SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 YANFENG AUTOMOTIVE TRIM SYSTEMS CO. LTD. China Technical Center No. 1001 North Qinzhou Rd. Shanghai, China 200233 Shao Xiong (Test Center Manager/Local Authorized Representative/Quality Manager) Phone: 86-21-24015455 E-mail: xshao@mail.yf.sh.cn Phil Page (Consulting Technical Manager/Remote Authorized Representative) Phone: 0044 (0)1245-39-5368 E-mail: ppage1@visteon.com Weng JiWen (EMC Lab Technical Manager/Authorized Representative) Phone : 86-21-24015140 E-mail : jweng@mail.yf.sh.cn Jin Peifeng (Deputy Authorized Representative) Phone: 0086-21-24015144 E-mail: pjin@mail.yf.sh.cn Website: www.yf.sh.cn ELECTRICAL (EMC) Valid to: November 30, 2017 Certificate Number: 2603.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following automotive electromagnetic compatibility and other electrical tests: Test Technology: Test Method(s) 1 : Electrostatic Discharge (ESD) ISO 10605 (2001, 2008); CHRYSLER CS-11809, Section 7.0; CHRYSLER CS-11979, Section 7.0; FORD ES-XW7T-1A278-AC (CI 280); FORD EMC-CS-2009.1 (CI 280); FORD FMC1278 (CI 280); GMW 3097 (2006, 2012), Section 3.6; VW TL82466 (2007); VW TL81000 (2013), Section 3.1 RF Conducted Emissions CISPR 25 (2008), Sections 6.2, 6.3; CHRYSLER CS-11809, Sections 5.1, 5.2; CHRYSLER CS-11979, Sections 5.1, 5.2; FORD ES-XW7T-1A278-AC (CE 420); FORD EMC-CS-2009.1 (CE 420); FORD EMC-CS-2009.1 (CE 421); FORD FMC1278 (CE 420); FORD FMC1278 (CE 421); GMW 3097 (2006, 2012), Section 3.3.2; (A2LA Cert. No. 2603.01) 01/12/2016 Page 1 of 4
RF Conducted Emissions (cont.) VW TL965 (2009), Section 5.1; VW TL965 (2012), Section 5.3; VW TL81000 (2013), Section 3.3.5; VW TL81000 (2013), Section 3.3.7; VW TL81000 (2013), Section 3.3.9 RF Radiated Emissions CISPR 25 (2008), Section 6.4; CHRYSLER CS-11809, Section 5.3; CHRYSLER CS-11979, Section 5.3; FORD ES-XW7T-1A278-AC (RE 310); FORD FMC1278 (RE 310); FORD EMC-CS-2009.1 (RE 310); GMW 3097 (2006, 2012), Section 3.3.1; VW TL965 (2009), Section 5.3; VW TL965 (2012), Section 5.4; VW TL81000 (2013), Section 3.3.6 Electromagnetic Immunity to Portable Transmitters of Electronic Components Test Set-up/Location Designation: Semi Anechoic Chamber ISO 11452-9 (2012); FORD FMC1278 (RI 115) Conducted Emissions (Time Domain) ISO 7637-2 (2004, 2011); CHRYSLER CS-11809, Section 5.4; CHRYSLER CS-11979, Section 5.4; FORD ES-XW7T-1A278-AC (CE 410); FORD FMC1278 (CE 410); FORD EMC-CS-2009.1 (CE 410); GMW 3097 (2006, 2012), Section 3.5.1; VW TL82066 (2006), Section 6 Bulk Current Injection (BCI) Substitution Method Absorber-Lined Shielded Enclosure (ALSE) 200 MHz to 3.2 GHz, up to 200 V/meter ISO 11452-4 (2005, 2012); CHRYSLER CS-11809, Section 6.1; CHRYSLER CS-11979, Section 6.1; FORD ES-XW7T-1A278-AC (RI 112); FORD EMC-CS-2009.1 (RI 112); FORD FMC1278 (RI 112); GMW 3097 (2006, 2012), Section 3.4.1; VW TL82166 (2009), Section 6.1; VW TL82166 (2011), Section 6.1; VW TL81000 (2013), Section 3.2.2 ISO 11452-2 (2004); CHRYSLER CS-11809, Section 6.2; CHRYSLER CS-11979, Section 6.2; FORD ES-XW7T-1A2768-AC (RI 114); FORD EMC-CS-2009.1 (RI 114); FORD FMC1278 (RI 114); GMW 3097 (2006), Section 3.4.2; GMW 3097 (2012), Section 6.2; VW TL82166 (2009, 2011), Section 6.2; VW TL81000 (2013), Section 3.2.3 (A2LA Cert. No. 2603.01) 01/12/2016 Page 2 of 4
