Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve



Similar documents
Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Type 3353 Angle Seat Valve

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Self-operated Temperature Regulators Temperature Regulator Type 1u

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Series 3240 Globe Control Valve Type 3241 (241) Pneumatic Control Valves Type 3241/3271 (241-1) and Type 3241/3277 (241-7)

Kämmer Series Laboratory Valves

Type and Type Pneumatic Control Valves. Type (left) and Type (right) Mounting and Operating Instructions EB 8026 EN

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

QLM and QLD Series Three-port Control Valves

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Baumann Little Scotty Bronze Control Valve

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Fisher GX Control Valves

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Fast closing valve Series 75

Baumann 24000SB Barstock Control Valve

Pressure transmitter For general industrial applications Model A-10

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

GS-General Service Control Valves

FlowPak TM General Application Valve 1/2-4, Class 150

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Type 92S Pilot-Operated Steam Regulator

Fisher 657 and 667 Diaphragm Actuators

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Baumann Way Bronze or Stainless Steel Control Valve

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

Solenoid Valve Type 3962

Assisted lift operated 2/2-way solenoid valves Type EV250B

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Valve systems Base plates, according to standard ISO Brochure

Baumann Mikroseal Control Valve

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Series 3730 Type Electropneumatic Positioner

Solenoid Valve Island Type 3965

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

REGULATORS D& HD Series

VAD. Variable Area Desuperheaters

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

SD SEVERE DUTY CONTROL VALVES BULLETIN 1149 JULY 2002

VG2000 Series Cast Iron Flanged Globe Valves

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

Competence in Functional Safety MANUAL. Functional safety of globe valves, rotary plug valves, ball valves and butterfly valves

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Specification Data CM /10. Putting You In Control Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves

Type overview. Technical data

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

API Flanged Safety Relief Valves Series 526 CATALOG

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MFP14, MFP14S and MFP14SS Automatic Pumps

CSF16 and CSF16T Stainless Steel Steam Filters

Flanged and Butt-= Weld Type

TABLE OF CONTENT

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Stainless steel process fittings

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Richter Twin Piston Quarter-turn Actuators

Micro Motion Model D and DL Coriolis Flow and Density Meters

2- and 3-port valves with flanged connections, PN 10

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Compact pressure switch Flameproof enclosure Ex d Model PCA

Stainless Steel Valves For the Sanitary Industries

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Overview of the. measurement and control technology range

KF Needle & Gauge Valves

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

SISTO-16TWA/HWA/DLU. Type Series Booklet

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BUTTERFLY VALVES API 609 WAFER LUG U-SECTION BODY STYLE DIAPHRAGM VALVES EN13397:2000 WEIR BODY STYLE

PRESSURE REDUCING CONTROL VALVE

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Line-Mounted Valves L Series

Baumann Flexsleev Sanitary Control Valve

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Threaded Resistance Thermometers Model TR10-D, Miniature Design

VAD Variable Area Desuperheaters

Instruction Manual Differential Pressure Transmitter

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Check Valves & Actuated Valves

Control- and feedback head for integrated mounting on Robolux valves Type 2036

On-off valves MS-EM/EE, MS series, NPT

A global supplier of quality instrumentation/piping specification valves through product design and reliability for total customer satisfaction

RUBBER SLEEVE KNIFE GATE VALVE

4 Posiflow Proportional Solenoid Valves

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Sporlan V-Series Ruby Seat Solenoid Valves

Transcription:

