Home Sleep Testing Common Questions and Answers



Similar documents
Update on Home Sleep Studies Is there a Home for Portable Monitoring?

Fits in the palm of your hand. Small and mighty. Stardust II portable diagnostic system

Gold Standard For sleep apnea detection and so much more

Release Notes Easy III Version 3.15 November, 2014

Healthcare Online. Keyhole Touchproof Phone RCA RJ10 RJ11 (dual 1mm) (1.5mm safety) (male) (male 1/8")

Diagnosis and Treatment

Summary of AASM Clinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea - Updated July 2012

HEALTH EVIDENCE REVIEW COMMISSION (HERC) COVERAGE GUIDANCE: DIAGNOSIS OF SLEEP APNEA IN ADULTS DATE: 5/9/2013 HERC COVERAGE GUIDANCE

Advancing medical technology to help you, help others.

Integration of the new miniaturized pneumotachograph for SOMNOscreen plus (Item no.: SEN513)

MODULE. POSITIVE AIRWAY PRESSURE (PAP) Titrations

Changes in the Evaluation and Treatment of Sleep Apnea

Polysomnography in Patients with Obstructive Sleep Apnea. OHTAC Recommendation. Polysomnography in Patients with Obstructive Sleep Apnea

Comparing the Performance and Efficacy of the 3B/BMC RESmart. Auto-CPAP with the ResMed S9 AutoSet

Underwriting Sleep Apnea

Instructions for In-Lab Sleep Study Procedures

Sleep Test Optimization Program Frequently Asked Questions Table of Contents

Treatment of Obstructive Sleep Apnea (OSA)

Perioperative Management of Patients with Obstructive Sleep Apnea. Kalpesh Ganatra,MD Diplomate, American Board of Sleep Medicine

Every Download Tells a Story. Lizabeth Binns PA-C University of Michigan Sleep Center October 2, 2015

Does Depression affect compliance with CPAP therapy in patients with Obstructive Sleep Apnea? Ramesh Metta, MBBS M Jeffery Mador, MD

2015 Physician Quality Reporting System Data Collection Form: Sleep Apnea (for patients aged 18 and older)

DIAGNOSING SLEEP APNEA. Christie Goldsby Florida State University PHY /09/14

Watermark Medical Interpreting Physician Access Manual

Helpful hints for filing

Scoring (manual, automated, automated with manual review)

Diseases and Health Conditions that can Lead to Daytime Sleepiness

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

SLEEP APNEA AND SLEEP Diagnostic aspects. Carin Sahlin

Dental Sleep Medicine

ROLE OF ORAL APPLIANCES TO TREAT OBSTRUCTIVE SLEEP APNEA

Effective Treatment for Obstructive Sleep Apnoea

SLEEP STUDIES AND THERAPY MANAGEMENT

HEALTH RISK ASSESSMENT (HRS) QUESTIONNAIRE

Self-Administered Wireless Monitor for Comprehensive Evaluation of CPAP Benefit in the Home

Clickfree The Effortless Backup Solution

Sleep Apnea. ACP Oct 26, Bashir Chaudhary, MD Sleep Institute of Augusta, Augusta GA

Ambulatory monitoring of EEG with time synchronised video

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Meeting your Healthy Blue Living weight management requirement. If your body mass index is 30 or more, you have two ways to get healthier

Why should our fitness center administer fitness tests?

icode TM Software USER MANUAL

Project 4.2.1: Heart Rate

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

Introduction. Intended use. Contraindications. General warnings and cautions. Patient Instructions WARNING CAUTION. English

Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC

Advancing medical technology to help you, help others.

OARTEC SIMULATOR TRAINING MONITOR USER MANUAL Version 1.05

Night Owl 8 Channel DVR with 1TB HDD, HDMI Output, 8 Hi-Resolution Cameras (2 Audio Enabled) and free Night Owl PRO App

VARTA EasyPack. design-in handbook. The easy way to power portable devices! See also:

FREQUENTLY ASKED QUESTIONS

USB2VGA. Instruction Manual. USB to VGA Adapter. USB 2.0 to VGA External Multi Monitor Video Adapter

Developing a Sleep Domain Ontology

How to interpret your sleep study

Full 1080p Network Video Recorder with 2TB HDD & 8 Night Vision 1080p HD IP Cameras

Rest ECG

USER GUIDE WIRELESS USB TO AUDIO KIT. Model: 29594

About Sleep Apnea ABOUT SLEEP APNEA

Maharashtra University of Health Sciences, Nashik. Syllabus. Fellowship Course in Sleep Medicine

Before You Begin Installing Your Scanner

Digital Video Recorder

4 Ch. HD Network Video Recorder with 1TB HDD, HDMI Output, 4 Night Vision 720p Cameras and Free Night Owl Pro App

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

MixMeister EZ Converter Setup & Troubleshooting Contents:

Operating Instructions

USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter

Nellcor Portable SpO 2 Patient Monitoring System PM10N V1.05 Software Upgrade. Laura DeNuccio February 2015

HEART MONITOR TREADMILL 12 LEAD EKG

NAME: The measurement of BMR must be performed under very stringent laboratory conditions. For example:

Understanding Sleep Apnea

Critical Care Therapy and Respiratory Care Section

User Installation Guide

Lync Web App 2013 Guide

playbook for channel owners. Content Send automated s with minimal effort. Audience Engage your audience at the right times

USB 3.0 Bandwidth, High Definition Performance

Paul Wylie, MD 1, Sukhdev Grover, MD 2 1 Arkansas Center for Sleep Medicine, Little Rock AR; 2 Sleep Center of Greater Pittsburgh, Pittsburgh, PA

Restoring a good night s sleep

Changers Kalhuohfummi User Manual

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

Bluetooth Installation

BASIC BODY COMPOSITION SCALE

Virtual COM Port Driver Installation Manual

NoiseMeters. dosebadge. Monitoring Personal Noise Exposure

Transmitter Interface Program

Treating Sleep Apnea A Review of the Research for Adults

USB Driver INSTALLATION GUIDE 6 NOVEMBER 2013 RIGHT SOLUTIONS RIGHT PARTNER D B

HP Advanced Wireless Docking Station. User Guide

Chord Limited. Mojo Dac Headphone Amplifier OPERATING INSTRUCTIONS

What is Obstructive Sleep Apnoea?

Convenient Accessibility

Sleep Apnea Dr. Douglas Tapper

Transcription:

Home Sleep Testing Common Questions and Answers Suite 1, 100 Schneider Road Kanata, Ontario, Canada K2K 1Y2 Tel: 613.831.6690 Fax: 613.831.6699 braebon.com D.MP8.80200.2 November 2013

I thought BRAEBON was a sleep sensor company? How can BRAEBON help me with Home Sleep Testing (HST)? Yes, we started with sleep sensors but over the past several years BRAEBON has been doing much more than just sleep sensors. In fact, we ve been in the Home Sleep Testing business much longer than most other companies. We took our famous sleep sensor technology and adapted it to work with our own portable recorders in the home. The result is BRAEBON now sells a complete range of top-notch Level 3 & Level 4 Home Sleep Testing equipment. What are the BRAEBON HST devices called? BRAEBON offers two HST devices for recording snoring and sleep apnea: the BRAEBON MediByte is our 12-channel Level 3 HST device and the MediByte Junior is the 6-channel Level 3 / 4 HST version. What s the difference between the MediByte and its sibling, the MediByte Junior? The MediByte is a complete 12-channel Level 3 recorder which exceeds all new home sleep apnea testing guidelines. The MediByte Junior is a 6-channel Level 4 recorder which can be upgraded to a Level 3 device simply by adding one respiratory effort belt. This entry-level Home Sleep Testing device complies with all CMS requirements for either Level 4 or Level 3 Home Sleep Testing. The MediByte records everything the MediByte Junior does, but adds an additional effort channel, a sum channel, an oronasal thermal airflow channel, and an Auxilary port which means you have the option to record more information when using the thermal airflow sensor: ECG, or EMG, or Audio (snoring). What exactly does the MediByte and MediByte Junior record? MEDIBYTE Junior 6 Channels MEDIBYTE 12 Channels Airflow (OroNasal Pressure Cannula) Snoring (OroNasal Pressure Cannula) SpO2 Pulse Rate Body Position CPAP Pressure Event Marker Chest Effort (RIP) Optional Abdominal Effort (RIP) SUM (RIP) Airflow (OroNasal Thermistor) Audio (Microphone) Volume (db) EKG EMG (PLMs, Bruxism) Number of software installations per recorder 1 1 Size World's Smallest Type 3 3 x2.5 x1 63x76x25mm World's Smallest Type 3 3 x2.5 x1 63x76x25mm Weight in grams (including battery) 81 (2.6 oz) 84 (2.7 oz) Location worn during recording Chest Chest Page 2 11/07/2013 1-888-462-4841 x218

