YOUR HEARING

Noise and Hearing Protection

Cochlear Implants: A Communication Choice. Cochlear Implants: A Communication Tool.

NIHL - understanding audiograms and medical causation

S-822. Noise and Hearing Conservation RISK MANAGEMENT

Getting a Cochlear Implant

- Review ear anatomy. Evaluation of Hearing. - Specific causes of hearing loss

5th Congress of Alps-Adria Acoustics Association NOISE-INDUCED HEARING LOSS

Hearing Tests And Your Child

Learners Who are Deaf or Hard of Hearing Kalie Carlisle, Lauren Nash, and Allison Gallahan

NEW YORK STATE MEDICAID PROGRAM HEARING AID/ AUDIOLOGY SERVICES PROCEDURE CODES

X-Plain Perforated Ear Drum Reference Summary

Section 4. Hearing loss and hearing tests

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

Chapter 8. Hearing and Ear Abnormalities in Fanconi Anemia. Introduction. Anatomy and Function of the Ear

USER GUIDE. Thank you for choosing Ovation Hearing and congratulations on taking control of your hearing health.

Help maintain homeostasis by capturing stimuli from the external environment and relaying them to the brain for processing.

Hearing Aids - Adult HEARING AIDS - ADULT HS-159. Policy Number: HS-159. Original Effective Date: 3/18/2010. Revised Date(s): 3/18/2011; 3/1/2012

HEARING. With Your Brain

Generic - Hearing Loop - (AFILS) U.S. System Specification

Clinical Commissioning Policy: Bone Anchored Hearing Aids. April Reference: NHSCB/ D09/P/a

Once your baby has good head control and can turn towards something interesting, a more advanced behavioural procedure can be used.

Section 4. Hearing Protection and Hearing Conservation Program (WAC ), Noise Level Survey

HEARING SCREENING (May 2006)

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

USER GUIDE PREFIX PREMIUM BLEND

Occupational Noise Exposure Requirements

Auditory System. Chaos Healthcare

Hearing Aid Styles. Siemens Phonak Widex Starkey. Sonic Oticon Unitron. Resound

Occupational Noise Induced Hearing Loss

8.Audiological Evaluation

Prevalence of otological disorders in diabetic patients with hearing loss

1/26/ % of deafness and hearing impairment is avoidable through prevention, early diagnosis, and management.

Pediatric Hearing Assessment

A Guide to Otoacoustic Emissions (OAEs) for Physicians

Big Data in Education

Hearing Tests And Your Child

A Hearing Aid Primer

On frequency characteristics of bone conduction actuators by measuring loudness, acceleration and otoacoustic emission

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Noise at work a guide for health and safety representatives

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Single Transistor FM Transmitter Design

Cochlear Hyperacusis and Vestibular Hyperacusis

The loudness war is fought with (and over) compression

Cochlear Implant, Bone Anchored Hearing Aids, and Auditory Brainstem Implant

STI 9 Edition 2/October 2000

MICROPHONE SPECIFICATIONS EXPLAINED

Middle Ear Implants for the Treatment of Hearing Loss

GONCA SENNAROĞLU PhD LEVENT SENNAROĞLU MD. Department of Otolaryngology Hacettepe University ANKARA, TURKEY

Generating Element. Frequency Response. Polar Pattern. Impedance. Output Level

Tonal Detection in Noise: An Auditory Neuroscience Insight

OPERATING INSTRUCTIONS

Noice induced hearing loss, Ototoxic drugs, Meniers disease, Rotataory vertigo, Sensorineural hearing loss, Tinnitis, Infections, Acoustic neuroma,

Bone Anchored Hearing Aids B.A.H.A

Transcription:

Light wear for a powerful hearing Bone Conduction Headset

2

Light wear for a powerful hearing Melody Flex, the new bone conduction headset is AUTEL s solution to improve hearing quality of those affected by hearing loss treatable by bone conduction. Melody Flex can be applied especially to those who suffer from hearing impairment due to physical deformities that limit the application of other hearing aids. Melody Flex is a form of alternative conduction to the bone conduction spectacles. It is highly suited to those affected by hearing loss who seek an effective solution, that is also discreet and elegant. 1

Light, discreet and elegant Melody Flex has been designed with materials that have been chosen in order to obtain an object which is light to wear and has a refined design so to offer a comfortable and pleasant use. Melody Flex wants to give those who wear it a feeling of comfort and confidence. Sound Performance The new Autel bone conduction headset is provided with Autel Flex technology and an innovative telescopic system, that together guarantee: Simplicity in the fitting of the aid without having to resort to surgery or to substituting parts Elevated flexibility for a complete adaptability to the patient Highest bone conduction adherence to the mastoid area 2

