Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP



Similar documents
T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

CT-02 CABLE TRAY SYSTEMS

Cable Support Solutions

Cat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C).

Series 1 Steel Cable Ladder

SECTION 4: Cable Ladder Stainless Steel & Aluminium

Cable Runways & Accessories

CLEAR-DIVISIONS VARIOFOLD

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

CLEAR-DIVISIONS CENTERFOLD

CABLE TRAY. Introduction

RAIL FREE SOLAR ROOF MOUNT

PW Cable Tray Ladder, Trough & Solid Bottom

CLEAR-DIVISIONS APERTO

I BEAM TRACK INSTALLATION

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Söll GlideLoc Aluminium Ladders. Vertical fall protection system Certified according to EN 353-1:2002 and CNB/P/11.073

Cooktop Low-Profile Ventilation Hoods

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION TELECOMMUNICATION ROOMS

CDGRD-10. Grounding. Solutions For Comm/Data Applications

ANTENNA PARTS CATALOG

19 DYNAmax Free Standing Server C A B I N E T s

HORIZONTAL INSTALLATION

Knürr Smaract. Knürr Smaract. CompactRack

Wall braces with a swivel head are included to accommodate all roof pitches.

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Cabinets 101: Configuring A Network Or Server Cabinet

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

FiberGuide Fiber Management Systems. 4th Edition

FRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes

Structural Holding System

ONTRAC WIRE MESH CABLE TRAY SYSTEM

BLADE S-MAX Cabinet for Blade Server

F-Series Camera Mounting Accessories

K17.11 DOOR BOLTS K17 DOORS

19 DYNAmax Free Standing Server C A B I N E T s

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

19 NETbox SOHO Network Wall Mounting Cabinets FAMILY

Dock Hardware & Accessory Products Catalog

Type 1, 3, & 3R Enclosures

SSG PRODUCTS FOR SHIPS AND OFFSHORE

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

CENTERLINE Motor Control Centers Splicing Horizontal Ground Buses

CRASH RAIL INSTALLATION HEIGHT

RPS - sales@rpssolar.com San Bruno Cove, San Diego, CA 92130

Wisconsin Building Products Evaluation

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Dynarail Guardrail, Handrail & Ladder

PART 1 GENERAL 1.1 SECTION INCLUDES

SECTION 6. Glass Storefront Doors:

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-115C

Clad Direct Glaze Window Installation Instructions

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Terminal Boxes Series 8146

EMI/RFI Shielded Cable Tray

SKT-SP Tangent Terminal

Pipe Cutting and Beveling Clamshells

Casement/Awning Window Parts Reference Catalog

Timber Decks. Technical Note. March 2007

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Modular Truck Equipment Price List March 1,

Furniture Fittings Furniture Handles and Knobs

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

NEMA Standards Publication VE Cable Tray Installation Guidelines

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Sliding and Folding Door Fittings Sliding Door Accessories

1-Way Bracket Assemblies

Aluminium systems profile selection

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Secure your IT equipment with confidence... secure with NetClosure

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Best Practice Guide to Cable Ladder and Cable Tray Systems

Mini USB and USB 2.0-IP67 Connector System

This presentation to be used in conjunction with:

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Coaxial Cable Installation Accessories

Step by Step instructions How to screw in wood and plastic

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Uncovered Decks & Porches

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

PITCHED ROOF STRUCTURES

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.

Rack Systems Solutions

Pulleys and Belt. Install the Major Accessory and Pulley. Install the Motor Pulley NOTE. Align the Motor Pulley and the Tool Pulley NOTE

FLEXTRAY. It s Simple Cable Management CBFT-10. Catalog & Product Installation Guide

Unpacking, Installation, and Customization

Data Centre Solutions

Cable Tie Mounting Bases

CDW Systems Ltd Contemporary Doors & Windows

Transcription:

Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No. Material Siderail Height ABW--SSP ABW--SSP ABW-6-SSP 6 ABW-7-SSP 7 Snap-In Expansion Splice Plate Allows for a 1 in. expansion or contraction of tray system. Packaged in pairs with zinc plated hardware. Cat. No. Material Siderail Height ABW--ESP ABW--ESP ABW-6-ESP 6 ABW-7-ESP 7 Horizontal Adjustable Plate Adjustable hinge plates provide maximum horizontal installation flexibility. Furnished in pairs with hardware.. Cat. No. Material Siderail Height (in.) For Tray Width 6 in. to 2 in. ABW(*)2HSP inclusive 6 30 in. to 36 in. ABW(*)36HSP 7 inclusive (*) Insert Siderail Height. Vertical Adjustable Plate Cat. No. Material Siderail Height in. ABW--VSP ABW--VSP ABW-6-VSP 6 ABW-7-VSP 7 Hinged vertical plates provide maximum flexibility for changes in elevation. Furnished in pairs with hardware. T&B aluminum cable tray is composed of two distinct systems H-Style and U-Style. These systems are interchangeable. A101

