SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use



Similar documents
QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Digital input modules

RRV934. Multi-controller. Synco living

TX OPEN RS232/485 module

Air damper actuators

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Flush-mount room temperature sensor AQR2531ANW.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Heating Controller. Building Technologies HVAC Products

Input module, input/output module

Flush-mounted room thermostats

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

VAV compact controller KNX / PL-Link

Room Temperature Sensors

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

OZW30. Central Unit SYNERGYR

Duct Humidity Transmitter

Electronic Control Devices The European Product Catalogue 2007

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

PCS0100en Persy Control Services B.V. Netherlands

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

OZW V2.0. Web server. Synco TM, Synco TM living

J TB/TW Temperature limiter, temperature monitor

Product and functional description

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PXM20-E. Operator unit DESIGO PX

HERZ-Thermal Actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

HVAC central apartment unit with consumption data acquisition

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Drayton Digistat +2RF/+3RF

Redundancy Module QUINT-DIODE/40

40.3. Control Relays and Timers

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Safety technique. Emergency stop module BO 5988 safemaster

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MINI MCR-SL-R-UI(-SP)

T0118 T2118 T3118. Instruction Manual

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

VAV compact controller KNX / PL-Link

OZW672...V5.2. Web-Server. For LPB/BSB plants

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Quick Connect. quick - simple - efficient.

How To Control A Korean Korean Power Plant

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

KNX Panasonic Air Conditioners

OZS Web server. For LPB/BSB plants

IntesisBox KNX Modbus TCP master

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

mecotron Safety relay ESTOP-2 For emergency stop monitoring

IntesisBox Modbus Server SAMSUNG Air Conditioners

Adjustable room thermostat for heating only or cooling only systems

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

IntesisBox KNX Modbus RTU master

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

IntesisBox Modbus Server Fidelio IP

Rosemount 333 HART Tri-Loop

Smile. The All-In-One Heating Controller

SYSTEM DESCRIPTION Termination Boards

Electronic overload relay EF19 and EF45

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Voltage Regulator SPAU 341 C. Product Guide

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Actuator-Sensor-Interface

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Installation manual. Generator Paralleling Controller GPC multi-line C

HMI display Installation Guide

Instruction Manual. T3111 T3111L T3111P T3111Ex

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic Control Devices The European Product Catalogue 2007

Three-phase monitoring relay CM-PFE

ACS-30-EU-EMDR-10-MOD

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Emergency lighting units EM powerled

Inductive sensor NI10-M18-Y1X-H1141

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Rosemount 333 HART Tri-Loop

Thyristor-controlled power supplies and battery chargers

Transcription:

s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum selection or averaging of up to 5 passive or active input signals calculate enthalpy, enthalpy differentials, absolute humidity or dew points from passive temperature and active humidity signals convert 1 passive input signal into 2 active signals double signals for the sequential control of pumps, valves and fans CE1N5146en 2016-02-05 uilding Technologies

Functions Universal inputs Function modes Universal inputs for 5 passive or active analog input signals of various measured values ( C, %, ---). inimum / maximum / average (IN-AX-AVR) Selection of maximum input signal from the inputs IN 1 IN 5 Selection of minimum input signal from the inputs IN 1 IN 5 Calculation of average value of the inputs IN 1 IN 5 For calculating the average value, input IN1 can be weighted. This means that, for making the calculation, the number of input signals can be increased several times over If, in addition, configuration parameter SPLIT is activated, the functions will be assigned to the inputs X1 X2 and X3 X5. This means, e.g.: Selection of maximum input signal from the inputs IN 1 IN 2 Selection of maximum input signal from the inputs IN 3 IN 5 Selection of minimum input signal from the inputs IN 1 IN 2 Selection of minimum input signal from the inputs IN 3 IN 5 Calculation of average value of the inputs IN 1 IN 2 Calculation of average value of the inputs IN 3 IN 5 Enthalpy processor (ENTHALPY) Calculation of enthalpy from 1 passive temperature signal and 1 active humidity signal Calculation of absolute humidity from 1 passive temperature signal and 1 active humidity signal Calculation of enthalpy differential from 2 signal groups each delivering 1 passive temperature signal and 1 active humidity signal Calculation of dew point temperature from 1 passive temperature signal and 1 active humidity signal Signal doubling / signal inversion (2X-INV) Signal doubling for the sequential control of pumps, valves and fans Signal conversion from 1 passive temperature signal into 2 active temperature signals The functions can be combined as required by the application. Ordering When ordering, please give name and type reference. The poducts listed under "Accessories" must be ordered as separate items. Product documentation Document type Document number asic Documentation CE1P5146en Instructions set (mounting, commissioning, operation) 74 319 0425 0 Declaration of Conformity (CE) CE1T5146xx Environmental Declaration CE1E5146en 2/10

