Cylindrical Inductive E2A Single Distance High quality for extra long life in daily use wide portfolio range through modular concept designed and tested for extra long life IP67 and IP69k for highest protection in wet environments continuously high quality level through specialized manufacturing process DC -wire and DC 2-wire models Normally open (NO), normally closed (NC) and antivalent (NO+NC) models Stainless steel and brass housings Pre-wired versions with different cable materials and diameters, and M2 types, pre-wired types with cable end s Ordering Information DC -wire models (NO + NC: DC -wire) *2 Size Connection Body material Thread length (overall length) Output configuration Operation mode NO Operation mode NC Pre-wired 27 (0) 9 (62) PNP E2A-S08KS0-WP-B 2M E2A-S08KS0-WP-B2 2M NPN E2A-S08KS0-WP-C 2M E2A-S08KS0-WP-C2 2M PNP E2A-S08LS0-WP-B 2M E2A-S08LS0-WP-B2 2M NPN E2A-S08LS0-WP-C 2M E2A-S08LS0-WP-C2 2M Shielded.5 mm M2 (-pin) 27 () 9 (65) 27 (9) 9 (6) PNP E2A-S08KS0-M-B E2A-S08KS0-M-B2 NPN E2A-S08KS0-M-C E2A-S08KS0-M-C2 PNP E2A-S08LS0-M-B E2A-S08LS0-M-B2 NPN E2A-S08LS0-M-C E2A-S08LS0-M-C2 PNP E2A-S08KS0-M5-B E2A-S08KS0-M5-B2 NPN E2A-S08KS0-M5-C E2A-S08KS0-M5-C2 PNP E2A-S08LS0-M5-B E2A-S08LS0-M5-B2 NPN E2A-S08LS0-M5-C E2A-S08LS0-M5-C2 (-pin) Pre-wired Stainless steel* 27 (9) 9 (6) 27 (0) 9 (62) PNP E2A-S08KS0-M-B E2A-S08KS0-M-B2 NPN E2A-S08KS0-M-C E2A-S08KS0-M-C2 PNP E2A-S08LS0-M-B E2A-S08LS0-M-B2 NPN E2A-S08LS0-M-C E2A-S08LS0-M-C2 PNP E2A-S08KN02-WP-B 2M E2A-S08KN02-WP-B2 2M NPN E2A-S08KN02-WP-C 2M E2A-S08KN02-WP-C2 2M PNP E2A-S08LN02-WP-B 2M E2A-S08LN02-WP-B2 2M NPN E2A-S08LN02-WP-C 2M E2A-S08LN02-WP-C2 2M Nonshielded 2.0 mm M2 (-pin) 27 () 9 (65) 27 (9) 9 (6) PNP E2A-S08KN02-M-B E2A-S08KN02-M-B2 NPN E2A-S08KN02-M-C E2A-S08KN02-M-C2 PNP E2A-S08LN02-M-B E2A-S08LN02-M-B2 NPN E2A-S08LN02-M-C E2A-S08LN02-M-C2 PNP E2A-S08KN02-M5-B E2A-S08KN02-M5-B2 NPN E2A-S08KN02-M5-C E2A-S08KN02-M5-C2 PNP E2A-S08LN02-M5-B E2A-S08LN02-M5-B2 NPN E2A-S08LN02-M5-C E2A-S08LN02-M5-C2 ( pin) 27 (9) 9 (6) PNP E2A-S08KN02-M-B E2A-S08KN02-M-B2 NPN E2A-S08KN02-M-C E2A-S08KN02-M-C2 PNP E2A-S08LN02-M-B E2A-S08LN02-M-B2 NPN E2A-S08LN02-M-C E2A-S08LN02-M-C2 *. Cylindrical E2A
M2 M8 Size Output configuration Shielded Nonshielded Shielded Nonshielded 2.0 mm 5.0 mm 5.0 mm.0 mm Connection Body material Thread length (overall length) Pre-wired Brass * (50) M2 Brass * (-pin) (-pin) 56 (72) (8) 56 (70) Brass * (8) 56 (70) Brass * (8) 56 (70) Pre-wired Brass * (50) M2 Brass * (-pin) (-pin) 56 (72) (8) 56 (70) Brass * (8) 56 (70) Brass * (8) 56 (70) Pre-wired Brass * 9 (59) M2 Brass * (-pin) (-pin) 6 (8) 9 (5) 6 (75) Brass * 9 (5) 6 (75) Brass * 9 (5) 6 (75) Pre-wired Brass * 9 (59) M2 Brass * (-pin) (-pin) 6 (8) 9 (5) 6 (75) Brass * 9 (5) 6 (75) Brass * 9 (5) 6 (75) Operation mode NO Operation mode NC Operation mode NO + NC PNP E2A-M2KS02-WP-B 2M E2A-M2KS02-WP-B2 2M E2A-M2KS02-WP-B 2M NPN E2A-M2KS02-WP-C 2M E2A-M2KS02-WP-C2 2M E2A-M2KS02-WP-C 2M PNP E2A-M2LS02-WP-B 2M E2A-M2LS02-WP-B2 2M E2A-M2LS02-WP-B 2M NPN E2A-M2LS02-WP-C 2M E2A-M2LS02-WP-C2 2M E2A-M2LS02-WP-C 2M PNP E2A-M2KS02-M-B E2A-M2KS02-M-B2 E2A-M2KS02-M-B NPN E2A-M2KS02-M-C E2A-M2KS02-M-C2 E2A-M2KS02-M-C PNP E2A-M2LS02-M-B E2A-M2LS02-M-B2 E2A-M2LS02-M-B NPN E2A-M2LS02-M-C E2A-M2LS02-M-C2 E2A-M2LS02-M-C PNP E2A-M2KS02-M5-B E2A-M2KS02-M5-B2 n.a. NPN E2A-M2KS02-M5-C E2A-M2KS02-M5-C2 n.a. PNP E2A-M2LS02-M5-B E2A-M2LS02-M5-B2 n.a. NPN E2A-M2LS02-M5-C E2A-M2LS02-M5-C2 n.a. PNP E2A-M2KS02-M-B E2A-M2KS02-M-B2 n.a. NPN E2A-M2KS02-M-C E2A-M2KS02-M-C2 n.a. PNP E2A-M2LS02-M-B E2A-M2LS02-M-B2 n.a. NPN E2A-M2LS02-M-C E2A-M2LS02-M-C2 n.a. PNP E2A-M2KN05-WP-B 2M E2A-M2KN05-WP-B2 2M E2A-M2KN05-WP-B 2M NPN E2A-M2KN05-WP-C 2M E2A-M2KN05-WP-C2 2M E2A-M2KN05-WP-C 2M PNP E2A-M2LN05-WP-B 2M E2A-M2LN05-WP-B2 2M E2A-M2LN05-WP-B 2M NPN E2A-M2LN05-WP-C 2M E2A-M2LN05-WP-C2 