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research facilities Valve size G, NPT and Rc female thread in 1 / 8" ¼" 3 / 8" ½" ¾" Flanges, welding ends Pressure rating Class 150 to 2500 Temperatures 196 to +450 C 325 to +842 F Type 3510 Micro-flow Valve with Type 3271-5 Pneumatic Actuator Type 3277-5 Pneumatic Actuator Available as Globe valve Angle valve Valve body made of G, NPT or Rc female thread Welding ends or flanges Stainless steel is used as the standard body material. However, a wide variety of special materials can also be used on customer request. A mounting kit (1400-9031) provides the valve with an interface according to IEC 60534-6-1 (NAMUR) for attachment of positioners, limit switches, solenoid valves and other valve accessories. We recommend using an insulating section or bellows seal for flanged valves to provide more space to mount valve accessories. Standard version For temperatures from 14 to 428 F ( 10 to +220 C) Class 150 to 2500 Globe or angle valve Female thread G 1 / 8, G ¼, G 3 / 8, G ½, G ¾ or 1 / 8 NPT, ¼ NPT, 3 / 8 NPT, ½ NPT, ¾ NPT or Rc 1 / 8, Rc ¼, Rc 3 / 8, Rc ½, Rc ¾ Flanges NPS ½, ¾, 1, Class 150 to 2500 Welding ends NPS ½ and NPS 1 with welding-neck ends Type 3510 1 With Type 3271 5 Pneumatic Actuator (120 cm²) See Data Sheet u T 8310 1 Type 3510 7 (Fig. 1 and Fig. 2) With Type 3277 5 Pneumatic Actuator (120 cm²) for integral positioner attachment See Data Sheet u T 8310 1 Fig. 1: Type 3510-7 Control Valve with Type 3725 Positioner Further versions Fig. 2: Type 3510-7 Control Valve with Type 3767 Positioner Insulating section for temperatures from 325 to +842 F ( 196 to +450 C), with special material up to +1200 F (+650 C) Metal bellows seal up to Class 1500 with a sealing performance of 10-5 (mbar l)/s Handwheel Electric actuator On request Stainless steel actuator for ambient temperatures down to 76 C ( 60 C) On request Associated Information Sheet T 8000-X Edition October 2015 Data Sheet T 8091-1 EN

Principle of operation The medium flows through the micro-flow valve in the direction indicated by the arrow. The plug position determines the cross-sectional area between the seat and plug. The plug stem is connected to the actuator stem by the stem connector and sealed with an adjustable packing. To comply with stricter environmental emissions requirements, the valve can be equipped with a double-walled metal bellows. The anti-rotation fixture prevents a loosening of the screw connection between the valve body and the bonnet or the intermediate piece. Fail-safe position Depending on how the springs are arranged in the pneumatic actuator (u T 8310 1), the valve has two different fail-safe positions. Actuator stem extends (fail-close) The valve is closed upon air supply failure. Actuator stem retracts (fail-open) The valve is opened upon air supply failure. Fig. 4: Type 3510-7 Control Valve 9 9 10 Fig. 3: Type 3510 Valve, angle valve with insulating section Fig. 5: Type 3510 Valve, globe valve with metal bellows seal Legend 1 Valve body 5.1 Body gasket 9 Intermediate piece for insulating section or bellows seal 2 Seat 6 Plug stem 10 Metal bellows 3 Plug 7 Stem connector 13 Anti-rotation fixture 4 Packing 8 Actuator 5 Valve bonnet 8.1 Actuator stem 2 T 8091-1 EN

Table 1: Technical data for Type 3510 Connection Female thread Welding ends Flanges Valve size G 1 /8 G ¼ G 3 /8 G ½ G ¾ 1 /8 NPT ¼ NPT 3 /8 NPT ½ NPT ¾ NPT Rc 1 /8 Rc ¼ Rc 3 /8 Rc ½ Rc ¾ Pressure rating Class 150 to 2500 Seat/plug seal Characteristic NPS ½ NPS 1 NPS ½ NPS ¾ NPS 1 Metal to metal Equal percentage with C V 0.012 Linear Quick opening Rangeability 50:1 Lower than 50:1 with < C V 0.12 Temperature range 1) Leakage class According to IEC 60534 4 According to ANSI FCI 70 2 Compliance 1) Higher temperatures on request 14 to 428 F ( 10 to +220 C) With insulating section: 325 to + 842 F ( 196 to +450 C) Metal seal: IV High-performance metal seal: V Table 2: Materials Valve body 1) and valve bonnet 2) A479 A316/316L B 574 N06455 Seat A479 A316/316L 3) Plug A479 A316/316L 3) Packing 1.4122 Stellite B 574 N06455 3) 1.4112 Stellite B 574 N06455 3) PTFE compound Body gasket A479 A316/316L B 574 N06455 Insulating section A479 A316/316L B 574 N06455 Metal bellows seal Intermediate piece A479 A316/316L B 574 N06455 Metal bellows up to Class 1500 1.4571 2.4819 1) Other materials on request 2) Wetted parts 3) Only with C V 0.0012 to 2 T 8091-1 EN 3

