Fisher D3 Control Valve



Similar documents
Baumann Little Scotty Bronze Control Valve

Baumann Way Bronze or Stainless Steel Control Valve

Baumann Mikroseal Control Valve

Fisher 657 and 667 Diaphragm Actuators

Fisher 377 Trip Valve

Baumann Flexsleev Sanitary Control Valve

Fisher CV500 Rotary Globe Control Valve

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Fisher 8580 Rotary Valve

Fisher GX Control Valves

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Fisher 2625, 2625SST, and 2625NS Volume Boosters

167D Series Switching Valves

Type 119 Control Valve

Fisher FIELDVUE DVC2000 Digital Valve

Fisher V500 Rotary Globe Control Valve

1805 Series Relief Valves

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Baumann 24000SB Barstock Control Valve

289 Series Spring-Loaded Relief Valves

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 846 Electro-Pneumatic Transducer

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Fisher A11 High-Performance Butterfly Valve

Fisher 646 Electro Pneumatic Transducer

ENVIRO-SEAL. Valve Packing Systems Extending service life. Meeting environmental requirements.

Types 66R and 66RR Low-Pressure Relief Valves

Micro Motion 3098 Gas Specific Gravity Meter

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Fisher GX 3-Way Control Valve and Actuator System

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Fisher 4320 Wireless Position Monitor, with On/Off Control Option

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

3DLevelScanner II TECHNICAL DATA SHEET

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter

Fisher 377 Trip Valve

1301 Series High-Pressure Regulators

4310/4320 Wireless Position Monitor

Fisher Vee-Ball V150, V200, and V300 Rotary Control Valves

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

4 Posiflow Proportional Solenoid Valves

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Type 92S Pilot-Operated Steam Regulator

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

Rosemount 752 FOUNDATION fieldbus Remote Indicator

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

CCI 100 DPC DRAG Wellhead Production Choke Valve

Fisher GX Control Valve and Actuator System

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Fisher EDR and ETR easy-e Valves

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Fisher HP Series Control Valves

Technical Data Sheet. 3DLevelScanner

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Block and Bleed Gauge Valves M25 and M251

STRATO LED Drivers 70W, Single output

Microcor Wireless Transmitter (MWT)

Rosemount 751 Field Signal Indicator

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Type 99 Pressure Reducing Regulator

GS-General Service Control Valves

Fisher C1 Pneumatic Controllers and Transmitters

1756 ControlLogix Chassis Specifications

Fisher ES and EAS Sliding-Stem Control Valves

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Rosemount 333 HART Tri-Loop

Micro Motion Model D and DL Coriolis Flow and Density Meters

Kämmer Series Laboratory Valves

V47 Series Temperature Actuated Modulating Water Valves

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Foxboro Evo Process Automation System

Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Rosemount 333 HART Tri-Loop

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

Rack mounted telephone- and leased line modem for industrial applications

Analog signal converters CC-E I/I Current / current isolators

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

NELES SOFT SEATED BUTTERFLY VALVE SERIES MAPAG BA FOR PSA PLANT ON/OFF AND CONTROL SERVICE

Typical Aluminum GFM Mass Flow Meter

Compact pressure switch Flameproof enclosure Ex d Model PCA

Fisher 249 Caged Displacer Sensors

Fisher FIELDVUE DVC6200 Digital Valve

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Type EZR Relief Valve or Backpressure Regulator

Centro-Matic Automatic Lubrication Systems System Controls

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Fisherr 8510 and 8510B Eccentric Disc Control Valves (EMA)

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Transcription:

D3 Valve Product Bulletin Fisher D3 Control Valve The Fisher D3 control valve is a compact, rugged valve designed for on/off or throttling control, and utilizes FloPro technology, using either pneumatic or electric control. This valve is ideal for use as a dump valve on gas separators and scrubbers. It is also well suited for other high pressure applications in natural gas production, compression, and processing. NPS 1 and 2 D3 control valves are available with CL900 NPT end connections and CL600 raised face flanged end connections. The D3 offers easy maintenance. The trim and packing can be maintained by removing the deep bore hammer nut and lifting the actuator/bonnet assembly off the valve without disassembling the actuator. Features W9797 FISHER D3 CONTROL VALVE WITH Gen 2 easy-drive ELECTRIC ACTUATOR (NPS 2 NPT END CONNECTION) Electric and Pneumatic Safer Bonnet / Valve Body Connection-- The unique design provides additional protection if disassembly of bonnet/valve body connection is inadvertently started while there is still pressure in the valve body. Pins mounted in the valve bonnet help ensure the bonnet disengages from the valve body as the hammer nut is loosened, while the threads are still engaged. This allows internal pressure to be vented, while keeping the actuator retained to the valve body. Field Selectable Flow Rates--The FloPro feature allows adjustment of the flow capacity without changing the trim. In this way, a single trim set can be used for more than one flow requirement, reducing inventory and maintenance costs. See figure 1. W9249 FISHER D3 CONTROL VALVE (NPS 2 RF FLANGED END CONNECTION) Two End Connection Styles-- The D3 control valve is available in both CL900 screwed end and CL600 RF flanged construction. www.fisher.com

Product Bulletin D3 Valve Features (continued) Electric and Pneumatic Two Modes of Actuation-- Pneumatic or electric actuation is available. Quad-O compliant Packing System --Features Fisher ENVIRO-SEAL packing technology to provide reduced packing maintenance and meet Low E fugitive emission requirements for Leak Detection and Repair (LDAR) programs in compliance with the Code of Federal Regulations (CFR) 40, Part 60, Subpart OOOO. Rugged Trim Design--The pinned and guided plug/stem assembly is field proven and easy to maintain. Severe Service Capability with Tungsten Carbide Trim--D3 valves are available with tungsten carbide trim for erosive service. Fisher tungsten carbide trim is designed specifically for severe service applications in the oil and gas industry. Durable tungsten carbide trim may benefit your application by wearing better and lasting longer. Easy Maintenance--The hammer nut bonnet/body joint allows repair or maintenance with a minimum of tools, without removing the valve body from the piping system. The seat ring can be removed with a standard hex socket. Electric Low Power Consumption-- The Fisher easy-drive electric actuator operates from 9 to 30VDC and less than 0.1 watt hours per operation, using Modbus, 4-20 ma, or dry contact control signals. Low Temperature-- The easy-drive electric actuator design allow use in ambient temperatures as low as -20 C (-4 F) without use of a heater. Easy Installation--The compact design allows installation where space is a premium. Fisher easy-drive calibrates by simply opening and closing the valve. Remote Monitoring and Configuration-- Loss of signal position is programmable over Modbus. Pneumatic Low Temperature Materials--Valve construction materials allow use in applications as low as -34 C (-30 F) for the pneumatic actuator. Field Reversible Actuator--The D3 pneumatic actuator can be field converted from spring to close to spring to open action. Integral Bonnet Flange-- The bonnet has an integral flange, retained by a hammer nut, making the bonnet to body connection. This eliminates use of snap rings, which can be subject to possible failure in sour service or in atmospheric corrosion. Application Flexibility--A selection of end connections, trim materials, and flow capacities allows the D3 to be used in a broad range of applications, including sour service. NACE MR0175/ISO 15156 Service Ready--The standard D3 FloPro trim, valve body, and bonnet meet the metallurgical requirements of NACE MR0175/ISO 15156. 2

