ALPHA Meter Installation Information



Similar documents
Laser Wireless Rechargeable Mouse. User s Manual

Dual-Cool Notebook Cooler Pad. User s Manual

Optical Wireless Mouse. User s Manual

Usage, Installation, Warranty and Service Information

AVerMedia AVerKey imicro User s Manual

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

BroadBand PowerShield. User Manual

2013 VTech Printed in China US

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

USB Port Hub with USB Power Cable. User s Manual

User Guide for the Wireless Headset (HS-11W) Issue 1

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

7 High-Resolution Digital Photo Frame

Caller-ID on your TV!

User manual. Your best protection against theft and loss. (Android) Made for

Spivi Installation Manual

Power Over Ethernet Adapters POE101

7 Digital Photo Frame Instructional Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

15 Digital Photo Frame Instructional Manual

USB/VGA Cat 5 UTP Console Extender

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

3.5 mm Audio Jack. Manual innoxplore ix B24 A2DP Stereo Bluetooth Audio Adapter Dongle 3.5mm Audio Jack [ix B24] Contents

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

StructureScan HD Module. Installation Guide ENGLISH

Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT. Perfect for ANDROID TM

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Manual. Simrad StructureScan LSS-1 Sonar Module. English

DELORME. Getting Started with. Earthmate GPS BT-20. Bluetooth

Quick Start Guide. Model #s: / / / / Lit# /02-10

Installer Guide smart connect

WristPC. WristPC Wearable Keyboard QWERTZ Special (Version 2.0L and above) Copyright L3 Systems, Inc. Redmond, WA

User Guide LAPTOP CHARGER WITH SMARTPHONE BACKUP BATTERY N2953

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Alarm Clock USER GUIDE

iosafe Solo External Hard Drive

VS-0202 VS User Manual

Alarm Clock USER GUIDE

Adaptive Log Exporter Service Update

Bluetooth Stereo Headphone. User Guide. Hive

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

Pebble. E-Paper Watch for iphone and Android. 1 Button A. 4 Button B. 5 Button C. 2 Display. 6 Button D. 3 Charge Port

Wireless Indoor/ Outdoor Thermometer

Wireless Travel Mouse with 5-Buttons User Manual

Directed Passive Keyless Entry System (PKE) Model 2102T Owner s Guide

Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL

Dome Security Camera with IR night vision

USB 2.0 Peripheral Switch USER MANUAL US221A / US421A

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

READ FIRST! Universal Car/Air Adapter User Manual

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

User Guide. BLUETOOTH WIRELESS KEYBOARD for ipad

Internal Drive Mounted Dual SATA Hard Drive RAID Adapter

NFC Communication Tray Model: HHX-IT3-Z

PrintPAD CN3/4/3e/4e. User Guide

BTX180 Wireless Bluetooth Speaker

Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE

9,'(2 #6(3$5$725 8VHU V#0DQXDO

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

8 Digital Photo Frame Instructional Manual

Instruction Guide. Professional VGA to NTSC/PAL TV Converter with Remote VGA2NTSCPRO. The Professionals Source For Hard-to-Find Computer Parts

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

DVI to Mini DisplayPort Converter. EXT-DVI-2-MDP User Manual

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

USB to IDE or SATA Adapter

Wireless Optical Mouse

2GB MP3 Player USER GUIDE

Weather Radio Alarm Clock

Owner's Manual STEREO EARPHONES WITH BLUETOOTH WIRELESS TECHNOLOGY. Model: CBH515-OD PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

DVI Video Splitter USER MANUAL VS-162 / VS-164

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Intelli-Time Alarm Clock model 13027

Model: Manual DC: WIRELESS COLOR FORECAST STATION

USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

User Guide for the Kidde RemoteLync. Remote Notification Device

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Pad. Quick Start Guide

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

PORTABLE ALARM CLOCK. Dual Alarm. FM Radio. Wake-up Sounds. USB Phone Charger G-1CR

P-660HN n Wireless ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware Version 1.10 Edition 1, 9/2010. IP Address:

