Since 1991, when Parodi et al1 described a minimally



Similar documents
Endovascular Repair of an Axillary Artery Aneurysm: A Novel Approach

Imaging of Thoracic Endovascular Stent-Grafts

Talent Thoracic Stent Graft with THE Xcelerant Delivery System. Expanding the Indications for TEVAR

A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair

Patient Information Booklet. Endovascular Stent Grafts: A Treatment for Abdominal Aortic Aneurysms

Overview. Total Joint Replacement in the U.S. KP National Total Joint Registry EMR Tools and Outcome Assessment: A Model for Vascular Surgery?

Instructions For Use Aorfix AAA Flexible Stent Graft System

Ultrasound in Vascular Surgery. Torbjørn Dahl

Local Coverage Article: Endovascular Repair of Aortic Aneurysms (A53124)

REPORTING STENT PLACEMENT FOR NONOCCLUSIVE VASCULAR DISEASE IN LOWER EXTREMITIES

Initial experience with a new fenestrated stent graft

Majestic Trial 12 Month Results

2009/JUL/20 at 9:18 a.m. Doc number: M710950B001 [Uni+] VALIANT THORACIC STENT GRAFT WITH THE CAPTIVIA DELIVERY SYSTEM Instructions for Use

Physician rates effective January 1, 2016 through December 31, 2016.

Thoracoabdominal aortic aneurysm

Diagnostic and Screening Ultrasound Examinations of the Abdominal Aorta in Adults

REFLECTIONS: FORTY YEARS OF VASCULAR CARE

Purpose Members of the Department of Cardiology will provide cardiology services to patients of McLaren Greater Lansing.

ESC Guidelines on the diagnosis and treatment of peripheral artery diseases Lower extremity artery disease. Erich Minar Medical University Vienna

RADIOLOGY 2014 CPT Codes

Antiplatelet and anticoagulation treatment of patients undergoing carotid and peripheral artery angioplasty

Adult Cardiology. Diagnosis of Arterial Disease of the Lower Extremities With Duplex Scanning: A Validation Study

Note to Teachers about The Virtual Stroke Lab Student Handout

Abdominal - Aortic Dissection and Aneurysms

INSTEAD at 5-year follow-up shifts the expectations for endovascular treatment

Patients suffering from critical limb ischemia (CLI)

Endoluminal stent-graft placement in patients with acute aortic dissection type B q

RELAY Plus Thoracic Stent-Graft System with Transport Delivery System

Abdominal Aortic Aneurysm (AAA) General Information. Patient information Leaflet

Joint Working Group to produce guidance on delivering an Endovascular Aneurysm Repair (EVAR) Service.

Renovascular Disease. Renal Artery and Arteriosclerosis

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

Overview of Newer Stent Devices for Aneurysm Treatment

WallFlex Biliary RX Stent. Fully, Partially and Uncovered Self-Expanding Metal Stents

How To Determine Pad

From Experimental to the Standard of Care:

Col league. SMMC Vascular Center Opens A PUBLICATION FOR SOUTHERN MAINE PHYSICIANS

Upper Extremity Vein Mapping for Placement of a Dialysis Access

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

ST. DAVID S MEDICAL CENTER CARDIOLOGY - Special, Invasive, Diagnostic, or High-Risk Procedure Requirements

UW MEDICINE PATIENT EDUCATION. Aortic Stenosis. What is heart valve disease? What is aortic stenosis?

What You Should Know About Cerebral Aneurysms

Vascular Laboratory Fundamentals. Robert Mitchell MD, RPVI Duke University Medical Center 5/2/08

Renal artery stenting: are there any indications left?

AORTOENTERIC FISTULA. Mark H. Tseng MD Brooklyn VA Hospital February 11, 2005

Reporting Transcatheter Aortic Valve Replacement (TAVR) Procedures in 2013

Guidance notes for commissioners implementing the policy on Complex endovascular stent grafts in the management of abdominal aortic aneurysm

Vascular Quality Initiative - Carotid Artery Stent. Last Name First Name Middle Initial

EFSUMB EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY Building a European Ultrasound Community

The treatment of peripheral vascular disease has

Aneurysm Embolization System for the Treatment of Cerebral Aneurysms. Information for Patients and Families

Percutaneous Transluminal Angioplasty (PTA) and Stenting For PVS Patients

Measure #257 (NQF 1519): Statin Therapy at Discharge after Lower Extremity Bypass (LEB) National Quality Strategy Domain: Effective Clinical Care

Cardiac Catheterization

LifeStent XL Biliary Stent System

Complications of Femoral Catheterization. Daniel Kaufman, MD University Hospital of Brooklyn December 16, 2005