Table 3: Available C V coefficients Table 3.1: Overview C V coefficient 0.00012 to 0.0075 1) 0.012 to 0.3 0.5 0.75 to 2.0 2) Rangeability <15:1 15:1 to 50:1 50:1 Seat Ø mm 2 3 4 10 Seat thread 3) M10 x 1 M16 x 1 Plug stem Ø mm 4 4 Rated travel mm 7.5 7.5 1) Seat and plug made only of 1.4122/1.4122, 1.4122/Stellite or Stellite /Stellite 2) Only up to Class 600 3) Trims are only interchangeable within the C V coefficient ranges C V 0.00012 to 0.5 (M10x1) and C V 0.75 to 2.0 (M16x1) due to the different seat threads. Table 3.2: C V coefficients and associated valve sizes Flow coefficient C V 0.00012 Connection Female thread Welding ends Flanges Characteristic Equal percentage Linear G 1 /8 G ¼ 1 /8 NPT ¼ NPT Rc 1 /8 Rc ¼ G 3 /8 3 /8 NPT Rc 3 /8 G ½ G ¾ ½ NPT ¾ NPT Rc ½ Rc ¾ NPS ½ NPS 1 NPS ½ NPS ¾ NPS 1 0.00020 0.00030 0.00050 0.00075 0.0012 0.0020 0.0030 0.0050 0.0075 0.012 0.020 0.030 0.050 0.075 0.12 0.20 0.30 0.50 0.75 1) 1.2 1) 2.0 1) 1) Versions can be used up to Class 600 at the maximum 4 T 8091-1 EN

Table 3.3: Valve selection guide Class 150 to 300 600 900 to 1500 2500 Metal bellows Optional Optional Optional Optional C V 0.00012 0.00020 0.00030 0.00050 0.00075 0.0012 0.0020 0.0030 0.0050 0.0075 0.012 0.020 0.030 Type 3510 Type 3510 Type 3510 Type 3510 0.050 0.075 0.12 0.20 0.30 0.50 0.75 1.2 2.0 Type 3252 Type 3241 Type 3252 Type 3251 Type 3252 Type 3251 Type 3252 Type 3251 3.0 5.0 7.5 12 Refer to the following data sheets for detailed information on the corresponding valves: Type 3241: u T 8015 (DIN) and u T 8012 (ANSI) Type 3251: u T 8051 (DIN) and u T 8052 (ANSI) Type 3252: u T 8053 T 8091-1 EN 5