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Universal Laptop Charger

e-ask electronic Access Security Keyless-entry

Mini Power Bank and Charger

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

VGA+HDMI to HDMI Audio/Video Converter Switch

SSDNow For Desktops. Installation Guide

ST122VGAU. Instruction Manual. VGA Video Switch. 2-Port Automatic VGA Video Switch

Instruction Guide. 4 Port Laptop-Sized USB 2.0 Mini Hub ST4200MINI. The Professionals Source For Hard-to-Find Computer Parts

VOIP Business Phone User Guide

Wireless Mouse USER GUIDE. for Mac. ONE YEAR LIMITED WARRANTY N2953

u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions

USER MANUAL VS92A / VS94A / VS98A

Transcription:

October 006 IL4-400Q ALPHA Meter Installation Information General This instructional leaflet contains general installation instructions for the following single phase and polyphase watthour meters: socket-connected meters: S, S, S, 4S, 5S, 6S, 8S, 9S, 0S, S, S, 6S, 6S, 9S, 5S, 6S, 45S, 56S bottom-connected meters: 5A, 6A, 0A, A, 6A, 5A, 6A, 45A See the following technical manuals for more information about the ALPHA meter: ALPHA Meter Technical Manual (TM4-80A or later) ALPHA Meter Options Technical Manual (TM4-8B or later) ALPHA Plus Meter Technical Manual (TM4-8C or later) A ALPHA Meter Technical Manual (TM4-90A or later) All meters are calibrated and tested before shipment. For proper installation, accuracy, and maximum life of the meters, use the following installation procedures. Use authorized utility procedures to install and service metering equipment. Dangerous voltages are present. Equipment damage, personal injury, or death can result if safety precautions are not followed. Use circuit closing devices on any current transformer secondaries (S, 4S, 5S, 5A, 6S, 6A, 8S, 9S, 0S, 0A, 6S, 9S, 5S, 5A, 6S, and 6A meters). Equipment damage, personal injury, or death can result if circuit closing devices are not used. Socket-connected Installation Before you install the meter, check the following: Are the socket and meter current class ratings compatible with the meter? Is the wiring to the meter socket correct? See the wiring diagrams on the following pages. Is a lightning arrestor present? If so, remove the paint from the socket rim where it contacts the arrestor s ground strap. This will ensure proper grounding. Is the TEST button in the unlocked position? If the TEST button is in the locked position, the meter will enter TEST mode when you install it. For more information, see the technical manual for your meter. After you install the meter, check the following: If load is applied, check that the pulse arrows on the LCD are blinking. The LCD has sets of pulse arrows, one located above the other. The upper set of arrows indicates watthours, and the lower set indicates alternate energy (kvarh or kvah, if available). The arrows pointing to the left indicate energy received; arrows pointing to the right indicate energy delivered. For more information, see the technical manual for your meter. Elster Electricity, LLC Raleigh, orth Carolina USA + 800 8 55 (US toll free) + 99 4800 support@us.elster.com www.elsterelectricity.com

IL4-400Q October 006 Bottom-connected Installation Before you install a bottom-connected meter, check the following: Determine where the meter is to be installed. It should be on a flat wall at the point of electrical service entrance cables. Are the meter class and service connections compatible with the meter? To install a bottom-connected meter, perform these steps: Mount the bottom-connected meter or the bottom-connected S-to-A adapter. Use authorized utility procedures to install ground connection before wiring. Dangerous voltages are present. Equipment damage, personal injury, or death can result from wiring an ungrounded meter. Wire the meter. See the wiring diagrams beginning on page. If the wire diagram is larger than the wire, use only approved adapters. External meter wiring should be consistent with the meter class rating. For 00 amp meters, use # wiring (or in accordance with standard utility operating practices) For 50 amp meters, use # AWG or 50 mm wiring (or in accordance with standard utility operating practices) For transformer rated meters, use #9 wiring (or in accordance with standard utility operating practices) After you install a bottom-connected meter, check the following: If load is applied, check that the pulse arrows on the LCD are blinking. The LCD has sets of pulse arrows, one located above the other. The upper set of arrows indicates watthours, and the lower set indicates alternate energy (kvarh or kvah, if available). The arrows pointing to the left indicate energy received; arrows pointing to the right indicate energy delivered. For more information, see the technical manual for your meter. The TEST annunciator is not blinking. If it is blinking, then remove the meter from service, remove the cover, and rotate the TEST button so that the meter is placed out of test mode. For more information, see the technical manual for your meter. Installation Wiring All available ALPHA meter forms are listed and separated with respect to the type of service being metered. Use of Form 9S, 0S, and 0A (in 8S and 8A applications), and Form 6S (in Form 5S application) are also shown. Form 4S and 4A applications are simply 4 wire WE services and would be metered by Form 6S and 6A. The more complicated wirings are shown using both PTs and CTs. The socket ground is shown for safety considerations. The neutral-to-ground connection is shown for example only. Actual neutral-to-ground connection should be performed within the operating utility s standard practice. ot supplied by Elster Electricity, LLC.

