Biacore X BIACORE. The versatile high sensitivity system



Similar documents
Characterization of monoclonal antibody epitope specificity using Biacore s SPR technology

Biacore S200. Main applications. GE Healthcare. Label-free interaction analysis

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Review of Chemical Equilibrium 7.51 September free [A] (µm)

Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105

Real-time PCR: Understanding C t

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

EZ Load Molecular Rulers. Catalog Numbers bp bp bp PCR bp kb Precision Mass

Protein Interaction Analysis

Real-Time PCR Vs. Traditional PCR

Effects of Antibiotics on Bacterial Growth and Protein Synthesis: Student Laboratory Manual

2.500 Threshold e Threshold. Exponential phase. Cycle Number

A Novel Bioconjugation Technology

thebiotutor. AS Biology OCR. Unit F211: Cells, Exchange & Transport. Module 1.2 Cell Membranes. Notes & Questions.

HuCAL Custom Monoclonal Antibodies

Viruses. Viral components: Capsid. Chapter 10: Viruses. Viral components: Nucleic Acid. Viral components: Envelope

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Illumina Sequencing Technology

Refractive Index Measurement Principle

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

Introduction to Biosensors. Professor Brian Birch LIRANS University of Luton UK

Essentials of Real Time PCR. About Sequence Detection Chemistries

Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Introduction To Real Time Quantitative PCR (qpcr)

Introduction to flow cytometry

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Content Sheet 3-1: Equipment Management Overview

Gene Expression Assays

Qubit dsdna HS Assay Kits

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

9. Force Measurement with a Strain gage Bridge

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

Authentication of Basmati rice using SSR-PCR and QIAxcel Advanced

Surface plasmon resonance

Rapid GST Inclusion Body Solubilization and Renaturation Kit

Biological cell membranes

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Mass Spectrometry Signal Calibration for Protein Quantitation

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Disaccharides consist of two monosaccharide monomers covalently linked by a glycosidic bond. They function in sugar transport.

Combinatorial Chemistry and solid phase synthesis seminar and laboratory course

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

UV-Vis spectrophotometers

DNA Sequencing Setup and Troubleshooting

Milk protein analysis with the Agilent 2100 Bioanalyzer and the Agilent Protein 80 kit


ab Protein Sumoylation Assay Ultra Kit

Cell Cycle Phase Determination Kit

Appendix 5 Overview of requirements in English

Fraunhofer Institute for Material and Beam Technology

Annexin V-EGFP Apoptosis Detection Kit

Hapten - a small molecule that is antigenic but not (by itself) immunogenic.

TOTAL PROTEIN FIBRINOGEN

Application Guide... 2

GC-xt. The most flexible GC /GC-MS liquid sample injector

BacReady TM Multiplex PCR System

INSTRUCTIONS Edition AC

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

Agilent 4339B/4349B High Resistance Meters

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

EZ-Run Protein Gel Solution. EZ-Run Protein Standards. EZ-Run Gel Staining Solution. Traditional SDS-Page Reagents. Protein Electrophoresis

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Fluorescent dyes for use with the

Lab-on-a-Chip Design + Foundry Service

Agilent Cary 60 UV-Vis

AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

PrepTip. Reverse Phase PrepTip User Guide

GenScript BloodReady TM Multiplex PCR System

BSC Exam I Lectures and Text Pages. The Plasma Membrane Structure and Function. Phospholipids. I. Intro to Biology (2-29) II.

Procedures For DNA Sequencing

Supplementary Materials for

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

A Brief Guide to Interpreting the DNA Sequencing Electropherogram Version 3.0

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

Molecular Cloning, Product Brochure

FIDA for Rapid Detection of Protein Based Biomarkers

JBS FUNDAMENT Thermofluor Screen

Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument

Design of Experiments for Analytical Method Development and Validation

Expression and Purification of Recombinant Protein in bacteria and Yeast. Presented By: Puspa pandey, Mohit sachdeva & Ming yu

HiPer RT-PCR Teaching Kit

Lecture 11 Enzymes: Kinetics

How is genome sequencing done?

