Wahl C50 Calibrator FEATURES



Similar documents
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Hand-held thermometer Model CTH7000

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

4-Channel Thermometer / Datalogger

Loop Calibration and Maintenance

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

DC Electronic Loads 8500 series

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Multifunction Process Calibrator

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Analog signal converters CC-E I/I Current / current isolators

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

DPI 260 SERIES: Digital Pressure Indicators

Duct Humidity Transmitter

Multi-Range Programmable DC Power Supplies 9115 Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Preset Counter signo 721

Dual Laser InfraRed (IR) Thermometer

NI USB-5681 RF Power Meter Specifications

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Series DFMT Digital Paddlewheel Flowmeter

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

O C M III. Open Channel Flow Monitor

Current Monitoring Kit

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Advanced Systems Tester 900AST

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

AutoRanging Digital MultiMeter

Signal Conditioning Amplifier System

T0118 T2118 T3118. Instruction Manual

USB-500 Series Stand-Alone, Low-Cost Data Loggers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic Pressure Switch EDS 300

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Multifunction devices

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

M 140i. Multifunction Calibrator. Operation Manual

Transmitter Interface Program

Problem / Solution. The problem:

Fluke 3000 FC Series Test Tools Technical Data

High Power Programmable DC Power Supplies PVS Series

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

User's Guide. True RMS Industrial Multimeter

Process Tools Selection Guide. inside for: for industrial instrumentation and electrical technicians. Loop Calibrators. Pressure Calibrators

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Contents. Document information

Long Distance Industrial Wireless Transmitters and Receivers

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Multi-Range Programmable DC Power Supplies 9115 Series

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

2002 IS Catalog. Page

Test equipment for temperature and its reduction

NEW. EVEN MORE data acquisition and test stand automation

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

V350-TA24 V350J-TA24.

FREJA 300 Relay Testing System

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Agilent 8904A Multifunction Synthesizer dc to 600 khz

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Voltech DC1000. Precision DC Bias Current Source

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Agilent 4339B/4349B High Resistance Meters

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

USB Smart Power Sensor

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB Smart Power Sensor

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

FREQUENCY RESPONSE ANALYZERS

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

KONSTANTER SPL / SPL Programmable Electronic Load

SINEAX U553 Transducer for AC Voltage

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Quick Connect. quick - simple - efficient.

U1602A Handheld Oscilloscopes, 20 MHz

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Transcription:

NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply, USB Connectors Alphanumeric Keyboard Wide backlit Screen Protected by a Polycarbonate Membrane Designed in close collaboration with industrial users, the integrates all the necessary functions for calibration and maintenance of processes. Its ergonomic design and embedded software make the an easy to use high performance calibrator. IP 54 rated and fully protected by an anti-shock boot, with integrated quick connect terminals and a high-contrast backlit display, it is comfortable to use in all conditions. Its elastomer keypad protects it from dirt and grease marks, and the raised keys allow the to be used with gloves. It has 10 user programmable configurations for repetitive jobs. Display: Backlit display with contrast settings USB Connection/Rechargeable NiMH Batteries Recommended Ambient Conditions: 0 to 50 C, 10 to 80% Relative Humidity Maximum Ambient Conditions: -10 to 55 C, 10 to 80% Relative Humidity Protection Rating: IP54 Weight/Dimensions: 7 oz (200g); 8.3 x 4.3 x 2.0 inches (210 x 110 x 50mm) FEATURES The is a portable calibrator able to measure and generate simultaneously on 2 isolated channels. It has a wide high-contrast backlit display for use in low ambient light conditions. Fully protected by the anti-shock boot, a lexan window and polycarbonate membrane keypad are resistant to dirt. The raised numerical keys are usable even when using protective gloves. The is able to measure and generate voltage, current, and resistance signals, temperature by resistive probes and thermocouples, and frequency for frequency signals and dry contacts. 1

Functions and Performances QUICK CONNECT SYSTEM: FUNCTIONS and PERFORMANCES This unique system is used by pressing down on the top of the terminal, inserting bare wires up to 3mm in diameter or compensated thermocouple connectors, and then releasing. Additionally, standard 4mm Banana Plugs or Safety Plugs can be inserted on the front panel. Thermocouple wires and connectors are held tight between 2 brass plates which provide excellent cold junction compensation. DISPLAY RESOLUTION: comes with user selectable resolution for those users who prefer less resolution, or want to simplify noncritical measurements. FUNCTIONS: The allows the following physical values to be measured and simulated: Voltage Temperature by resistive probes and thermocouples Current Frequency for frequency signals and for dry contacts Resistance It is able to perform scaling of process signals and temperature probe correction. It is compatible with HART transmitters by inserting a 250 ohms resistance, without disturbing digital data transfer. DISPLAY: s dual display simultaneously indicates the measurement value, the emitted value, the gauge, and the used functions. On the top line the date, time and external temperature are also indicated. During measuring, Average, Maximum, Minimum and the number of measurements are displayed on the left. During emission this part of screen displays all details of ramps, steps and constant value emission functions. Drop-down menus are used with the navigator, and on-line help is available to make connections of probes and wires easier. 2