October 006 IL4-400Q Single phase meters Form S phase, wire, self contained Form S phase, wire, self contained Form S phase, wire, CT, no PTs 0E0 L O A D 0E0 L O A D 9A0 CLOSIG Form S phase, wire, CT, no PTs Form 4S phase, wire, CTs, no PTs CLOSIG CLOSIG 4I0 Reduce CT ratio by ½ 9A0 wire delta meters Form 5S phase, wire delta, CTs, 0 or PTs Form 5A phase, wire delta, CTs, 0 or PTs Form S phase, wire delta, self contained CLOSIG L O A D 0E0 0E0 0E0

IL4-400Q October 006 wire delta meters Form S phase, wire delta, self-contained Form A phase, wire delta, self-contained Form 6S phase, wire delta, CTs, 0 or PTs L O A D L O A D CLOSIG A06 0E0 0E0 0E0 Form 5S phase, wire delta, CTs, 0 or PTs Form 5A phase, wire delta, CTs, 0 or PTs Form 45S phase, wire delta, CTs, 0 or PTs CLOSIG CLOSIG 0E0 0E0 Form 45A phase, wire delta, CTs, 0 or PTs Form 56S phase, wire delta, CTs, 0 or PTs CLOSIG A06 0E0 4

October 006 IL4-400Q wire wye meters Form 5S phase, wire wye, CTs, no PTs Form 5A phase, wire wye, CTs, no PTs Form S phase, wire wye, self-contained CLOSIG L O A D 0E0 0E0 0E0 Form S phase, wire wye, self-contained Form A phase, wire wye, self contained Form 6S phase, wire wye, CTs, 0 PTs 0E0 L O A D 0E0 L O A D 6C06 CLOSIG Form 5S phase, wire wye, CTs, no PTs Form 5A phase, wire wye, CTs, no PTs Form 45S phase, wire wye, CTs, no PTs CLOSIG CLOSIG 0E0 0E0 A06 5

IL4-400Q October 006 wire wye meters Form 45A phase, wire wye, CTs, no PTs Form 56S phase, wire wye, CTs, 0 PTs CLOSIG A06 6C06 4 wire delta meters Form 5S phase, 4 wire delta, CTs, PTs Form 5A phase, 4 wire delta, CTs, PTs Form 9S (Form 8S application) phase, 4 wire delta, CTs, no PTs 0E0 CLOSIG 0E0 CLOSIG Reduce CT ratio by ½ Reduce CT ratio by ½ E0 Form 0S (Form 8S application) phase, 4 wire delta, CTs, no PTs Form 0A (Form 8A application) phase, 4 wire delta, CTs, no PTs Form 6S (Form 5S application) phase, 4 wire delta, self-contained 0E0 CLOSIG E0 L O A D Wiring is different than a traditional Form 8 meter Wiring is different than a traditional Form 8 meter 0E0 6