2M E2A-M2LN05-WP-C 2M PNP E2A-M2KN05-M-B E2A-M2KN05-M-B2 E2A-M2KN05-M-B NPN E2A-M2KN05-M-C E2A-M2KN05-M-C2 E2A-M2KS05-M-C PNP E2A-M2LN05-M-B E2A-M2LN05-M-B2 E2A-M2LS05-M-B NPN E2A-M2LN05-M-C E2A-M2LN05-M-C2 E2A-M2LS05-M-C PNP E2A-M2KN05-M5-B E2A-M2KN05-M5-B2 n.a. NPN E2A-M2KN05-M5-C E2A-M2KN05-M5-C2 n.a. PNP E2A-M2LN05-M5-B E2A-M2LN05-M5-B2 n.a. NPN E2A-M2LN05-M5-C E2A-M2LN05-M5-C2 n.a. PNP E2A-M2KN05-M-B E2A-M2KN05-M-B2 n.a. NPN E2A-M2KN05-M-C E2A-M2KN05-M-C2 n.a. PNP E2A-M2LN05-M-B E2A-M2LN05-M-B2 n.a. NPN E2A-M2LN05-M-C E2A-M2LN05-M-C2 n.a. PNP E2A-M8KS05-WP-B 2M E2A-M8KS05-WP-B2 2M E2A-M8KS05-WP-B 2M NPN E2A-M8KS05-WP-C 2M E2A-M8KS05-WP-C2 2M E2A-M8KS05-WP-C 2M PNP E2A-M8LS05-WP-B 2M E2A-M8LS05-WP-B2 2M E2A-M8LS05-WP-B 2M NPN E2A-M8LS05-WP-C 2M E2A-M8LS05-WP-C2 2M E2A-M8LS05-WP-C 2M PNP E2A-M8KS05-M-B E2A-M8KS05-M-B2 E2A-M8KS05-M-B NPN E2A-M8KS05-M-C E2A-M8KS05-M-C2 E2A-M8KS05-M-C PNP E2A-M8LS05-M-B E2A-M8LS05-M-B2 E2A-M8LS05-M-B NPN E2A-M8LS05-M-C E2A-M8LS05-M-C2 E2A-M8LS05-M-C PNP E2A-M8KS05-M5-B E2A-M8KS05-M5-B2 n.a. NPN E2A-M8KS05-M5-C E2A-M8KS05-M5-C2 n.a. PNP E2A-M8LS05-M5-B E2A-M8LS05-M5-B2 n.a. NPN E2A-M8LS05-M5-C E2A-M8LS05-M5-C2 n.a. PNP E2A-M8KS05-M-B E2A-M8KS05-M-B2 n.a. NPN E2A-M8KS05-M-C E2A-M8KS05-M-C2 n.a. PNP E2A-M8LS05-M-B E2A-M8LS05-M-B2 n.a. NPN E2A-M8LS05-M-C E2A-M8LS05-M-C2 n.a. PNP E2A-M8KN-WP-B 2M E2A-M8KN-WP-B2 2M E2A-M8KN-WP-B 2M NPN E2A-M8KN-WP-C 2M E2A-M8KN-WP-C2 2M E2A-M8KN-WP-C 2M PNP E2A-M8LN-WP-B 2M E2A-M8LN-WP-B2 2M E2A-M8LN-WP-B 2M NPN E2A-M8LN-WP-C 2M E2A-M8LN-WP-C2 2M E2A-M8LN-WP-C 2M PNP E2A-M8KN-M-B E2A-M8KN-M-B2 E2A-M8KN-M-B NPN E2A-M8KN-M-C E2A-M8KN-M-C2 E2A-M8KS-M-C PNP E2A-M8LN-M-B E2A-M8LN-M-B2 E2A-M8LS-M-B NPN E2A-M8LN-M-C E2A-M8LN-M-C2 E2A-M8LS-M-C PNP E2A-M8KN-M5-B E2A-M8KN-M5-B2 n.a. NPN E2A-M8KN-M5-C E2A-M8KN-M5-C2 n.a. PNP E2A-M8LN-M5-B E2A-M8LN-M5-B2 n.a. NPN E2A-M8LN-M5-C E2A-M8LN-M5-C2 n.a. PNP E2A-M8KN-M-B E2A-M8KN-M-B2 n.a. NPN E2A-M8KN-M-C E2A-M8KN-M-C2 n.a. PNP E2A-M8LN-M-B E2A-M8LN-M-B2 n.a. NPN E2A-M8LN-M-C E2A-M8LN-M-C2 n.a. 2 Cylindrical E2A
M0 Size.0 mm 8.0 mm Shielded Nonshielded Connection Pre-wired Brass * (6) M2 Brass * (-pin) (-pin) Pre-wired Brass * M2 Brass * (-pin) (-pin) Body material 66 (86) (58) 66 (80) Brass * (58) 66 (80) Brass * (58) Brass * Brass * Thread length (overall length) 66 (80) (6) (See note.) 66 (86) (58) (See note.) 66 (80) (58) (See note.) 66 (80) (58) (See note.) 66 (80) Output configuration Operation mode NO Operation mode NC Operation mode NO + NC PNP E2A-M0KS-WP-B 2M E2A-M0KS-WP-B2 2M E2A-M0KS-WP-B 2M NPN E2A-M0KS-WP-C 2M E2A-M0KS-WP-C2 2M E2A-M0KS-WP-C 2M PNP E2A-M0LS-WP-B 2M E2A-M0LS-WP-B2 2M E2A-M0LS-WP-B 2M NPN E2A-M0LS-WP-C 2M E2A-M0LS-WP-C2 2M E2A-M0LS-WP-C 2M PNP E2A-M0KS-M-B E2A-M0KS-M-B2 E2A-M0KS-M-B NPN E2A-M0KS-M-C E2A-M0KS-M-C2 E2A-M0KS-M-C PNP E2A-M0LS-M-B E2A-M0LS-M-B2 E2A-M0LS-M-B NPN E2A-M0LS-M-C E2A-M0LS-M-C2 E2A-M0LS-M-C PNP E2A-M0KS-M5-B E2A-M0KS-M5-B2 n.a. NPN E2A-M0KS-M5-C E2A-M0KS-M5-C2 n.a. PNP E2A-M0LS-M5-B E2A-M0LS-M5-B2 n.a. NPN E2A-M0LS-M5-C E2A-M0LS-M5-C2 n.a. PNP E2A-M0KS-M-B E2A-M0KS-M-B2 n.a. NPN E2A-M0KS-M-C E2A-M0KS-M-C2 n.a. PNP E2A-M0LS-M-B E2A-M0LS-M-B2 n.a. NPN E2A-M0LS-M-C E2A-M0LS-M-C2 n.a. PNP E2A-M0KN8-WP-B 2M E2A-M0KN8-WP-B2 2M E2A-M0KN8-WP-B 2M NPN E2A-M0KN8-WP-C 2M E2A-M0KN8-WP-C2 2M E2A-M0KN8-WP-C 2M PNP E2A-M0LN8-WP-B 2M E2A-M0LN8-WP-B2 2M E2A-M0LN8-WP-B 2M NPN E2A-M0LN8-WP-C 2M E2A-M0LN8-WP-C2 2M E2A-M0LN8-WP-C 2M PNP E2A-M0KN8-M-B E2A-M0KN8-M-B2 E2A-M0KN8-M-B NPN E2A-M0KN8-M-C E2A-M0KN8-M-C2 E2A-M0KN8-M-C PNP E2A-M0LN8-M-B E2A-M0LN8-M-B2 E2A-M0LN8-M-B NPN E2A-M0LN8-M-C E2A-M0LN8-M-C2 E2A-M0LN8-M-C PNP E2A-M0KN8-M5-B E2A-M0KN8-M5-B2 n.a. NPN E2A-M0KN8-M5-C E2A-M0KN8-M5-C2 n.a. PNP E2A-M0LN8-M5-B E2A-M0LN8-M5-B2 n.a. NPN E2A-M0LN8-M5-C E2A-M0LN8-M5-C2 n.a. PNP E2A-M0KN8-M-B E2A-M0KN8-M-B2 n.a. NPN E2A-M0KN8-M-C E2A-M0KN8-M-C2 n.a. PNP E2A-M0LN8-M-B E2A-M0LN8-M-B2 n.a. NPN E2A-M0LN8-M-C E2A-M0LN8-M-C2 n.a. *. Material specifications for stainless steel housing case:.05 (W.