Mezzanine. Technical manual



Similar documents
BETONYP building boards. The modern way of living.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

How To Make An Oriented Strand Board

B. Related categories: The following categories contain requirements that relate to this section:

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Report Number BTC 17755F

SmartPly OSB3 SMARTPLY

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Chapter 2 Basis of design and materials

Product Data Sheet ROCKPANEL Rockclad

Post and Beam Construction

How To Install Hardwood Flooring

Euro Oak Installation

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

CHAPTER 6 CONSTRUCTION TYPES

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

A few inches will give your business room to grow...

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Structural fire design Eurocode Timber structures

December J-Ply Roofing, Flooring and Decking

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

User guideline NORTEC sonic

How to Install Hardwood Flooring Over a Sub Floor

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Hanson Building Products. precast basement solutions

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

INSTALLATION IMPORTANT INSTALLER/OWNER RESPONSIBILITY TOOLS & EQUIPMENT NEEDED FOR INSTALLATION PRE-INSTALLATION PROCEDURES & JOBSITE CONDITIONS

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Care and Maintenance for Wood Flooring

Rockwool Flexi Insulation Application Guide

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Understanding BS EN 771-3: Aggregate concrete masonry units

39HQ Airovision Air Handling Units

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

Squash Court Design general points

Light-Weight Panels. High quality panels.

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Caberboard. The UK s No.1 particleboard. Caberfloor P4 Caberfloor P5 Caberdek Caberdek fixing packs.



MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

K2 STONE NATURAL VENEER

Cupped Floor STEP 1. Flooring absorbing excessive moisture on the underside causes expansion and cupping with the edges raised.

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

The University of Birmingham (Live System)

Designed for comfort and built to last.

Aluminium systems profile selection

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Fire safety in timber buildings

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

TECHNICAL RESOURCE SHEET. Proper installation of a floor system is the most effective preventive measure against annoying squeaks.

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

pinta ACOUSTIC PANEL [1/7]

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

DIY CABINET REFACING INSTALLATION GUIDE

Polymeric membrane for roof waterproofing

Saferand easierinstallation

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

OWNER S MANUAL FOR THE PATIO SAUNA

TECHNICAL INFORMATION SHEET

EN Export Manager Pulastic Sports Surfaces The Netherlands

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

If stepping is required, step at 180mm as seen in this picture.

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Isola Steel Gutters Strength and design for extreme climate!

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Timber Decks. Technical Note. March 2007

Product Guide Specification

Removable Aluminium posts

PART 1 GENERAL 1.1 SECTION INCLUDES

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

PanelTack. For the bonding of steni Colour type 7 façade panels. steni Colour 7. steni Colour 7

Façade panels for interior cladding on a wooden supporting structure

Dubai Municipality Standard DMS 1: Part 5: 2004

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Code of Standard Practice for Timber Frame Structures

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

COMMERCIAL BUILDING APPLICATIONS

Featuring TJ Rim Board and TimberStrand LSL

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Installation instructions for all Egger floors with the glueless system JUST clic!

H-Stud Area Separation Wall System

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Design guide. Part 1: Structural Design

Transcription:

TechNICAL MANUAL 1 Mezzanine Technical manual

2 Varnished (optional) Product class P6 Melamined (optional) Tongue and groove Structural applications STANDARD FEATURE additional options - Chipboard - Varnished (optional) - P 6 Product class P6 - Melamined (optional) - Structural applications - T&G Tongue and groove (T&G)

