INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812



Similar documents
Jay R. Smith Mfg. Co.

MIFAB INTERCEPTOR SELECTION GUIDE

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

ROOF DRAINS TABLE OF CONTENTS

Guidelines for Precast Concrete Grease Interceptors

SAN JACINTO RIVER AUTHORITY GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS, INTERCEPTORS AND SEPERATORS

Grease Trap Maintenance, Procedures and Cleaning Logs

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

National Precast Concrete Association

Basic Principles for Sizing Grease Interceptors

FLOOR AND AREA DRAINS

GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS

Oil Interceptors. The Most Effective Way to Remove Oil and Grease From Water

PLUMBING ROUGH IN INSPECTION

Jay R. Smith Mfg. Co.

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

Manual contents includes:

CHAPTER 11 STORM DRAINAGE

2006 Codes. Please verify the following before calling for inspection

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Editorial Note: bold and underline denotes added text, strikethrough denotes deleted text

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Food Service Facilities

Fats, Oil, and Grease (FOG) Best Management Practices (BMP) For Food Service Facilities. Guidance Manual

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

Top 10+ Mistakes of DWV plumbing design

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

CHAPTER 11 STORM DRAINAGE

To many people, a home s plumbing system is perceived as being extremely

Septic System Owner s Manual

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Best Management Practices Fats, Oils, & Grease

Fats, Oil and Grease Program Kit

Hydro Mechanical v. Gravity Grease Interceptors TS Saturday 9:00am 12:00pm Rand Ackroyd

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

WHY A FATS, OILS AND GREASE PROGRAM. Employee Food Service Establishment Information Sheet INTRODUCTION

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

FOOD SERVICE FACILITIES Best Management Practices Stormwater Management Program City of Bluff City P.O. Box 70, Bluff City, TN

SECTION SOIL AND WASTE SYSTEMS

How do I clean my grease trap? Refer to Grease Trap and Interceptor Maintenance.

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

PURE. Table of Contents. Performance. I. About Rockford Separators 3. II. Grease Separators/ Interceptors 7. III. Automatic Grease Recovery Unit 8

Prevent Blockages in the Sanitary Sewer System

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS

Fats, Oils, and Grease Best Management Practices Manual

Homeowner s Guide to Maintaining a Sewage Treatment System

How To Install An Overhead Sewer

foundation designed to keep water out of the basement.

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY. a guide to PREVENTING SEWER BACKUPS AND FLOODING

How to Protect Your Property Against Plumbing Disasters

Grease Traps and Interceptors

1.2 How Does FOG Affect You? The City of Huntington Beach FOG Control Program.. 2

Amendments to the 2012 International Plumbing Code

Best Management Practices and Grease Control Device Maintenance for Food Service Establishment Employees

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

SECTION FACILITY STORM DRAINAGE PIPING

NPCA WHITE PAPER DESIGN CONSIDERATIONS AND DISCUSSION OF PRECAST CONCRETE GRAVITY GREASE INTERCEPTORS

Element D Services Plumbing

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Residential Plumbing BCN 1058

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Best Management Practices

Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal

Septic System Design Manual

CHAPTER 10 TRAPS AND INTERCEPTORS

CODE GUIDE 302 and Glossary of Industry Terms

The Town of Lakeshore Basement Flooding Information to Residents

Downspout to storm sewer. Leaky laterals

Flygt Ball Check Valves

Septic System. Responsibility! Is Your. You should know that:

FOG PRETREATMENT INFORMATION. New London Public Utilities F.O.G. Program 120 Broad Street New London, CT 06320

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

Specifications for Residential Property Owners Connection to New Public Sewer

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Fabricated Drainage Products

What to Expect From the Examination. How to Study the Plumbing Codes

Outdoor Liquid Container Storage

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

SEWER BACK UP PREVENTION PILOT PROGRAM

October 5, 2015 Dear Client,

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Welcome: What is U Drain? Drain Materials. Flow

On-site Sewage Disposal Systems A HOMEOWNER S GUIDE

Grease 101. Why is Grease a Problem?