-No.), SUS 0 (AISI), 26 (SS). Please contact your OMR representative for other stainless steel materials. *2. Please contact your OMR representative for DC 2-wire models. *. Stainless steel models are also available. Please contact your OMR representative. Note:M0 non-shielded Models with double sensing and short barrels cannot be mounted due to the necessary separation from the surrounding metal. Standard sensing models are thus available. Connectivity The E2A sensors are available with the following s and cable materials: Pre-wired models Pre-wired models with cable end s Standard cable lengths are 2m and 5m. For other cable lengths please contact your OMR representative. Standard cable material: PVC (dia mm) -WP Other available cable materials and sizes: - PVC (dia 6mm) -WS - PUR/PVC PUR jacket (dia mm) -WA - PUR/PVC PUR jacket (dia 6mm) -WB - PVC robotic cable (dia mm) -WR All pre-wired models can be fitted with cable and s. Standard cable end s: - M2 MJ - ( pin) MJ - ( pin) M5J Other cable end s are available on request. Connector models Standard s: M2, ( or pin) -M, -M, -M5 Cylindrical E2A
Model Number Legend E2A@-@@@@@-@-@@-@@ 2 5 6 7 8 9 2 Example: E2A-M2LS0-M-B Standard, M2, long barrel, shielded, Sn= mm, M2, PNP-NO E2A-S08KN0-WP-B 5M Standard, stainless steel, short barrel, non-shielded, Sn= mm, pre-wired PVC cable, PNP-NO, cable length=5 m. Basic name 8. Kind of connection E2A WP: pre-wired, PVC, dia mm (standard) 2. technology WS: pre-wired, PVC, dia 6mm Blank: Standard double WR: pre-wired, PVC, robotic cable, dia mm. Housing shape and material WA: pre-wired, PUR/PVC (PUR jacket), dia mm M: Cylindrical, metric threaded, brass WB: pre-wired, PUR/PVC (PUR jacket), dia 6mm S: Cylindrical, metric threaded, stainless steel. Housing size M: M2 ( pin) * 08: 8 mm M: ( pin) 2: 2 mm M5: ( pin) 8: 8 mm 0: 0 mm MJ pre-wired with M2 cable end ( pin) 5. Barrel length MJ pre-wired with cable end ( pin) K: Standard length M5J pre-wired with cable end ( pin) L: Long body 9. Power source and output 6. Shield B: DC, -wire, PNP open collector S: Shielded C: DC, -wire, NPN open collector N: Non-shielded D: DC, 2-wire 7. E: DC, -wire, NPN voltage output Numeral: : e.g. 02=2 mm, 6=6 mm F: DC, -wire, PNP voltage output.operation mode : Normally open (NO) 2: Normally closed (NC) : Antivalent (NO+NC).Specials (e.g., cable material, oscillating frequency) 2.Cable length Blank: Connector type Numeral: Cable length Note: *In case of DC 2-wire models the M2 identifier is '-MG' Cylindrical E2A
Specifications DC -wire Models / DC -wire (NO+NC) Item Size M2 Type Shielded Non-shielded Shielded Non-shielded E2A-S08@S0-@@-B E2A-S08@S0-@@-C E2A-S08@N02-@@-B E2A-S08@N02-@@-C E2A-M2@S02-@@-B@ E2A-M2@S02-@@-C@ E2A-S2@S02-@@-B@ E2A-S2@S02-@@-C@ E2A-M2@N05-@@-B@ E2A-M2@N05-@@-C@ E2A-S2@N05-@@-B@ E2A-S2@N05-@@-C@.5 mm ± % 2 mm ± % 2 mm ± % 5 mm ± % Setting 0 to.2 mm 0 to.6 mm 0 to.6 mm 0 to mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target (mild steel ST7) 8 8 mm 8 8 mm 2 2 mm 5 5 mm Response frequency 2,000 Hz,000 Hz,500 Hz 800 Hz Power supply voltage (operating voltage range) Current consumption (DC -wire) Output type Control output Indicator 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) ma max. -B models: PNP open collector -C models: NPN open collector Load current 200 ma max. (2 VDC max.) Residual voltage 2 V max. (under load current of 200 ma with cable length of 2 m) Operation indicator (Yellow LED) Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence -B/-C models: NO -B2/-C2 models: NC -B/ -C models: NO+NC For details, refer to the timing charts. (See note.) Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: -0 C to 70 C, Storage: -0 C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of -25 C to 70 C ±5% max. of sensing at 2 C within temperature range of -0 C to 70 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength,000 VAC at 50/60 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s 2, times each in X, Y and Z directions,000 m/s 2, times each in X, Y and Z directions Standard and listings (See note.) IP67 after IEC 60529 IP69k after DIN 0050 EMC after EN6097-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Connection method Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. Weight (packaged) Material Pre-wired model Approx. 65 g Approx. 85 g Connector model M2 models: Approx. 20 g models: Approx. 5 g Approx. 5 g Case Stainless steel Brass-nickel plated or stainless steel surface PBT Cable Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' Clamping nut Brass-nickel plated Brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between -0 C and -25 C and a power voltage between 0 and 2 VDC, use a load current of 0 ma max.,. For USA and Canada: use class 2 circuit only.. -B/ -C NO+NC models are available in M2, M8 and M0 housings with M2 s, pre-wired and with cable end s. Cylindrical E2A 5
DC -wire Models / DC -wire (NO+NC) Item Size M8 M0 Type Shielded Non-shielded Shielded Non-shielded Non-shielded E2A-M8@S05-@@-B@ E2A-M8@S05-@@-C@ E2A-S8@S05-@@-B@ E2A-S8@S05-@@-C@ E2A-M8@N-@@-B@ E2A-M8@N-@@-C@ E2A-S8@N-@@-B@ E2A-S8@N-@@-C@ E2A-M0@S-@@-B@ E2A-M0@S-@@-C@ E2A-S0@S-@@-B@ E2A-S0@S-@@-C@ E2A-M0KN8-@@-B@ E2A-M0KN8-@@-C@ E2A-S0KN8-@@-B@ E2A-S0KN8-@@-C@ E2A-M0LN8-@@-B@ E2A-M0LN8-@@-C@ E2A-S0LN8-@@-B@ E2A-S0LN8-@@-C@ 5 mm±% mm±% mm±% 8 mm±% 8 mm±% Setting 0 to mm 0 to 8 mm 0 to 8 mm 0 to.5 mm 0 to.5 mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target (mild steel ST7) 8 8 mm 0 0 mm 0 0 mm 5 5 mm 5 5 mm Response frequency 600 Hz 00 Hz 00 Hz 0 Hz 0 Hz Power supply voltage (operating voltage range) Current consumption (DC -wire) Output type Control output Indicator 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) ma max. -B models: PNP open collector -C models: NPN open collector Load current 200 ma max. (2 VDC max.) Residual voltage 2 V max. (under load current of 200 ma with cable length of 2 m) Operation indicator (Yellow LED) Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence -B/-C models: NO -B2/-C2 models: NC -B/ -C models: NO+NC For details, refer to the timing charts. Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: -0 C to 70 C, Storage: -0 C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of -25 C to 70 C ±5% max. of sensing at 2 C within temperature range of -0 C to 70 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength,000 VAC at 50/60 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance,000 m/s 2, times each in X, Y and Z directions Standard and listings (See note.) Connection method Weight (pakkaged) Material IP67 after IEC 60529 IP69k after DIN 0050 EMC after EN6097-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. Pre-wired model Approx. 60 g Approx. 280 g Approx. 280 g Approx. 70 g Connector model Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g Case surface Cable Clamping nut Brass-nickel plated or stainless steel PBT Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between -0 C and -25 C and a power voltage between 0 and 2 VDC, use a load current of 0 ma max.. For USA and Canada: use class 2 circuit only. 6 Cylindrical E2A
