DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Similar documents
Overview of types. Technical data

Type overview. Technical data

Products no longer available

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

2- and 3-port valves with flanged connections, PN 10

Butterfly Valves PN 6/10/16 for flanged connection

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Mikrotherm. Manual radiator valves. To be precise.

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic element RAVV for 2-way valves

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

VAD. Variable Area Desuperheaters

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Type 3353 Angle Seat Valve

kymanual or Automatic - it s your Choice

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Self-operated Temperature Regulators Temperature Regulator Type 1u

VAD Variable Area Desuperheaters

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

PRESSURE REDUCING CONTROL VALVE

3/2-way Mini Solenoid Valve

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Thermostatic Actuators

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

SISTO-16TWA/HWA/DLU. Type Series Booklet

HERZ-Thermal Actuators

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

Thermostatic valve Type AVTA

Pressure Independent Control Valves. The Future of Energy Saving

Stainless Steel Single and Dual Circulation Kits

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

2/2 and 3/2 Way Size 6 Seat Valves

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Assisted lift operated 2/2-way solenoid valves Type EV250B

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Return line filters. Return line filters

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

4/2-Way Pneumatic Solenoid Valve

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Technical data. Danfoss DHP-A

Instruction Manual Differential Pressure Transmitter

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Typical Aluminum GFM Mass Flow Meter

KEYSTONE. Stainless steel hygienic butterfly valves F250 for imperial tubing F251 for metric tubing

Turbine Flow Sensor Series VTR

SunMaxx Solar Filling Station Operating Instructions

08.08 Vic-Check Valves

Automatic Bypass Control AVDO

POWERS CONTROL RC 195 Single Input Receiver-Controller

MFP14, MFP14S and MFP14SS Automatic Pumps

3/2-way Solenoid Valve, direct-acting, NC or NO

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

How To Use A Flowmeter

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2- and 2/2-way cartridge valve type BVE

Pressure relief valves Size 6

Stainless Steel Valves For the Sanitary Industries

Frequently Asked Questions

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Series description: Wilo-Drain TC 40

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

T U R B I N E G A S M E T E R

STABITHERM INSTALLATION & SERVICE BOOKLET

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Fisher 657 and 667 Diaphragm Actuators

Directional seated valves type VP 1

Hydraulic Control Solutions

Automatic balancing valves ASV

BG or BGE Brake Rectifier

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

4 Posiflow Proportional Solenoid Valves

Data sheet ECC 12 and 22

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

QLM and QLD Series Three-port Control Valves

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

RC 195 Multiple Input Receiver-Controller

Electric Rotary Actuator - On/Off or programmable control actuator

Transcription:

Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating systems air bubble-tight (control path ) Type overview Type k vs [m 3 /h] DN [Inches] p s [kpa] n(gl) 1) R505K 0,25 10 ³/₄ 4140 3,2 >50 R506K 0,4 10 ³/₄ 4140 3,2 >50 R507K 0,63 10 ³/₄ 4140 3,2 >50 R508K 1 10 ³/₄ 4140 3,2 >50 R509 0,63 15 1 4140 3,2 >50 R510 1 15 1 4140 3,2 >50 R511 1,6 15 1 4140 3,2 >50 R512 2,5 15 1 4140 3,2 >50 R513 4 15 1 4140 3,9 >100 R517 4 20 1 ¹/₄ 4140 3,9 >100 R518 6,3 20 1 ¹/₄ 4140 3,9 >100 R522 6,3 25 1 ¹/₂ 4140 3,9 >100 R523 10 25 1 ¹/₂ 4140 3,9 >100 R529 10 32 2 4140 3,9 >100 R531 16 32 2 2760 3,9 >100 R538 16 40 2 ¹/₄ 2760 3,9 >100 R548 25 50 2 ³/₄ 2760 3,9 >100 1) optimized in the opening range S v Technical data Functional data Flow media Cold and hot water, water with max. 50% volume of glycol Temperature of medium +5 C... +110 C 1) (lower or higher temperatures on request) Rated pressure p s see «Type overview» Flow characteristic Control path : equal percentage (to VDI/VDE 2173) n(gl): see «Type overview» ypass : linear, flow rate is 70% of k vs value Rangeability S v See «Type overview» eakage rate Control path : ir bubble-tight (O 1, DIN3230 T3) ypass : pprox. 1...2% of k vs value (in relation to the highest value within the DN (e.g. R513) Pipe connector External thread to ISO 228/1 Differential pressure Δp max Closing pressure Δp s 350 kpa (200 kpa for low-noise operation) 1400 kpa ngle of rotation 90 (Operating range of control path 15... 90, bypass 15... 70 ) Installation position Upright to horizontal (in relation to the stem) aintenance aintenance-free aterials Fitting Forged, nickel-plated brass body Valve cone and stem Stainless steel Stem seal O-Ring, EPD all seat PTFE, O-Ring Viton Characterizing disk TEFZE Dimensions / Weights see «Dimensions and weights», page 3 otorizing see the complete overview of water solutions 1) The allowed media temperature can be limited, depending on the type of actuator. The correct values can be found in the corresponding actuator data sheets. www.belimo.com T5-R5.. Control en v1.2 05.2012 Subject to changes 1 / 3

