Tobii TX 300. Experiment Room. Participant



Similar documents
Eye Tracking Instructions

Lab Activity on Air Pressure, Wind and Air Circulation Caused by Heating of the Atmosphere

Eye-tracking. Benjamin Noël

Standards A complete list of the standards covered by this lesson is included in the Appendix at the end of the lesson.

Cerebral Palsy and Visual Impairment

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Eye Tracking System Instruction. Manual. Model Mobile Head Mounted Optics with Mobile Electronics Package (Addendum to Model 501 manual)

Lessons 1-15: Science in the First Day of the Creation Week. Lesson 1: Let There Be Light!

EMR-9 Quick Start Guide (00175)D 1

Tobii 50 Series. Product Description. Tobii 1750 Eye Tracker Tobii 2150 Eye Tracker Tobii x50 Eye Tracker

3D GLASSES FOR SHARP 3D AQUOS OPERATION MANUAL

Nokia Bluetooth Headset BH-200 User Guide

Display screen equipment (DSE) workstation checklist

The Eyegaze Edge : How does it work? What do you need to know?

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

myvisiontrack Cleared User s Manual Ophthalmic Medical Device Caution: Federal Law restricts this device to sale by or on order

Videoconferencing Room Guide

Electronics and Soldering Notes

Your EdVenture into Robotics You re a Controller

Making natural looking Volumetric Clouds In Blender 2.48a

Digital Image Requirements for New Online US Visa Application

Worksheets for Teachers. The Lowry

Advanced MakeUp Tips by Kathy Whittington

Protocol for Microscope Calibration

Care and Handling of Your VAIO Computer

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

Requirement of Photograph for Indian Passport

Filters for Black & White Photography

Photovoltaic Cell: Converting Light to Electricity

Video Baby Monitor System. User Guide

Care and Use of the Compound Microscope

The light. Light (normally spreads out straight and into all directions. Refraction of light

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection

How to Record Videos with a Webcam

Nokia Bluetooth Headset BH-800 User Guide Issue 2

Conference Room Environmental Conditions :

Kindergarten Number Sense Lesson Plan

7tipsforsofter. lookinglight. Beginners Digital Photography - Tutorial 03. Making Photography Easier. www. DIGITAL Beginners.com

Eye Injuries. The Eyes The eyes are sophisticated organs. They collect light and focus it on the back of the eye, allowing us to see.

Calibrating your monitor

The Lighting Effects Filter

Advanced Programming with LEGO NXT MindStorms

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Earth, Sun and Moon is a set of interactives designed to support the teaching of the QCA primary science scheme of work 5e - 'Earth, Sun and Moon'.

Camtasia Studio 8.4 Create Engaging Screencasts

Understanding posterior vitreous detachment

Understanding Depth Of Field, Aperture, and Shutter Speed Supplement to Mastering the Nikon D7000

ATS Control Panel. User s Manual

Agility Training for 4-H Dog Club (Page 1 of 5

EEG Cap Instructions

Written By: Walter Galan

1. Three-Color Light. Introduction to Three-Color Light. Chapter 1. Adding Color Pigments. Difference Between Pigments and Light. Adding Color Light

Blender 2.49b How to generate 3D-images?

ENGLISH. Lightphoria 10,000LUX Energy Light Lamp SP9982 version 2.4

Theremino System Theremino Spectrometer Technology

Phases of the Moon. Preliminaries:

Eye-Tracking Methodology and Applications in Consumer Research 1

Changing the Receiver Volume (receiver - the voice you hear)

OPERATION MANUAL. IWB Setup Software/EyeRIS NEC edition

600 Series Camera. User Guide

Vestibular Assessment

There may be no symptoms at first. Eye problems can. You can help prevent eye problems. Just because you have

SMA Solar Technology AG Solar is Future for Kids. Solar power

UNIT 1 GCSE PHYSICS Infrared Radiation 2011 FXA

Video-Based Eye Tracking

Lenses and Telescopes

PeopleGIS Leica RTK GPS Instructions

Why is lighting in the workplace important?

Plant In a Cup. When considering what to do for our curriculum project, our main goal was

Wireless Audio Video Sender

Used to join the withies together. Don t use low tac tape, it s not strong enough! Tear or cut strips ready for use.

understanding sensors

5. Tutorial. Starting FlashCut CNC

Chapter 22: Mirrors and Lenses

OptimizedIR in Axis cameras

Writing a Scholarship Essay. Making the essay work for you!

CREATING SCENERY WITH THE PHOENIX RC CREATOR PROGRAM

FREQUENTLY ASKED QUESTIONS

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

Solving the Rubik's Revenge (4x4x4) Home Pre-Solution Stuff Step 1 Step 2 Step 3 Solution Moves Lists

Light in the Greenhouse: How Much is Enough?

