LAWAREC. Laser Warning Receiver



Similar documents
USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

DRONE DETECTION RADAR

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

SDI TO HD-SDI HDTV UP-CONVERTER BC-D2300U. 1080i/720p HDTV Up-Converter with built-in Audio/Video processor

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Hygro-Thermometer + InfraRed Thermometer Model RH101

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Analogue addressable devices

Mini InfraRed Thermometer with Laser Pointer

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

GSM Alarm System User Manual

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

e I N S T RUC TION M ANU A L

DIVERSITRONICS, INC. TM

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Ultrasonic Distance Meter. Operation Manual

MANUAL FOR RX700 LR and NR

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

GSM HOME SECURITY SYSTEM

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Photo Modules for PCM Remote Control Systems

EMR-300 Broadband RF Survey Meter

Dual Laser InfraRed (IR) Thermometer with Color Alert

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

TMS TANK MANAGEMENT SYSTEM

Experiment 5. Lasers and laser mode structure

Original instructions Tina 3A/Aps Adaptor unit

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

VS-0202 VS User Manual

Fire suppression system for engine compartments USER MANUAL

USER GUIDE. LED Light Meter. Model LT45

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Sea Eagle FCCT. Naval Electro-Optical Fire Control System

Field Service Application

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

Distributed Temperature Sensing - DTS

StructureScan HD Module. Installation Guide ENGLISH

WD-AMX Water Detection Controllers

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

DIGITAL SATELLITE FINDER USER S MANUAL

12 Volt 30 Amp Digital Solar Charge Controller

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;

Smoke exhaust systems

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Module 13 : Measurements on Fiber Optic Systems

STERILIZERS, LABORATORY DRYING OVENS

Sensor Integration in the Security Domain

Technical Data FLIR E40bx (incl. Wi-Fi)

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

ASP-DTH. DVI & Audio to HDMI Converter. User Manual. Manual Number:

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

New Inspection Systems Based on the Registration of the Backscattered X-rays

Terma SKWS Decoy Launching System. the weapon of least regret

Flarm LED indicator. Version 1.1

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

N4385A / N4386A Distributed Temperature System (DTS)

PRODUCT SHEET OUT1 SPECIFICATIONS

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

LASER-PROTECTION INFORMATION

LASER SAFETY MANUAL UNIVERSITY OF KENTUCKY POLICIES AND PROCEDURES FOR LASER USERS REVISED EDITION 2012 ISSUED BY

XIA-USB INSTALLATION INSTRUCTIONS

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

Product Information Sheet UH28CS-12kV Hi Pot Tester

8 by 8 dot matrix LED displays with Cascadable Serial driver B32CDM8 B48CDM8 B64CDM8 General Description

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

1 de 13. Kit de 37 sensores compatibles con Arduino

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Fire detection equipment

User Manual 使 用 者 指 南. Aputure Manufacturing Authority

CX Zoner Installation & User Guide

The World Smallest Automatic Satellite Antenna

GST301. (Single Protection Zone) Operation Manual

M-D,T,Q-series BroadLighter. Benchtop Broadband Light Source with Extended Bandwidth. Technical Product Specification

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Solution 1: Algorithm Positioning

RPLIDAR. Low Cost 360 degree 2D Laser Scanner (LIDAR) System Development Kit User Manual Rev.1

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Frequency Converter Fv

CopyBox SD/USB Duplicator

Dual Laser InfraRed (IR) Thermometer

DMX2PWM 9 Channel Dimmer Setup Manual

igadgitz Bluetooth Audio Transmitter & Receiver (BTT009 / U3442) User Guide

Transcription:

METRODAT, s.r.o. Beblavého 8 SK-811 01 Bratislava Slovak Republic tel.: fax: e-mail: web: +421 905 70 70 71 +421 2 544 11 448 metrodat@netax.sk www.metrodat.eu LAWAREC The LAWAREC (LAser WArning RECeiver) is a system used for detecting laser and radar irradiation aimed at protected military vehicles and other objects. Laser Technology - Defence and Security Applications