Table 4: Permissible differential pressures Pressures stated in bar (gauge) Table 4.1: Standard version without bellows seal Fail-close Bench range with actuator area 120 cm² 0.4 to 0.8 0.8 to 1.6 1.7 to 2.1 2.4 to 3.1 Valve size C V coefficient Actuator Δp when p 2 = 0 bar 0.00012 to 0.5 120 cm² 250 400 0.75 to 2.0 1) 120 cm² 35 84 100 Table 4.2: Standard version with bellows seal Fail-close Bench range with actuator area 120 cm² 0.4 to 0.8 0.8 to 1.6 1.7 to 2.1 2.4 to 3.1 Valve size C V coefficient Actuator Δp when p 2 = 0 bar 0.00012 to 0.5 120 cm² 30 72 160 250 0.75 to 2.0 1) 120 cm² 25 68 100 Table 4.3: Standard version without bellows seal Fail-open Bench range with actuator area 120 cm² 0.4 to 0.8 Supply pressure 1.2 2.5 3.5 Valve size C V coefficient Actuator Δp when p 2 = 0 bar Table 4.4: Standard version with bellows seal Fail-open 0.00012 to 0.5 120 cm² 254 400 0.75 to 2.0 1) 120 cm² 36 100 Bench range with actuator area 120 cm² 0.4 to 0.8 Supply pressure 1.2 2.5 3.5 Valve size C V coefficient Actuator Δp when p 2 = 0 bar 0.00012 to 0.5 120 cm² 27 160 250 0.75 to 2.0 1) 120 cm² 27 100 6 T 8091-1 EN

Table 5: Permissible differential pressures Pressures stated in psi (gauge) Table 5.1: Standard version without bellows seal Fail-close Bench range with actuator area 120 cm² 6 to 12 12 to 23 25 to 30 35 to 45 Valve size C V coefficient Actuator Δp when p 2 = 0 psi 0.00012 to 0.5 120 cm² 3675 5880 0.75 to 2.0 1) 120 cm² 515 1235 1470 Table 5.2: Standard version with bellows seal Fail-close Bench range with actuator area 120 cm² 6 to 12 12 to 23 25 to 30 35 to 45 Valve size C V coefficient Actuator Δp when p 2 = 0 psi 0.00012 to 0.5 120 cm² 440 1060 2220 3705 0.75 to 2.0 1) 120 cm² 365 1000 1470 Table 5.3: Standard version without bellows seal Fail-open Bench range with actuator area 120 cm² 6 to 12 Supply pressure 18 36 51 Valve size C V coefficient Actuator Δp when p 2 = 0 psi Table 5.4: Standard version with bellows seal Fail-open 0.00012 to 0.5 120 cm² 3735 5880 0.75 to 2.0 1) 120 cm² 530 1470 Bench range with actuator area 120 cm² 6 to 12 Supply pressure 18 36 51 Valve size C V coefficient Actuator Δp when p 2 = 0 psi 0.00012 to 0.5 120 cm² 395 2220 3705 0.75 to 2.0 1) 120 cm² 395 1470 T 8091-1 EN 7

Table 6: Dimensions Table 6.1: Dimensions for Type 3510 Valve Valve Connection Female thread Welding ends Flanges G/NPT/Rc 1 /8 to ¾ NPS ½ NPS 1 NPS ½ NPS ¾ NPS 1 L 1) L1 1) H1 H4 H2 or flange ØD1 Class 150 Class 300 Class 600 Class 900/ Class 1500 Class 2500 Class 150 Class 300 Class 600 Class 900/ Class 1500 Class 2500 120 cm² Insulating section Bellows seal Class 150 Class 300 Class 600 Class 900/ Class 1500 Class 2500 in 7.25 7.25 7.25 7.25 7.25 mm 184 184 184 184 184 in 7.50 7.75 7.50 7.62 7.75 mm 190 197 190 194 197 in 2.91 8.0 8.25 8.0 8.12 8.25 mm 74 mm 203 210 203 206 210 in 8.50 10.0 8.50 9.0 10.0 mm 216 254 216 229 254 in 10.38 12.12 10.38 10.75 12.12 mm 264 308 264 273 308 in Up to Class 2500 Up to Class 600 Class 1500 3.62 3.62 3.62 3.62 3.62 mm 92 92 92 92 92 in 3.75 3.88 3.75 3.81 3.88 mm 95 99 95 97 99 in 1.33 4.00 4.12 4.00 4.06 4.12 mm 34 mm 101 105 101 103 105 in 4.25 5.0 4.25 4.5 5.0 mm 108 127 108 114 127 in 5.19 6.06 5.19 5.38 6.06 mm 132 154 132 137 154 in 4.80 mm 122 in 10.35 /263 mm 10.35 /263 mm 14.37 /365 mm 3.54 3.94 4.25 mm 90 100 108 in 3.78 4.65 4.88 mm 96 118 124 in 0.90 2) 2) 0.90 2) 0.90 3.78 4.65 4.88 mm 23 mm 2) 23 mm 2) 23 mm 2) 96 118 124 in 4.80 5.20 5.91 mm 122 132 150 in 5.28 5.51 6.22 mm 134 140 158 1) Face-to-face dimensions of flanges according to DIN EN 558 2) H2 = 1.10 or 28 mm when body is made of B 574 N06455 8 T 8091-1 EN