3 Introduction Mezzanine floors are often installed in spaces with high ceilings to increase the floor surface area. Having a self-supporting floor framing means you can add one or more floors. These floors can serve as storage spaces, office spaces, control rooms or walkways. With the Mezzanine product range, UNILIN is offering a broad, cost-efficient choice of mezzanine boards. Due to their high load-bearing capacity, Mezzanine products are also suited for traditional applications in offices, retail spaces or prefabricated unit construction. Mezzanine: high quality floors UNILIN developed especially for Mezzanine a 38 mm thick high density U7 chipboard (690 kg/m2, with a tolerance of +/-7%) to serve as a base board. This board consists of a highly compacted core and strongly bonded coatings. Mezzanine U7 is a P6 board with improved strength properties. This CE certified, P6 class EN 312 board by far exceeds the technical strength and stiffness requirements set by the P6 standard, making it the basis for a robust and reliable floor. As a result, Mezzanine U7 boards are able to bridge greater distances between support beams than conventional P6 boards. The savings achieved in terms of materials make fitting mezzanine floors more cost efficient. The base boards for Mezzanine are internally produced by UNILIN and, if necessary, are given a finishing coat. The ISO 9001 quality assurance system is your guarantee of a continuous quality and durable finished product. Mezzanine U7 is available as standard in a 38 mm thickness. Other thicknesses and types (e.g. P5) are also available on request. For more information on the technical possibilities, please contact us via info.panels@unilin.com. Mezzanine

4 Types UNILIN offers a wide range of mezzanine floors: Mezzanine Standard Standard mezzanine floor board, with highly compacted and unfinished chipboard in the top layer. A further finish can be given to the top layer in the form of a thin floor covering (PVC, vinyl, carpet or metal plate). Mezzanine Standard White Standard mezzanine floor board, finished with a UV-cured, white lacquer on the underside. Suitable for higher light values and a professional finish in the space under the floor. Mezzanine Deluxe Mezzanine floor board with wear-resistant melamine finish. During the pressing process, these panels achieve a specific structure that ensures a slip-resistance rating of R10. The reverse is finished with a white melamine layer, suitable for higher light values and a professional finish in the space under the floor. Mezzanine Antislip Mezzanine floor board with a distinct grey textured surface. An enhanced slip-resistance rating (R12) is achieved because of the deep texture, making Mezzanine Antislip suitable for high traffic areas. The reverse is finished with a white melamine layer, suitable for higher light values and a professional finish in the space under the floor.

5 T&G Tongue and groove profile The Mezzanine boards are available in TG4 or TG2 long edges. As a standard, we supply boards with an F-profile, but other T&G profiles are also available on request. Standard F-profile - 38 mm: Assembly of the floor with the F-profile is fast and professional, achieving maximum strength for both distributed and concentrated load. Other possible profiles T-profile - 38 mm: The T-profile is a reversible profile. G-profile - 38 mm: 4.2 15 G-profiles feature a groove in which a loose tongue can be placed. UNILIN can supply matching 3,6 mm HDF tongues with the boards. 15 TG2 boards can be supplied on request. Once the mezzanine boards are installed, a small expansion joint is visible on the underside of the mezzanine panels. Mezzanine

6 Technical properties The load-bearing capacity of a floor is determined by the strength and rigidity of the support structure, together with the performance of the boards and their connection profile. A load-bearing floor must meet the requirements for both strength and deflection. On the one hand, the floor must be sufficiently strong to withstand all the forces applied to it and, on the other, it should not sag excessively under its own load and variable load. Technical properties of Mezzanine U7 (38mm) The table below shows that the Mezzanine U7 has a better modulus of elasticity, flexural strength and tensile strength than standard P6 boards. 5/95 percentile values Unit Reference Mezzanine U7 Standard P6 (38 mm) according to EN312 Bend strength n/mm² EN 312-chart 9 15 14 Modulus of elasticity n/mm² EN 312-chart 9 2600 2200 Tensile strength n/mm² EN 312-chart 9 0,35 0,3 Thickness swelling, 24h % EN 312-chart 9 14 14 Typical calculation/design values Unit Reference Mezzanine U7 (38 mm) Strength - traction f t n/mm² EN 12369-1 7,8 Strength - pressure f c n/mm² EN 12369-1 11,9 Strength - bending f m n/mm² EN 12369-1 11,7 Strength - panel shear strength f y N/mm² EN 12369-1 6 Strength - roller shear strength f r N/mm² EN 12369-1 1,7 Stiffness - traction E t n/mm² EN 12369-1 1800 Stiffness - pressure E c n/mm² EN 12369-1 1800 Stiffness - bending E m n/mm² EN 12369-1 3100 Stiffness - shear displacementmode G v N/mm² EN 12369-1 900 Concentrated load The Mezzanine U7 floors have been tested by TCHN Brussels to the EN 1195 standard, which stipulates the authorised concentrated load and soft body impact. A 50mm by 50mm stamp is used to apply the concentrated loads. Span (mm) 500 600 700 800 900 Long duration; Ψ 2 = 0.3 5.5 5.2 4.8 4.5 4.0 Long duration; Ψ 2 = 0.6 5.5 5.2 4.8 4.0 3.0 Medium duration; Ψ 2 = 0.3 7.7 7.2 6.7 5.2 4.0 Medium duration; Ψ 2 = 0.6 7.2 6.7 6.2 4.4 3.0 convert kn into kg: 1 kn corresponds to 100 kg Ψ 2 : Eurocode correction factor for variable load Accumulated duration of characteristic load amounts to 6 months to 10 years for a long duration, 1 week to 6 months for a medium duration

