Overview of types. Technical data



Similar documents
DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Type overview. Technical data

Products no longer available

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

2- and 3-port valves with flanged connections, PN 10

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Butterfly Valves PN 6/10/16 for flanged connection

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Mikrotherm. Manual radiator valves. To be precise.

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

3/2-way Mini Solenoid Valve

Self-operated Temperature Regulators Temperature Regulator Type 1u

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

HERZ-Thermal Actuators

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Series description: Wilo-Drain TC 40

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Assisted lift operated 2/2-way solenoid valves Type EV250B

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Thermostatic element RAVV for 2-way valves

Thermostatic valve Type AVTA

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

3/2- and 2/2-way cartridge valve type BVE

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Series description: Wilo-Star-Z

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

4 Posiflow Proportional Solenoid Valves

SISTO-16TWA/HWA/DLU. Type Series Booklet

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Type 3353 Angle Seat Valve

Stainless Steel Single and Dual Circulation Kits

kymanual or Automatic - it s your Choice

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

2/2 and 3/2 Way Size 6 Seat Valves

3/2-way Solenoid Valve, direct-acting, NC or NO

Technical data. Danfoss DHP-A

Catalogue Wilo- Stratos PARA

Hydraulic Control Solutions

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Return line filters. Return line filters

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Automatic Bypass Control AVDO

Flamco. Flexcon M. Installation and operating instructions Flamco

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Electric Rotary Actuator - On/Off or programmable control actuator

Automatic control equipment for HVAC systems

Series description: Wilo-Yonos MAXO

How To Use A Flowmeter

PRESSURE REDUCING CONTROL VALVE

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Electro-hydraulic pressure switches type DG

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Pressure relief valves Size 6

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

VAD Variable Area Desuperheaters

Pressure regulating valve with modulating kit, type DRV

Automatic balancing valves ASV

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Richter Twin Piston Quarter-turn Actuators

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Directional seated valves type VP 1

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Heating, air-conditioning, cooling

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

VAD. Variable Area Desuperheaters

Pressure reducing valve, direct operated, Type ZDR 6 D

Data sheet ECC 12 and 22

4/2-Way Pneumatic Solenoid Valve

Chapter 5: Flow Valves

stainless steel pre-assembled manifolds

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

PS1800 Centrifugal Pumping Systems

Plastic tube flowmeters Series PT/PS

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Typical Aluminum GFM Mass Flow Meter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

Transcription:

Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight (control path - ) Overview of types Type kvs [m³/h] DN [ ] ps [kpa] n(gl) Sv min. R3015-P25-S1 0.25 15 1/2 1600 3.2 50 R3015-P4-S1 0.4 15 1/2 1600 3.2 50 R3015-P63-S1 0.63 15 1/2 1600 3.2 50 R3015-1-S1 1 15 1/2 1600 3.2 50 R3015-1P6-S1 1.6 15 1/2 1600 3.2 50 R3015-2P5-S1 2.5 15 1/2 1600 3.2 50 R3015-4-S1 4 15 1/2 1600 3.2 100 R3020-4-S2 4 20 3/4 1600 3.2 100 R3020-6P3-S2 6.3 20 3/4 1600 3.2 100 R3025-6P3-S2 6.3 25 1 1600 3.2 100 R3025-10-S2 10 25 1 1600 3.2 100 R3032-16-S3 16 32 1 1/4 1600 3.2 100 R3040-16-S3 16 40 1 1/2 1600 3.2 100 R3040-25-S4 25 40 1 1/2 1600 3.2 100 R3050-25-S4 25 50 2 1600 3.2 100 R3050-40-S4 40 50 2 1600 3.2 100 R3050-58-S4 58 50 2 1600 3.2 100 Technical data Functional data edia Cold and hot water, water with glycol up to max. 50% vol. edium temperature -10 C... 120 C edium temperature note The allowed media temperature can be limited, depending on the type of actuator. The correct values can be found in the respective actuator sheets. Closing pressure ps 1400 kpa Differential pressure pmax 350 kpa Differential pressure note (200 kpa for low-noise operation) Flow characteristic Control path : equal percentage (in accordance with VDI/VDE 2178) eakage rate Control path, ir bubble-tight (EN 12266-1) eakage class ypass eakage Class I (DIN EN 1349 and DIN EN 60534-4) 1... 2% of kvs, in relation to the highest value within the DN Pipe connectors Internal thread in accordance with ISO 7/1 ngle of rotation with limitation 90 (operating range control path 15... 90, bypass 15... 70 ) Installation position Upright to horizontal (in relation to the spindle) aintenance aintenance-free www.belimo.com T5-R3..xx-S.. en v1.0 02.2012 Subject to changes 1

