Dow Corning AllGuard Silicone Elastomeric Coating. Application and Maintenance Guide



Similar documents
The Ultimate in Weathersealing Versatility. Dow Corning 123 Silicone Seal

How To Use Dow Corning Brand Sealants

Stucco Repair and Maintenance No. 1.01

Crystal Clear Sealant

Note: Minor color change may occur in exposed service, but corrosion protection will not be compromised

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

T R A N S F E R A B L E F U L LY

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

SECTION 12. Surface Retarders. Sec 12 TECHNICAL DATA SHEET. Surface Retarders. Face-Off Top Cast American Owned American Made

Sto Specification No. RC100 Guideline Specifications for Cleaning Wall Surfaces

SC2000 CEMENT BONDING PROCEDURES

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

A. Work on this project shall consist of, but is not limited to, the following:

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

POZZI WINDOW COMPANY LIMITED WARRANTY WINDOWS, DOORS AND COMPONENT PARTS

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

Additional Information. Paint Application

SILASTIC 9161 RTV Silicone Elastomer

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

RTV162. Electronic Grade Silicone Adhesive Sealant

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Acrylic Coatings: The Perfect Stucco Finish

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS Description. Key Features and Benefits. Typical Physical Properties

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Document Library TS Data Sheet M Windo-Weld Super Fast Urethane. Data Sheet. Public

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

BENTLEY ELEMENTS COLLECTION LVT

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Technical Data Sheet February 2014

Mortar Glass Block Installation System

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Minor Cracks in Horizontal Surfaces

3M Scotchkote Urethane Coating 165HB

Double Coated Urethane Foam Tapes

Metal Rescue Rust Remover Technical Data

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

3 Scotch-Seal TM. Polyurethane Sealant 540 Polyurethane Adhesive Sealant 560. Technical Data July, 2008

Product Information/Specifications

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

3M Thermally Conductive Adhesive Transfer Tapes

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, (68 pages)

White rust on galvanized and galvanized pre-painted steel. Technical Information

SECTION POLISHED CONCRETE FINISHING

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

Business area System/product family System/product Exterior restore group. Sto restore Advanced Restoration for Building Façades

RAPTOR TRUCK BED LINER - BLACK

SPECIAL NOTE FOR ASPHALT WATERPROOFING MIX FOR BRIDGE-DECK OVERLAYS AND ADJACENT APPROACHES

Manufactured Stone and Thin Brick Installation Systems

3 Fuel Resistant Coatings

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

BLACK JACK ALL WEATHER ROOF COATING

3 Masonry and Manufactured Stone (Interior and Exterior)

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

Contractor s Handbook

REFLECTIT. Reflectit Application Instructions Spray and Roller DS % Acrylic Coating Providing a Pearlescent Appearance

Maintenance & repair Solutions

How to repair your existing low slope flat roof.

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

Spandrel Glass Types and Recommendations

Document Library TS Data Sheet

SEAMS SEAMING USING SEAM TAPE

PELLA 350 SERIES VINYL WINDOW & PATIO DOOR LIMITED WARRANTY

Dryvit Finish System For Exterior Soffits

Acrylic Walls Installation Instructions

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

Division 9. SignaFlor Pad and Pour Flooring System

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

RECOATING AND RENEWING SPF ROOFING SYSTEMS

Columbia flooring will resist fading from exposure to sunlight or artificial light.

Installation Instructions

CA-48 TECHNICAL SPECIFICATION

MODULAR EPDM ROOFING SYSTEMS

SCHWARTZ WATER-BASE WOOD FLOOR SEALER AND WATER-BASE PREMIIUM WOOD FLOOR FINISH

Section Polished Concrete Finishing. Vexcon

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

3M Thermal Bonding Film AF42

Resurfacing Concrete. Page 1 of 5

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405

Active and Passive Sash Replacement

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Eclipse. Technical Data Sheet. Polyurethane topcoat. Product Group

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Transcription:

Dow Corning AllGuard Silicone Elastomeric Coating Application and Maintenance Guide

Contents This document is intended to provide installation and field testing instructions for Dow Corning AllGuard Silicone Elastomeric Coating. Additional information regarding cleaning and maintenance is included to provide maximum, long-term waterproof performance for your building. Product Description... Substrate Compatibility... Compatibility with Dow Corning brand Products... Colors... Shelf Life... Application... 2 Design Considerations... 2 Figure : Drip Edge Design... 2 Temperature and Humidity... 2 Surface Preparation... 2 Sealing Cracks... 2 Workmanship... 2 Priming... 2 Table I: Surface Preparation... 3 Table II: Estimated Application Rate... 3 Coating... 3 Drying Time... 3 Disposal... 3 Adhesion Test Procedure... 4 Figure 2: Test Procedure Diagram... 4 Cleaning and Maintenance... 4 Limited Warranty... 5