Table 6.2: Type 3271 and Type 3277 Pneumatic Actuators Actuator area cm² 120 Diaphragm ØD in 6.61 mm 168 1) in 2.71 H mm 69 2) in 4.33 H3 mm 110 H5 Thread a Type 3277 in 3.46 Type 3277 mm 88 Type 3271 M30 x 1.5 Type 3277 M30 x 1.5 1) Minimum clearance required to remove the actuator G 1 /8 ( 1 /8 NPT) Table 7: Weights in lbs and kg Table 7.1: Weights for Type 3510 Valve Valve Valve without actuator Optional Connection Class 150 Class 300 Class 600 Class 900/1500 Class 2500 Insulating section Bellows seal Female thread Welding ends Flanges G/NPT/Rc 1 /8 to ¾ NPS ½. NPS 1 NPS ½ NPS ¾ NPS 1 lbs 3.74 4.0 5.8 7.3 8.2 kg 1.7 1.8 2.6 3.3 3.7 lbs 3.74 4.0 7.1 9.3 10.6 kg 1.7 1.8 3.2 4.2 4.8 lbs 3.74 4.0 7.5 10.6 11.5 kg 1.7 1.8 3.4 4.8 5.2 lbs 3.74 4.0 14.4 16.8 19.2 kg 1.7 1.8 5.2 7.6 8.7 lbs 14.4 20 21.7 kg 6.5 9.0 9.8 lbs 1.2 kg 0.5 lbs 1.4 kg 0.6 Table 7.2: Type 3271 and Type 3277 Pneumatic Actuators Actuator Weight. approx. 120 cm² lbs 7.8 kg 3.5 T 8091-1 EN 9

Dimensional drawings ØD H3 ØD H3 H H ØD1 H5 20 L L H1 H4 ØD1 L1 57 L1 L1 L1 L1 SW50 SW46 L H2 L1 Type 3510 7 as angle valve with female thread Type 3510 1 as globe valve with female thread, with bellows seal or insulating section Type 3510 Valve body with flanges and welding ends 10 T 8091-1 EN

Order specifications: Type 3510 Microflow Valve Globe or angle valve Valve size NPS Pressure rating Class Body material According to Table 2 Type of end G, NPT or R C female thread connections Flanges/welding ends Direction of flow Flow-to-open or flow-to-close Characteristic Equal percentage, linear or quick opening Pneumatic actuator Type 3271 5 or Type 3277 5, 120 cm² (see Data Sheet u T 8310 1) Fail-safe position Fail-close or fail-open Process medium Density in kg/m³ and temperature in C or F Flow rate kg/h or m³/h in standard or operating state Pressure p 1 and p 2 in bar/psi (absolute pressure p abs ) (with minimum, normal and maximum flow rate Valve accessories* Positioner and/or limit switch *Mounting kit (1400-9031) required T 8091-1 EN 11

Note: The temperature limits for DIN and ANSI versions are not directly converted temperatures. Specifications subject to change without notice SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 samson@samson.de www.samson.de T 8091-1 EN 2015-12-21 English