KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems



Similar documents
Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus KNX IP Router IPR/S 2.1

EIB/KNX IP Interface with Power over Ethernet (PoE)

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

KNX IP Interface. Operating and installation manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices

Application program usage. Functional description. Note. Note. instabus EIB Application Program Description. August CO IP-Interface

IN00A01IPI. Hardware specification KNX IP INTERFACE IN00A02IPISH IN00A02IPISH Specifica N. Progetto N. Titolo del progetto

Follow these steps to prepare the module and evaluation board for testing.

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

SNMP Web Management. User s Manual For SNMP Web Card/Box

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Vocia MS-1 Network Considerations for VoIP. Vocia MS-1 and Network Port Configuration. VoIP Network Switch. Control Network Switch

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

IntesisBox KNX Modbus TCP master

1 Serial RS232 to Ethernet Adapter Installation Guide

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

User Manual. EtherUSB

On the M-BUS Interface you can add up to 60 M-BUS Devices (60 unit loads).

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

HWg-STE HWg-STE PoE MANUAL

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Push button 3gang standard flush-mounted xx

connecdim Gateway G1 Ethernet TCP/IP to DALI

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Energy Communication Unit (ECU)

User Manual. EtherUSB

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

PRONET WEB SERVER. INSTRUCTIONS FOR INSTALLATION AND USE English. Version 01/15 Ident no

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Application & Quick-Start Guide

YO-301AP POE AP Datasheet

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Waveguide Access Point WGA631. Product Guide

PCS0100en Persy Control Services B.V. Netherlands

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Users manual. TCW181B-CM_R1 Page 1

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

R70 Ethernet to CAN interface Software reference manual (1.3 EN)

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

ABB i-bus KNX Fan Coil Controller FC/S 1.1

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Inwall 4 Input / 4 Output Module

LBNP RS-232/485/422 serial device server. User manual

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

How to put the DVR online

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Network Power Manager. User Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual

Application Unit, MDRC AB/S 1.1, GH Q R0111

Ha-VIS FTS 3000 Introduction and features

IntesisBox KNX LG Air Conditioning

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Energy Communication Unit (ECU)

User Manual Revision English

Quick Installation Guide of WLAN Broadband Router

(IR) Bullet LPR/ANPR Network Camera

ProSAFE 8-Port and 16-Port Gigabit Click Switch

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

Broadband Router ESG-103. User s Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Networking Guide Redwood Manager 3.0 August 2013

Inwall Room Temperature Unit

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

USER GUIDE. Web Interface

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Wi-Fi EOC Slave Quick Start Guide

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

KNX Interface. User Manual PM00A00IRI

Terminal and Dimension

instabus EIB Manual February 2004 Table of Contents

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

IntesisBox KNX Mitsubishi Heavy Industries AC

Welcome. Unleash Your Phone

Wifi Pan/Tilt IP Camera User Manual

C9 HD Video Conference Terminal

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Light scene push button 8gang comfort flush-mounted xx

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

User guide for NANOSTATION 2

NeoGate TA Series Installation Guide

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

CP Page 1342 Mar 2008 Siemens ITS

Setting up IP address distribution in a LAN

Transcription:

KNX Gateway Light-Control R User manual-ver.1 LC-IPGW-001 Intelligent Installation Systems

Contents 1. Summary --------------------------------------------------------------------------------------------------------------------- 3 2. Technical Properties & Dimension and Circuit Diagram---------------------------------------------------- 3 2.1 Technical data -------------------------------------------------------------------------------------------------------- 4 2.2 Dimension diagram -------------------------------------------------------------------------------------------------- 5 2.3 Circuit diagram ------------------------------------------------------------------------------------------------------- 5 3. Parameter setting description in the ETS ------------------------------------------------------------------------- 6 3.1 Parameter window IP settings --------------------------------------------------------------------------------- 6 3.2 Parameter window IP address --------------------------------------------------------------------------------- 7

1. Summary The KNX IP Interface is designed for an intelligent building control system, which is used for facilitating communication between the Ethernet network and the KNX system. The KNX IP Interface connects the EIB/KNX system with the Ethernet network via an Ethernet RJ45 interface in the front,it serves as an interface between KNX installations and IP networks and can configure, parameterize and commission the EIB/KNX installation as well as bus monitor via the LAN using the ETS (ETS3 or later) software. For operation an additional 30V DC supply is necessary. The bus connection and auxiliary power supply connection are carried out via using EIB bus connection terminals. The device adopts an Ethernet RJ45 interface to connect with LAN network. The network interface can be operated with a transmission speed of 10/100Mbit/s Auto Sensing. The IP address of the device can be fixed or can be received from a DHCP server. If you need to remain the IP address static or here no DHCP server on the network, you can assign a fixed IP address to the device via ETS. The application program is preloaded in the factory, the IP address is fixed, and the port number is set to 3671. (Note: the device cannot program itself, but need via other communication interface device to program it.) The KNX IP Interface is able to use the Engineering Tool Software ETS (ETS3 or later) with a VD4 file to allocate the physical address and set the parameter. The factory default physical addresses are 15.15.255, and the address can be modified directly via local interface settings of ETS. The KNX IP Interface is a modular installation device. It can be installed in the distribution board on 35mm mounting rails according to EN 60 715. This manual provides the technical information about the KNX IP Interface as well as assembly and programming in detail for users, and explains how to use the interface device by the application examples. 2. Technical Properties & Dimension and Circuit Diagram