Product Description Dow Corning AllGuard Silicone Elastomeric Coating is a one-component water-based silicone elastomer designed to waterproof above-grade exterior masonry substrates. Featuring a smooth, matte finish, this coating is available in a broad range of standard and custom colors that are made to order at your distributor s location. Ideal for both new construction and renovation projects, Dow Corning AllGuard Silicone Elastomeric Coating withstands wind-driven rain without water penetration. Substrate Compatibility is designed to waterproof above-grade exterior masonry substrates, such as concrete block, fluted block, brick, stucco, synthetic stucco, poured concrete, precast concrete, Exterior Insulation Finish Systems (EIFS), and previously coated masonry substrates. generally has primerless adhesion to these substrates. Field adhesion testing is required at the site to ensure primerless results. Compatibility with Dow Corning Products is compatible with the Dow Corning products listed here. Dow Corning AllGuard Silicone Elastomeric Coating can be applied over the sealants after they have been allowed to achieve tack-free cure (see sealant data sheets for specific cure times). It is the only coating that can be used for application over Dow Corning 23 Silicone Seal. Products commonly used with Dow Corning AllGuard Silicone Elastomeric Coating include: Dow Corning 23 Silicone Seal Dow Corning 756 SMS Building Sealant Dow Corning 790 Silicone Building Sealant Dow Corning 79 Silicone Weatherproofing Sealant Dow Corning 795 Silicone Building Sealant When Dow Corning AllGuard Silicone Elastomeric Coating is used in conjunction with Dow Corning 23 Silicone Seal and these recommended sealants, complete building protection can be achieved. Colors is available in over 55 standard colors, and a full range of custom colors is available from your Dow Corning construction products distributor. Shelf Life has a shelf life of 9 months from date of manufacture.

Application Design Considerations As with any high-performance material, care taken in initial design and application will result in longer coating life. In many building designs, there may be areas such as ledges and window sills that allow airborne dirt and soot to accumulate. If the design permits or promotes channeling of water runoff from these areas, dirt streaking is likely to result. Wall texture and environmental conditions are also important factors in the quantity and type of dirt accumulated. Industrial areas and nearby highways increase the probability of soot and hydrocarbon in the air, resulting in a greater chance of dirt pickup and streaking. If the building s location, design, wall surface, or existing dirt streaking indicates channeling of water down the side of the wall, drip edges are recommended on the ledges, window sills, and scuppers to reduce dirt streaking on Dow Corning AllGuard Silicone Elastomeric Coating. In field tests, the use of a drip edge greatly reduces or eliminates dirt streaking. The use of the drip edge moves the runoff water away from the wall, creating a non-patterned runoff. A drip edge can be fabricated from the same material as the window sills or from other formable composites. The design of the drip edge should allow for a minimum " (25-mm) width for attachment to the ledge, with a bent edge of 5 to 45 or minimum / 2 " (3-mm) radius, with the edge at least / 2 " (3-mm) away from the wall (see Figure ). The drip edge can be mechanically adhered to the substrate or attached with Dow Corning 79 Silicone Weatherproofing Sealant or Dow Corning 795 Silicone Building Sealant. A field adhesion test on the sealant to drip edge and sill must be performed to verify good adhesion. Temperature and Humidity can be applied from 5 to 38 C (40 to 00 F). Do not apply if temperatures are forecasted to be below 5 C (40 F) within 24 hours after application. Do not apply the coating when the relative humidity is greater than 90 percent or when there is a threat of rain within 24 hours. Surface Preparation For recommendations to ensure proper cleaning and preparation of the substrate prior to coating, please refer to Table I. Sealing Cracks Static cracks less than / 6 " (.6 mm) can be bridged with Dow Corning AllGuard Silicone Elastomeric Coating. Static cracks greater than / 6 " (.6 mm) must be repaired by methods suitable for the substrate before being coated with Dow Corning AllGuard Silicone Elastomeric Coating. Moving cracks should be stabilized or properly repaired for the expected movement prior to installation of Dow Corning AllGuard Silicone Elastomeric Coating to prevent tearing of the coating due to excessive movement. Workmanship Protect adjacent surfaces and surroundings that are not to be coated. Apply a minimum of 2 coats to achieve a minimum thickness of 0 mils (0.25 mm) dry. Follow design considerations. Priming (if needed ) One coat of primer is required.. Apply at a rate of 300 ft 2 /gallon (7.4 m 2 /L) using a / 2 to 3 / 4 " (3- to 9-mm) synthetic nap roller, nylon bristle brush, or airless sprayer. 2. Apply primer to the point of rundown. 3. Dry 30 minutes to 2 hours. Actual drying time will depend on temperature, humidity, and wind conditions. Allow an additional 30 minutes to dry after dry to the touch. 4. Apply coating over primer at least 30 minutes after primer is dry to the touch, but within 24 hours. If the surface cannot be coated during this time, care should be taken to ensure the primed surface is free of dirt and debris before applying coating. 2 To determine if a primer is required, perform field adhesion tests as outlined on page 4 of this guide.