What do I get when I buy it? You get everything you need right out of the box. Simply add your own Windows XP or Vista computer with USB port and you are good to go. When you buy the complete MediByte kit you receive a convenient, durable carrying case which includes the MediByte recorder, all needed software with three software licenses, all sensors, USB communication cable, six patient kits and a one-year MediByte warranty. The MediByte Junior comes in a carrying pack about the size of a shaving kit and includes one patient kit. MediByte carrying case MediByte Junior carrying pack How big is the MediByte? The MediByte is the smallest in its class. The small size means better patient comfort and compliance. How easy is it to use the MediByte? The MediByte is one of the easiest Home Sleep Testing devices to use. Simplicity and ease of use is the key to its success. For example, all connectors are unique. This means the patient training and hook-up is much simpler with no likelihood to plug the wrong sensor into the wrong connector on the MediByte. Attaching the MediByte to the computer is simple and uses a standard USB connection just like your digital camera. The software uses a wizard to prepare the MediByte for a patient recording, and to download the data. The oversized event button makes it easy for the patient to use during the recording. After the recording, the data is automatically analyzed and ready for manual review within our full disclosure software. Quite literally, if you can use a computer mouse you can use the MediByte! Page 3 11/07/2013 1-888-462-4841 x218

How long has the MediByte been on the market? BRAEBON has been selling the MediByte since November 2006 and today it is used on five continents. Are patient instructional videos available? Yes, go to http://www.braebon.com/mp8_demo.html to download the MediByte instructional videos. Go to http://www.braebon.com/medibyte_jr.html to download the MediByte Junior video. Can the MediByte record multiple nights? Yes, you can record up to two consecutive 9-hour recordings. In fact, you can choose one 9-hour night, two nights, or one continuous 24-hour recording for EKG. You can also choose to start the recording automatically or manually use the On / Off switch. The ability to record two nights minimizes the firstnight effect, and is also useful for evaluating oral appliance treatment with a baseline night and treatment night. Does the MediByte permit full disclosure? Yes, MediByte software fully complies with new guidelines and permits both full data disclosure and manual scoring. Can I install the software anywhere I like? Yes, you receive three software licenses with your purchase and you can install a copy on any Microsoft Windows XP or Vista computer. Additional software licenses are available for a small fee. Is the MediByte compatible with CPAP? Yes, both the MediByte and MediByte Junior can be connected to any CPAP for recording flow, snoring, and CPAP pressure. Is the technology used in the MediByte the same technology used in sleep laboratories? Yes, because BRAEBON has been selling sleep sensors to sleep laboratories for over ten years, we use the exact same sensors and technology within our family of Home Sleep Testing devices as we supply to world leading sleep laboratories. This means you meet the new Home Sleep Testing guidelines when using the MediByte. It also means the test results can be exchanged and easily understood by any doctor, dentist, or laboratory. With the MediByte, you are practicing medicine at the state-of-the-art. Can I use sensors from other companies with the MediByte? No, to achieve optimal performance with the MediByte you must use genuine BRAEBON sensors. Remember, BRAEBON started in the sleep sensor business and is a recognized leader in this field why use something else? What is the per use cost of running a test with the MediByte? The cost to do a test with the MediByte can be around $8 to $10 Does the MediByte record EEG? No, the MediByte is a snoring and sleep apnea recorder and is not intended for EEG recording. It does not record sleep staging information, but you can record one channel of EKG for up to 24 hours, or one channel of EMG for leg activity or bruxism. Our years of experience have shown us that once EEG is needed for a test, the level of complexity for the patient goes up dramatically. Page 4 11/07/2013 1-888-462-4841 x218

Do I need to hook up the patient and send them home? No, because the MediByte is so easy to use most patients hook themselves up at night in the comfort of their own bedroom. Prior to the test, a sleep technologist or dental assistant would prepare the MediByte for the patient before the patient arrives at the laboratory or office. Once the patient arrives, a brief five to ten minute training session is recommended to demonstrate the recorder to the patient and answer any questions. It is also recommended the patient watch the ten minute MediByte video prior to the actual test. Some sleep laboratories also provide their phone number in case the patient has any questions during the evening of the test. On the night of the test, the patient takes the MediByte carrying case home, uses the MediByte and returns the unit the next day where the technologist or assistant downloads the data for analysis. Can I use rechargeable batteries with the MediByte? No, our experience has been that rechargeable batteries introduce a number of other problems including longer turnaround time, insufficient battery life, and shorter recording time. By using a fresh, new battery for each recording you are improving the likelihood of success. Can I change the reports? You can change the header and footer on the report templates and add your company information, but we generally do not recommend that reports are altered. Has the MediByte been validated? Yes, studies have found both high sensitivity and high specificity and have concluded that more than 4 of 5 patients are diagnosed identically when using the MediByte or when using full PSG in a sleep laboratory. What are some of the billing codes? The following codes are examples where Medicare provides coverage for beneficiaries who use Home Sleep Testing to assist in the diagnosis of sleep apnea: G0398: Home Sleep Testing, Type II portable monitor; minimum 7 channels - $150.00 $100 is recognized for the Professional Component $50 is recognized for the Technical Component G0399: Home Sleep Testing, Type III portable monitor; minimum 4 channels - $125.00 $85 is recognized for the Professional Component $35 is recognized for the Technical Component G0400: Home Sleep Testing, Type IV portable monitor; minimum 3 channels - $100.00 $70 is recognized for the Professional Component $30 is recognized for the Technical Component What if I still have more questions? Call us at 1-613-831-6690 x218 or toll-free in North America at 1-888-462-4841 x218. We re here to help. Page 5 11/07/2013 1-888-462-4841 x218

