Technical Data Sheet OPUS A3 STANDARD Full



Similar documents
Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

Technical Data Sheet OPUS A8 ECO Full

Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB,

MultiViu Flex 7 Data Sheet

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Duct Humidity Transmitter

Hardware Manual RM CANview Ethernet

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Omega ICD Intelligent Colour Display

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Multi-Range Programmable DC Power Supplies 9115 Series

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Series 7500 Torque Sensor

Modular I/O System Analog and Digital Interface Modules

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

TX OPEN RS232/485 module

Data Sheet Quantron A

Plug-in relays Mini ISO relays

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Day / Night IR Color Camera User Manual V2.1.0

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Kvaser Mini PCI Express User s Guide

MILE Encoder for EC 90 flat

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

ACR880 GPRS Portable Smart Card Terminal

Digital input modules

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Multi-Range Programmable DC Power Supplies 9115 Series

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Series 6000 Torque measured metal bellow coupling

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Industrial Bar Code Scanners

Inductive sensor NI10-M18-Y1X-H1141

with Electronic Assistant

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Installation instructions CAN/RS232-USB interface CANfox EC / / 2010

User Manual Color video door phone

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

R60 USB to CAN interface Manual (1.5 EN)

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Installation manual. Generator Paralleling Controller GPC multi-line C

Adjustment functions for both span and shift have been incorporated

COLOR VIDEO DOOR PHONE CDV-71BE/D

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

aseries A13B Mini Bullet Camera User Manual

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Encoder WDGI 58H.

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

How To Power A Schen

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Technical Data. Dimensions

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Manual Ranging MultiMeter

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

HCR3.2/.. Chipcard reader HOTEL SOLUTION

PCS0100en Persy Control Services B.V. Netherlands

ABSOLUTE ROTARY ENCODER ETHERNET/IP

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Actuators and positioning drives

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

DC Electronic Loads 8500 series

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Air damper actuators

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Givare NC-SRS 280 och 880

Ensto Chago Master EVM300 and EVM500 Operational description

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Fakra. Coaxial connectors. DC 6 GHz

Point of view HDMI Smart TV dongle Mini RF Keyboard

Multifunction devices

2013 Wireless Video Intercom INSTALLATION GUIDE

Specifications. Product Description 18.5" Fanless, Intel ATOM D GHz Processor, Multi Function Panel PC

Combi switchbox with integrated 3/2 way pilot valve

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Redundancy Module QUINT-DIODE/40

Transcription:

Technical Data Sheet OPUS A STANDARD Full 28.0.2016 Errors and technical changes excepted

1 Notes and Warnings Attention! This description is not a substitution for the concerned product s documentation. Please do read the documentation including the manuals carefully before dealing with this product. If the safety instructions in the documentation are not followed dangerous situation can occur that can result in damages, injuries and/or death by high voltage or wrong handling. In case you do not have the correct documentation you can order it by contacting dl-opus@topcon.com. Only properly trained personnel with the correct qualification are allowed to handle the device. Attention! Do not open the housing to avoid danger to high voltages. Before touching the electric assemblies make sure that the electricity is switched off completely. If the front pane is broken the device needs to be taken out of service due to risk of injury. If perceivable damages on the device exist that can compromise the functionality, it must be taken out of service due to the danger of malfunctions. These particularly include damages to the LCD display, damages to the keyboard, damages that compromise the protection level and damages to the encoder knobs. Please note: All content is subject to change without notice. Errors and omissions excepted. Mounting and Handling 1. Do not use the cable as a handle to carry the device. 2. Mounting in clean working environment only. Dust and oil can harm the electric contacts and compromise the functionality.. Do not mount the device under the use of violence because it can cause damage.. The device must be mounted by trained personnel only into especially designed and tested systems. 5. The device must not be opened or disassembled. 6. The device is to be cleaned with a moist fuzz free cotton cloth. If necessary a mild cleaning agent can be used. Do not use acid or abrasive cleaning agents. 7. The device is to be stored in a cool and dry environment and to be protected against sun shine. 8. If the environmental temperature is beneath 10 C the reaction time of the display increases. 2 General Information Order Numbers This documentation is valid for OPUS A order numbers as follows: OPUSASN1CANF000 OPUSASN1CDSF000 OPUSASN1ISOF000 Wachendorff Projektor CoDeSys ISO-VT Landscape Portrait Older versions: Landscape OPUSASL1CANF000 OPUSASL1CDSF000 OPUSASL1ISOF000 The neutral versions (N) will substitute the portrait (P) and landscape (L) versions.

Dimensions Housing Plastic housing, colored light grey (RAL 705) with black rubber frame. Mounting Landscape or portrait Standalone In-dash

Display Type: TFT Color Graphic LCD with LED backlight Size:., 95 mm (W) x 5 mm (H) Resolution: 80 x 272 px (WQVGA), 15:9 Colors: 16.7 Mio. Brightness: typ. 00 cd/m² Contrast Ratio: typ. 00:1 Input Devices Touch Left Keypad Right Keypad Analog resistive keys with tactile feedback Blue LED backlight Lifetime 1.000.000 actuations + keys with tactile feedback Blue LED backlight Lifetime 1.000.000 actuations Indicators and Sensors Encoder Light sensor 1 Multicolor-LED Status-LED s Electromechanical encoder with 16 mechanical detents and push function Lifetime: 1 million cycles 5 Electronics Processor platform CPU: Freescale I.MX5, 52 MHz Mass storage: 1 GByte (approx. 900 MB for customer use) RAM: RTC: Buzzer 256 MByte Buffered by gold cap 60 db(a) in 0 cm distance Lifetime min. 1000h Current consumption (without external load), max. Power Mode On Low-power Sleep Off Current at 1,5 V DC 0 ma 160 ma 90 ma < ma Current at 27 V 20 ma 90 ma 55 ma < ma Power supply System supplied through terminal 0 (battery +, see pinout) and 1 (battery -, see pinout). Terminal 15 (ignition) to be used to switch on/off. Operating voltage range: 9 6 V DC Short circuit protection. Over-voltage protection up to 8V for max. 2 minutes. Inverse polarity protection up to -8 V DC.

