Incorrect use or failure of pressure regulators



Similar documents
1805 Series Relief Valves

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

Types 66R and 66RR Low-Pressure Relief Valves

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

289 Series Spring-Loaded Relief Valves

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Recreational Vehicles

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

167D Series Switching Valves

1301 Series High-Pressure Regulators

MODEL LP 225LP2 225LP4 Safety Relief Valves

Commercial & Industrial Propane Regulators and Meters

Pressure Switch for gas and air

OEM-EP Pressure Controllers

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Type 92S Pilot-Operated Steam Regulator

G234X-55 Conventional Gas Boiler

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Compact pressure switch Flameproof enclosure Ex d Model PCA

Type 99 Pressure Reducing Regulator

API Flanged Safety Relief Valves Series 526 CATALOG

Your safety and the safety of others are very important.

Float and Thermostatic Traps Series H, C and X

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Type EZR Relief Valve or Backpressure Regulator

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

08.08 Vic-Check Valves

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

Proportional Relief Valves

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

MODEL J SERIES CONVERTER

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Open Cycle Refrigeration System

VSO MAX HP High Flow Proportional Valve

G9MXE. Product Specifications

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Regulator Options and Accessories

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Troubleshoot resources for homeowner

MAINTENANCE MANUAL LPG CNG INJECTOR RAIL RAIL TYPE 03

ELECTRIC CENTRAL HEATING FLOW BOILER

Propane Catalog Table of Contents. Integral Two-Stage Regulators. Automatic Changeover Regulators & Changeover Manifold Assemblies

Universal Adjustable Fuel Pressure Regulator

PRESSURE REDUCING VALVES

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Automatic Bypass Control AVDO

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

LPM-06 CONVERSION KIT

F9MXE. Product Specifications

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

EZR Series Pressure Reducing Regulator

HeatSource HS1800 Heater

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

Morco House Riverview Road Beverley HU17 0LD

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

Operators manual Basic water heater

MFP14, MFP14S and MFP14SS Automatic Pumps

Model 43AP Pneumatic Controller, Style B

AMX300 DirectConnect Mixing Valve Kits

LP-Gas Serviceman s Manual

SIOUX HYBRID WATER HEATER

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

A/C refrigerant system, overview

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Sizing Pressure Regulators & Control Valves

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Lithichrome Stone Paint- LT Blue Gallon Lithichrome Stone Paint- Blue 2 oz Lithichrome Stone Paint- Blue 6 oz

Cooling Capacity CFM in. w.c. (125 Pa)

Multipurpose Ball Valves

PRESSURE REDUCING CONTROL VALVE

Copper Meter Resetters

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

TY-FLO Needle Valves

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Block and Bleed Gauge Valves M25 and M251

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Before installation it is important to know what parts you have and what the capabilities of these parts are.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Air Eliminators and Combination Air Eliminators Strainers

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Welding Reels HANNAY REELS. For use for: Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5. The reel leader.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Assembly and instructions

Dryaire Desiccant System

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Transcription:

Pressure Regulators Kosan Crisplant is able to offer regulators that may be used in different kind of applications for industrial or domestic use. Pressure regulators are necessary in order to enable the use of the stored or distributed gas for different applications, thereby ensuring the necessary reduction to fit the high for different utilizations. The information on regulators is organised in the following ranges: High Demand First Stage Regulators First Stage Regulators Industrial and Commercial Second Stage Regulators Second Stage Regulators Twin Stage Regulators Adjustable High Pressure Regulators Please bear in mind that in order to select the correct regulator size, the following information is necessary: All flow capacities in the tables are based on specific conditions. For information on capacities in different conditions, please contact us. Incorrect use or failure of regulators may cause dangerous situations such as: High than desired downstream from the regulator Leaks of gas on the regulator Lower than desired downstream from the regulator Damage or accident as consequence of the previous situations The range Kosan Crisplant is offering is complete and matches several specifications and different demands from various markets. Nevertheless, if you do not find what you need on the following pages, we kindly ask you to contact us. We will do our best to provide the best solution for your need. For proper support contact one of the KC offices closest to your location. Inlet Outlet Desired flow Type of gas