COMBINED SEWER OVERFLOW OPERATIONAL AND MAINTENANCE PLAN SUMMARY

How To Keep Grease Out Of The Sewer

First in Service First in Safety

good to know... SEWER BACKUP A guide to protecting your home

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Plugging Home Drains to Prevent Sewage Backup

Transcription:

TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment Interceptors Typical Installations S-WD-INTER-1 0812

PICTORIAL INDEX WD SERIES PDI Certified Grease Interceptor WD-LA SERIES Semi-Automatic Low Rough-In Grease Interceptor SI-742 Sediment Interceptor SI-762 Bottom Access Hair, Plaster & Sediment Interceptor WD-L SERIES PDI Certified Low Rough-In Grease Interceptor GI-K SERIES Large Capacity Grease Interceptor SI-740-L Large capacity Sediment Interceptor LI SERIES Lint Interceptor Photo not available at this time WD-A SERIES Semi-Automatic Grease Interceptor OI SERIES Oil Interceptor SI-750 Hair Interceptor SA Sediment Interceptor WD-AH SERIES Semi-Automatic Grease Interceptor w/housing OI-K SERIES Large Capacity Oil Interceptor SI-750-TO Chrome Plated Top Outlet Hair Interceptor S-WD-INTER-2 0812

Application PRODUCT RECOMMENDATIONS Product Art Rooms, Dental Labs, Metal Recovery... SI-742, SI-742-L, SI-762 Commercial Laundry, Washing Machines... LI-800 Cooking, Prep Sinks, Dishwasher... WD Series, GI-K Series Elevator Pits & Oil Spill Areas... OI Series, OI-K Series Hair Wash Sinks... SI-750, SI-750-TO Pot, Pan, Scullery Sinks... WD Series, GI-K Series Sand & Sediment... SA Series, See Also FD-410 Catch Basin Vehicle & Maintenance Areas... OI Series, OI-K Series GREASE INTERCEPTORS Watts Grease Interceptors are designed to remove grease and similar substances from waste water. Interceptors prevent greasy substances from entering plumbing systems, septic fields, and waste water treatment facilities, where they are difficult to process, and can create environmental problems. Commonly specified in restaurant kitchens and food handling or processing areas, properly specified and maintained interceptors keep drainage systems free of problematic grease accumulations. Grease interceptors will separate all lighter-than-water substances, collecting them inside the interceptor, above the static water line. Design criteria is determined by plumbing code, typically following guidelines set forth by The Plumbing & Drainage Institute (PDI), which tests and rates interceptors. The accepted industry and PDI Standard (PDI-G101) is for interceptors to maintain 90% separation efficiency, up to the rated grease retention capacity (in lbs.). The interception process is accomplished using the principle of attraction of like substances. A flow restrictor on the inlet side slows incoming effluent, re-directing it through baffling inside the interceptor. Slowing and baffling processes allow lighter-than-water substances (grease) to accumulate above the static water line. The remaining water, free of grease, is forced through the trap leg on the outlet side of the interceptor, and into the waste water drainage system. Epoxy Coated Steel - Interceptor body standard 11 ga. CR steel, with oven cured, acid resistant baked gray epoxy coating, inside and out. Lid is epoxy coated 1/4" skid-proof checker plate steel, gasketted, and secured with Allen head center bolt(s). All stainless steel construction may be specified for high sanitary applications. Flow Restrictor - WD Series Interceptors are supplied with an external cast iron flow restrictor. All other interceptor models are designed with a built-in stainless steel flow restrictor plate, located just inside the inlet. S-WD-INTER-3 0812

GREASE INTERCEPTORS Grease interceptors are sized according to the rate of incoming flow, in gallons per minute (GPM). Associated with the incoming flow rate is an interceptor's capacity. The rated capacity, in lbs., is listed at twice the flow rate, in GPM. For example, a 10 GPM interceptor has a rated capacity of 20 lbs. Typical Configurations SINK VENTED VENTED WASTE WASTE SINK VENTED WASTE VENTED WASTE SINK VENTED WASTED FLOW FLOW CONTROLLER TEE FLOW CONTROLLER TEE TEE FLOW FLOW CONTROLLER TEE S-WD-INTER-4 0812 ON FLOOR RECESSED RECESSED WITH EXTENSION