FREJA 300 Relay Testing System

0.28" Quadruple Digit Numeric Displays. Technical Data Sheet. Model No.: KW4-281XSB

How to Biotinylate with Reproducible Results

Development and validation of neutralising anti-drug antibody (Nabs) assays

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Transcription:

Biacore X The versatile high sensitivity system Work with high sensitivity Study binding in non-aqueous and aqueous samples Reduce sample consumption Perform the most advanced kinetic evaluation Use proven technology Introduction Biacore X is a high sensitivity, semi-automated system for label free studies of biomolecular binding, in samples ranging from small molecules to crude extracts, lipid vesicles, viruses, bacteria and eucaryotic cells. Biacore X answers questions about the speed, strength and specificity of binding and determines the active concentrations of components. Results are evaluated using the most advanced evaluation software available. Before and after analysis a simulation program can be used to perform dry runs, to test experimental conditions or to verify experimental data, saving time and materials. BIACORE Biacore X is ideal for rapid, single runs and provides accurate sensorgrams smoothly and easily. After loading the sample, the system controls every critical step from sample injection to real time display. Biacore X is designed for laboratory environments where many users handle different types of sample in small numbers. Work with high sensitivity Under standard experimental conditions Biacore X can detect up to 7 RU*, with a relative working range of 1 RU. However these values have been surpassed under fully optimized conditions. This high sensitivity allows the study of samples ranging from small molecules to large surface complexes. *RU: Biomolecular binding events at a sensor surface cause changes in an SPR signal which are expressed in resonance units, RU (one RU is equivalent to one picogram per square millimetre of sensor surface).

elimination of air/liquid interfaces minimizes sample dispersion and protein denaturation Temperature controlled environment analyte/buffer injection point sensor surface for immobilization (2 different immobilizations are possible) Fig. 1. Microfluidic system of Biacore X housed in a temperature controlled environment. flow cells used in series or individually 1 2 2 flow cells over one sensor surface single flow cell.6 µl automatic in-line reference subtraction, from same sample injection, using flow cell 2-1 or 1-2 Measurements of kinetic and affinity parameters are always dependent on the experimental conditions as well as the molecular weights of the binding partners. The microfluidic pathway of Biacore X, shown in Figure 1, incorporates a single sensor surface overlaid by two flow cells, each with a volume of.6 µl. One flow cell can be used as a true reference during a single sample injection. Automatic in-line reference subtraction maximizes the resolution and information from a single run. The reduction of background noise will resolve signals which may not otherwise be observed. Kinetic and concentration measurements can also be improved by studying two surface ligand concentrations in the same run. The controlled environment of the microfluidic flow path of Biacore X, together with the automatic reference subtraction, allow the measurement of small molecules and the measurement of weak binding, as shown in Figure 2. This example shows the binding of maltose (MW 36 Da) to an immobilized antibody with an apparent affinity of 6 x 1-5 M -1. RU 1886 18854 Fig.2. In line reference subtracted data: sequential injections of a maltose (MW 36 Da) concentration series. Results show an injection series beginning with decreasing concentration and followed by increasing concentration. Courtesy of Sten Ohlsson, Kalmar Högskola, Sweden. Response 18848 18842 18836 1883 18824 18818 18812 1886 188 7 14 21 28 35 42 49 56 63 7 Time s Study binding in non-aqueous and aqueous samples Biacore X is used for samples ranging from small molecules to crude extracts, lipid vesicles, viruses, bacteria and eucaryotic cells. It may be necessary, for solubility or stability reasons, to work with specific additives, such as organic solvents or high salt concentrations.