DC 2-wire Models Item Size M2 Type Shielded Non-shielded Shielded Non-shielded E2A-S08@S0-D@ E2A-S08@N02-D@ E2A-M2@S02-D@ E2A-S2@S02-D@ E2A-M2@N05-D@ E2A-S2@N05-D@.5 mm ± % 2 mm ± % 2 mm ± % 5 mm ± % Setting 0 to.2 mm 0 to.6 mm 0 to.6 mm 0 to mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target 8 8 mm 8 8 mm 2 2 mm 5 5 mm Response frequency 2,000 Hz,000 Hz,500 Hz 800 Hz Power supply voltage (operating voltage range) Leakage current Output type Control output Indicator (see timing chart) Operation mode Protection circuit Ambient temperature Temperature influence 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) 0.8 ma max. DC 2 wire type Load current to 0 ma Residual voltage V max. (under load current of 0 ma with cable length of 2 m) NO type: Operation indicator (Yellow), Setting indicator (Red) NC type: Operation indicator (Yellow) -D models: NO -D2 models: NC Surget suppressor, Short circuit protection Operating: -0 C to 70 C, Storage: -0 C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of -25 C to 70 C ±5% max. of sensing at 2 C within temperature range of -0 C to 70 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength,000 VAC at 50/60 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s 2, times each in X, Y and Z directions,000 m/s 2, times each in X, Y and Z directions Standard and listings (See note.) IP67 after IEC 60529 IP69k after DIN 0050 EMC after EN6097-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Connection method Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. Weight (packaged) Material Pre-wired model Approx. 65 g Approx. 85 g Connector model M2 models: Approx. 20 g models: Approx. 5 g Approx. 5 g Case Stainless steel Brass-nickel plated or stainless steel surface PBT Cable Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' Clamping nut Brass-nickel plated Brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between -0 C and -25 C and a power voltage between 0 and 2 VDC, use a load current of 50 ma max.. For USA and Canada: use class 2 circuit only. Cylindrical E2A 7
DC 2-wire Models Item Size M8 M0 Type Shielded Non-shielded Shielded Non-shielded E2A-M8@S05-D@ E2A-S8@S05-D@ E2A-M8@N-D@ E2A-S8@N-D@ E2A-M0@S-D@ E2A-S0@S-D@ E2A-M0@N8-D@ E2A-S0@N8-D@ 5 mm ± % mm ± % mm ± % 8 m ± % Setting 0 to mm 0 to 8 mm 0 to 8 mm 0 to.5 mm Differential travel % max. of sensing Target Ferrous metal (The sensing decreases with non-ferrous metal.) Standard target 8x8x mm 0x0x mm 0x0x mm 5x5xmm Response frequency 600 Hz 00 Hz 00 Hz 0 Hz Power supply voltage (operating voltage range) Leakage current Output type Control output Indicator (see timing chart) Operation mode Protection circuit Ambient temperature Temperature influence 2 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) 0.8 ma max. DC 2 wire type Load current to 0 ma Residual voltage V max. (under load current of 0 ma with cable length of 2 m) NO type: Operation indicator (Yellow), Setting indicator (Red) NC type: Operation indicator (Yellow) -D models: NO -D2 models: NC Surget suppressor, Short circuit protection Operating: -0 C to 70 C, Storage: -0 C to 85 C (with no icing or condensation) ±% max. of sensing at 2 C within temperature range of -25 C to 70 C ±5% max. of sensing at 2 C within temperature range of -0 C to 70 C Ambient humidity Operating: 5% to 95%, Storage: 5% to 95% Voltage influence ±% max. of sensing in rated voltage range ±5% Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength,000 VAC at 50/60 Hz for min between current carry parts and case Vibration resistance to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s 2, times each in X, Y and Z directions IP67 after IEC 60529 Standard and listings (See note.) IP69k after DIN 0050 EMC after EN6097-5-2 Pre-wired models (standard is dia mm PVC cable with length = 2m). Connection method Please see chapter 'Connectivity' for details on different cable materials and lenghts and or M2 s. short body: 280 g Pre-wired model Approx. 60 g Approx. 280 g Weight long body: 70 g (packaged) short body: 200 g Connector model Approx. 70 g Approx. 200 g long body: 260 g Case Brass-nickel plated or stainless steel surface PBT Material Cable Standard cable is PVC dia mm. For other cable materials or diameters please refer to chapter 'Connectivity' Clamping nut brass-nickel plated for brass models stainless steel for steel models Note. The response frequency is an average value. Measurement conditions are as follows: standard target, a of twice the standard target between targets, and a setting of half the sensing. 2. When using any model at an ambient temperature between -0 C and -25 C and a power voltage between 0 and 2 VDC, use a load current of 50 ma max.. For USA and Canada: use class 2 circuit only. 8 Cylindrical E2A