Functions and Performances Functions and performances: @23 C ±5 C DC Current: Measurement The is able to measure up to 50mA, with or without power supply of loop (24V power supply). ±50mA 1µA 0.018%R + 2µA Rin < 25 Ω For measurements of transmitters outputs, special ranges give a dual display using ma and % of full scale. also provides linear or quadratic signals. In current measurement Hart compatibility can be selected to measure currents coming from Hart protocol transmitters. DC Voltage: Measurement ±100mV 1µV 0.013%R + 3µV Rin > 10 M Ω ±1V 10µV 0.013%R + 20µV Rin > 10 M Ω ±10V 100µV 0.015%R + 200µV Rin = 1M Ω ±50V 1mV 0.015%R + 2mV Rin = 1M Ω Rin: input resistance Frequency and Counting: Measurement 20kHz < 0.01Hz 0.005%R Threshold triggering: 1V. Unit scale: pulse/min or Hz. Measurement on frequency signal and on dry contacts. Measurement for counting will be done on defined time or on infinite time. Resistance Measurement: 400 Ω 1 m Ω 0.012% R+ 10 m Ω Measurement current 4000 Ω 10 m Ω 0.012% R+ 100 m Ω = 0.25mA 2, 3 or 4 wires resistance measurement: automatic recognition of number of connected wires, indicated on screen. DC Current: Emission 24mA 1µA 0.018%R + 2µA Emission with or without loop supply (24V). Preprogrammed Steps 0% 25% 50% 75% 100% 4-20mA linear 4 8 12 16 20 0-20mA linear 0 5 10 15 20 4-20mA quad 4 5 8 13 20 0-20mA quad 0 1.25 5 11.25 20 4-20mA values 3.8-4 - 4.2 12 19-20 - 21 DC Voltage: Emission 100 mv 1µVΩ 0.013% R+ 2µV Load 1K Ω 2V 10µVΩ 0.013% R+ 20µV Load 2K Ω 20V 100µV 0.015% R+ 200µV Load 4K Ω Frequency and Pulses: Emission 1000Hz < 0.01Hz 0.005% R 10kHz 10Hz 0.005% R Unit scale: pulse/min or Hz. Pulse emissions. Dry contact simulation. Max amplitude: 20V selectable by user. Resistance: Emission 400 Ω 10 m Ω 4000 Ω 100 m ΩΩ 0.014% R + 30 m Ω 0.014% R + 300 m Ω I ext from 0.1 to 10mA I ext from 0.01 to 0.1mA Resistance emission: establishing time < 1ms for compatibility with smart transmitters type. 3