Alignement of a ring cavity laser

STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves

Color Filters and Light

In most cases problem images are caused by the environment. Here are some of the most common issues:

How to care for your eye after surgery

-ipad 2: Quick Reference Guide-

VISM Evolution Scope Series

Designing eye tracking experiments to measure human behavior

Second, advertise the event and make sure students bring a friend, wear dark clothes and bring a mini flashlight.

Laser Cutter User Manual

Exploring the Phases of the Moon

Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014)

and satellite image download with the USGS GloVis portal

Written By: Walter Galan

To explain the basics of how lasers work and let visitors experiment with laser properties.

CS Digital Microscope User Manual

Transcription:

Tobii TX 300 Tobii TX 300 is an eyetracker that has a high speed infrared camera and it emits infrared light.it can track eyedata at 60Hz, 120Hz or 300Hz. It chooses automatically between black pupil eye tracking and white pupil eyetracking. It prefers black pupil eyetracking. In black pupil eyetracking the biggest black things the camera sees are supposed to be the pupils. In infrared light, eye makeup looks darker and bigger than the pupils. Eyemakeup should in all cases be removed by using a proper eyemakeup remover and eyepads. NEVER ever use ALCOHOL to clean eyes. This can cause BLINDNESS. White pupil eyetracking uses more infrared lighting, that is reflected in the eye (red eye effect) to find the pupils. Since there is more infrared light shining into the eyes, the eyes might get a bit dry if this method is used for a longer period. Both methods use reflection of infrared light in the eyeball, the position of the pupils and a calibration to determine where the subject is looking. Experiment Room Tobii uses an infrared camera that is located underneath the computerscreen. The infrared emitters are also located underneath the screen. It is important that there are no infrared sources or reflections shining into the camera. Turn off incandescent light bulbs (gloeilampen), including Christmas lighting. The fluorescent (TL-lampen) are fine. Avoid sunlight shining into the room.changes in sunlight intensity (clouds) cause changes in pupil diameters, that can cause trouble in tracking the eyes. Sunlight is also a source of infrared light, sunlight must not shine into the cameras. Avoid that infra red light coming from the Tobii unit is reflected back to the Tobii camera. Participant The participant cannot wear any eyemakeup. Tobii will see mascara as the biggest black thing it can find. But it should find the pupil. Eyemakeup must be completely removed. It should be removed by using eyepads and proper cleaning liquid. Ask the ladies what they use Afterwards, clean with eyepad and water. Then, dry with a dry eyepad. NEVER use ALCOHOL to clean. This can cause BLINDNESS. The eyes must be seen by the cameras. Hair in front of the eyes can block camerasight on the eyes. Hair can be removed from sight by using (non-reflective) hairclips. Try to avoid glasses, jewelry, metallic hairclips and anything else that can cause infrared reflections. Remove oily/reflecting patches around the eyes; such as at the tearducts, on the eyelids and underneath the eyes. This can be done with a tissue or with an eyepad. These areas can also reflect infrared light back to the Tobii. Use proper cleaning liquid or water. After cleaning, dry with a dry eyepad. NEVER use ALCOHOL to clean. This can cause BLINDNESS.

Startup Procedure Begin with switching on the Tobii eyetracker and the Tobii screen and wait for the beep that the Tobii makes. Then switch on the other computers. This is to prevent the other computers to turn off the external display: the Tobii screen. After the computers have started up, wait until all network lights on the network device that have cables connected are on. This is to ensure that network communication is working. If the leds don t go on, wait a little bit more. If the leds are not on within 5 minutes, contact TSG for further assistance. Then startup Tobii Studio and open your experiment file, if you already have one. Otherwise, startup Tobii Studio and continue reading the section Settingup an Experiment using Tobii Studio. Setting up an experiment using Tobii Studio Installing a participant It is important to have a good measurement, without a lot of missing samples. Therefore it is important that there are no infrared reflections into the Tobii camera and that the participant is not wearing eyemakeup. (see section Participant). Also, it is important that the participant is comfortable during the experiment. Tobii allows a little bit of movement of the participants head, but movements are limited. If the participant is sitting comfortable, head movements are more likely to be within the range that Tobii allows. The participant should be sitting in a comfortable position before the calibration is done and should stay in that same position during the experiment. Calibration A good eyetracking measurement relies on a good calibration. And a calibration that stays good during the experiment. Factors that disturb the calibration during the experiment include: The participant moves too much, or changes position. Therefore it is important that the participant is sitting in a comfortable position that can be persevered during the whole experiment and is instructed to look at the screen in a natural way, without moving too much. Big changes in pupil size. Try to keep pupil size more or less the same during the experiment. That will result in a better measurement. To do this, avoid big changes in luminance. Sunshine in the room will change pupil size during the experiment if the sun is sometimes blocked by clouds or is shining bright. Avoid sunlight. Luminance of the screen can also influence pupil size. Try to keep luminance of stimuli more or less the same and try to have luminance of the screen during calibration more or less the same as during the experiment. Don t use a white background (small pupils) during calibration when your stimuli are mainly dark. Don t use a black background (large pupils) during calibration when your stimuli are mainly bright. Try to give the backgroundcolor during calibration the same luminance as the screen has during the experiment. When not sure, choose a middle luminant grey as a background.

