Roxar Multiphase meter 2600 Class - Turning information into value



Similar documents
1-4 kg/m3. Long in-line calibration cycles of the gamma density systems may improve measurement accuracy, but this is often not practical subsea.

UPM Figure 1 MPFM installed on well pad

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

Experience from implementing a metering solution for subsea and topside multiphase flow metering

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

GOOD PRACTICE GUIDE AN INTRODUCTION TO MULTIPHASE FLOW MEASUREMENT

Rosemount Orifice Plate in Wet Gas

roxar global services

CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation

Energy and Flow Measurement for Hydronic Systems

Service catalog Flow products

Flow Measurement Options for Pipeline and Open Channel Flow

The Unique Accelabar Flow Meter

For Multi-Parameter Meters see mvx

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

COMBIMASS. Technical Data COMBIMASS eco-bio +

V-Cone, An Alternative to Orifice Meter in Wet Gas Applications

Micro Motion ELITE CMFS Series Meter

Micro Motion Net Oil Computer Software and NOC System

APN1001: Circuit Models for Plastic Packaged Microwave Diodes

Havbunnsproduksjon. NTNU, 15 april 2013 Eldar Lundanes System Responsible for Controls and Data Management, Eastern Region.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Gas Custody Transfer Calibration

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

RGC-IR Remote Gas Calibrator for IR400

Baumann Little Scotty Bronze Control Valve

Flow Assurance & Operability

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

O C M III. Open Channel Flow Monitor

Micro Motion Model D and DL Coriolis Flow and Density Meters

MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING

Roxar Watercut meter. Roxar Watercut meter. Product Data Sheet

Advances in Thermal Dispersion Mass Flow Meter Accuracy

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

PIEZOMETER AIRFLOW MEASURING RING

Gas Discharge Tubes GTCX36-XXXM-R05 Series

1 WATERFLUX - Comparisonon COO Rectangular Magmeter in water applications

Managing The Integrity Threat Of Subsea Pipework Fatigue Failure. John Hill Senior Consultant Xodus Group

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

FLUID COMPOSITION ANALYSIS BY MULTIPLE GAMMA-RAY BEAM AND MODALITY MEASUREMENTS

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

CCI 100 DPC DRAG Wellhead Production Choke Valve

Take total control of your HVAC system with cost-saving flow and thermal energy meters

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

To enable transport of wellstream over long distances. Compressor located by the wellheads.

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.

How To Use A Corona Mdi 110

Replacing Displacers with Guided Wave Radar

ClampOn DSP Pig Detector

SKY LF: 0.5 to 6.0 GHz SPDT Switch, 50 Ω Terminated

Rosemount 333 HART Tri-Loop

SKY LF: GHz Two-Way, 0 Degrees Power Divider

BaseCal 3. BaseCal, the web-based performance calculation tool for Diaphragm Seals

Aker Drilling Riser Brazil

PORTABLE FLOW METER KITS TDS-100H

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Natural Gas Well Automation using Kingfisher RTU Products

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

T0118 T2118 T3118. Instruction Manual

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Product Description Sheet RB15 200D Gantry Robot Item No

Mechanical Seal Piping Plans

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Electromagnetic Flow Meter

IFC 070 Technical Datasheet

Instruction Manual. T3111 T3111L T3111P T3111Ex

SINGLE-SUPPLY OPERATION OF OPERATIONAL AMPLIFIERS

RADIATION MONITORING SYSTEMS

Effects of Atmospheric Pressure on Gas Measurement

Current-Transformer Phase-Shift Compensation and Calibration

Custody Transfer Measurement. with the V-Cone Flowmeter

3D Interactive Information Visualization: Guidelines from experience and analysis of applications

OPTIMASS 1400 Technical Datasheet

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Field Trials and Pragmatic Development of SONAR Flow Meter Technology. Bill Pearson, BP AGT and Nigel Webster, Expro

Guidelines for FEASIBILITY STUDY

Signal Conditioning Amplifier System

High Voltage Power Supplies for Analytical Instrumentation

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

ABB PSPS Erich Steinmann; Generator control-2013

Overview of the state of the art heat measurement technologies for larger solar thermal systems

5.2. Vaporizers - Types and Usage

ShorePhone IP 8000 User Guide

Online Infrared Flue Gas Analyzer Gasboard 3000

REMOTE MONITORING SYSTEM MATURE FIELDS UNCONVENTIONALS MONITORING SYSTEM. Solving challenges.