6 Interfaces CAN Bus 2 x CAN-Interfaces according to ISO 11898, CANspecification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) RS22 1 x RS22-Interface Type: EIA22 (only RxD, TxD, GND) Speed: max. 115 Kbps USB Host 2.0 Main connector: On front: Inputs 1 x Full speed 1 x USB slot High speed configurable analog/digital inputs Input impedance: > k Ohm Resolution: 10 bit (1028 digits, 1 digit = 11,7 mv) Voltage range: 0 12 V Over-voltage protection: Up to 6 V DC Short circuit protection: Up to 6 V DC Frequency: Max. signal frequency 50 Hz Outputs digital outputs Short circuit protection: Up to 6 V I max 00 ma open drain R DS,on < 1 Ohm > 100 kohm R DS,off Video-Interface Inputs: V ss Camera supply: Max. current: Output: Ethernet-Interface 1 x 10/100 Mbit/s Base T 1x analog 1 V 12 V DC 500 ma 1x camera control output (open drain) on each interface for special functionality (mirror, shutter, heating etc.), Ampacity: 00mA 7 Connectors Connectors Main: Tyco-AMP 17288-6 Mating connector (customer) Tyco-AMP -17290-7 Mating crimp contact (customer) Tyco-AMP -17221- Dummy Plug (customer) Tyco AMP -1728- Ethernet: M12 round connector, female, -pole, D-coded acc. to EN 61076-2-101 Recommended mating connector type according to IEC 61076-2-10: MM 00-Gx1-D x) A, C, I, P, R or S-type Video: M12 round connector, female, 5-pole, B-coded, acc. to EN 61076-2-101 Recommended mating connector type according to IEC 61076-2-10: MM 005-Gx1-B x) A, C, I, P, R or S-type

8 Software Operating System Linux 2.6.28 Application Programming Wachendorff Projektor Tool Optional: Codesys-Tools (.5) Optional: ISO-VT Optional: C/C++ 9 Testing and Verification CE-Compliance EU Directive 201/0/EU (EMC) according to EN 12895: Industrial Trucks Electromagnetic compatibility EN 109: Construction machinery Electromagnetic compatibility of machines with internal electrical power supply EN ISO 1982: Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria E1 - Type approval EU Directive ECE R 10. Protection Level (IP Code) IP 6k5 according to ISO 2065: Road Vehicles Degrees of protection (IP-Code) Protection of electrical equipment against foreign objects, water and access Electrical 12 and 2V-Systems according to ISO 16750-2: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Electrical loads ISO 1500: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions Mechanical ISO 16750-: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Mechanical loads, Code L ISO 1500: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions Mechanical Shock: Level 2 Random Vibration: Level 2 Sinusoidal Vibration: Level 2 Climate ISO 16750-: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Climatic Loads Operating Temperature Range: -0 +65 C Storage Temperature Range: -0 +85 C ISO 1500: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions

10 Pinout Main connector pinout Pin. No. 1 2 5 6 7 8 9 10 11 12 1 1 15 16 17 18 19 20 21 22 2 2 25 26 Assignment VCC Ignition Input GND CarGND n. c. n. c. n. c. CAN1H CAN1L CAN2H CAN2L USB_VCC USB_GND USB_D- USB_D+ RS22 RxD RS22 TxD RS22 GND A/DI A/DI1 A/DI2 A/DI SERV_EN DO DO1 DO2 Description supply voltage +; terminal 0 ignition input; terminal 15 supply voltage - ;terminal 1 Car GND Not connected Not connected Not connected CAN 1 high CAN 1 low CAN 2 high CAN 2 low USB +5V supply USB supply GND USB Data - USB Data + RS22 receive data RS22 transmit data RS22 GND analog/digital input analog/digital input 1 analog/digital input 2 analog/digital input service enable digital output digital output 1 digital output 2 View on rear side of the A 1 7 8 1 1 19 20 26

Video connector pinout Ethernet connector pinout 1 2 5 Round Connector, 5 pins, M12 VidSig+ Mirror Camera+ Camera - VidSig GND 1 2 Round Connector, pins, M12, acc. To IEC 61076-2-101 TD+ RD+ TD- RD- Video connector, M12, female, 5 pins, b-coded, view on rear side of the A Ethernet connector, M12, female, pins, d-coded, view on rear side of the A 1 2 1 2 5 Recommended mating connector type according to IEC 61076-2-10: MM 005-Gx1-B x) A, C, I, P, R or S-type Recommended mating connector type according to IEC 61076-2-10: MM 00-Gx1-D x) A, C, I, P, R or S-type 11 Mounting accessories (not included) Standalone mounting adaptor for RAM mounting system (OPUSAZBAH001) Material PC+ABS Dimensions 7x8x2 mm (WxHxD) Operating Temperature -0 +75 C Storage Temperature -0 +85 C Max mounting torque 2.5 ± 0.2 Nm