2.1 Technical data Power supply Operation voltage 21-30V DC, via the EIB bus Current consumption, EIB Power consumption, EIB Auxiliary power supply Auxiliary power consumption <12mA <360mW 20-30V DC <2.5W Connections EIB / KNX Via bus connection terminal (black/red) Operating and display External power supply LAN Programming LED and button LED Green flashing LAN LINK LED ON LAN LINK LED flashing EIB LINK LED ON EIB LINK LED flashing Via bus connection terminal (grey/yellow) RJ45 socket for10/100base-t, IEEE 802.3 network, Auto Sensing For assignment of the physical address The device running indicator Network connection indicator Telegram traffic between the device and network KNX bus connection indicator Telegram traffic between the device and KNX bus Temperature Operation 5 C... + 45 C Storage 25 C... + 55 C Transport 25 C... + 70 C Ambient Humidity <93%, except condensation Design Dimensions Weight Housing, colour Modular installation device, on 35mm mounting rail 90 mm 36 mm 64mm 0.1KG Plastic housing, grey Application program Max. number of Max. number of Max. number of communication objects group address associations

2.2 Dimension diagram 2.3 Circuit diagram 1 LAN LINK ON, indicate that network connect normally. LAN LINK flashing, indicate that telegram traffic is ongoing. Network activity is indicate by the LED

2 EIB LINK ON, indicate that KNX bus connect normally. EIB LINK flashing, indicate that telegram traffic is ongoing, which is indicate by the LED 3 Auxiliary power supply connection 4 LAN connection, 5 Programming LED, LED red light up for assignment of physical address, LED green flashes for indicator of the device running normally. 6 Programming button 7 EIB /KNX bus connection 3. Parameter setting description in the ETS 3.1 Parameter window IP settings Parameter window IP setting is shown in fig. 3.2. Because IP Interface and RS485 converter use the same product database, so before setting IP Interface parameters, you must select devices first, as follow (fig.3.1): Fig 3.1 Choose device Fig.3.2 parameter window IP settings

Parameter Device name (Max. 30 Char.), If first char. = A or a use DHCP The parameter defines the name of the IP Interface to identify the device on the LAN. Here can entry a maximum of 30 characters in length. The follow points apply for setting: If the first character is A or a, the device will work in DHCP mode, and can get an IP address automatically from network. And the character will not disappear in the device s name. If the first character is F or f, the IP address of the device need set by manual. And the character will not disappear in the device s name. For example: If your device name is Family, and you want to use DHCP mode, Input string AFamily. If you want to use Fix mode, Input string FFamily. If your device name is Audio, and you want to use DHCP mode, Input string is AAudio. If you want to use Fix mode, Input string is FAudio. If you input Audio, then the device name is udio, and use DHCP mode. If your device name is start with another character, you can input the device name directly, with Fix IP address mode, without with the F or f start. If you want to use DHCP mode, you only add A or a at ahead of your device name. Parameter IP address assignment (Don t use it if DHCP) The parameter indicates that the IP address assignment of the Interface is fixed if the DHCP mode is not used. If the DHCP mode is used, the parameter is invalid. The fixed IP address can be assigned in the follow parameter window IP address, see fig. 3.3. Parameter If you use private protocol, the port is The parameter is invalid for the IP interface. The port number of IP interface is set to 3671. If you use private protocol, the port number can be set via the parameter, but the device will be used as a convertor, instead of KNX IP Interface. See also the product BTIC-01/00.1. When the device is used as a convertor, its function is same with the BTIC-01/00.1. The parameter defines the port number of the convertor, the port number of client devices must be same with the convertor, or else their communications will fail. 3.2 Parameter window IP address Parameter window IP address is shown in fig. 3.3. Here set network connection information, such as IP address, Subnet mask and Default gateway. If the IP Interface use DHCP mode, the parameters are invalid in the window.

Fig 3.3 parameter window IP address Parameter IP address The parameter defines the IP address of the IP Interface, the IP address is unique on the LAN, to avoid collide. Option: Byte x: 0 255 The IP address should be entered in a byte-by-byte manner, e.g. as follows for address 192.168.1.10: Byte1: 192 Byte2: 168 Byte3: 1 Byte4: 10 Parameter Subnet mask The parameter defines the subnet mask of the IP Interface. The subnet mask must be set to reflect the number and structure of the subnet. Option: Byte x: 0 255 In a small network the subnet mask 255.255.255.0 should be set as follows: Byte1: 255

Byte2: 255 Byte3: 255 Byte4: 0 Parameter default gateway The parameter defines the default gateway. The default gateway must be the same network segment with the IP address. Option: Byte x: 0 255 The default gateway 192.168.1.1 should be set as follows: Byte1: 192 Byte2: 168 Byte3: 1 Byte4: 1