USE AND DESCRIPTION: The detection system of laser and radar exposure is primarily aimed at the protection of objects against warfare devices that use laser beams for aiming, designation or recognition or radar scanning.. The construction of the detector head enables it to be installed on all kinds of combat and transport vehicles and also on civilian or military stationary objects (for example communication and combat centers, gasoline pumps, bridges, etc.) while the distance between the detection head and the control unit can be from zero to 200 meters. If needed, it can be extended several times. Detection head is installed on convenient locations on the exterior of the object so that it does not interfere with other functional systems (observation systems, weapon systems etc.). There are three types of detection heads - detection heads containing either only laser sections with 8 or 12 spatially oriented IR receivers, or a combination of radar sections with 4 radar detection modules and 8 or 12 spatially oriented IR receivers. The central unit located inside the object processes incoming information from the detection head, evaluates them, and then offers the operator a summary about the laser and radar activities of the enemy. Simultaneously it suggests a solution to the actual situation (firing smoke grenades) which in semi-automatic mode waits for the operator's confirmation and in automatic mode directly executes the countermeasures to defeat enemy activities. The central unit indicates the actual state in real time, and sends this information through the serial link to the superior system; it also sends an audio signal indicating a threat to the intercom. Simultaneously, it saves all incidents on the internal memory for later review. Smoke grenade launchers are connected to the central unit (max. two sets, 8 smoke grenades each) to make a smoke screen between the protected object and the source of irradiation. The central unit also contains security circuits (interlock) as protection against unwanted firing of smoke grenades in the case of an open vehicle hatchway, avoiding injury to the persons on the object. This protection can be in case of the necessity manually blocked for the purpose of manual grenades firing. In automatic mode (in the combat situation), the protection is blocked permanently. To switch the automatic mode on, it is necessary to keep the algorithm of switching in order to avoid accidental unwanted switching to this mode by reason of the operators' safety against unwanted grenade firing. Additionally, the central unit allows manual firing of selected smoke grenades in case of the complete failure of internal electronics. This mode with the indication of the grenade launcher's status is fully autonomous and independent of the electronic circuits of the unit. That means that for the operation in manual mode, only board 24 V is needed.

TECHNICAL DATA: LW5-8D LW5-12D LW5-8D-4R Detection head LW5-8D LW5-12D LW5-8D-4R Number of IR detection modules 8 12+1 8 Number of radar detection modules - - 4 Spectral range of IR detection 750-1750 nm (2200 nm) Threshold intensity of IR detection 2 less or equal 10 W/m Pulse width: 10 500 ns Sensitivity of radar detection modules - - -51 dbm Field of vision of modules in azimuth 45 30 45 Field of vision of modules in elevation -20 +60-20 +60-20 +60 Total field of vision of the detector in azimuth 360 360 360 Total field of vision of the detector in elevation 80 80 80 Weight: 2,5 kg 2,5 kg 3,1 kg Operating temperature: -20 50 C -20 50 C -20 50 C Control unit Number of IR distinguished sectors in azimuth 16 24 16 Number of radar distinguished sectors in azimuth - - 4 Number of distinguished sectors in elevation 1 2 1 Angle of IR resolution in azimuth 22,5 15 22,5 Angle of radar resolution in azimuth - - 90 Length of IR acoustic warning can be set 210 s Radar acoustic warning according to real radar scanning Length of visual warning can be set 2-10 s Time delay of the reaction (in autonomous mode) can be set 0,5-8 s Power input 24 V (15-30V=) Power consumption 12 W Dimensions 100 x 160 x 50 mm Frequency of false detections less or equal to 1/24h

CONTROL PANEL: ESC Indicating elements: Operating elements: Inputs/Outputs: Round display, 16 green light arrows - indication of laser irradiation direction, 4 red light signs - indication of radar irradioation direction LCD display 2 x 20 - irradiation parameters, records 8 x tricolor LED - launcher state Two-color LED - interlock state Flashing LED - automatic operating mode Mode switch: - off - manual mode - semiautomatic (confirmation is needed) - automatic mode Manual launcher selection Interlock unblocking Manual shooting / confirmation Display control: - line up - line down - selection confimation - back 6 pin Cannon female - detection heads chain connection 6 pin Cannon male - superior system interface 12 pin Cannon female - grenade launcher connection 12 pin Cannon male - power supply, interlock, intercom

BASIC DIMENSIONS 110 66 D 124 D 124 LW5-8D, LW5-12D LW5-8D-4R EXAMPLE OF LAWAREC INSTALLATION

METRODAT s.r.o. is a development, production and distribution company established in 1990, focused on the development of military applications of laser technologies and the developement of technical means for the fight against terrorism. PRODUCTS: LAWAREC LW5-8D LAWAREC LW5-12D LAWAREC LW5-8D-4R Laser/Radar Warning Receiver LAWAREC BRICK Laser/Radar Warning Receiver LAWAREC BUTTON GARVAN GV04 Laser Rangefinder ML-780B-R Ruggedized Thermal Imaging Module MS-780C Thermal Imaging Weapon Scope METRODAT, s.r.o. Beblavého 8 SK-811 01 Bratislava Slovak Republic Laser Technology - Defence and Security Applications tel.: fax: e-mail: web: +421 905 70 70 71 +421 2 544 11 448 metrodat@netax.sk www.metrodat.eu