GREASE INTERCEPTORS No Hub (Standard) - Butt connection using no hub or neoprene coupling, suitable for cast iron, plastic, and most other piping applications. Threaded (T) - Female IPS threaded connections. Commonly Specified Options Sediment Bucket (-B) - Epoxy coated steel, located inside interceptor on inlet side. Collects large food or other particles. To the extent possible, sediment should be strained or collected at the fixture, prior to the grease interceptor. Sediment entering the waste line is likely to clog the interceptor's flow restrictor, slowing drainage, and causing back-up difficulties. Extension (-E) - Increases invert dimension to accommodate below grade piping. Heavy Duty Traffic Cover (-HD) - Rated 10,000 lbs. maximum safe live load. Flange & Clamp Device (-FC) - Secures floor membrane or liner, generally specified for above grade installations. Flow through an interceptor is regulated by the flow restrictor. Increasing connection sizes has no beneficial effect on flow, and larger piping can normally be accommodated with reducing bushings or couplings. a.) Interceptors should be located as near as possible to the fixture(s) being served. Long piping runs between a fixture and the interceptor will accumulate grease, causing drainage and clogging problems. b.) Watts Drainage Grease Interceptors may be either floor mounted, under or beside the sink, or recessed, to allow passage of foot traffic, or connect to floor drain discharge. c.) Interceptors may be installed outside, but all piping must be below the frost line (see Extensions). d.) WD Series Interceptors are supplied with an external flow restrictor, which must be installed between the last fixture serviced, and the inlet of the interceptor. e.) Venting is recommended on both the inlet and outlet side of the interceptor, or as governed by local code. Units supplied with external flow restrictors are vented on the inlet side, from the top of the restrictor tee. Manual operation grease interceptors are cleaned by opening the cover, and removing grease accumulated at the top of the interceptor. Accumulated grease may be removed manually, or pumped out, generally by an outside service. Cleaning frequency is dependent upon the interceptor's capacity, and the amount of incoming grease. The amount of accumulated grease must be kept below the rated capacity to maintain separation efficiency. S-WD-INTER-5 0812

TYPICAL GREASE INTERCEPTOR INSTALLATIONS INTERCEPTORS VENT FLOW CONTROL TEE WD Series WASTE FLOW CONTROL TEE OUTSIDE WALL VENT BOLT-ON EXTENSION WD-E Series WASTE VENT FLOW CONTROL TEE DRAW-OFF HOSE WD-AH Series SHUTOFF VALVE WASTE S-WD-INTER-6 0812

OIL INTERCEPTORS Watts Drainage Oil Interceptors are designed to separate oily waste from interior drainage systems, or exterior run-off areas. Commonly specified in service stations and other vehicle maintenance or parking areas, oil interceptors prevent environmentally damaging and potentially dangerous oily substances from entering septic fields, run-off areas, and waste water treatment facilities. Similar to grease interceptors in operation, oil interceptors accumulate lighter-than-water oily waste above the static water line inside the interceptor. Oil is automatically drained from the interceptor through a draw-off valve, and directed to an approved holding tank (by others), for storage and eventual removal. Epoxy Coated Steel - Interceptor body standard 11 ga. CR steel, with oven cured, acid resistant baked gray epoxy coating, inside and out. Lid is epoxy coated 1/4" skid-proof checker plate steel, gasketted, and secured with Allen head center bolt(s). All stainless steel construction may be specified for non-standard applications. Flow Restrictor - Oil interceptors are supplied with a built-in stainless steel flow restrictor plate, just inside the inlet. Oil Interceptors are sized according to the rate of incoming flow, in gallons per minute (GPM). For indoor applications, flow rate can be calculated by adding the maximum discharge rates of all potential water sources. For example, a standard 3/4" hose connection will discharge approx. 10 GPM. A service garage with three hose connections would have a maximum potential flow rate of 10 GPM x 3, or 30 GPM. For outdoor applications involving rainwater run-off, flow rate should be derived from local rainfall tables, and the slope characteristics of the area to be drained. No Hub (Standard) - Butt connection using no hub or neoprene coupling, suitable for cast iron, plastic, and most other piping applications. Threaded (T) - Female IPS threaded connections. S-WD-INTER-7 0812