7 Soft body impact Mezzanine U7 (38 mm) meets the requirements of the EN 12871 standard for a floor with impact class 1. Uniformly Distributed Load (UDL) The load tables for uniformly distributed load are based on: criteria EN 12871, i.e. deflection of min. {span/100; 6} mm, in which a deflection of the beam distance/100 is allowed, with a maximum of 6 mm; deflection criteria of min. {span/200; 3} mm, in which a deflection of the beam distance/200 is allowed, with a maximum of 3 mm. Authorised uniformly distributed load qk (kn/m2) Mezzanine U7, 38mm (3 support beams) Span (mm) 400 500 525 600 700 800 900 Not glued; long duration ; min. {span/100; 6} 90.0 45.0 40.5 26.0 16.0 11.0 7.5 Not glued; long duration ; min. {span/200; 3} 80.0 40.0 36.5 24.0 12.5 7.0 4.5 convert kn into kg: 1kN corresponds to 100kg. The specified technical characteristics and permissible load values of Mezzanine boards are based on a sound design for the support structure and its components, proper placement of the boards and suitable environmental conditions. Technical support You can rely on UNILIN for all the additional technical support. You can also contact us for information about concentrated loads and spans for different thicknesses and types. Please contact us at info.panels@unilin.com if you have any questions. Reaction to fire Mezzanine U7 boards were tested for their reaction to fire according to the EN ISO 9239 (Flooring Radiant Panel test). This test simulates the conditions experienced by flooring in a room or escape route during the early stages of a developing fire in an adjacent room. The upper side of the floor boards is hereby subjected to thermal radiation and a flame front. The classification for reaction to fire and smoke production is carried out according to EN 13501-1 and is an important indicator for the potential evacuation in case of a fire. Mezzanine U7 boards are CE certified and are in the following fire reaction classes: Mezzanine U7 Standard/Standard White (38 mm): C fl-s1 Mezzanine U7 Deluxe (38 mm): C fl-s1 Mezzanine U7 Antislip (38 mm): B fl-s1 Mezzanine

8 Installing of floors Storage and processing Mezzanine floor boards should be stacked horizontally in packaging and in a dry environment. Use spacers or pallets to avoid direct ground contact. If there is a risk of a damp ground surface, a waterproof foil should be placed before the packs are stacked up. The storage place should be dry and well ventilated. An average relative humidity of 50 % ensures a moisture content of between 7 and 9 % in the panel. The boards should be delivered at the building site at least one week or more before processing to allow the wood panels to adapt to the surrounding atmosphere. Make sure that the site conditions are not critical in terms of exposure to moisture, rain or sun. Like all wood products, Mezzanine will also react to changes in humidity, resulting in possible dimensional changes and internal stresses in the panels. The best way to limit dimensional variations is to stock and install the floor panels at a moisture content level that is as close as possible to the expected final moisture content. Support structures Mezzanine boards can be mounted on a metal or wooden support structure. This support structure must be assembled in such a way that the upper surfaces are flush. Wooden joists must be dry and have a moisture content below 18%. If the wooden joists are too wet during assembly of the floor, this may cause the floor to warp or crack over time. If the open space under the floor is at risk of reaching higher humidity levels, this space must be adequately ventilated. Poor ventilation will result in a build-up of moisture in the panel, which can lead to reduced structural strength and to the formation of mould. A vapour barrier between the support structure and the mezzanine floor is therefore recommended. The choice of girder plate must be adapted to the current service class. Fitting pattern The boards should be placed in a staggered direction and transverse to the joist. The centre-to-centre distance of the joists should always be a portion of the panel length. This makes it possible to place the panels in such a way that all the short sides are supported. Maximum load bearing capacity is achieved for the floor system as a result. Mezzanine boards can, however, also be positioned on short sides without the support, unless the short side consists of a straight board. Also, in such a situation, the strong F-profile will allow a high load-bearing capacity for both distributed and concentrated loads. Every floor panel should be supported by at least three joists. If this is not possible (e.g. in an end piece), additional support is recommended under the edges.