What does a sample MediByte Junior report look like? Patient Name: Smith, Jack Patient ID: 12345678 Date of Birth: 02/19/1966 Chart Code: 0987654321 Weight: 165.0 lbs Study Date: 11/04/08 Height: 5 9 175 cm Age: 42 BMI: 24.5 Neck Circumference: 16 Sex: Male Waist: 32 Hip: 0 Waist-Hip Ratio: 0.00 Referring Physician: Comments::no comments Total Recording Time(TRT): 292.9 minutes Cardiac Respiratory and Duration (sec.) Min Max Total# Index Avg HR: 48.6 40.0 Snoring Events Mean Min Max HR: HR: 95.0 Central Apneas 10 2.0 26.7 9.9 96.4 Oximetry Obstructive.Apneas 0 0.0 0.0 0.0 0.0 Mean SpO2 97.3% Mixed Apneas 0 0.0 0.0 0.0 0.0 Min SpO2 94.0% Hypopneas 0 0.0 0.0 0.0 0.0 Max SpO2 100.0% SpO2 Range % Minutes Apnea + Hypopnea 10 2.0 26.7 9.9 96.4 90-100 % 100.0% 292.4 80-89 % 0.0% 0.0 Desaturations 0 0.0 0.0 0.0 0.0 70-79 % 0.0% 0.0 60-69% 0.0% 0.0 Snoring 0 0.0 0.0 0.0 0.0 50-59% 0.0% 0.0 < 50 % 0.0% 0.0 Body Position Supine Prone Left Side Right Side Total Non Supine % Time in Position 5.7% 0.4% 37.2% 56.8% 94.3% Snoring events 0 0 0 0 0 Apnea + Hypopnea events 2 0 8 0 8 Apnea + Hypopnea Index 7.3 0.0 4.4 0.0 1.7 BAD BODYPOS RESPIRATORY PULSE SPO2 Total Recording Time: 292.9 minutes Patient Apnea-Hypopnea Index Severe Moderate Mild Normal Jack Smith 2.0 >30 15 to 30 5 to 15 <5 Page 6 11/07/2013 1-888-462-4841 x218

What does a sample MediByte report look like? Patient Name: Smith, Mary Patient ID: 7732767863 Date of Birth: 03/14/1954 Chart Code: 0987654321 Weight: 135.0 lbs Study Date: 07/12/07 Height: 5 4 162 cm Age: 53 BMI: 23.3 Sex: Female Waist: 34 Hip: 30 Waist-Hip Ratio: 1.13 Referring Physician: Comments: Respiratory and Snoring Events Cardiac Oximetry Total# Index Mean Heart Rate 68.7 Mean SpO2 93.5% Central Apneas 6 0.6 Min SpO2 86.0% Obstructive.Apneas 83 8.8 Highest Heart Max SpO2 98.0% 98.0 Mixed Apneas 1 0.1 Rate % Time SpO2 in Range Hypopneas 57 6.0 Slowest Heart 90-100 % 99.6% 57.0 AH 147 15.6 Rate 80-89 % 0.4% Desaturations 56 5.9 70-79 % 0.0% Snoring 3430 363.4 60-69% 0.0% 50-59% 0.0% < 50 % 0.0% Body Position Supine Prone Left Side Right Side Total Non Supine % Time in Position 62.3% 0.0% 17.1% 20.6% 37.7% Snoring events 2363 0 624 443 1067 AH events 131 0 5 11 16 AHI 22.3 0.0 3.1 5.7 4.5 Snoring Volume Table db(a) Body Position Supine Non-Supine Right Side Left Side Prone Min 50.0 50.0 50.0 50.0 - Max 99.9 100.0 100.0 95.4 - Mean 57.6 55.4 55.1 55.9 - BAD BODYPOS RESP PULSE SPO2 VOLUME Total Recording Time: 566.3 minutes Patient Apnea-Hypopnea Index Severe Moderate Mild Normal Mary Smith 15.6 >30 15 to 30 5 to 15 <5 Page 7 11/07/2013 1-888-462-4841 x218

Here is another example Page 8 11/07/2013 1-888-462-4841 x218

Page 9 11/07/2013 1-888-462-4841 x218