October 006 IL4-400Q 4 wire delta meters Form 6A (Form 5A application) phase, 4 wire delta, self-contained phase, 4 wire delta, CTs, PTs Form 6S Form 6S phase, 4 wire delta, CTs, no PTs 0E0 L O A D 9A0 CLOSIG Reduce CT ratio by ½ 0C06 CLOSIG Reduce CT ratio by ½ 60 Hz only ALPHA Plus with autodetection enabled & A ALPHA only Form 5S phase, 4 wire delta, CTs, PTs Form 5S phase, 4 wire delta, CTs, no PTs Form 5A phase, 4 wire delta, CTs, PTs 60 Hz only ALPHA Plus with autodetection enabled & A ALPHA only CLOSIG CLOSIG 7A0 C06 Reduce CT ratio by ½ 6C06 Reduce CT ratio by ½ Reduce CT ratio by ½ Form 5A phase, 4 wire delta, CTs, no PTs Form 45S phase, 4 wire delta, CTs, no PTs Form 45A phase, 4 wire delta, CTs, no PTs 60 Hz only ALPHA Plus with autodetection enabled & A ALPHA only CLOSIG 6C06 0C06 Reduce CT ratio by ½ Reduce CT ratio by ½ Reduce CT ratio by ½ 0C06 7

IL4-400Q October 006 4 wire delta meters Form 56S phase, 4 wire delta, CTs, no PTs CLOSIG 6C06 Reduce CT ratio by ½ 4 wire wye meters Form 5S phase, 4 wire wye, CTs, 0 or PTs Form 5A phase, 4 wire wye, CTs, 0 or PTs Form 6S phase, 4 wire wye, CTs, 0 or PTs CLOSIG CLOSIG 0E0 0E0 E0 Form 6A phase, 4 wire wye, CTs, 0 or PTs Form 9S phase, 4 wire wye, CTs, 0 or PTs Form 0S (Form 9S application) phase, 4 wire wye, CTs, 0 or PTs E0 0E0 E0 CLOSIG CLOSIG Does not strictly conform to the traditional Form 0S wiring. It is intended for most 0S applications. One side of each voltage section is wired common within the meter. This wiring restricts the use of phase shifting transformers to perform reactive measurement. If attempted, equipment damage can occur. 8

October 006 IL4-400Q 4 wire wye meters Form 0A (Form 9A application) phase, 4 wire wye, CTs, 0 or PTs Form 6S (Form 4/6S application) phase, 4 wire wye, self contained Form 6A (Form 4/6A application) phase, 4 wire wye, self contained L O A D L O A D 0E0 0E0 0E0 Form 6S Form 9S Form 5S phase, 4 wire wye, CTs, 0 or PTs phase, 4 wire wye, CTs, 0 or PTs phase, 4 wire wye, CTs, 0 or PTs CLOSIG CLOSIG CLOSIG 0E0 B0 0E0 Form 5A Form 6S Form 6A phase, 4 wire wye, CTs, 0 or PTs phase, 4 wire wye, CTs, 0 or PTs phase, 4 wire wye, CTs, 0 or PTs CLOSIG 0E0 E0 0E0 9

IL4-400Q October 006 4 wire wye meters Form 45S phase, 4 wire wye, CTs, 0 or PTs Form 45A phase, 4 wire wye, CTs, 0 or PTs Form 56S phase, 4 wire wye, CTs, 0 or PTs CLOSIG CLOSIG 7A06 7A06 7A06 Do not disassemble the meter chassis or the electronic module from the meter chassis with power present. Doing so could expose you to dangerous voltages, resulting in equipment damage, personal injury, or death. 0