Table I: Surface Preparation Surface Conditions Detection Method Removal Method Efflorescence 2 Wipe with dark cloth Wire brush; then clean with high-pressure water. On stubborn deposits, mix part muratic acid (or similar) to 2 parts water; then clean with high-pressure water. Dirt/Dust Wipe with dark cloth High-pressure water cleaning. Laitance Scrape with putty knife looking for powdery material Scrape with steel scraping tool followed by highpressure water cleaning. Mildew Visual Scrub with 5 percent bleach solution followed by highpressure water cleaning. Grease/Oil Sprinkle water on surface Trisodium phosphate (TSP) solution in hot water and high-pressure water cleaning. Form release, curing, or surface-hardening compounds Visual; sprinkle water on the surface 3 Must be removed by mechanical abrasion or abrasive water cleaning. These are general recommendations; please refer to substrate manufacturer for specific remediation recommendations. 2 Efflorescence may be caused by migration of water through a cementitious substrate reacting with components of the mix. Removing efflorescence may not prevent further formation of efflorescence at a later time without mitigating water migration within the substrate. 3 If water beads on the surface, the surface is contaminated. Apply a test treatment of detergent or caustic soda with a bristle brush to remove contamination. Retest. If water still beads, a penetrating water repellent may exist and will interfere with adhesion. Contact your Dow Corning Technical Service Representative for further recommendations. Table II: Estimated Application Rate (0-mil [0.25-mm] minimum dry film thickness) Estimated Rate Texture/Substrate ft 2 /gal m 2 /L Smooth (brick, precast concrete) 70-80.7-2.0 Medium (sand, #3 vermiculite, stucco) 50-70.2-.7 Coarse (aggregate, split face block, EIFS) 30-50 0.8-.2 Application rates vary tremendously with porosity and degree of texture on the substrate. These values are estimated and should be confirmed at the job site prior to bidding the project. Coating A minimum of two thick (0- to 2-mil) coats of Dow Corning AllGuard Silicone Elastomeric Coating are necessary to achieve the required 0-mil (0.25-mm) minimum dry film thickness to attain protection against through-water penetration and to qualify for a project-specific warranty. Apply the coating in a minimum 0- to 2-mil (0.25- mm) wet thickness (see Table II for estimated application rates; a job-specific mockup is recommended to determine actual usage). Typically, two 0- to 2-mil (0.25-mm) wet coats will result in the required 0-mil (0.25-mm) dry coating thickness; however, an additional coat may be required due to surface texture or porosity. Apply using a 3 / 4 to / 2 " (9- to 38-mm) nap, polyester, or 50/50 polyester/wool blend roller cover, nylon bristle brush, or airless sprayer. When applying the coating with a roller, apply it in a fan pattern to 3 achieve uniform thickness. Always finish roller applications in the same direction to reduce visual surface texture differences. Allow the coating to dry (typically 2 to 4 hours) before applying the next coat. Note: Do not thin or cut back Dow Corning AllGuard Silicone Elastomeric Coating. Drying Time After the final coat has been applied, the average drying time is 4 to 8 hours, depending upon temperature, humidity, and wind conditions. Dow Corning AllGuard Silicone Elastomeric Coating will attain full adhesion and physical properties in 7 to 4 days. Disposal See the Material Safety Data Sheet (MSDS) for disposal information.