OIL INTERCEPTORS Commonly Specified Options Sediment Bucket (-B) - Epoxy coated steel, located inside interceptor on inlet side. Collects sediment or other particles. To the extent possible, sediment should be collected with a catch basin (see Watts FD- 410), prior to the oil interceptor. Sediment entering the interceptor may clog the flow restrictor, slowing drainage, and causing back-up difficulties. Extension (-E) - Increases invert dimension to accommodate below grade piping. Heavy Duty Traffic Cover (-HD) - Rated 10,000 lbs. maximum safe live load. Flange & Clamp Device (-FC) - Secures floor membrane or liner, generally specified for above grade installations. Inlet & Outlet Other Than Standard Size (-O) - Flow through an interceptor is regulated by the flow restrictor. Increasing connection sizes has no beneficial effect on flow, and larger piping can normally be accommodated with reducing bushings or couplings. a.) Watts Drainage Oil Interceptors are commonly recessed, to connect to floor drain discharge, and allow passage of foot traffic. b.) Provisions must be made to connect the oil interceptor draw-off to an approved underground oil storage tank (by others). Where conditions permit, a manual draw-off valve (by others) may be installed. A manual valve is generally accessed inside a pit, which houses the oil interceptor. c.) Interceptors may be installed outside, but all piping must be below the frost line (see Extensions). d.) Vent lines should be attached to dual no hub vent connections on the side of the interceptor. The lines must be terminated outside the building, 12" apart in elevation, to allow circulation, and vent heavierthan-air fumes that may accumulate inside the interceptor. The inlet side piping should also be vented through the roof, or as governed by local code. Oil interceptors are not designed to store oil. Oil should be drained into an approved storage tank, which should be pumped as required. If a manual valve is used, oil should be drawn off on a regular basis, dependent upon the amount of incoming effluent. The interceptor lid should be removed periodically, and a visual inspection made, for sludge or other accumulations. VENT STACKS EXTENDS THROUGH ROOF TYPICAL FLOOR DRAINS OIL INTERCEPTOR TO SEWER SERVICING CONNECTION TO GRADE GRAVITY DRAW-OFF OIL STORAGE TANK (BY OTHERS) S-WD-INTER-8 0812

TYPICAL OIL INTERCEPTOR INSTALLATIONS INTERCEPTORS VENT (TO OUTSIDE) FLOOR DRAIN TO SEWER DRAW-OFF CONNECTION WITH VALVE (BY OTHERS) OI Series VENT CONNECTION THROUGH ROOF TRENCH DRAIN GROUND LEVEL ACCESS TO SEWER UNDERGROUND OIL STORAGE TANK (BY OTHERS) OI-E Series CONCRETE SLAB S-WD-INTER-9 0812

SEDIMENT INTERCEPTORS Watts Sediment Interceptors are designed to separate heavier-than-water sediments or floating debris, such as hair or lint, from plumbing waste systems. Sediment interceptors trap debris with a combination of screening, and gravity separation for heavier-than-water sediments. Debris is accumulated inside the interceptor, where it is stored until removal. Epoxy Coated Cast Iron - Industrial grade cast iron, finished with Watts standard gray acid resistant epoxy coating. Epoxy Coated Steel - Standard 11 ga. CR steel, with oven cured, acid resistant baked gray epoxy coating. Stainless Steel - 14 gauge, in accordance with ASTM A-351-Grade CF8 (type 304) Standard Specification. Highly durable and resistant to corrosion. Sediment interceptors are sized according to rate of flow, or anticipated amount of debris. See specification pages for specific flow rates and sizing. No Hub (Standard) - Butt connection using no hub or neoprene coupling, suitable for cast iron, plastic, and most other piping applications. Threaded (T) - Female IPS threaded connections. a.) Sediment interceptors should be located as near as possible to the source of the debris. Long piping runs prior to the interceptor will accumulate debris, causing drainage and clogging problems. b.) Small capacity sediment interceptors are generally mounted under or beside the sink. Larger capacity interceptors may be floor mounted, or recessed, to allow the passage of foot traffic, or connect to floor drain or other discharge lines. c.) Interceptors may be installed outside, but all piping must be below the frost line (see Extensions). d.) Venting of sediment interceptors is generally not required, however installers should reference local codes prior to installation. Sediment interceptors must be routinely inspected and cleaned, in order to prevent clogging, and maintain operating efficiency. Maintenance frequency is primarily dependent upon the specific application, and amount of incoming debris. S-WD-INTER-10 0812

TYPICAL SEDIMENT INTERCEPTOR INSTALLATIONS INTERCEPTORS SI-742 SI-750 COMMERCIAL WASHERS FIRST FLOOR LI-800 LI-800 TO SEWER BASEMENT FLOOR S-WD-INTER-11 0812