The detection system of Biacore X allows sample measurements over a broad dynamic range to enable the performance of binding studies in a range of solutions, as shown in Figure 3. 7 6 4% glycerol Dynamic range (RU) 5 4 3 6 M urea 2 M MgCl 2 15% DMSO 4% ethylene glycol 15% sucrose Theophylline in 15% DMSO Fig.3. Binding can be studied in a wide range of solutions. 2 Absolute baseline 46, RU 1 HBS 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.4 Refractive index (RIU) Automatic in-line reference subtraction easily eliminates major refractive index effects. Figure 3 also shows an example in which the binding of theophylline (MW 18 Da) to an immobilized antibody is confidently measured despite a high back-ground response generated by 15% DMSO. Reduce sample consumption Samples used in binding studies are often valuable and available only in small quantities. Biacore X is designed to reduce sample consumption whenever possible. Sample injections from as little as 5 µl are required to monitor binding in both flow cells, each flow cell having a volume of.6 µl. By immobilizing a different ligand in each flow cell, the same sample can be used to study binding on two different surfaces, as was done to produce the results shown in Figure 4. Sample flow-through material can be collected during injection and surfacebound sample can be recovered for complementary analysis. The highest quality sensor surfaces minimize non-specific binding. Fig.4. With different proportions of wild-type and competitor DNA sequences immobilized in the two flow cells, PCR products are selectively detected. Response in each flow cell reflects the relative amounts of immobilized DNA species.

Perform the most advanced kinetic evaluation Biacore X includes options for the most advanced kinetic evaluation, and performs affinity or concentration calculations. The global fit functions in BIAevaluation further extend the range for quantitative kinetic analyses. Evaluation Wizards, tool tips and pre-programmed models reduce the need for mathematical expertise and accelerate the evaluation of even the most complex interactions. For more detailed information on BIAevaluation please ask for Product Information Sheet BR-9-85. Use proven technology Biacore X has been used successfully for many different applications and a regularly updated list of publications is available on http://www.biacore.com. Two examples using Biacore X are shown below: Binding of thrombin-activated coagulation factor VIII (fviiia) to phospholipid surfaces is required for assembly of one of the multi-protein complexes involved in the coagulation cascade. Using Biacore X, Saenko et al have shown that the affinity of fviii for phospholipid monolayers increases upon thrombin activation (Figure 5). 3 Fig. 5. Binding of 1 nm each of factor VIII (fviii) and thrombinactivated factor VIII (fviiia) to a phosphatidyl serine/phosphatidyl choline (25/75) monolayer on the surface of Sensor Chip HPA in the presence of 2 nm A2 subunit. FVIIIa has a ten-fold higher affinity than that of fviii. Response (RU) 25 2 15 1 5 fviii fviiia 1 2 3 4 5 Time (s) Traditionally the assembly of multi-protein complexes of coagulation proteins on lipid monolayers has been performed using stopped flow techniques, but Saenko reports several advantages of using a Biacore X, including technical simplicity, no requirement for phospholipid labelling, less sample used and a phospholipid surface that can be re-used to allow straightforward assessment of accuracy and reproducibility. Further details: BIAjournal, Vol. 5, No. 2, p. 29 and J. Biol. Chem., 273, 27918-27926, 1998. DNA-dependent protein kinase (DNA-PK) is the only eukaryotic protein kinase known to be specifically activated by double-stranded DNA (dsdna) termini. This explains the importance of DNA-PK in the repair of dsdna. West et al studied the binding of DNA-PK to DNA termini of various lengths in the presence or absence of Ku (a molecule known to be involved in the activation of DNA-PK). Biacore X was used to monitor the build up of multi-molecular complexes between Ku, DNA-PK and dsdna and to analyze the kinetic events. The authors concluded that for dsdna smaller than 26-bp, DNA-PK is inactive as a kinase despite being bound to Ku:DNA.