Metallic Branch Pivot Connectors Cat. No. Material Siderail Height (in.) Allows cables to run from one tray level to another. Box to Tray Plates ABW--BPC ABW--BPC ABW-6-BPC 6 ABW-7-BPC 7 Cat. No. Material Siderail Height (in.) ABW--BSP ABW--BSP ABW-6-BSP 6 ABW-7-BSP 7 Designed to secure tray to electrical panels or boxes, walls or end supports. Furnished in pairs with hardware. Closure End Plate Provides closure for any tray end. Packaged with hardware. Reducing Splice Plate Offset Straight Used in pairs to provide a straight reduction or used with a standard splice plate for an offset reduction. Packaged with hardware. Step Down Splice Plate Connects siderails of different heights. Hardware included. T&B aluminum cable tray is composed of two distinct systems H-Style and U-Style. These systems are interchangeable. Cat. No. Material Siderail Height (in.) Widths of Tray (in.) ABW--ESP 06 09 ABW--ESP 12 18 ABW-6-ESP 6 2 30 ABW-7-ESP 7 36 (*) Insert width of Tray. Cat. No. Material Siderail Height (in.) ABW-(*)-RSP ABW-(*)-RSP ABW-6(*)-RSP 6 ABW-7(*)-RSP 7 NOTE: (*) For offset reduction: insert width to be reduced. For straight reduction: insert 1/2 width to be reduced (2 required). Example: ABW-03-RSP = 3 in. offset reducer. Cat. No. Material Siderail Height (in.) ABW(*)(**)SDS (*) Siderail Height 1. (**) Siderail Height 2. NOTE: Siderail Height 1 is greater then Siderail Height 2. 6 7 A102

Metallic Mid-Span Splice Plate Mid-Span Splice Plate Features Factory pre-drilled side rails for above series easy installation. Allows random connexion location. Tested loading 160 lb./ft., based on a 20 ft.. simple beam test with 1. safety factor (tested with AH66 series). Supplied with stainless steel type 316 hardware. Available on ladder, vented or solid tray style. Only available in the following series of aluminum tray: AH6, AH6, AH66 and AH76*. *(20 ft.. Support Span only). The Splice Plate 3/8 in.-16 x 3/ in. SS316 carriage bolt and serrated flanged nuts Cable Tray Mid-Span Slice Plate Reinforcing plate Part #: ABW6SSPMS 3/8 in.-16 x 1 in. SS316 carriage blot and serrated flanged nuts A103

Metallic Mid-Span Splice Plate Typical Installation of Mid-Span Splice Plate These heavy-duty splice plates are designed to allow random splice location, including the midspan for 20 ft.. support spans. These splices are available for all long-span, ladder, vented or solid tray style. Straight Section Number Selection (AMS-6)-2-L09-6 Material Series Siderail Depth Width Bottom Type Length AMS Mid-Span Splice Series Series 6 Series 6 7 Series 7 Prefix 6 (6 in.) 06 (6 in.) 09 (9 in.) 12 (12 in.) 18 (18 in.) 2 (2 in.) 30 (30 in.) 36 (36 in.) To order straight sections with Mid-Span Splice Plate, replace AH in the standard part number with AMS. Example: AH662L12-6 AMS662L12-6 L06 6 in. rung spacing L09 9 in. rung spacing L12 12 in. rung spacing V Ventilated S Solid Trough 6 (6 meters) 288 (2 ft.) A10

Metallic Place splices directly over supports No additional support required Over Support Splice Adaptor (Beam Installation) A10

Metallic Standard 1/ Span Typical Installation Supports are placed at 1/ span (2%). Expansion joints need extra support at 1/2 span to prevent excessive deformation of the tray under heavy loads. New Over Support Typical Installation Supports are placed right under the joints of the installation. The splice adaptor allows a wider distribution of the support, therefore minimizing the stress and deflection of the assembly. Standard Splice Plate 2% Span Standard Splice Plate 2 Over Support Splice Adaptor Span Span Expansion Splice Plate NOTE: Independent of the installation method chosen, AU/AH6 straight sections are CSA approved for Class E loading. (100%) Beam Installation ABW6-OSS-B BOTTOM VIEW Required on expansion joint only 1 2 3 6 Required on anchored joint only 3 Installation Components 1. Bonding jumper 2. Splice plate 3. Over support splice adaptor. Beam clamp. Hold down clamp 6. Structural beam 7. Strut (see right page) A106

Metallic Expansion % Span Splice Plate 2% Span Standard Splice Plate Extra Support Required Over Support Splice Adaptor Standard Splice Plate Over Support Splice Adaptor NEMA VE2: Splice joints should be designed and placed so as to maximize the rigidity of the cable tray over support. Splice plates and adaptors are part of a system specifically designed for placement directly over supports. Strut Installation ABW6-OSS-S INSIDE VIEW Required on expansion joint only 1 2 3 Required on anchored joint only 7 Cable Tray Installation Every second splice must be an expansion joint. For gap setting at expansion joint, refer to NEMA chart on next page. For use with T&B Cable Tray series AH6. Max. load of 80 lb/ft, 20 ft. span. Every joint must have a pair of over support splice adaptors (both standard splices and expansion splices) A107

Metallic ABW6-OSS-B Beam Installation Expansion over support beam 29 in. SHW-CTC, Heavy-Duty hold down clamp (complete with mounting hardware) SHW-HEC, Standard hold down clamp E12-3/8x100EG, 3/8 in. - 16 x 1 in. hex cap screws AC100-3/8EGC, 3/8 in. strut nut NOTE: Every expansion joint requires the use of a bonding jumper such as FBD16-1 (16 in., 600 amps) ABW6-OSS-S Strut Installation Expansion over support beam 29 in. SHW-HEC, Standard hold down clamp E12-3/8x100EG, 3/8 in. - 16 x 1 in. hex cap screws AC100-3/8EGC, 3/8 in. strut nut NOTE: Every expansion joint requires the use of a bonding jumper such as FBD16-1 (16 in., 600 amps) Expansion Plate Gap Chart Metal Temperature at Time for Installation Gap Settings po (mm) A108