Engineering Data Operating Range (Typical) Shielded Models X (mm) 2 8 6 X Y E2A-M0@S E2A-M8@S05 E2A-M2@S02 X (mm) Non-shielded Models 20 5 Y X E2A-M0@N8 E2A-M8@N E2A-M2@N05 2 E2A-S08@S0 5 E2A-S08@N02 0-20 -5 - -5 0 5 5 20 Distance Y (mm) 0-0 -20-0 20 0 Distance Y (mm) Influence of Object Size and Materials Shielded Models E2A-S08@S0 E2A-M2@S02/ E2A-S2@S02 E2A-M8@S05/E2A-S8@S05 X (mm) 2.0.5.0 0.5 @d t = mm X Iron Stainless steel (SUS0) Brass Aluminium Copper X (mm) 2.5 2.0.5.0 0.5 @d t = mm X Iron Stainless steel (SUS0) Brass Aluminium Copper X (mm) 6.0 5.0.0.0 2.0.0 @d t = mm X Iron Stainless steel (SUS0) Brass Aluminium Copper 0 5 5 20 25 Side length of sensing object d (mm) 0 5 5 20 25 Side length of sensing object d (mm) 0 20 0 0 50 Side length of sensing object d (mm) E2A-M0@S/ E2A-S0@S X (mm) 2 @d 8 6 t = mm X Iron Stainless steel (SUS0) Brass Aluminium Copper 2 0 20 0 0 50 60 70 Side length of sensing object d (mm) Cylindrical E2A 9
Non-shielded Models E2A-S08@N02 E2A-M2@N05/E2A-S2@N05 E2A-M8@N/E2A-S8@N X (mm) 2.5 2.0.5.0 0.5 2.5 2 @d @d t=mm t=mm @d X X Iron Iron 2.0 Stainless steel (SUS0) Brass Aluminium Copper X (mm).5.0 Copper 0.5 Stainless steel (SUS0) Brass Aluminium X (mm) 8 6 2 t=mm Iron X Stainless steel (SUS0) Brass Aluminium Copper 0 5 5 20 25 Side length of sensing object d (mm) 0 5 5 20 25 Side length of sensing object d (mm) 0 20 0 0 50 60 Side length of sensing object d (mm) E2A-M0@N8/E2A-S0@N8 X (mm) 20.0 6.0 2.0 8.0.0 @d Iron t=mm X Stainless steel (SUS0) Brass Aluminium Copper 0 20 0 60 80 0 Side length of sensing object d (mm) Cylindrical E2A
Operation DC -wire models PNP Output Operation mode Model Timing chart Output circuit Non-sensing zone object zone Brown +V NO E2A-@-@-B (%) 0 0 Rated sensing Yellow indicator Control output main circuits Black Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) 0 V Connector ( pin) 2 2 Note 2: Terminal 2 of the M2 is not used. NC E2A-@-@-B2 Non-sensing zone object (%) 0 0 Rated sensing zone Yellow indicator Control output main circuits Brown Black ( : ) Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) +V 0 V Connector ( pin) 2 2 Note 2: Terminal of the M2 is not used. Non-sensing zone object (%) 0 0 Rated sensing zone main circuits Brown +V Black NO output Load NO + NC E2A-@-@-B Yellow indicator NO output White 2 NC output NC output Blue Load 0 V M2 Connector 2 Cylindrical E2A
DC -wire models NPN Output Operation mode Model Timing chart Output circuit NO E2A-@-@-C Non-sensing zone object (%) 0 0 Rated sensing zone Yellow indicator Control output main circuits Brown Black Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) +V 0 V Connector ( pin) 2 2 Note 2: Terminal 2 of the M2 is not used. NC E2A-@-@-C2 Non-sensing zone object (%) 0 0 Rated sensing zone Yellow indicator Control output main circuits Brown Black Blue Load Note : With models, there is no output reverse polarity protection diode. M2 Connector ( pin) +V ( : ) 0 V Connector ( pin) 2 2 Note 2: Terminal of the M2 is not used. NO + NC E2A-@-@-C Non-sensing zone object (%) 0 0 Rated sensing zone Yellow indicator NO output main circuits Brown +V Load Black NO output Load White 2 NC output NC output Blue 0 V M2 Connector 2 2 Cylindrical E2A