A Practical Overview of Level Measurement Technologies

World s Best Oil in Water Analyzers

Saft Groupe SA Full year results 2014

SWIMMER. An innovative Subsea Intervention System for Deep Offshore Fields. Jean-Jacques QUESNEL CYBERNETIX S.A. Oil&Gas Division

Transcription:

Roxar Multiphase meter 2600 Class - Turning information into value This presentation is provided for information purposes only. It should not be used or considered as an offer to sell or a solicitation of an offer to buy any securities. Any opinions expressed are subject to change without prior notice. Although all reasonable care has been taken to ensure that the information herein is not misleading, Roxar ASA makes no representation or warranty expressed or implied as to its accuracy or completeness. Neither Roxar ASA, its employees, nor any other person connected with it, accepts any liability whatsoever for any direct or consequential loss of any kind arising out of the use or reliance on the information in this presentation. This presentation is prepared for general circulation and general information.

Content Multiphase metering applications Roxar celebrating 25 years of Multiphase innovation The 3rd generation: Roxar Multiphase meter - 2600 class The Zector technology platform Test results & Specifications

Roxar s Mission statement: Our mission is simply: TO ENABLE OUR CUSTOMERS TO MAXIMIZE RESERVOIR PERFORMANCE Roxar is the industrial inventor and pioneer of multiphase metering and sand monitoring, and a leading global supplier of real-time measurements solutions for production optimization, enhanced oil recovery and flow assurance. Roxar s instrument design philosophy is based upon the following principles: - Keep it simple - Build in redundancy - Maximize use of direct measurements

What is a multiphase meter - A non-intrusive multiphase flow measurements device that provides real-time and continuous three-phase measurements Measures fraction and velocity of oil fraction and velocity of water fraction and velocity of gas Outputs Oil rate Water rate Gas rate

The only complete multiphase metering product suite Topside meters Watercut WCM Multiphase MPFM 2600 non-gamma Multiphase MPFM 2600 gamma Highgas HGS Wetgas WGM 0 5% 0 95% 0 100% 30 99% 95-100% Gas Void Fraction Range Subsea meters 0-98% 90-100% Multiphase MPFM SCR Wetgas SWGM

Roxar Multiphase and Wetgas meters Subsea meters Gamma Topside meters Non-gamma Gamma Wetgas

Roxar Multiphase meter applications Traditional layout using separators Complex piping and valve arrangement Limited / periodic testing only

Roxar Multiphase meter applications Using inline Multiphase meters Real-time and continuous monitoring Excluding test separator on new/upgrade installations Early detection of water/gas breakthrough Improved well control Reduction in Opex and Capex! Ultimately - Optimize the lifetime of the field

Roxar Multiphase meter applications Using Multiphase meters Well testing (mobile) Production monitoring Production allocation

Roxar The founder of multiphase metering

The industrial inventor of multiphase metering Roxar started the development of multiphase metering technology in 1984 and can celebrate 25 years of innovation!

History Technology development since 1984 Fluenta / MFI Roxar (2001) 1. Generation meters MFI topside (1994 2001) MFI subsea (1995 2001) 2. Generation meters MPFM 1900VI (1995 ) MPFM SRC subsea (2001 ) Roxar WGM (2002 ) MPFM 1900 Vi Non-Gamma (2003 ) 3. Generation meters MPFM 2600 based on Zector Technology (2009 )

History The first generation of multiphase meters: assumed homogenous flow conditions incorporated models based on a single flow velocity The second generation of multiphase meters: dual cross correlation (Liquid and Gas velocity meas.) sophisticated signal processing The dual velocity model is a well suited model, but still a simplification of the very complex flow patterns Industri standard: More than 1000 Roxar Meters delivered

Welcome to the new standard in multiphase metering technology

Welcome to the new standard in multiphase metering technology A new class of Multiphase meters - Improving measurement quality - Widening the operating envelope - Meeting environmental concerns

Innovative design for the future

Innovative design for the future With 25 years of innovation and as the founder of multiphase metering, Roxar is taking technology to a new level with the launch of its 3rd generation meter: MPFM 2600 based on Zector technology

Roxar 2600 class key elements

Roxar 2600 class key elements Simple, light-weight design, 80% weight reduction and half the length compared to the previous generation Field replaceable insert venturi Compact, integrated measurement solution for pressure, differential pressure and temperature Non-radioactive version covering most operating conditions - gamma version for special applications and high GVF Innovative Zector technology: Advanced signal processing, new field electronics and electrode geometry provides accurate characterization of flow

Roxar 2600 class key elements Simple, light-weight design, 80% weight reduction and half the length compared to the previous generation The image shows the relative difference in size for a typical 3 meter Weight: 550 vs.110 kg Length: 1300 vs. 650 mm

Roxar 2600 class key elements Field replaceable insert venturi Four pressure tapping s and ring chamber improves accuracy and stability (same design as for subsea meters) A field replaceable insert venturi allows for extended service life and operating range, and removes uncertainties when sizing meters based on predicted production forecasts