9 Fastening Mezzanine boards are secured to the underlying structure with screws. When positioned, panels should not be pushed against each other with great force. The choice of fasteners is determined by the type of support structure. When the floor board is supported by a metal a structure, self-tapping screws or other suitable fasteners should be used in accordance with the manufacturer s guidelines. The length of the screws must be at least twice the thickness of the panel and their diameter at least 0.2 times the panel thickness. The screws should be at least 25 mm from the edge. A distance of at least 15 mm is recommended in the case of a straight edge. In order to avoid damage, make sure that the screws do not protrude above the floor surface. In the edge areas, the screws should be spaced 150 mm apart, unless otherwise required by structural calculations. A spacing of 300 mm is sufficient at the level of the intermediate beams. The edge areas of the floor should be supported by an underlying structure. It is possible to glue the tongue and groove joint together to increase the strength of the floor and avoid possible squeaking. Always use an adhesive suitable for joining wood sections. Expansion joints Wooden floor boards can expand or shrink slightly due to variations in humidity. Expansion joints should be provided in order to absorb these variations. Along the floor perimeter and next to solid walls, bearing columns and other objects, a minimum gap of 10 mm should be left. Additional expansion joints of 20 mm are required for floor measurements in excess of 10 metres. When installing additional expansion joints, the support must be ensured by inserting an additional joist for example. Mezzanine

10 Finish and maintenance It is possible to sand Mezzanine boards supplied with an unfinished surface to remove any slight level differences or to prepare the surface for any further finish. During sanding ensure proper dust extraction and subsequently remove all loose dust particles. You should examine the following points before an additional layer is applied: Elasticity of finishing coat: for rigid materials, an intermediate layer (e.g. PE film) is recommended; Load-bearing capacity of the floor framing; Flatness and closeness of the load-bearing floor: it might be necessary to re-sand and fill up seams; Avoid direct contact with water when applying the finishing coat: A technical solution must be provided to prevent water ingress. Clean the mezzanine floors with a damp cloth or mop. Stubborn stains can be removed with suitable cleaning products. Certificates Mezzanine floors are supplied with the following certificates: ISO 9001 CE Fire certificate with EXAP report UNILIN, division panels is actively engaged in sustainable forest management. Mezzanine is therefore also available with PEFC and FSC labels on request. Dimensions and stock inventory Mezzanine floors are directly available in the following dimensions: Mezzanine U7 Dimensions (mm) 2400 x 600 Standard Standard White Deluxe Antislip Thickness (mm) 38 mm Raw Raw Wear resistant antislip - - - - Raw White acrylic lacquer White melamine White melamine 25 25 25 25

Mezzanine 11

UNILIN, division panels UNILIN, division panels is part of the UNILIN group. Ever since our inception in 1960 we have grown into an international player, providing solutions to the construction industry, the furniture sector and interior design. UNILIN is synonymous with (r)evolution. Our divisions, through ongoing investments in design, technology, research and development, have become leaders in their respective segment. Drawing from a strong vertical integration, from tree to finished product, driven by creativity and with innovation as our incentive, we develop solutions tailored to your needs. Ingelmunstersteenweg 229, 8780 Oostrozebeke - Belgium T +32 56 66 70 21 - F +32 56 66 82 25 info.panels@unilin.com - www.unilinpanels.com 07/2015