D3 Valve Product Bulletin Valve Specifications Valve Body Sizes, End Connection Styles, and Port Diameters (1) VALVE SIZE, NPS PORT DIAMETER, (INCHES) THREADED RAISED FACE (RF) FLANGED CL600 CL900 1 0.375, 0.75, 1 X X 2 0.375, 0.75, 1 X X X = Available construction. Maximum Inlet Pressures and Temperatures (1) VALVE BODY SIZE NPS 1 and NPS 2 NPT CL900 NPS 1 and NPS 2 RF CL600 MAXIMUM INLET PRESSURE TEMPERATURE RANGE bar (psig) C ( F) 155 (2250) -46 to 93 (-50 to 200) 150 (2185) 93 to 149 (200 to 300) 103 (1500) -46 to 93 (-50 to 200) 100 (1455) 93 to 149 (200 to 300) Maximum Shutoff Pressure Drops (1) See table 3 Shutoff Classification per ANSI/FCI 70 2 and IEC 60534 4 Class IV Flow Characteristic/Valve Plug Style Equal percentage/micro Form Valve Plug Flow Coefficients See Fisher Catalog 12 Maximum Travel 15 mm (0.6 inch) Material Temperature Capabilities (1) Valve Body Assembly: Standard Bonnet O-Ring: -40 to 135 C (-40 to 275 F) Construction Materials See table 1 Flow Direction Flow Up or Flow Down 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. Table 1. Fisher D3 Materials of Construction Part D3 Material with Pneumatic Actuator D3 Material with easy-drive Electric Actuator Actuator Casing Painted Steel Painted Aluminum Actuator Diaphragm CR (chloroprene/polyester) NA Actuator Springs Painted Steel NA Stem Bushing PPS (polyphenylene sulfide) Bronze - Oil Impregnated Valve Body and Bonnet ASME SA 352 LCC Valve Plug and Seat Standard/Sour: S17400 (NACE MR0175/ISO 15156) Severe Service: Tungsten Carbide/S17400 (NACE MR0175/ISO 15156) Pin S17400 Valve Stem S20910 O rings HNBR (Hydrogenated Nitrile) Packing PTFE/Carbon PTFE Packing Springs N07718 Packing Retainer S17400 3

Product Bulletin D3 Valve Actuator Specifications ELECTRIC ACTUATOR Material Temperature Capabilities (1) Electric Actuator Assembly: -20 to 70 C (-4 to 158 F) ambient Available Electric Actuator Configurations Gen 2 easy-drive Electric On/Off (snap acting) Gen 2 easy-drive Electric Positioning (flow or pressure control) Power Requirements 9 to 30VDC, minimum 4 amp power supply required (fuse to 5 amps), less than 5% ripple, 15 ma quiescent at 24VDC, 25 ma quiescent at 12VDC (40 ma quiescent for Gen 1) Maximum Current Draw 4 amps Nominal Stroke Speed (2) 3.9 mms (0.15 inch/s) at 24VDC 2.2 mm/s (0.09 inch/s) at 12VDC Control Signals On/Off: Dry contact, Modbus RTU Positioning: 4-20 ma, 4-20 ma level, Modbus RTU Auxillary Digital Input (Gen 2 only): Dry contact Auxillary Digital Output (Gen 2 only): 10VDC, 25 ma maximum Hazardous Area Approvals CSA (C/US): Explosion Proof Class I, Division 1, Groups C and D, T6, Ex d IIA T6, Class I, Zone 1, AEx d IIA T6 ATEX Flameproof - Gas: II 2 G, Ex db IIA T6 IECEx Flameproof - Gas: Ex db IIA T6 Enclosure Rating Type 4X and IP66 Electromagnetic Compatibility Meets EN 61326-1 (2013) Immunity: Industrial locations per table 2 of EN 61326-1 Standard. Performance is shown in table 2 Emmissions: Class A ISM Equipment Rating: Group 1, Class A Conduit Connections Two 3/4 NPT connections PNEUMATIC ACTUATOR Material Temperature Capabilities (1) Pneumatic Actuator Assembly: -34 to 82 C (-30 to 180 F) ambient Available Pneumatic Actuator Configurations Spring to Open Spring to Close Maximum Actuator Casing Pressure (1) 3.4 bar (50 psig) Actuator Diaphragm Effective Area 329 cm 2 (51 square inches) Actuator Pressure Connections 1/4 NPT internal 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 2. 10% variation can be expected, based on temperature and pressure of application. 4