Absorber-lined Shielded Enclosure (ALSE) Radar Pulse Only (1.2 to 1.4) GHz and (2.7 to 3.1) GHz, up to 600 V/meter ISO 11452-2 (2004); FORD ES-XW7T-1A278-AC (RI 114 Bands 6 & 7); FORD EMC-CS-2009.1 (RI 114 Bands 6 & 7); FORD FMC1278 (RI 114 Bands 7 & 8); GMW 3097 (2006, 2012), Section 3.4.2 Magnetic Fields (PEPS LF) GMW 3097 (2012), Section 3.3.3 Immunity to Power Line Magnetic Fields GMW 3097 (2012), Section 3.4.4; VW TL82566 (2006, 2011); VW TL81000 (2013), Section 3.2.5 Magnetic Fields Immunity FORD EMC-CS-2009.1 (RI140); FORD FMC1278 (RI 140); ISO 11452-8 (2007) Conducted Transient Immunity ISO 7637-2 (2004, 2011); CHRYSLER CS-11809, Section 6.4.1; CHRYSLER CS-11979, Section 6.4.1; FORD ES-XW7T-1A278-AC (CI 220); FORD EMC-CS-2009.1 (CI 220); FORD FMC1278 (CI 220); FORD FMC1278 (CI 221); FORD FMC1278 (CI 222); GMW 3097 (2006, 2012), Section 3.5.2; VW TL82066 (2006), Section 5; VW TL81000 (2013), Section 3.4.4 Coupled Transient Immunity ISO 7637-3 (1995); ISO 7637-3 (2007); CHRYSLER CS-11809, Section 6.4.2; CHRYSLER CS-11809, Section 6.4.3; CHRYSLER CS-11979, Section 6.4.2; CHRYSLER CS-11979, Section 6.4.3; GMW 3097 (2006, 2012), Sections 3.5.3, 3.5.4; VW TL82366 (2008); VW TL81000 (2013), Section 3.4.5 Conducted Immunity (Ripple) FORD ES-XW7T-1A278-AC (CI 210); FORD EMC-CS-2009.1 (CI 210); FORD FMC1278 (CI 210) Immunity to Voltage Fluctuations, Disturbances of the Supply Voltage Lines (Dropouts, Dips, Cranking, Ramp Up/Down) FORD ES-XW7T-1A278-AC (CI 230); FORD ES-XW7T-1A278-AC (CI 260); FORD EMC-CS-2009.1 (CI 230); FORD EMC-CS-2009.1 (CI 260); FORD FMC1278 (CI 230); FORD FMC1278 (CI 231); FORD FMC1278 (CI 260) Immunity to Voltage Overstress FORD ES-XW7T-1A278-AC (CI 270); FORD EMC-CS-2009.1 (CI 270); FORD FMC1278 (CI 270) (A2LA Cert. No. 2603.01) 01/12/2016 Page 3 of 4
Immunity to Ground Voltage Offset FORD ES-XW7T-1A278-AC (CI 250); FORD EMC-CS-2009.1 (CI 250) Supply Voltage for Variation Supply Over Voltage and Reverse Voltage CHRYSLER CS-11979, Section 4.2; CHRYSLER CS-11979, Section 4.3 1 When the date, revision or edition of a test method standard is not identified on the scope of accreditation, the laboratory is required to be using the current version within one year of the date of publication, per part C., Section 1 of A2LA R101 - General Requirements - Accreditation of ISO-IEC 17025 Laboratories. (A2LA Cert. No. 2603.01) 01/12/2016 Page 4 of 4
Accredited Laboratory A2LA has accredited YANFENG AUTOMOTIVE TRIM SYSTEMS CO. LTD. Shanghai, People s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 12 th day of January 2016. Senior Director of Quality & Communications For the Accreditation Council Certificate Number 2603.01 Valid to November 30, 2017 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.