DC 2-wire models Output Circuit Diagrams (Operation) Operation mode Model Timing chart Output circuit Non-sensing zone object zone Load Brown +V (%) 0 80 0 NO E2A-@-D Rated sensing Yellow indicator Red indicator Control output Load can be connected to +V or 0V side. M2 Connector 2 Blue 0 V Non-sensing zone object zone Load Brown +V (%) 0 0 NC E2A-@-D2 Rated sensing Yellow indicator Control output Load can be connected to +V or 0V side. M2 Connector 2 Blue 0 V Cylindrical E2A
Dimensions Note:All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) Pre-wired Models (Non-shielded) E2A-S08KS0-WP-@@ 0 27 5 E2A-S08KN02-WP-@@ 0 27 6 5 5.8 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M2KS02-WP-@@/E2A-S2KS02-WP-@ 50. 7 7 E2A-M2KN05-WP-@@/E2A-S2KN05-WP-@ 7 7 50. 7 9.2 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m. for NO+NC (-B / -C) models the total length is mm longer E2A-M8KS05-WP@@/E2A-S8KS05-WP-@ Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m. for NO+NC (-B / -C) models the total length is mm longer E2A-M8KN-WP-@@/E2A-S8KN-WP-@ 2 59.5 9 9 2 59.5 M8 E2A-M0KS-WP-@@/E2A-S0KS-WP-@ 6 6.5 5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m 5. dia. M8 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M0KN8-WP-@@/E2A-S0KN8-WP-@ 6.5 6 5 5 M0.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m 26. dia. M0.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m Cylindrical E2A
E2A-S08LS0-WP-@@ 62 9 5 E2A-S08LN02-WP-@@ 6 62 9 5 5.8 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M2LS02-WP-@@/E2A-S2LS02-WP-@ E2A-M2LN05-WP-@@/E2A-S2LN05-WP-@ 72. 72. 7 56 7 7 7 56 7 9.2 dia. Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M8LS05-WP-@@/E2A-S8LS05-WP-@ 2 6 8.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M8LN-WP-@@/E2A-S8LN-WP-@ 2 8.5 6 M8 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M0LS-WP-@@/E2A-S0LS-WP-@ 86.5 66 6 5 5. dia. M8 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m E2A-M0LN8-WP-@@/E2A-S0LN8-WP-@ 86.5 66 6 5 5 26. dia. M0.5 M0.5 Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m Note. -dia. vinyl-insulated round cable with conductors (conductor cross section: 0. mm2; insulator diameter:. mm); standard length: 2 m Mounting Hole Cutout Dimensions F External diameter of Dimension F (mm) 8.5 dia. +0.5 0 M2 M8 M0 2.5 dia. +0.5 0 8.5 dia. +0.5 0 0.5 dia. +0.5 0 Cylindrical E2A 5
M2 Connector Models (Shielded) M2 Connector Models (Non-shielded) E2A-S08KS0-M-@@ E2A-S08KN02-M-@@ 27 5 6 27 5 6 dia. Note: Operation indicator (yellow LED, 90 ) Note: Operation indicator (yellow LED, 90 ) E2A-M2KS02-M-@@/E2A-S2KS02-M-@ E2A-M2KN05-M-@@/E2A-S2KN05-M-@ 8 8 7 7 7 7 7 9. dia. Note : Operation indicator (yellow LED, 90 ) Note 2: for NO+NC (-B / -C) models the total length is mm longer Note : Operation indicator (yellow LED, 90 ) Note 2: for NO+NC (-B / -C) models the total length is mm longer E2A-M8KS05-M-@@/E2A-S8KS05-M-@ E2A-M8KN-M-@@/E2A-S8KN-M-@ 2 9 5 5 9 2 M8 Note: Operation indicator (yellow LED, 90 ) 5. dia. M8 Note: Operation indicator (yellow LED, 90 ) E2A-M0KS-M-@@/E2A-S0KS-M-@ 58 6 5 E2A-M0KN8-M-@@/E2A-S0KN8-M-@ 58 6 5 5 26.6 dia. M0.5 Note: Operation indicator (yellow LED, 90 ) M0.5 Note: Operation indicator (yellow LED, 90 ) 6 Cylindrical E2A
E2A-S08LS0-M-@@ 65 9 5 E2A-S08LN02-M-@@ 6 65 9 5 6 dia. Note: Operation indicator (yellow LED, 90 ) Note: Operation indicator (yellow LED, 90 ) E2A-M2LS02-M-@@ E2A-S2LS02-M-@ 7 56 70 7 E2A-M2LN05-M-@@ E2A-S2LN05-M-@ 7 7 70 56 7 9.2 dia. Note: Operation indicator (yellow LED, 90 ) Note: Operation indicator (yellow LED, 90 ) E2A-M8LS05-M-@@ E2A-S8LS05-M-@ 2 6 75 75 6 2 E2A-M8LN-M-@@ E2A-S8LN-M-@ 5. dia. E2A-M0LS-M-@@ E2A-S0LS-M-@ M8 Note: Operation indicator (yellow LED, 90 ) 80 66 6 5 E2A-M0LN8-M-@@ E2A-S0LN8-M-@ 6 M8 Note: Operation indicator (yellow LED, 90 ) 80 66 5 5 26.6 dia. M0.5 M0.5 Note: Operation indicator (yellow LED, 90 ) Note: Operation indicator (yellow LED, 90 ) Connector Models (Shielded) Connector Models (Non-shielded) E2A-S08KS0-M5-@@/E2A-S08KS0-M-@ 9 27 5 E2A-S08KN02-M5-@@/E2A-S08KN02-M-@ 9 27 6 5 5.8 dia. Note: Operation indicator (yellow LED, 90 ) Note: Operation indicator (yellow LED, 90 ) E2A-S08LS0-M5-@@/E2A-S08LS0-M-@ 6 9 5 E2A-S08LN02-M5-@@/E2A-S08LN02-M-@ 6 9 6 5 5.8 dia. Note: Operation indicator (yellow LED, 90 ) Note: Operation indicator (yellow LED, 90 ) Note: Please contact your OMR sales representative for dimension drawings not listed here. Cylindrical E2A 7