Temperature Specifications RESISTIVE PROBES: MEASUREMENT & EMISSION Probe Type Range Resolution Measurement Accuracy/1Yr Measurement Resolution Emission Accuracy/1 Yr Emission Pt 50 (α = 3850) -220 C + 1200 C 0.01 C 0.012% L + 0.06 C 0.03 C 0.014% L + 0.18 C Pt 100 (α = 3850) -220 C + 1200 C 0.01 C 0.012% L + 0.02 C 0.014% L + 0.12 C JPt 100 (α = 3916) -200 C + 510 C 0.01 C 0.012% L + 0.02 C 0.014% L + 0.12 C Pt 100 (α = 3926) -210 C + 850 C 0.01 C 0.012% L + 0.02 C 0.014% L + 0.12 C Pt 200 (α = 3851) -220 C + 600 C 0.01 C 0.012% L + 0.12 C 0.014% L + 0.33 C Pt 500 (α = 3850) -220 C + 1200 C 0.01 C 0.012% L + 0.07 C 0.03 C 0.014% L + 0.18 C Pt 1000 (α = 3851) -220 C + 1200 C 0.01 C 0.012% L + 0.02 C 0.014% L + 0.08 C Ni 100 (α = 618) -60 C + 180 C 0.01 C 0.012% L + 0.03 C 0.01 C 0.014% L + 0.08 C Ni 120 (α = 672) -40 C + 205 C 0.01 C 0.012% L + 0.03 C 0.01 C 0.014% L + 0.08 C Ni 1000 (α = 618) -60 C + 180 C 0.01 C 0.012% L + 0.03 C 0.01 C 0.014% L + 0.08 C Cu 50 (α = 427) -70 C + 150 C 0.012% L + 0.18 C 0.01 C 0.014% L + Cu 50 (α = 428) -50 C + 150 C 0.01 C 0.012% L + 0.06 C 0.03 C 0.014% L + 0.15 C Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Temperature coefficient: < 10% of accuracy / C. The accuracy in table above is given for a sensor connection in 4 wires THERMOCOUPLES: MEASUREMENT Above specifications are for the meter only, and do not include specific sensor or implementation error. Measurement current: 0.01mA to 1mA Establishing time: <1ms for simulation (simulation on quick transmitters) THERMOCOUPLES: EMISSION Sensor Range Resolution Accuracy/1Yr OUT Range Resolution Accuracy/1Yr K T J E R S B -200 C to -120 C 120 C to -0 C +0 C to 1372 C -200 C to -120 C -120 C to -50 C -50 C to +400 C -210 C to -120 C -120 C to -0 C +0 C to +1200 C -200 C to -100 C -100 C to -0 C +0 C to +1000 C -50 C to +150 C +150 C to +550 C +550 C to +1768 C -50 C to +150 C +150 C to +550 C +550 C to +1768 C +400 C + 900 C +900 C + 1820 C 0.70 C 0.09 C 0.013% R + 0.07 C 0.45 C 0.15 C 0.07 C 0.013% R + 0.013% R + 0.35 C 0.013% R + 0.013% R + 0.013% R + 0.4 C 0.013% R + -240 C to -50 C -50 C to -0 C +0 C to 1372 C -240 C to -100 C -100 C to -0 C +0 C to +400 C -210 C to -0 C +0 C to +1200 C -240 C to -100 C -100 C to +40 C +40 C to +1000 C -50 C to +350 C +350 C to +900 C +900 C to +1768 C -50 C to +120 C +120 C to +450 C +450 C to +1768 C +400 C + 850 C +850 C + 1820 C 0.60 C 0.40 C 0.20 C 0.013% R + 0.07 C 0.013% R + 0.013% R + 0.20 C 0.8 C 0.013% R + 0.013% R + 0.4 C 0.013% R + U -200 C to 660 C 0.15 C -200 C to 600 C 0.15 C L -200 C to 900 C -200 C to 900 C C -20 C + 900 C -20 C + 900 C +900 C + 2310 C 0.013% R + 0.15 C +900 C + 2310 C 0.013% R + 0.15 C -240 C to -190 C -240 C to -190 C 0.3 C N -190 C to -110 C 0.15 C -190 C to -110 C 0.15 C -110 C to -0 C 0.08 C -110 C to -0 C 0.08 C +0 C to 1300 C 0.013% R + 0.06 C +0 C to 1300 C 0.013% R + 0.06 C Platinum -100 C to +1400 C 0.3 C -100 C to +1400 C 0.3 C Mo 0 C to +1375 C 0.013% R + 0.06 C 0 C to +1375 C 0.013% R + 0.06 C NiMo/NiCo -50 C to +1410 C 0.013% R + 0.30 C -50 C to +1410 C 0.013% R + 0.30 C Accuracy is warranted for reference junction (RJ) at 0 C With use of internal RJ (except couple B) add an additional uncertainty of 0.3 C CJC localization is selected by keypad programming, except for thermocouple B: External at 0 C, internal (temperature compensation of instrument s terminals) or by temperature programming Temperature coefficient: < 10% of accuracy / C. Display unit: C and F 4

Additional Functions ADDITIONAL FUNCTIONS FILE MENU: User can save up to 10 full configurations of the instruments and recall them as desired. Configurations can be saved and recalled in function of user and of use. Configurations include all programming done on instrument, as the range. RAMPS GENERATION: Starting, ending and length time values of simple or cyclic ramps can be set to do simulation. Number of ramps can also be adjusted in case of cyclic ramps for any signals. CONTRAST ADJUSTMENT: Screen s contrast can be adjusted as desired to fit with measurement environment. SCREEN BACKLIGHTING: Time of backlighting can be programmed to save battery. BATTERY LIFE: Battery Life is 5-10 hours depending on which Function is selected. SCALING: In measurement and simulation, scaling allows process signals to be displayed in % of FS or in all other units. This function also allows sensors to be corrected after a calibration. STEPS SIMULATION: Program mode: Starting value, number of steps and the duration of step. Manual mode: User has approximately one hundred preset values. In current simulation, user will have some additional preset values in function of range and according to 0%, 25%, 50%, 75% and 100% from selected gauge. Choice is done between gauges: 0-20mA: linear or quadratic 4-20mA: linear or quadratic SYNTHESIZER: With 100 values manually set, the allows curve generation to be remade. 100 user settable values allow complex curves to be generated. RELATIVE MEASUREMENT: Programming of a reference value different from the one of the instrument (NUL function). Subtracting of constant value by measuring or programming it from a measured value (TARE function). TRANSMITTER FUNCTION: is able to be used as a transmitter. Measurement input is copied on the output with scaling. i SQUARE ROOT: In current measurement and simulation, this function takes into account a quadratic signal coming from transmitter of type P. STATISTICAL FUNCTIONS: Average, Minimum, Maximum and also number of measurements done are always displayed. Reset key allows values to be updated. INCLUDED: is supplied standard with 6 testing leads with crocodile clips, a quick battery charging system, neck strap, and stand for desktop use, User Manual on CD Rom, attache style professional carrying case, and NIST Calibration Certificate. SIMULATION MENU: Simulation value is set by entering value on keypad or by changing the appropriate digit with the cursor. 5