D3 Valve Product Bulletin Table 2. EMC Summary Results - Immunity PORT PHENOMENON BASIC STANDARD TEST LEVEL PERFORMANCE CRITERIA (1) Electrostatic discharge (ESD) IEC 61000-4-2 4kV Contact 8kV Air A Enclosure Radiated EM field IEC 61000-4-3 80 to 1000 MHz @ 10V/m 1kHz AM at 80% 1400 to 2000 MHz @ 3V/m 1kHz AM at 80% A 2000 to 2700 MHz @ 1V/m 1kHz AM at 80% Rated power frequency magnetic field IEC 61000-4-8 30 A/m @ 50 and 60 Hz A Burst IEC 61000-4-4 1kV B I/O signal/ control Surge IEC 61000-4-5 1kV cable shield, and line to ground B Conducted RF IEC 61000-4-6 3V 150 khz to 80 MHz at 3 Vrms A Performance criteria is +/- 5% stem position 1. A= No degradation during testing. B = Temporary degradation during testing, but is self recovering. Table 3. Fisher D3 Maximum Shutoff Pressure Drops (Pneumatic) ACTUATOR DESIGN Pneumatic FLOW DIRECTION Up Down ACTUATOR ACTION Spring to Close Spring to Open Spring to Close Spring to Open INPUT SIGNAL NUMBER OF MAXIMUM P (PSI) PER PORT SIZE (INCH) psi SPRINGS 0.375 0.75 1.00 0 20 3 2250 544 341 0 35 6 2250 1504 999 0 20 2 2250 935 608 0 35 2 2250 2250 2094 0 20 2 1558 1800 950 0 35 3 2250 2250 2250 0 20 2 2250 1700 939 0 35 3 2250 2250 1575 Table 4. Fisher D3 easy-drive Maximum Shutoff Pressure Drops (Electric) MAXIMUM P (PSI) PER PORT SIZE (INCH) ACTUATOR DESIGN FLOW DIRECTION 0.375 0.75 1.00 Electric Up 2250 1714 1114 Down 2250 2250 1948 Figure 1. FloPro Adjusts to Vary Flow Capacity (Shown with Valve Plug in Seated Position) 100% 50% CLOSED STEM CONNECTOR INDICATES TRAVEL 100% 50% CLOSED STEM CONNECTOR INDICATES TRAVEL FULL CAPACITY SETTING (FACTORY SET) 15 mm (0.6 INCH) TRAVEL Note: Use the widely-spaced travel indicators, as shown on the left portion of this view. REDUCED CAPACITY SETTING 10 mm (0.4 INCH) TRAVEL Note: Use the closely-spaced travel indicators, as shown on the right portion of this view. Note: See Fisher Catalog 12 for flow coefficients. Full capacity coefficients are shown as 100 percent valve opening. Reduced capacity coefficients are shown as 60 percent valve opening. 5

Product Bulletin D3 Valve Table 5. Fisher D3 Control Valve with easy-drive Electric Actuator Dimensions (also see figure 2) DIMENSION VALVE SIZE A B C D WEIGHT mm Inch mm Inch mm Inch mm Inch kg lb NPS 1 NPT CL900 159 6.25 51 2.00 352 13.86 275 10.83 14 31 NPS 2 NPT CL900 191 7.50 46 1.80 363 14.29 275 10.83 15 34 NPS 1 CL600 RF 210 8.25 56 1.42 364 14.33 275 10.83 18 39 NPS 2 CL600 RF 286 11.25 44 1.74 363 14.29 275 10.83 24 53 Figure 2. Fisher D3 Control Valve with easy-drive Electric Actuator (also see table 5) D C B A/2 A 6

D3 Valve Product Bulletin Table 6. Fisher D3 Control Valve with Pneumatic Actuator Dimensions (1) (also see figure 3) VALVE SIZE DIMENSION A B C D E AR (2) Spring to Close AR (2) Spring to Open WEIGHT mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch kg lb NPS 1 NPT CL900 159 6.25 51 2.00 148 5.83 289 11.38 127 5.00 57 2.25 76 3.00 16 35 NPS 2 NPT CL900 191 7.50 46 1.80 159 6.28 289 11.38 127 5.00 57 2.25 76 3.00 17 38 NPS 1 CL600 RF 210 8.25 36 1.42 160 6.32 289 11.38 127 5.00 57 2.25 76 3.00 19 42 NPS 2 CL600 RF 286 11.25 44 1.74 159 6.28 289 11.38 127 5.00 57 2.25 76 3.00 25 56 1. All dimensions except AR are identical for both spring to close and spring to open. 2. Actuator removal clearance. Figure 3. Fisher D3 Control Valve with Pneumatic Actuator Dimensions (also see table 6) D AR E C B A/2 GE21316 A 7

Product Bulletin D3 Valve Figure 4. Fisher D3 Control Valve with Size 30 Actuator and NPS 2 Flanged Valve Body (Spring to Open Configuration) GE21342 Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher, easy-drive, and ENVIRO-SEAL are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay, 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 8 2006, 2016 Fisher Controls International LLC. All rights reserved.