Melody Flex / 3

All shapes in a few simple actions Melody Flex is thought to make the professional s fitting of the aid easy and to ensure a perfect adherence of the hearing aid to any physiognomy. Thanks to the several joining and bending points together with Autel Flex system the aid guarantees the highest adherence of the bone conductor to the patient s mastoid area. 4

A telescopic system and 4 joining points for a complete adaptability to any patient Thanks to its 4 mechanical joining points together with the telescopic system, Melody Flex ensures a complete adaptability to any physiognomy. The fitting telescopic system is simple and it permits an easy positioning of the conductor on the mastoid area. The aid can be adapted to the right size by adjusting a single screw on its back side. From the band to the bone conductor: a perfect adherence for a superior performance The high flexibility of the entire structure permits remarkable pliancy. The necessary reshaping can be applied both to the headset and to the bone conductor. Thanks to Autel Flex technology, the terminal can be rotated in any position so to reach the maximum adherence to the mastoid area and therefore obtaining the best sound performance. 5

Flexible Autel Flex technology is a revolutionary innovation in the world of bone conduction hearing aids. With Autel Flex system the fitting of the hearing aid becomes faster and more efficient thanks to the cold shaping process. This process, in comparison to the traditional hot methods, permits the audiologists to achieve sooner and in an easier way an absolutely precise setting of the bone conduction on the patient s mastoid area. Simple and performing The performance is improved through the innovative cold shaping method that allows the expert to perform a more precise fitting operation of the bone conductor to the mastoid compared to the traditional methods. This means obtaining results that are clearly better both in the adherence and consequently in the aid s sound output. 6

Powerful POWER technology is a stronger version of the hearing aid s bone conductor. Thanks to this technology the field of hearing loss types treatable with Melody Flex bone conduction headset is widened, providing the audiologists with a modern instrument more and more precise in the treatment of these kind of pathologies. Fitting range comparison Melody Flex Melody Flex Power 7

Auditory system The auditory system receives and converts air pressure changes induced by the passage of a sound wave and transmits it to the auditory system through three constituent parts: the outer ear, middle ear and inner ear. The external auditory meatus (EAM) has the task of amplifying the sounds in the frequencies ranging between 2 and 4 khz, improving the discrimination of speech in noisy environments present on low frequencies. The EAM also plays a protective role with regards to the tympanic membrane (eardrum) defending it from external mechanical and traumatic agents. The inner ear is composed of the cochlea and labyrinth. The cochlea is a spiral-shaped cavity containing liquid, with hair cells and is designed to encode mechanical wave signals as auditory nerve impulses. 8

The labyrinth specializes in capturing the smallest differences in posture that help to keep our body in perfect balance. The middle ear is found between the outer and inner ear. The outer ear is separated from the EAM by the tympanic membrane. Accommodated in the cavity there are three tiny bones known as the ossicles: hammer, anvil and stirrup, which constitute, together, the ossicular chain. The tympanum-ossicular system allows the transmission of sound from the EAM to the cochlea, acting as a transformer, joining two sources, air and liquid, with different impedance limiting the dispersion problem. The tympanum-ossicular system also works as a phase differentiator between sound waves reaching the oval cavity and those reaching the round cavity. Different types of hearing loss We can distinguish different types of hearing loss which result from damage to one or more parts of the ear: - Sensorineural hearing loss due to problems related to the cochlea and auditory nerve - Mixed hearing loss caused by the combination of transmission and neurosensory factors - Conductive hearing loss We define conductive or transmission hearing loss as that occurring when the sound stimulus cannot reach the auditory cells for purely mechanical reasons, caused by: - Otosclerosis - After radical surgery to the middle ear - Chronic otitis - For infectious or inflammatory processes of the outer ear - In the presence of dermatitis - In the event of a perforated eardrum - Malformation of the ear The amount of hearing loss due to a conductive problem may not exceed 70 db. 9

How does the bone conduction hearing aid work A bone conduction hearing aid allows the patient to hear skipping the middle and the external areas of the ear. The microphone captures the sound, the internal circuit amplifies it and the bone conductor transforms it into mechanical vibrations. The vibrations are then sent to the mastoid bone and consequently to the internal area of the ear where they are transformed into nervous impulses, perceived by the brain as sounds. The bone conduction hearing aid represents an effective treatment for a number of hearing loss cases due to: Chronic otitis Radical middle ear surgery Chronic middle ear infection Ear inflammation/external ear infection Dermatitis Eardrum perforation Bone conduction application cases Melody Flex Melody Flex Power 10