High Demand First Stage Regulators High demand first stage regulators are installed as the first stage regulator on gas installations as they are able to reduce the from the 1st stage to an intermediate before utilization (2nd stage). In some cases, this kind of regulators may supply the gas directly to the industrial equipment. By screwing or unscrewing the adjustment spring, or adding several spring ranges, it is possible to set the outlet of the regulator. Part Number Connections (FxF) NPT Orifice Outlet (bar)* Pin (Bar) 627 1 ½ 0.34 to 1.4 13,8 1307 (setpoint 1,4 6,9 778 bar) 3,4 485 2,1 210 046 ¾ 3/8 13,8 434 6,9 288 3,4 242 2,1 148 1 13,8 878 6,9 530 3,4 275 2,1 152 Propane** (kg/ hr) * - For standard spring ** - Capacities based on outlet of 1.4 bar, for butane multiply by 1.064 for Nm 3 /h of NG, multiply by 0,80 OUTLT PRSSUR RGULATION SPRINGS 627 Outlet Bar 046 Outlet Bar range spring range spring Yellow 0,34-1,4 Yellow 0,20-0,69 Green 1,0-2,8 Aluminium 0,55-1,38 Blue 2,4-5,5 White 1,03-3,58 Red 4,8-10,3 Green 0,69-6,55 - - Tan 3,44-8,61 046 627 72

First Stage Regulators These types of regulators are installed as the first stage regulator on LPG installations as they are able to reduce the from the tank or the cylinder (1st stage) to an intermediate before utilization (2nd stage). In some cases, this type of regulators may even supply the gas directly to the industrial equipment which should then be prepared to receive gas flow at high. Some types of regulators are adjusted from the factory without the possibility of changing the outlet, while other types can be user adjusted by screwing or unscrewing the spring. Depending on the model, regulators may have an internal relief valve or/and tap incorporated. RGO Part Number Inlet Outlet Factory Outlet Pressure (bar) Outlet Vent position Integral Relief Included Propane* (kg/hr) LV3403TR 1/4" NPT 1/2" F.NPT 0,69 - Over Outlet YS 31 LV3403TRV9 9:00 LV4403SR4 1/2" NPT 1/2" F.NPT 0,34 0,069 to 0,34 Over Outlet 52 LV4403TR4 0,69 0,34 to 0,69 LV4403SR9 F.POL 0,34 0,069 to 0,34 LV4403TR9 0.69 0,34 to 0,69 LV4403SR96 ¾ F.NPT 0,34 0,069 to 0,34 LV4403TR96 0,69 0,34 to 0,69 * Capacities based on inlet 1.37 bar higher than setting and outlet 20% lower than setting. LV3403 LV4403 73

Industrial and Commercial Second Stage Regulators The industrial and commercial regulators are installed as the second stage regulator on a LPG installation as they are able to reduce the from an intermediate, downstream from a LPG cylinder or a LPG tank, to a utilization. Some types of regulators are adjusted from the factory without the possibility of changing the outlet, while other types can be user adjusted by screwing or unscrewing the spring. Depending on the model, regulators may have an internal relief valve or/ and tap incorporated. 143 243 Part Number OUTLT PRSSUR RGULATION SPRINGS 143-80-2 Outlet colors spring 243-80 Outlet colors spring HSR Outlet range spring Red 9-16 Green 30-70 Yellow 15-20 Blue 13-21 Orange 69-137 Silver 25-31 Green 15-34 Black 137-293 Gray 31-50 Orange 29-68 Cadmium 206-448* Pink 50-87 Black&White 34-138 White 410-690* Light Blue 90-150 Cadmium* 34-206 - - Black* 137-413 - - * - Hp models only Connections (FxF) NPT Orifice Internal Relief Valve Outlet * Pin (Bar) 143-80-2 1 Yes 30-70 1,38 71 (setpoint 0,69 48 xxmbar) 0,52 40 0,34 31 ¾ 1,38 43 0,69 34 0,52 30 0,34 25 243-8-2 1 ½ 70-140 1,70 304 (setpoint 1,03 230 xxmbar) 0,69 183 0,34 113 2 70-140 1,70 353 (setpoint 1,03 247 xxmbar) 0,69 190 0,34 116 HSR 1 1/4 31-50 2.75 107 (setpoint 2,07 95 35mbar) 1,38 76 0,69 47 * - For standard spring ** - Capacities based on outlet of 1.4 bar, for butane multiply by 1.064 for Nm 3 /h of NG, multiply by 0,80 Propane** (kg/ hr) HRS HRS 74