Technical design The signal converter has 13 applications ready programmed. When commissioning a plant, the relevant basic type must be entered. All associated functions, terminal assignments, settings and displays will then automatically be activated, and parameters not required will be deactivated. In addition, 1 empty application (basic type ) is loaded. With the help of the built-in operation or the OCI700.1 service tool, the signal converter offers the following choices: Activation of a preprogrammed application (refer to "Preprogrammed standard application") odification of a preprogrammed application Free configuration of applications For operating actions of the functions, refer to the asic Documentation. echanical design The signal converter consists of terminal base and insert with built-in operation. The terminal base can be fitted to a DIN mounting rail or is screwed directly on a flat surface. It consists of a plastic housing with 2 terminal levels. The insert engages in the terminal base. It consists of a plastic housing which accommodates the printed circuit boards. Controller operation is fully integrated. Operating, display and connecting elements 5146Z01 1 2 3 4 9 8 7 6 5 Legend 1 OK button for confirming the selected menu line or the value entered 2 Navigation button, upward (+) for selecting the menu line or changing the value 3 Navigation button, downward ( ) for selecting the menu line or changing the value 4 ESC button for returning to the previous menu or rejecting the value entered 5 Connection facility for the service tool (RJ45 connector) 6 Display 7 Catch for fitting the signal converter to a top hat rail 8 Fixing facility for a cable tie (cable strain relief) 9 Rest for the terminal cover Accessories Name ounting frame for flush panel mounting (consisting of 1 small frame, 1 large frame, 2 hexagonal spacers, 4 fixing screws, ounting Instructions) Type reference AR62.201 3/10

Engineering notes ounting and installation notes You have to use an external supply line protection with a slow fuse of max. 10 A or a circuit breaker of max. 13 A with the characteristic, C, D according to EN 60898 or a power source with current limitation of max. 10 A. Fuses, switches, wiring and earthing must be in compliance with local regulations Sensor wires should not be run parallel to mains carrying wires that power fans, actuators, pumps, etc. It is recommended to use the standard applications provided (refer to "Preprogrammed standard applications"). Specific plant situations may require certain adaptations however The signal converter is designed for: ounting in a standard cabinet to DIN 43 880 Wall mounting on an existing top hat rail (to EN 50 022-35x7.5) Wall mounting using 2 fixing screws Flush panel mounting with AR62.201 mounting frame Not permitted are wet or damp spaces. The permissible environmental conditions must be observed Disconnected the system from power supply prior to mounting the signal converter The insert may not be removed from the terminal base! Each terminal (spring cage terminal) can accommodate only 1 solid wire or 1 stranded wire. For making the connections, the cables must be stripped for 7 to 8 mm. To introduce the cables into the spring cage terminals and to remove them, a screwdriver size 1 is required. Cable strain relief can be provided with the help of the fixing facility for cable ties The signal converter is supplied complete with Installation Instructions and Operating Instructions Commissioning notes The configuration and parameters of the standard applications offered by the controller can be changed any time by service staff who have been trained by HVAC Products and who have the required access rights, either locally or online/offline with the service tool During the commissioning process, the application is deactivated and the outputs are in a defined off state On completion of the configuration, the signal converter automatically makes a new start When leaving the commissioning pages, the peripheral devices connected to the universal inputs are automatically tested and identified. If a peripheral device is missing, a fault status message will be delivered If adaptations to specific plants are required, they must be recorded and the documentation kept inside the control panel For the procedure to be followed when starting up the plant for the first time, refer to the Installation Instructions 4/10

Disposal notes The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the devices through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical data Power supply (, ) Operating voltage Frequency Power consumption External supply line protection AC 24 V 20 % (SELV) 50/60 Hz 5 VA Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic, C, D according to EN 60898 or Power source with current limitation of max. 10 A Universal inputs easured value inputs (X1...X5) Outputs Positioning outputs (Y...) Number 5 Signal sources Passive L-Ni 1000, T1, Pt 1000, 0...1000 2x L-Ni 1000 (averaging) Acteiv Number 2 Output voltage Output current 1 ma ax. load continuous short-circuit Power supply external devices (1) Interfaces Perm. cable lengths Electrical connections Degrees of protection Voltage Current Service tool connection facility For passive measuring and positioning signals Type of signal L-Ni 1000, T1 Pt 1000 0...1000 For measuring and control signals Connection terminals For wires For stranded wires without ferrules For stranded wires with ferrules Degree of protection of housing to IEC 60 529 Safety class to EN 60 730 AC 24 V max. 4 A RJ45 connector (measuring errors can be corrected) max. 300 m max. 300 m max. 300 m refer to Data Sheet of the signal delivering device spring cage terminals 0.6 mm dia...2.5 mm 2 0.25...2.5 mm 2 0.25...1.5 mm 2 IP 20 (when mounted) device suited for use with equipment of safety class II 5/10