Precautions Safety Precautions Power Supply Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current (0 to 20 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the E2A may be damaged. The E2A s short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Correct Use Designing Power Reset Time The is ready to operate within 0 ms (60ms for NO+NC -B / -C types) after power is supplied. If power supplies are connected to the and load respectively, be sure to supply power to the before supplying power to the load. Effects of Surrounding Metal When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained. l Wiring Be sure to wire the E2A and load correctly, otherwise it may be damaged. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the E2A in operation, otherwise it may damage internal elements. Do not expose the product to flammable or explosive gases. Do not disassemble, repair, or modify the product. Power The may output a pulse signal when it is turned. Therefore, it is recommended that the load be turned before turning the. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more s face-to-face or side-by-side, ensure that the minimum s given in the following table are maintained. (Unit: mm) Type Dimension M2 M8 M0 Shielded m D l 0 0 d dia. 0 (See note.) m.5 8 20 0 d 5 2 8 0 D 0 0 0 0 n 2 8 27 5 l 6 5 22 0 m 8 20 0 70 d 2 0 55 90 D 6 5 22 0 n 2 6 5 90 l n m 0 (See note 2.) (Unit: mm) Type Dimension M2 M8 M0 A 20 0 50 0 Shielded B 5 20 5 70 Nonshielded Nonshielded A 80 20 200 00 B 60 0 200 Note. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of.5 mm. 2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of mm. 8 Cylindrical E2A
Wiring High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the, wire the cable through an independent metal conduit to prevent against damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting The must not be subjected to excessive shock with a hammer when it is installed, otherwise the may be damaged or lose its water-resistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Type Torque Stainless steel type 9 Nm Brass type Nm M2 0 Nm M8 70 Nm M0 80 Nm Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the over a long period of time.. Check for mounting position, dislocation, looseness, or distortion of the and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage.. Check for attachment or accumulation of metal powder or dust.. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the. Environment Water Resistivity The s are tested intensively on water resistance, but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow. Operating Environment Ensure storage and operation of the within the given specifications. Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the, in which case connect the load to the through a relay. <SUITABILITY FOR USE> OMR shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. <CHANGE IN SPECIFICATIS> Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMR representative at any time to confirm actual specifications of purchased product. Cylindrical E2A 9
Cat. No. EE-EN-0A In the interest of product improvement, specifications are subject to change without notice. OMR EUROPE B.V. Wegalaan 67-69, NL-22 JD, Hoofddorf, The Netherlands Phone: + 2 568 00 Fax: + 2 568 88 www.eu.omron.com 20 Cylindrical E2A