Roxar 2600 class key elements Compact, integrated measurement solution for pressure, differential pressure and temperature Multivariable transmitter Enables highly sensitive, accurate, DP, P and T measurements Combines the best features from remote seal solutions and open impulse tubing Limits the potential for clogging (no impulse lines)

Roxar 2600 class key elements Non-radioactive version covering most operating conditions - gamma version for special applications and high GVF Base version is non-gamma suited for installations < 95% GVF Benefit: applications where the use of nucleonic sources is unacceptable due to legislation or company policy For applications with very high GVF (>95%), the gamma version is recommended The gamma system can easily be retrofitted if and when flow conditions so dictate

Introducing Roxar Zector technology Key components of Roxar s Zector technology: -DP26 electrode geometry -New impedance electronics -Voxel based signal processing (4D pixels) Voxel based signal processing and DP26 electrode geometry provides: - multiple flow velocities - near wall measurements The new technology operates seamlessly in both oil- and watercontinuous flow which results in rapid detection of regime changes

Introducing Roxar Zector technology Electrode geometry Measures a large number of different combinations Enabling a much more detailed fraction measurement Close-to-wall electrodes gives improved measurement accuracy, extended operating range, multiple velocity measurements and scale/wax detection/correction

Introducing Roxar Zector technology Impedance electronics Replaces the capacitance and inductive electronics, and uses the same set of electrodes Measures both components simultaneously - operates seamlessly in both oil- and water-continuous flow Analog Devices Blackfin Processor - specially developed for real time image processing and streaming media application Front end: 1.000.000 samples / second Flow computer: computes 12.000 verified data points / second Modbus registry: updated 50 times / second

Introducing Roxar Zector technology Voxel based signal processing A voxel is a volume element, representing a value in a three dimensional space This is analogous to a pixel, which represents 2D image data Voxels are frequently used in the visualization and analysis of medical and scientific data Voxel based signal processing allows for measurements in individual sectors in addition to the traditional full cross-sectional area measurement

2nd generation Real system Dual velocity system Dp22 electrode system Multiphase / multi-velocity 2 volumes - Large bubble volume (r, l) - Dispersed phase 2 velocities - Large bubble velocity - Dispersed phase velocity

Roxar MPFM 2600: 3rd generation Real system 4D voxel system Dp26 electrode system Multiphase / multi-velocity Multiple time dependent voxels; -Asymmetric Large bubble volume, -Variable dispersed phase volumes -Near wall measurement volumes Multi velocities -Large bubble velocity -Dispersed phase velocity - Velocity per sector

Roxar 2600 class Test results

Specifications Qualification testing The Roxar Multiphase meter 2600 has been extensively tested, both statically and dynamically, including: - Pressure and temperature cycling - Calibration and sensitivity testing - Flow testing The loop testing has demonstrated superior performance for measurement of all three phases As a result, the operating envelope has been widened, and uncertainty is reduced

SUMMARY - CMR FLOW TEST RESULTS DECEMBER 2008 - MPFM2600 VS. MPFM1900 Meter Regime Test phase Points within Percentage of points Improvement No. of test points MPFM2600 MPFM1900 OC WC Gas Liquid WLR uncertainty limits inside limits MPFM2600 vs. MPFM1900 x 111 100 % x x x 111 x 109 98 % 2 % x 108 97 % x x x 111 x 105 95 % 3 % x 111 100 % x x x 111 x 106 95 % 5 % x 330 99 % x x x x x 333 x 320 96 % 3 % Conclusion: Uncertainties improved significantly for all three phases Less variance in measurements showing better repeatability

Specifications Typical communication set-up Safe area Hazardous area Roxar Fieldwatch Flow Computer Distributed Control System

Specifications Roxar Fieldwatch software Provides interpretation, analysis, monitoring and diagnostics tools to assist daily operations, production optimization and reservoir management

Summary Grayloc hub flanges Insert venturi design - field replaceable Rosemont 3095 Multivariable Transmitter (DP, P & T) Integrated temperature measurement New field electronics Combined sunshade and mechanical protection Density measurements Non-gamma software or compact gamma system Electrode configuration DP 26 Multi electrode, dual plane Roxar Fieldwatch software Add-on modules Acoustic Sand monitor Roxar Fieldmanager, Well test package, PVTx, +++

Today Tomorrow Welcome to what s next, welcome to the future Roxar Multiphase meter 2600 Built on Zector Technology This presentation is provided for information purposes only. It should not be used or considered as an offer to sell or a solicitation of an offer to buy any securities. Any opinions expressed are subject to change without prior notice. Although all reasonable care has been taken to ensure that the information herein is not misleading, Roxar ASA makes no representation or warranty expressed or implied as to its accuracy or completeness. Neither Roxar ASA, its employees, nor any other person connected with it, accepts any liability whatsoever for any direct or consequential loss of any kind arising out of the use or reliance on the information in this presentation. This presentation is prepared for general circulation and general information.