Second Stage Regulators These regulators are installed as the second stage regulator on a LPG installation as they are able to reduce the from an intermediate, downstream from a LPG cylinder or a LPG tank, to a utilization. Some types of regulators are adjusted from the factory without the possibility of changing the outlet, while other types can be user adjusted by screwing or unscrewing the spring. Depending on the model, regulators may have an internal relief valve or/and tap incorporated. RGO Part Number Inlet Outlet Factory Delivery Pressure @0,69 bar inlet Outlet Vent Position Propane (kg/hr) Integral Relief Included LV4403B4 1/2" 2 28 22-33 Inlet 20* Yes - Obs. LV4403B46 3/4" LV4403B46R LV4403B66 3/4" LV4403B66R LV4403B66RA 21* - LV4403B66RAB LV4403H414 1/2" 1/2" 36 31-47 Inlet 14 Yes - LV4403H4614 ¾ LV4403H6614 ¾ LV5504H414 ½ ¾ 34,8 17,4-39,8 35** LV5503H614 ¾ 39,8 LV5504620 49,8 27,3-69,7 LV5503H620V 49,8 Outlet LV5503H640 99,7 69,7-209,3 Inlet LV5503H640V 99,7 Outlet LV5504H814 ¾ 1 34,8 17,4-39,8 Inlet 50** LV5503H820 49,8 27,3-69,7 LV5503H840 99,7 69,7-209,3 LV5503B4 1/2 3/4" 28 22-33 33* LV5503B6 3/4" LV5503B8 3/4" 1" 47* LV6503B14 1 1/2" 21-35 Inlet 165* LV6503B16 2" 200* Backmount design Backmount design Mounting bracket included; 90º connections * Capacities based on 0,69 bar inlet and 22 mbar delivery. ** Capacities based on 0,69 bar inlet and 20% drop of delivery. LV5503B LV4403B 75

Twin Stage Regulators Twin Stage Regulators are compact solutions with the availability of reducing the from LPG tanks or cylinders (1st stage) directly to utilization maintaining the advantages of a two stage regulation system. Internally, they incorporate two different reductions steps instead of only one as normal. Usually, the regulators are user tuned by screwing or unscrewing the spring. Depending on the model, regulators may have an internal relief valve or/ and tap incorporated. RGO Part Number Inlet Outlet Factory Delivery Pressure @6,89 bar inlet Outlet Bonnet Vent Position 1st Stage Bonnet Vent Position 2nd Stage Propane* (kg/hr) Accessories 1st Stage Vent Pipe- Away 2nd Stage Vinyl Cover Bracket LV404B4 ¼ 1/2" F. NPT 28 22 33 Down Outlet 11 404P - - LV404B4V9 9:00 LV404B46 3/4" F. NPT Down Outlet LV404B46V9 9:00 LV404B9 F. POL 1/2" F. NPT Down Outlet LV404B9V9 9:00 LV404B96 3/4 F. NPT Down Outlet LV404B96V9 9:00 LV404B23 ¼ 1/2" F. NPT Rear Outlet 4,5 2302-55 2302-31 LV404B29 F. POL LV404B23V9 ¼ Left 9:00 LV404B29V9 F. POL * Capacities based on 6,89 bar inlet and 22 mbar delivery. LV404B23 LV404B29V LV404B23V9 LV404B9 76

High Pressure Industrial/Commercial Adjustable Regulators Adjustable regulators represent the best solution when it is necessary to work with a wide range of settings on the same device. Regarding the tank or cylinder, this type of regulator is able to adjust the outlet by use of a Tee handle. In order for the operator to adjust the, the regulator normally has a tap for manometer installation. The regulators mentioned below are able to work with liquid or vapor. Downstream or upstream relief valve installation is recommended. Care must be taken to prevent re-liquification of propane at normal temperatures by heat tracing or other effective means. RGO Part Number Adjustment Method Connections Recommended Delivery Pressure (bar) Approx. dimensions (mm) Width between connections (mm) Max. Height (mm) Capacity Determined at Set Pressure of bar* 597FA Tee Handle 1/4" 0,07-1,03 87 143 0,68 37 597FB 0,7-2,07 1,38 63 597FC 1,37-3,10 2,07 73,5 597FD 2,8 7,0 2,76 93 1584MN 1/2" 0,2-2,1 74 124 1,4 145 1584ML 1,7-3,5 2,1 155 1584MH 3,1-8,6 4,1 165 1586MN 3/4" 0,2-2,1 89 178 1,4 227 1586ML 1,7-3,5 2,1 248 1586MH 3,1-8,6 4,1 289 1588MN 1" 0,2-2,1 1,4 227 1588ML 1,7-3,5 2,1 248 1588MH 3,1-8,6 4,1 289 * Set established with 6,89 bar inlet and 5,28 kg/h for 59X series and 10,57 kh/h for 158X series. **Capacity determined at actual delivery 20% less than set with inlet 1,38 bar higher than the set. Capacity Kg/ hr. Propane** 77

Kosan Crisplant a/s P.O. Pedersens Vej 22 DK-8200 Aarhus N Denmark Tel +45 8740 3000 Fax +45 8740 3010 sales@kosancrisplant.com service@kosancrisplant.com www.kosancrisplant.com Worldwide sales of high-quality gas components ProSupply Centre Denmark: Tel +45 8740 3000 ProSupply Centre Portugal: Tel +351 220 938 700 prosupply@kosancrisplant.com www.kosancrisplant.com/prosupply Rev. 0 // March 2013