CHECKLIST C ACCESSIBLE TOILETS CHECKLIST



Similar documents
Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.

Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom

Accessibility Design Advice

Document M. MPacks Compliance Information Specialist Products

FACILITIES IN BUILDINGS OTHER THAN DWELLINGS Audience and Spectator Facilities

ACCESS AUDIT OF WESTPORT HOUSE

Bath Planning Guidelines With Access Standards

THE UNIVERSITY OF EDINBURGH. ECA Evolution House.

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

604 Water Closets and Toilet Compartments

Building for Everyone:

Droveway ARCHITECTURAL SERVICES. Disability Access Audit. Sample Gospel Hall. 22 September For

THE UNIVERSITY OF EDINBURGH. Alexander Graham Bell Building. King s Buildings

BUILDING REGULATIONS PART M 2004 ACCESS TO AND USE OF BUILDINGS. Designers Checklist of Provisions/Areas for Consideration.

ACCESSIBILITY STANDARD

ADA Design Guide Washrooms & Showers

Web version 28/05/08. Building regulations Part M 2004 Disability Discrimination Act 1995

Common ADA Errors and Omissions in New Construction and Alterations

Customer Access 1 Checklist for Banks, Financial and Legal Services

1 STAR HOTELS. Caballero Errante Europa Ibis Budget Madrid Vallecas Ibis Madrid Valentín Beato Sancho

Disabled Access Guide

Hotel accessibility pack

THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings,

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

Saferand easierinstallation

Base Cabinet with Self-storing Folding Doors and Floor

Ministry of the Environment Decree on accessible building

Common ADA Errors and Omissions in New Construction and Alterations

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP

SOUTH GLOUCESTERSHIRE COUNCIL SPECIFICATION REQUIREMENTS FOR WHEELCHAIR UNITS - DRAFT

Planning Guide for Accessible Bathrooms AS including Amdt , ambulant and complimentary items. Sydney Melbourne Brisbane Auckland

PUBLIC RESTROOMS, DESIGN INTENT

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

NEW. Teramo See Page 136

Design guidance and considerations for a domestic accessible toilet/wetroom

Laboratory Construction Guidelines Vicon MX Systems

:2009 HELLENIC CHNICAL SPECIFICATION ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common ICS: 93.

Access Statement Atlantic Tower Liverpool ( )

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

part 9 waste management

IRISH ACCOMMODATION SERVICE AWARDS

1. Geo Vertical 2. Geo Horizontal

THE UNIVERSITY OF EDINBURGH. Pleasance Sports Centre and Gym. The Pleasance.

ACCESS STATEMENT FOR STADIUM TOUR AND MUSEUM, ARSENAL FOOTBALL CLUB

STANDARDS AUSTRALIA. Committee ME-064 Access for People with Disabilities. Australian Standard

:2009 HELLENIC CHNICAL SPECIFICATION. Sanitary ware for disabled persons. ежглеяис тгс йубеямгсеыс (теувос еутеяо) 32199

New College. School Of Divinity.

RADAR

NEW YORK. Downloaded

AlonA Hotel Access Statement

The AKW Guide to Creating Dementia-Friendly Bathrooms

Hotel Accessibility Pack

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN

Number of Sides Required to Have a Handrail

2 THE LAWS OF TABLE TENNIS

HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS PRIMARY CARE CLINICS

accessibility standard

Access Statement for Wood View Guest House

Wheelchair homes design guidelines. Guidelines to achieve the necessary standards for wheelchair users dwellings

UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

1 Door Tall Unit ASSEMBLY GUIDE. Page 1 of 9. WARNING: Contains small parts, keep out of reach of children.

Vitraflex Classic Modular Combination Shower and Changeroom Cubicles (c/w Telescopic Stainless Steel Leg Anchors)

Innovative DOOR STATION Solutions

Building Regulations Technical Guidance Document M. Access for People with Disabilities

PRISLISTE SANITARY WARE FURNITURE WELLNESS FAUCETS ACCESSORIES. Veiledende forbrukerpriser gjeldende fra

Hotel Accessibility Pack

The emergency provisions affect the following Building Code sections:

Trowse Primary School. Policy for Intimate Care

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

NEWSTAR BROCHURE. December 2007

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

COMMONLY USED RESIDENTIAL BUILDING CODES

Please also see 10 golden rules for correct Saniflo installation on

Ceiling Mounted Folding Attic Ladders Installation Instructions

PLUMBING CARE AND REPAIR

Transcription:

CHECKLIST C ACCESSIBLE TOILETS CHECKLIST These guidelines relate to accessible toilets for use by visitors. Different considerations may apply where accessible toilets are to be used by employees. All dimensions are derived from Inclusive Mobility a Guide to Best Practice on Access to Pedestrian and Transport Infrastructure (2002) written by Philip R Oxley (Cranfield Centre for Logistics and Transportation) for the Mobility and Inclusivity Unit of the Department of Transport. These measurements themselves are largely based on BS 8300 Design of buildings and their approaches to meet the needs of disabled people Code of Practice. Feature Requirement Explanatory notes Space for your notes Location Type of toilet Size of cubicle Signage Ideally the toilet should be placed near to the meeting rooms, and certainly on the same floor as the principal meeting rooms. Ideally the toilets should be independent unisex toilets, not integrated with male and female toilets. This allows a disabled person to be accompanied by a person of the opposite sex. In new buildings, the size will be governed by the Part M Approved Document. In existing buildings the availability of space will govern the size of the cubicle. Where the accessible toilet is not placed immediately adjacent to the male and female toilets, a sign is needed to direct visitors to the accessible toilet. BS 8300 recommends a minimum size of 2.2 m x 1.5 m.