The open ear system option as an alternative to ear canal obstrucion The application of an open ear hearing aid avoids several annoyances, such as obstruction, even partial, of the external ear canal, which may cause dissatisfaction for many reasons, such as: Variation of ear s natural acoustics, which is the source of acoustic information and sound stimulation (in the 2-3 khz sound band) Excessive amplification of the low frequencies resulting in a feeling of rumble and loss of higher frequencies Autophony phenomenon: altered hearing of one s own voice The application of bone conduction hearing aid is an effective alternative to implantable hearing aid The surgical solution is invasive, expensive and has an impact from an aesthetic point of view and it is also not reversible. Bone application Semi-implantable application Sound quality Appearance Non obstructive Non invasive Price 11

12 / Melody Flex

Comfortable and elegant Autel pays great attention to the design of its hearing aids. Melody Flex, just as all Autel products, is inspired by the traditional excellence of the Made in Italy. It pays attention to every small detail and to the materials so to obtain the highest balance between sound performance and style. 13

Personalise it with various colour combinations With Melody Flex one can personalise the combinations choosing various colour options for the headset s cover and both the hearing aid and bone conductor. 14

Headset s cover Hearing aid Bone conductor Discover all the possible cromatic variations For the complete catalogue of all the colour variation available for the headset and for the hearing aid please visit the Melody Flex page on our website www.autel-italia.it 15

Technical Specification DGT 3 DGT 4 DSP 1/M DSP 4/M Trimmer 3 4 no no Low tone control yes yes yes yes High tone control no yes yes yes Gain control yes yes yes yes Volume control yes yes yes yes Power control yes yes yes yes M-T switch yes yes yes yes High GSM immune microphone yes yes yes yes Acoustic warning for low battery yes yes yes yes DGT DSP Digital programmable with trimmers Digital programmable using AUTEL software Melody Flex Melody Flex Power Output force level max Peak 1.600 Hz Mechanical-acoustic sensitivity level (AMSL) Peak 1.600 Hz Mechanical-acoustic sensitivity level (RTG) Frequency range Equivalent input noise level Maximum coil sensitivity (10mA/m) THD Total harmonic distortion ( 500 / 800 / 1600 Hz ) Battery current Battery type (Zinc-air) Average battery life Reference test frequency 108 db rel.1μ N 96 db rel.1μ N 37 db 26 db 21 db 250 Hz 5000 Hz 28 db rel.1μ N 67 db rel.1μ N < 2,5 / 0,2 / 0,1 % < 1,6 ma 675 @ 310 h 1600 Hz 115 db rel.1μ N 103 db rel.1μ N 48 db 35 db 30 db 250 Hz 4500 Hz 35 db rel.1μ N 79 db rel.1μ N < 2,5 / 0,2 / 0,1 % < 1,5 ma 675 @ 310 h 1600 Hz 16 Specifications AODN003 - REV 6

Fitting Range Melody Flex Melody Flex Power Melody Flex db rel.1µn OFL90 Input 90 dbspl db AMSL Input 60 dbspl db AMSL RTG 120 60 40 Input 60 dbspl 100 40 20 80 20 0 60 0-20 40-20 -40 KHz 0.1 0.5 1 2 5 10 KHz 0.1 0.5 1 2 5 10 KHz 0.1 0.5 1 2 5 10 Melody Flex Power db rel.1µn OFL90 Input 90 dbspl 140 db AMSL Input 60 dbspl db AMSL RTG 60 60 Input 60 dbspl 120 40 40 100 20 20 80 0 0 60-20 -20 KHz 0.1 0.5 1 2 5 10 KHz 0.1 0.5 1 2 5 10 KHz 0.1 0.5 1 2 5 10 MEASURING CONDITIONS Individual patient results may vary. CEI 29-13 (IEC118-9) Artificial mastoid type: B&K 4930 Environmental conditions: T = 23 +/- 5 RH.= 40-80% PA = 101,3 kpa Operating voltage: 1,3 Volts Tolerances: +/- 4 db up to 2kHz +/- 6 db up to 4kHz AODN003 - REV 6 Specifications 17

Design: amarantoweb.com Melody Flex is a product of Autel S.r.l. Via Taormina, 1-00041 Pavona (Rome) - Italy Ph. +39 06 93 111 31 Fax +39 06 93 100 76 info@autel-italia.it www.autel-italia.it This publication is intended for experts in the field only. 2014 Autel Srl. All rights reserved. Features, design and specifications are subject to change without notice. For updates 18 please view www.autel-italia.it REV 2-2014