Adhesion Test Procedure Field adhesion testing is required to obtain the project-specific warranty from Dow Corning. Tests must be made on all sides and different substrates of the building being coated. The locations and results are required on the warranty application.. Prepare surfaces as described in Table I. 2. Use of a primer is optional, but testing is required to ensure sufficient adhesion in primerless applications. If primer is used, apply per the application method and allow to dry. 3. Apply the first coat of Dow Corning AllGuard Silicone Elastomeric Coating at a rate of 0- to 2-mil (0.25- to 0.3-mm) wet film thickness. Imbed a cheesecloth strip (" x 2" [25 x 305 mm]) in the wet coating with a paint brush. 4. Apply the second coat over the cheesecloth at the same 0- to 2-mil (0.25- to 0.3-mm) wet film thickness and allow to fully cure for 7 to 4 days. This is an adhesion test only; additional coats may be required to achieve thickness requirements. 5. Test adhesion of the coating by pulling the uncoated part of the cheesecloth at a 80 angle at a slow, steady rate. 6. Inspect and note the percent cohesive failure (percent of coating material left on the wall surface). At least 80 percent of the coating should Figure 2: Test Procedure Diagram remain on the substrate. If the 80 percent retention is not achieved, reclean and test another suitable section. If necessary, contact Dow Corning Technical Service for further instruction. (Refer to Dow Corning s web site www.dowcorning.com for the location of the nearest Dow Corning Technical Service facility.) 7. If adhesion cannot be achieved, the test should be repeated using Dow Corning AllGuard Primer. Cleaning and Maintenance. Abrasive cleaners and cleaning equipment should never be used. 2. Routine cleaning is suggested, and dictated by the surrounding environment. Visible debris, such as airborne dirt or soot, should not be allowed to collect on the coating for a long period of time. This will increase cleaning effort and may be difficult to completely remove. 3. Recommended cleaning method involves the use of pressurized water and a basic cleaning agent such as trisodium phosphate (TSP) or Simple Green TM. Water pressure should not exceed,500 psi (0.3 MPa) to clean the surface without removing the coating material from the wall surface. A small test patch should be done first to determine how long the cleaning agent should be left on the surface before rinsing. 4. Stubborn marks may require the use of a soft bristle brush with the cleaning solution. Avoid stiff brushes that may abrade the coating. 5. Any touch-ups or repairs to the coating can be accomplished by applying Dow Corning AllGuard Silicone Elastomeric Coating to the clean, dry area according to the recommendations in this application guide. Simple Green is a trademark of Sunshine Makers, Inc. 4

Limited Warranty Unless Dow Corning issues a project-specific written warranty, Dow Corning warrants only that the goods meet Dow Corning s sales specifications at the time of shipment. DOW CORNING EXPRESSLY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The buyer s exclusive remedy and Dow Corning s sole responsibility for any claim arising out of the purchase or use of these goods is expressly limited to either replacement of the nonconforming goods or refund of the purchase price within 90 days of the date of purchase. Dow Corning offers a project-specific 0-Year Limited Performance Warranty when the is applied in accordance with Dow Corning s published application guidelines. Contact your Dow Corning Sales Representative for details or to apply for a project-specific warranty. Under this Limited Warranty, for a period of ten years from the date of purchase, Dow Corning will be responsible for the cost of replacement coating for any areas in which the Dow Corning AllGuard Silicone Elastomeric Coating fails to protect the above-grade substrate from through-water penetration and for the cost of labor to apply such replacement coating, up to a maximum of five times the cost of the replacement coating. Dow Corning s warranty is subject to certain restrictions and does not cover faults attributable to workmanship or the appearance of the coating. NOTE: No warranty is available when Dow Corning AllGuard Silicone Elastomeric Coating is used on a single-family residential dwelling. 5

How to Contact Us Dow Corning has sales offices and manufacturing sites as well as science and technology laboratories around the globe. Telephone numbers of locations near you are available on the internet at www.dowcorning.com, or by calling one of our primary locations listed here. Your Global Connection Asia Dow Corning Asia Ltd. Japan Tel +8 3 3287 5 Dow Corning Asia Singapore Tel: +65 253 66 Australia & New Zealand Dow Corning Australia Pty. Ltd. Tel: +6 300 360 732 Europe Dow Corning Europe Tel: +32 64 88 80 00 North America Dow Corning Corporation World Headquarters Tel: + 989 496-6000 South America Dow Corning do Brasil Tel: +55 3759 4300 Handling Precautions PRODUCT SAFETY INFORMATION REQUIRED FOR SAFE USE IS NOT INCLUDED IN THIS DOCUMENT. BEFORE HANDLING, READ PRODUCT AND MATERIAL SAFETY DATA SHEETS AND CONTAINER LABELS FOR SAFE USE, PHYSICAL AND HEALTH HAZARD INFORMATION. THE MATERIAL SAFETY DATA SHEET IS AVAILABLE FROM YOUR DOW CORNING REPRESENTATIVE, OR DISTRIBUTOR, OR BY CALLING YOUR GLOBAL DOW CORNING CONNECTION. Limited Warranty Information Please Read Carefully The information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control, this information should not be used in substitution for customer s tests to ensure that Dow Corning s products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Dow Corning s sole warranty is that the product will meet the Dow Corning sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted. DOW CORNING SPECIFICALLY DISCLAIMS ANY OTHER EXPRESS OR IMPLIED WAR- RANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. DOW CORNING DISCLAIMS LIABILITY FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Dow Corning is a registered trademark of Dow Corning Corporation. 2000-203 Dow Corning Corporation. All rights reserved. Printed in USA AGP Form No. 62-67D-0