Door Minimum opening 925 mm. Fittings within cubicle No door closer should be fitted. The door must be capable of opening outwards. It can also open inwards if the cubicle is large enough, but it must be capable of opening outwards in an emergency. It must be possible for the disabled person to manoeuvre the wheelchair into the cubicle relatively easily, and close the door. There needs to be a horizontal closing rail on the inside of the door at a height of 680 mm. There needs to be a lock that is convenient to operate and can be opened from the outside in case of emergency. The lock needs to be operated by a lever not by a rotating action. The centre of the WC should be 500 mm from the side wall on which the wash basin is fixed. The door should stay open until the disabled person closes it behind him or her. In case a disabled person falls over inside the cubicle. Unless it is a large cubicle, this means that the door must open outwards. This will enable the disabled person to pull the door closed from the hinge side of the door, without having to fetch the lock side of the door. This will make it easier to open and close for a person with restricted dexterity. This ensures that the user can reach the grab rail.

The flushing lever on the WC cistern should be positioned on the opposite side to the wash basin (ie the same side as the wheelchair will be positioned). The fixings for the WC seat should be metal rather than plastic. Where the WC is forward of the cistern, a padded back pad needs to be provided. No back pad is needed if the WC and cistern are close coupled: the cistern will provide the necessary support. There should be no lid on the WC seat. This will enable the user to flush the toilet after transferring back to his or her wheelchair. Plastic fittings are likely to break under the weight of the user. The back pad allows the user to undress and dress while seated on the WC, by arching his or her back against the back pad. This will interfere with the use of the back pad. The seat on the WC should not have a gap-front. The WC should be of a standard design that allows the fitting of a lavatory seat riser by people who need to use one. This allows a user to raise the height of the WC. Where the WC and the cistern are close-coupled, the cistern lid needs to sit within the cistern and be screwed in. The toilet paper, wash basin, soap dispenser and towel/hand drier should be within easy reach of a user sitting on the toilet. The wash basin should have a lever-operated mixer tap on the side closer to the WC. The user will be seated on the WC when using the tap.

Support rails A vertical rail is needed beside the WC, outside the hinged support rail, 600 mm long with the bottom end of the rail at a height of 800 mm. A hinged (drop-down) support rail should be provided on the wheelchair side of the WC, at a height of 680 mm, and 320 mm from the centre line of the WC. A horizontal (grab) rail is needed on the wall beside the WC at a height of 680 mm. Accessories A vertical rail is needed either side of the wash basin, 600 mm long with the bottom end of each rail at a height of 800 mm. All rails should be 35 mm in diameter, with a good grip when wet, and the fixed rails should have 60 mm clearance from the wall. The rails should be fixed very securely to the wall. One mirror should be sited over the wash basin. Where space allows, there should be a second mirror located away from the basin, at least 1000 mm tall with the bottom edge at a height of 500 mm. Two coat hooks should be provided, one at a height of 1050 mm (for the wheelchair user) and the other at conventional height. The rails each need to be able to support the weight of an adult man. The second mirror is for use by wheelchair users.

Emergency alarm Lighting There should be no obstructions such as soil pipes, boxed-in pipework or columns, and no obstacles such as waste bins in the space adjoining the WC where the wheelchair will need to be put. An alarm cord should trigger an audible signal both inside and outside the cubicle, and also (where possible) at a reception area that is constantly staffed. The alarm cord should be in a contrasting colour (conventionally red), positioned to hang between the WC and the basin, passing through the grab rail. Two large pull handles (50 mm in diameter) should be attached to the cord, one at between 800 mm and 1000 mm above floor level and the other at 100 mm above floor level. There needs to be a reset switch for the alarm within the cubicle. This should be within reach of the user seated on the WC as well as in a wheelchair. Where lighting can be individually controlled in a cubicle, the light switch should be within reach of a user in a wheelchair. The lighting level needs to be sufficient. The space where the wheelchair will be placed is often referred to as the transfer space. The signal needs to be audible inside the cubicle so that the disabled user knows that the alarm is sounding (whether accidentally or deliberately). This will enable the user to summon help either from the WC itself or from the floor level. This will enable the user to switch off the alarm if it has been triggered in error.

Décor Floor surface There should be a good level of contrast between the following areas: floor and walls door and walls rails and walls porcelain fittings and surroundings The finishes should be matt. The floor surface should be slip-resistant. This assists people with visual impairments. Shiny surfaces can be confusing for visually impaired people.