October 006 IL4-400Q Battery Installation and Replacement Time-of-use meters are typically shipped with the battery installed and connected. If the battery is requested to be shipped disconnected, separately, or as a replacement, see the technical manual for procedures for battery installation or replacement. It is important that the battery not be connected unless the meter has been powered for at least minute from the AC line within the last hour. It is important that the meter is not energized while the battery is being installed or replaced (see the technical manual). After connecting the battery and re-energizing the meter, the display should be checked to verify proper operation (that is, scrolling from one display quantity to the next). Failure to follow the correct sequence for battery connection can result in early battery discharge, the register being inoperative, or both. Relay Output Color Coding Multiple relay output configurations are available with high voltage, solid state relays. The relay outputs can be identified based on the number of output leads and their color coding. The following configurations are available: relay with 6 output leads (see Figure ) relays with 6 output leads (see Figure ) 4 relays with 8 output leads (see Figure ) 4 relays with 9 output leads (see Figure ) 6 relays with output leads (see Figure 4) In all cases, the output leads exit the meter using approximately 4 inches of cable. Regardless of the configuration present, the relays are assigned as follows: For ALPHA and ALPHA Plus meters: is dedicated to kwh delivered. is dedicated to kvah delivered (for A or A+ meters) or kvarh delivered (for AR or AR+ meters) When present, is dedicated to kwh received. When present, 4 is dedicated to kvah received (for A or A+ meters) or kvarh received (for AR or AR+ meters) For A ALPHA meters: All relays are fully programmable. Sources for the relays can be any basic metered quantity, EOI, load control, PQM test failure, or relay-related alarm condition. See the A ALPHA Meter Technical Manual (TM490B or later) and the Metercat User Guide (TM4-04B or later) for specific information.

IL4-400Q October 006 C RELA A relay applications O use only Relay A COMMO ellow Black Red ALPHA & ALPHA Plus kwh delivered A ALPHA RELA B COMMO C O Wht/Blk Blue Orange as, LC, or EOI Figure. Color coding for or relays with 6 output leads RELA A RELA B C O C O ellow Black Wht/Blk Blue ALPHA & ALPHA Plus kwh delivered as, LC, or EOI A ALPHA RELA E O COMMO Orange Red EOI EOI RELA F O COMMO Brown Green LC LC Load control Figure. Color coding for 4 relays with 8 output leads RELA A C O COMMO ellow Black Red A ALPHA only RELA B C O COMMO Wht/Blk Blue Red RELA C C O COMMO Violet White Red RELA D C O COMMO Gray Wht/Brn Red Figure. Color coding for 4 relays with 9 output leads

October 006 IL4-400Q RELA A RELA B RELA C RELA D C O C O C O C O ellow Black Wht/Blk Blue Violet White Gray Wht/Brn 4 4 ALPHA & ALPHA Plus kwh delivered as, LC, or EOI kwh received 4 kvarh/kvah received A ALPHA RELA E O COMMO Orange Red EOI EOI RELA F O COMMO Brown Green LC LC Load control Figure 4. Color coding for 6 relays with output leads

IL4-400Q October 006 otes: 4

October 006 IL4-400Q otes: 5

IL4-400Q October 006 FCC Compliance Class B Device This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced radio/tv technician for help DISCLAIMER OF WARRATIES AD LIMITATIOS OF LIABILIT There are no understandings, agreements, representations, or warranties either express or implied, including warranties of merchantability or fitness for a particular purpose, other than those specifically set out by any existing contract between the parties. Any such contract states the entire obligation of the seller. The contents of this document shall not become part of or modify any prior existing agreement, commitment, or relationship. The information, recommendations, descriptions, and safety notices in this document are based on Elster Electricity, LLC experience and judgment with respect to operation and maintenance of the described product. This information should not be considered as all-inclusive or covering all contingencies. If further information is required, Elster Electricity, LLC should be consulted. o warranties, either expressed or implied, including warranties of fitness for a particular purpose or merchantability, or warranties arising from the course of dealing or usage of trade, are made regarding the information, recommendations, descriptions, warnings, and cautions contained herein. In no event will Elster Electricity, LLC be responsible to the user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental, or consequential damage or loss whatsoever, including but not limited to: damage or loss of use of equipment, cost of capital, loss of profits or revenues, or claims against the user by its customers resulting from the use of the information, recommendations, descriptions, and safety notices contained herein. Elster Electricity, LLC Raleigh, orth Carolina USA + 800 8 55 (US toll free) + 99 4800 support@us.elster.com www.elsterelectricity.com *IL4-400Q* 006 by Elster Electricity, LLC All rights reserved. Printed in the United States