= 100% = 0% R3..xx-S.. Technical data aterials Valve Forged, nickel-plated brass body Valve cone Stainless steel Spindle Stainless steel Stem seal O-ring EPD Valve seat PTFE, O-Ring EPD (DN20 Viton) Characterising disk Path -: DN15... DN50 TEFZE (R3040-25-S4, R3050-40-S4, R3050-58-S4: Stainless Steel) Safety notes The ball valve has been designed for use in stationary heating, ventilation and airconditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Only authorised specialists may carry out installation. ll applicable legal or institutional installation regulations must be complied with during installation. The ball valve does not contain any parts that can be replaced or repaired by the user. The ball valve may not be disposed of as household refuse. ll locally valid regulations and requirements must be observed. When determining the flow rate characteristic of controlled devices, the recognised directives must be observed. Product features Principle of operation Flow characteristic Recommended installation positions The characterised control valve is adjusted by a rotary actuator. The actuator is controlled by a commercially available modulating or 3-point control system and moves the ball of the valve the throttling device to the position dictated by the positioning signal. Open the characterised control valve counterclockwise and close it clockwise. Equal percentage flow control is ensured by the integrated characterising disk. The ball valve can be installed upright to horizontal. The ball valve may not be installed in a hanging position, i.e. with the spindle pointing downwards. 90 90 Water quality requirements aintenance Flow direction The water quality requirements specified in VDI 2035 must be adhered to. Characterised control valves are regulating devices. The use of dirt filters is recommended in order to prolong their service life as modulating instruments. all valves and rotary actuators are maintenance-free. efore any kind of service work is carried out on the actuator, it is essential to isolate the rotary actuator from the power supply (by unplugging the electrical cable). ny pumps in the part of the piping system concerned must also be switched off and the appropriate slide valves closed (allow everything to cool down first if necessary and reduce the system pressure to ambient pressure level). The system must not be returned to service until the characterised control valve and the rotary actuator have been properly reassembled in accordance with the instructions and the pipeline has been refilled in the proper manner. The direction of flow, specified by an arrow on the housing, is to be complied with, since otherwise the ball valve could become damaged. Please ensure that the ball is in the correct position (marking on the spindle). 2 T5-R3..xx-S.. en v1.0 02.2012 Subject to changes www.belimo.com

R3..xx-S.. ccessories Description echanical accessories Pipe connector for characterised control valve DN 15 Pipe connector for characterised control valve DN 20 Pipe connector for characterised control valve DN 25 Pipe connector for characterised control valve DN 32 Pipe connector for characterised control valve DN 40 Pipe connector for characterised control valve DN 50 Data sheet name ZR2315 ZR2320 ZR2325 ZR2332 ZR2340 ZR2350 Dimensions / Weight Dimensional drawings min. min. X H 3) 42 1 DN Type Weight approx. [kg] [ ] 1 H X 15 R3015-P25-S1 0.27 1/2 67 13 35 36 230 90 15 R3015-P4-S1 0.27 1/2 67 13 35 36 230 90 15 R3015-P63-S1 0.27 1/2 67 13 35 36 230 90 15 R3015-1-S1 0.27 1/2 67 13 35 36 230 90 15 R3015-1P6-S1 0.37 1/2 67 13 44 36 230 90 15 R3015-2P5-S1 0.37 1/2 67 13 44 36 230 90 15 R3015-4-S1 0.37 1/2 67 13 44 36 230 90 20 R3020-4-S2 0.46 3/4 78 14 46 41.5 220 90 20 R3020-6P3-S2 0.46 3/4 78 14 46 41.5 220 90 25 R3025-6P3-S2 0.65 1 87 16 46 45 235 90 25 R3025-10-S2 0.65 1 87 16 46 45 235 90 32 R3032-16-S3 0.95 1 1/4 105 19 50.5 55.5 240 90 40 R3040-16-S3 1.15 1 1/2 111 19 50.5 56 240 90 40 R3040-25-S4 1.15 1 1/2 122 19 62 66.5 250 90 50 R3050-25-S4 1.9 2 125 22 56 68 245 90 50 R3050-40-S4 1.8 2 142 22 68 79 262 90 50 R3050-58-S4 1.8 2 142 22 68 79 262 90 1: aximum screwing depth. X/: inimum distance with respect to the valve centre. The actuator dimensions can be found on the respective actuator data sheet. Further documentation Complete overview «The complete product range of water solutions» Data sheets actuators Installation instructions for actuators and/or ball valves, respectively Notes for project planning (hydraulic characteristic curves and hydronic circuits, installation instructions, commissioning, maintenance, etc.) www.belimo.com T5-R3..xx-S.. en v1.0 02.2012 Subject to changes 3

R2..-S.. R3..-S.. H X 71270-00001. 1 t p s 10... +120 C 1600 kpa DN mm 80 C 100 C 120 C 100 C 120 C KR.. TR.. R.. NR.. SR.. TRF.. RF.. NRF.. SRF.. mm H 1 X X X X X X X X X R2015..-S1 R3015..-S1 15 ¹/₂ 67 44 36 13 150 75 185 75 195 75 230 80 230 80 190 80 200 90 220 90 220 90 R2020..-S2 R3020..-S2 20 ³/₄ 78 46 41.5 14 200 75 235 80 235 80 205 90 225 90 225 90 R2025..-S2 R3025..-S2 25 1 87 46 45 16 200 75 235 80 235 80 205 90 225 90 225 90 R2032..-S3 R3032..-S3 32 1¹/₄ 105 50.5 55.5 19 240 80 240 80 230 90 230 90 R2040..-S3 R3040..-S3 40 1¹/₂ 111 50.5 56 19 240 80 240 80 230 90 230 90 R3040-25-S4 40 1¹/₂ 122 62 66.5 19 250 80 240 90 R2050..-S4 R3050..-S4 50 2 125 56 68 22 245 80 235 90 R3050-40-S4 R3050-58-S4 50 2 142 68 79 22 262 80 252 90

k v 4 100% 0% p vmax <350 kpa 4 100% 0% 0% 100% k v 100% 0% p vmax <1000 kpa 100% 0% 0% 100% 90 90 100% 0% 0% 100%