R5.. Characterized control valves, 3-way, with external thread Safety notes Product features Installation notes! ode of operation Flow characteristic The valve has been designed for use in stationary heating, ventilation and air conditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. ll applicable legal or institutional installation regulations must be complied with. The valve does not contain any parts that can be replaced or repaired by the user. The valve is not allowed to be disposed of as household refuse. ll locally valid regulations and requirements must be observed. The recognized rules should be applied when determining the flow characteristic of final controlling elements. The characterized control valve is operated by a rotary actuator. The actuator is controlled by a standard modulating or 3-point control system and move the ball of the valve the throttling device to the opening position dictated by the control signal. Open the ball valve counterclockwise and close it clockwise. Equal-percentage characteristic of the flow rate ensured by the integral characterizing disc. Recommended mounting positions The valve may be mounted either vertically or horizontally. It is not permissible, mounting the valve with the stem pointing downwards. 90 90 Water quality requirements aintenance Direction of flow The water quality requirements specified in VDI 2035 must be adhered to. Characterized control valves are relatively sensitive control devices. In order to ensure a long service life, it is advisable to fit strainers. The characterized control valves and rotary actuators are maintenance-free. efore any kind of service work is carried out on actuator sets of this type, it is essential to isolate the rotary actuator from the power supply (by unplugging the power lead). ny pumps in the part of the piping system concerned must also be switched off and the appropriate isolating fittings closed (allow everything to cool down first if necessary and reduce the pressure in the system to atmospheric). The system must not be returned to service until the ball valve and the rotary actuator have been properly reassembled in accordance with the instructions and the pipework has been refilled in the proper manner. The direction of flow, specified by an arrow on the housing, is to be complied with, since otherwise the ball valve can be damaged. Please ensure that the ball is in the correct position. = 100% = 0% = 0% = 100% 2 / 3 T5-R5.. Control en v1.2 05.2012 Subject to changes www.belimo.com

R5.. Characterized control valves, 3-way, with external thread ccessories eschreibung echanical accessories Stem heating ZR24-1 1) Pipe connector ZR45.. 1) No stem heating is available for R5..K, R529, R538 and R548 Dimensions and weights Dimensional drawings min. Y min. X H 2) 42 DN H [Inches] X 1) Y 1) Weight [kg] 10 69 31.5 34 ³/₄ 220 90 0.4 15 74 44 38 1 220 90 0.7 20 85.5 46 42.5 1 ¹/₄ 220 90 1.0 25 84.5 46 47.5 1 ¹/₂ 220 90 1.1 32 R529 103.5 46 56 2 220 90 1.7 32 R531 107.5 50.5 56 2 230 90 1.8 40 114.5 50.5 60.5 2 ¹/₄ 230 90 2.3 50 131.5 56 71.5 2 ³/₄ 240 90 3.8 1) inimum distance with respect to the valve centre. 2) The actuator dimensions can be found on the respective actuator data sheet.. Further documentations Overview Valve-actuator combinations Data sheets for actuators Installation instructions for ball valves and/or actuators Notes for project planning (hydraulic characteristic curves and circuits, installation regulations, commissioning, maintenance etc.) www.belimo.com T5-R5.. Control en v1.2 05.2012 Subject to changes 3 / 3

R4..(K) Y R5..(K) H X 70167-00001.D DN mm KR.. TR.. R.. NR.. SR.. TRF.. RF.. NRF.. SRF.. mm H X Y X Y X Y X Y X Y X Y X Y X Y X Y R405K... R409K R505K... R508K 10 ³/₄ 69 31.5 34 138 75 173 75 187 75 218 80 218 80 178 60 188 90 188 90 188 90 R409... R415 R509... R515 15 1 74 44 37 150 75 185 75 195 75 230 80 230 80 190 60 200 90 220 90 220 90 R417... R420 R517... R520 20 1¹/₄ 85.5 46 42.5 200 75 235 80 235 80 205 90 225 90 225 90 R422... R425 R522... R525 25 1¹/₂ 84.5 46 47.5 200 75 235 80 235 80 205 90 225 90 225 90 R429... R430 32 2 97.5 46 200 75 235 80 235 80 205 90 225 90 225 90 R529... R530 32 2 103.5 46 56 200 75 235 80 235 80 205 90 225 90 225 90 R431... R432 32 2 102 50.5 240 80 240 80 230 90 230 90 R531... R532 32 2 107.5 50.5 56 240 80 240 80 230 90 230 90 R438... R440 40 2¹/₄ 103.5 50.5 240 80 240 80 230 90 230 90 R538... R540 40 2¹/₄ 114.5 50.5 60.5 240 80 240 80 230 90 230 90 R448... R450 50 2³/₄ 115.5 56 245 80 235 90 R548... R550 50 2³/₄ 131.5 56 71.5 245 80 235 90

k v Y 5 100% 0% p vmax <350 kpa 5 100% 0% 0% 100% k v Y 100% 0% p vmax <1000 kpa 100% 0% 0% 100% 90 90 100% 0% 0% 100%