The participant moves out of the bounding box that Tobii allows. Tobii allows a certain range in distance between the eyes of the participant and the camera. Typically the range is from 55 to 70 centimeters. Too close or too far away from the camera will result in bad or no measurement. Best is to have the participant in a comfortable position, using the back support of the chair at a distance of about 65 centimeters. This will allow the participant to move a little bit forward and a little bit backward during the experiment, without effecting the ability of Tobii to keep track of the eyes. The participant being comfortable is important! It is better to move the Tobii closer or further away than having the participants moving too much, because their postion is not comfortable! Tobii tracks another pair of eyes. Make sure that only the participants eyes are visible in the Tobii camera. Don t look over the participants shoulder to explain the experiment. If more than one pair of eyes is visible in the eyetrackers camera, it might lose track of the participants eyes and switch to the other pair of eyes. The calibration procedure is started at the beginning of the recording. Press the red Record button and make sure that is checked. Once the participant is seated in a comfortable position, a quick explanation about what will happen on the screen is sufficient to have the participant look at the dots that are presented on screen. The participant will look at the dots in a natural way, by moving the eyes and moving the head a little bit, in the same way that the participant will look at the stimuli. It is important that the participant looks in a natural and comfortable way, and in the same way during callibration and during the experiment. Just before the calibration is started, Tobii Studio will present a display with a distance measure and two dots that represent the eyes. Make sure that the distance is within the green area, and that during movements, the participants distance stays within the green area. In the figure below, the participant was sitting in a chair close to a table. Therefore it was more likely that movements were going to be towards the eyetracker than away from the eyetracker, so the Tobii was placed at a distance that allowed more freedom of movement towards the eyetracker than away from the eyetracker. If the participant is sitting comfortable and doesn t move to much, adjust the distance by placing the eyetracker closer or turther away from the participant. The dots represent what Tobii sees as the eyes of the participant. Make sure that the dots are in the middle of the display. This can be done by placing the eyetracker more to the left or more to the right and by tilting the eyetracker if the dots should be lower or higher on the display. Use both hands, one on the top of the eyetracker and one at the bottom, and tilt the eyetracker so that the dots appear in the middle of the display. When distance is within the green area and is likely to stay in that area during the recording and the eyes are in the middle of the display, press the Start button to start the calibration.

When the calibration procedure has finished, Tobii Studio will present a feedback screen that contains lines, starting at the dot that was presented and was supposed to be the point of gaze, and ending at the point of gaze that was measured. A very good calibration shows short lines, indicating that the supposed point of gaze is very near to the measured point of gaze. The longer the lines are, the more offset there is between te supposed point of gaze and the measured point of gaze. When the lines at a supposed point of gaze are more pointing towards different directions, there is more noise in the calibration and also in the measurement. How valid or usefull the actual calibration is, depends on the position on screen of the calibration points and the position of your stimuli and it depends on the size of your areas of interest.

Typically, the bottom of the screen has worse calibration. That is caused by the eyelids, partially covering the pupil when the participant looks down. Therefore, it is advised not to use the lower 5 centimeters of the screen for presenting stimuli. Usefullness can be checked by using the Validation procedure. The feedback screen can show a square around a presented dot. That means that there was no data for that point. When there are one or more squares, or if the validation shows that the calibration is not good enough, something should be done to make the calibration better. Check the bulletlist above. Tobii can ask to recalibrate one point, but it is advised to do something (such as remove more mascara, reseat the participant, make sure there is no hair blocking the camera s view on the eyes, ) to make the calibration better. That will invalidate all calibrated points, so the calibration procedure must be totally redone. Validation The validation procedure is used to check how good the calibration was and to check whether use of contactlenses disturbs the tracking of the eye. Tobii Studio will present a grid of dots. Ask the participant to look at the dots and Tobii Studio will present a circle indicating where Tobii Studio thinks the participant is looking at. In a very good calibration, the circle is exactly around the dot. In most calibrations, the circle is very well near the spot. In bad calibrations there is a bigger difference between the location of the circle and the position of the dot. It depends on the location of the stimuli, the size of the areas of interest whether a calibration can be accepted or not. To check the influence of contact lenses, the participant should make a large saccade. Ask the participant to look at the lowerleft dot. Then, ask the participant to look at the upperright spot. This will ensure that the participant makes a big saccade. See how the circle settles around the dot. If it overshoots and then slowly settles towards the spot, there is an influence of contactlenses. This overshooting will occur after every saccade.