However for dsdna above 26-bp the presence of Ku stimulates DNA-PK activity by increasing the stability of the DNA-PK-Ku-DNA complex. Figure 6 shows examples of sensorgrams from this work. Further details: Mol. and Cell. Biol., 18, 598-592, 1998. Resp. Diff. (RU) 4 3 2 1 35-bp oligonucleotide Injection stop DNA-PK injection 1 2 Time (s) 3 Resp. Diff. (RU) 2 15 1 5 18-bp oligonucleotide Injection stop DNA-PK injection 1 2 3 4 Time (s) 5 Fig. 6. Sequential injections of Ku (28.5 nm) and DNA-PK (2.4 nm) over Sensor Chip SA loaded with a 35-bp oligonucleotide (a) or an 18-bp oligonucleotide (b) show the binding characteristics of DNA-PK with the Ku:35 bp DNA fragment and Ku:18-bp DNA fragment respectively. Biacore AB would like to thank the authors of these applications for their kind permission to reproduce this work. For the best results in biomolecular binding studies 1. Control of every critical step 2. Optimized monitoring 3. Advanced evaluation 1. Control Real time display shows binding events, for assessment of kinetics and immediate feedback Step-by-step method development for specialized applications System control ensures that sample and reagents are delivered to the sensor surface in a precise, pulse free flow to give reproducible injections Biacore systems use the phenomenon of surface plasmon resonance (SPR) to monitor biomolecular binding events in real time without the use of labels. SPR occurs when surface plasmon waves are excited at a metal/liquid interface (the sensor surface). Biacore s integrated system

Light is directed at, and reflected from, the side of the surface not in contact with sample. SPR causes a reduction in the reflected light intensity at a specific combination of angle and wavelength (generating a refractive index dependent SPR signal). Molecules binding to the sensor surface cause changes in the refractive index close to the surface which are detected as changes in the SPR signal (expressed in resonance units, RU where one RU is equivalent to one picogram per square millimeter on the sensor surface). In general, the refractive index change for a given change of mass concentration at the surface layer, is practically the same for all proteins and peptides, and is similar for glycoproteins, lipids and nucleic acids. Biomolecular binding events cause further changes in the refractive index and the SPR signal. Biacore X precisely controls every critical step to detect the small changes between a baseline signal and the signal generated when a second or third molecule interacts. 2. Monitor Temperature controlled detection environment with a high data acquisition rate replace result in a high signal to noise ratio Detection system allows studies in non-aqueous and aqueous samples, with target molecules in native form 2a. Microfluidic system Flow cells designed to use as little as 5µl of sample Elimination of air/liquid interfaces minimizes protein denaturation Fast buffer/sample exchange rates minimize sample dispersion Continuous injection maintains sample concentration ensuring accurate rate constant determination Two flow cells allow immobilization of 2 different molecules Dual-channel detection and serial flow allow monitoring of 2 different interactions simultaneously In line reference subtraction from the same sample injection ensures perfect controls Sample recovery for complementary analysis Biacore s unique integrated fluidics design

2b. Sensor surfaces A wide selection of sensor surfaces to maximize application flexibility Highest quality sensor surfaces to minimize non-specific binding and protein denaturation Stable surface chemistry ensures low drift and tolerance to very harsh conditions Extensive range of sensor chip surfaces 3. Evaluate Global fit and numerical integration for simultaneous analysis of several data sets and evaluation of kinetic constants Determination of affinity constants for surface and solution interactions Determination of active concentration from binding level or binding rate data Theoretical investigations by simulation from models and kinetic parameters The sensorgram output of Biacore systems

System Specifications Sample handling: Manual sample loading/automated injection Molecular weight detection: >18 Da Detection performance Myoglobin*: 1 pm Flow rate range: 1-1 µl/min, through flow cell, steps of 1 µl Required sample volume: injection volume +2 µl Refractive index range: 1.33-1.4 Analysis temperature: 4-4 C (max 1 C below ambient) Number of flow cells: 2 (used individually or in series) In-line reference subtraction: yes Dimensions (L x W x H): 584 x 462 x 317 mm Electric voltage: 1-12 V; 22-24 V Power consumption: max 58 VA Net Weight: 25 kg/55 lbs * Detection limits achieved with myoglobin 17 Da, measured with an antibody sandwich assay Ordering Information Biacore X is delivered with processing unit, system controller, Biacore X control software, BIAevaluation, BIAsimulation and Windows 2 operating system. Please contact your local Biacore representative for more information. Related Products BIAevaluation Software Kit BIAsimulation Software Kit Related Literature BIAevaluation Product Information Sheet BR-12-16 BR-12-3 BR-9-85 Windows 2 is a trademark of Microsoft Corporation. Biacore is a registered trademark of Biacore AB. Copyright Biacore AB 21 BR-9-72