Ambient conditions Operation to Climatic conditions Temperature (housing and electronics) Humidity echanical conditions Transport to Climatic conditions Temperature Humidity echanical conditions IEC 60 721-3-3 class 3K5 0...50 C 5...95 % r.h. (non-condensing) class 32 IEC 60 721-3-2 class 2K3 25... 70 C <95 % r.h. class 22 Classifications to EN 60 730 aterials and colors Standards, directives and approvals Environmental compatibility ode of operation, automatic controls type 1 Degree of contamination, controls environment 2 Software class A Rated surge voltage 4000 V Temperature for ball-pressure test of housing 125 C Terminal base Polycarbonate, RAL 7035 (light-grey) Controller insert Polycarbonate, RAL 7035 (light-grey) Packaging corrugated cardboard Product standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commerce, light-industrial and industrial environments EU conformity (CE) CE1T5146xx *) EAC conformity Eurasia conformity UL certification (US) UL 916, http://ul.com/database The Product environmental declaration contains CE1E5146en *) data on RoHS compliance, materials composition, packaging, environmental benefit and disposal. *) The documents can be downloaded from http://siemens.com/bt/download. Weight Excl. packaging 0.293 kg 6/10

Connection diagrams Internal diagram X1 X2 1 X3 X4 1 X5 51461 1 1, Rated voltage AC 24 V 1 Output voltage AC 24 V for powering external active sensors easuring neutral for signal input System neutral for signal output X... Universal signal inputs (analog signals only) for L-Ni 1000, 2x L-Ni 1000 (averaging), T1, Pt 1000,, 0...1000 Y... Control or status outputs, analog Note Each terminal (spring cage terminal) can only accommodate 1 solid wire or 1 stranded wire. Double terminals are internally interconnected. Connection diagrams Connection of 2 passive sensors on the input side (averaging) 5.1 L-Ni 1000 5.2 L-Ni 1000 5146A06 AC 24 V X... U2 U2 5... Signal converter SEZ220 Room temperature sensor QAA24 For other connections on the input and output side, refer to " Preprogrammed standard applications ". Dimensions SEZ220 10,5 ø 86 44 5 3 3 35 ø 5 50 44,5 EN 60 715-TH 35-7.5 123 = = 97 514601 3 3 2 = = 66,4 90 7/10

AR62.201 ounting frame 113 143 5146103 5,6 45 87 24 Panel cutout if controller shall be wired prior to mounting: Panel cutout if controller shall be wired after mounting: 107 514605 4,4 45 10,7 18 4,4 97 133 4,4 66,4 514604 82 45 18,5 18 4,4 97 133 107 7,8 66,4 Dimensions in mm Preprogrammed standard applications Notes The connection diagrams assigned to the basic types are only examples. asic type Description Connection diagram 01 Selection of minimum and maximum input signal from all present passive input signals 5 x L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 IN AX 8/10

asic type Description Connection diagram 02 Selection of maximum input signal and calculation of average of all present passive input signals 5 x L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 AVR AX 03 Selection of maximum input signal and calculation of average of all present active input signals 5 x X1 X2 1 X3 X4 1 X5 1 1 AVR AX 04 Selection of minimum input signal from 2 active input signals and 3 passive input signals 2 x 3 x L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 IN IN 05 Calculation of average of 2 active input signals and 3 passive input signals 2 x 3 x L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 AVR AVR 06 Selection of maximum input signals from 2 active input signals and 3 passive input signals 2 x 3 x L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 AX AX E01 Calculation of enthalpy from 1 passive temperature signal and 1 active humidity signal L-Ni 1000 L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 ENTH 1 [kj/kg] ENTH 2 [kj/kg] E02 Calculation of enthalpy differential from 2 signal groups each with 1 passive temperature signal and 1 active humidity signal L-Ni 1000 L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 ENTH D [kj/kg] 9/10

asic type Description Connection diagram E03 Calculation of absolute humidity and enthalpy from 1 passive temperature signal L-Ni 1000 and 1 active humidity signal X1 X2 1 X3 X4 1 X5 1 1 E04 Calculation of absolute humidity from 1 passive temperature signal and 1 active humidity signal ASHU 1 [g/kg] L-Ni 1000 ENTH 1 [kj/kg] L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 ASHU 1 [g/kg] ASHU 2 [g/kg] E05 Calculation of dew point from 1 passive temperature signal and 1 active humidity signal L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 DEWPNT [ C] D01 Doubling of signal for sequential control of pumps, valves and fans DC 0... 10 V X1 X21 X3 X4 1 X5 N1 1 1 U2 Legend N1 = Controller (or active device) U2 = SEZ220 signal converter 0 V 5 V 10 V X1 0 V 5 V 10 V X1 D02 Signal conversion from 1 passive temperature signal into 2 active signals L-Ni 1000 X1 X2 1 X3 X4 1 X5 1 1 2 x X1 0 C 50 C X1-35 C +35 C Published by: Siemens Switzerland Ltd. uilding Technologies Division International Headquarters ubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2004 Delivery and technical specifications subject to change 10/10