When Procedural Support really matters. Navien TM A+ Intracranial Support Catheter

CURRICULUM VITAE JAMES ALTON BURKS, JR, MD, MBA, FACS, RVT Enadia Way Van Nuys, CA 91406

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY

STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY

Femoral artery bypass graft (Including femoral crossover graft)

How To Fix A Radial Head Plate

Malfunctioning PD Catheters

Wingspan Stent System with Gateway PTA Balloon Catheter

Strategies to Reduce Catheter Use in 2014

Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up

Liau DW : Injuries and Liability Related to Peripheral Catheters: A Closed Claims Analysis. ASA Newsletter 70(6): & 16, 2006.

Subclavian Steal Syndrome By Marta Thorup

Urinary Diversion: Ileovesicostomy/Ileal Loop/Colon Loop

Ch. 138 CARDIAC CATHETERIZATION SERVICES CHAPTER 138. CARDIAC CATHETERIZATION SERVICES GENERAL PROVISIONS

The care of patients with vascular

Central Venous Lines, PICCs, Ports and Pumps

SUTTER MEDICAL CENTER, SACRAMENTO Department of Cardiovascular Disease Cardiology - Delineation of Privileges

What is Vascular Surgery Worth to a Health Care System?

Factors favoring stent-graft collapse after thoracic endovascular

Lifecheque Basic Critical Illness Insurance

Upper Extremity Arterial Duplex Evaluation

Endovascular Stent Grafts for Disorders of the Thoracic Aorta. Original Policy Date

Perioperative Cardiac Evaluation

Automatic Detection of Stent Graft Markers in 2-D Fluoroscopy Images

Heart Center Packages

INNOVATIONS IN THE ENVIRONMENT: HOW THE HYBRID OPERATING ROOM CAN INFLUENCE CARDIAC SURGERY

TREATMENT OF VARICOSE VEINS: CAN IT BE IMPROVED BY MECHANOCHEMICAL ABLATION USING THE CLARIVEIN DEVICE?

Bard LifeStar Vascular Stent System

Mesenteric Angiography

Delineation of Privileges Department of Surgery/Section of Vascular Surgery. Name: Please print or type

Your Guide to Express Critical Illness Insurance Definitions

First Experience With Drug-Eluting Balloons in Infrapopliteal Arteries

Supera Peripheral Stent System Instructions for Use

ANESTHESIA FOR PATIENTS WITH CORONARY STENTS FOR NON CARDIAC SURGERY. Dr. Mahesh Vakamudi. Professor and Head

California Health and Safety Code, Section

Bard LifeStar Biliary Stent System

Coding Companion for Radiology. A comprehensive illustrated guide to coding and reimbursement

Endoscopic Management of Strictures and Leaks. Prepared by Aurora D. Pryor, MD Presented by Dana Portenier, MD Duke University Medical Center

A Patient s Guide to Primary and Secondary Prevention of Cardiovascular Disease Using Blood-Thinning (Anticoagulant) Drugs

PATIENT INFORMATION BOOKLET

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

Tunneled Hemodialysis Catheters: Placement and complications

Deployment of a Self-expanding Stent in an Artery

Vascular Technology (VT) Content Outline Anatomy & physiology 20% Cerebrovascular Cerebrovascular normal anatomy Evaluate the cerebrovascular vessels

Transcription:

Aptus Endovascular AAA Repair System Report of the 1-year follow-up in a first-in-man study. BY TAKAO OHKI, MD; DAVID H. DEATON, MD; AND JOSÉ ANTONIO CONDADO, MD Since 1991, when Parodi et al1 described a minimally invasive alternative to open abdominal aortic aneurysm (AAA) repair via endovascular repair (EVAR), a variety of methods have been created to mimic principles of the traditional open AAA repair procedure. To date, all endovascular repair devices have a single method for delivery of an endograft into a diseased aorta. Additionally, each endograft relies primarily on the use of an oversized proximal stent, with or without a metallic barb, for fixation to the aortic wall. Experience has shown that these fixation methods can be prone to metal fatigue, as well as proximal stent migration. The Aptus Endovascular AAA Repair System (Aptus Endosystems, Inc., Sunnyvale, CA) divides the endovascular AAA repair procedure into two steps: (1) exclude the aneurysm with an endograft designed to provide radial support while maintaining longitudinal compliance and (2) secure the endograft to the vessel wall with an endovascular stapling system that provides transmural aortic fixation with a high pull-out force proportional to the number of EndoStaples (Aptus) deployed. The Aptus modular endograft is designed specifically for use with the Aptus Endovascular Stapling System, which in turn is designed to provide secure fixation of the proximal edge of the endograft to the infrarenal aortic wall. The modular endograft is designed to accommodate changes in aneurysm and/or aorta morphology without compromising graft integrity, graft patency, or arterial attachment and sealing. In addition, this two-step approach to endovascular AAA repair allows for a significant reduction in the profile and increased flexibility of the delivery systems (endograft and EndoStaples). The modular endograft and the EndoStaple Applier are delivered through a 14-F sheath (16-F outer diameter). These attributes may allow a broader range of patients to be safely treated with an endovascular procedure. The Aptus Endovascular Repair System provides active fixation via an endovascular stapling system that allows placement of EndoStaples along the proximal edge of the main body endograft. The EndoStaple is a 4-mm helical staple manufactured from medical-grade wire designed to engage the full thickness of the aortic wall in an active fashion (Figure 1). STUDY OBJECTIVE The primary objective of this study was to evaluate the feasibility of the Aptus Endovascular AAA Repair System in treating infrarenal abdominal aortic or aorto-iliac aneurysms. A series of intensive bench, animal, and cadaver tests were completed. This first-in-man experience was designed to evaluate the acute safety of the device. STUDY DESIGN This study was a prospective, single-arm, ethics committee-approved study to evaluate the feasibility of the Aptus Endovascular AAA Repair System for treatment of infrarenal abdominal aortic or aorto-iliac aneurysms. No attempt was made to draw statistically valid conclusions regarding safety or performance from this small sample size. Postprocedure follow-up evaluations include 30 days, 6 months, 1 year, and 2 years. Figure 1. The relative scale of an EndoStaple. NOVEMBER 2006 I ENDOVASCULAR TODAY I 29

PREOPERATIVE ASSESSMENT Each patient underwent a contrast-enhanced spiral CT scan with multiplanar reconstruction (M2S, Lebanon, NH) allowing precise measurement of anatomic features of the aneurysm. Patients meeting the inclusion and exclusion criteria and who signed the informed consent were considered candidates for the study. The clinical team included José Antonio Condado, MD, along with Aptus Endosystems clinical proctors Takao Ohki, MD, and David H. Deaton, MD. The first patient was treated by Dr. Condado and Dr. Ohki, and the second patient was treated by Dr. Condado and Dr. Deaton. Patient and case demographics are shown in Table 1. MAIN BODY ENDOGRAFT Two sizes of main bodies were used; the 29-mm endograft was used to treat patient 001, and the 24.5-mm endograft was used to treat patient 002. The Aptus main body endograft is a multilumen endograft composed of a woven polyester graft and nitinol stents. The proximal sealing stent, with diamond-shaped cells, is approximately 14-mm long and is sewn to the inside of the proximal TABLE 1. PATIENT DEMOGRAPHICS Patient 001 Patient 002 Age 71 72 edge of the endograft. It is designed to ensure secure apposition to the vessel wall just below the renal arteries, while being short enough to eliminate metal-fabric interaction. The distal portion of the main body has nitinol stents that function to accept and lock the modular iliac limbs. IMPLANTATION AND ENDOSTAPLING Using fluoroscopic guidance, the main body delivery system catheter was introduced into the vasculature via ipsilateral femoral artery access. The specially designed attachment mechanism allowed the proximal stent to open to its full diameter while remaining tethered to the delivery catheter. The tethered wires along with the radiopaque marker bands on the proximal edge of the main body endograft allowed repositioning of the proximal aspect of the endograft in relation to vascular landmarks. Repositioning is greatly enhanced by the smalldiameter 14-F size of the delivery system. Through contralateral femoral artery access, access to the contralateral gate was obtained in a standard manner utilizing directional catheters and guidewires. Under fluo- Medical history CAD, post-lad PTCA+stent, hypertensive, past smoker, hypercholesterolemia, pulsatile AAA, ulcerative rectocolitis CAD, post-rca PTCA+stent, hypertensive, COPD, hypercholesterolemia, current heavy smoker, asymptomatic AAA with right aorto-iliac aneurysm, left popliteal aneurysm, claudication AAA diameter 6.7 cm 4.3 cm Proximal neck 26 mm 20 mm diameter * Proximal neck 5 mm 9.9 mm length Angulation 63.5 30 R/L iliac diameter 11.5 mm/11 mm 16.5 mm/12 mm Proximal neck shape Reversed conical Straight *Proximal neck outer diameter as measured by core lab standards. Proximal neck length as measured by core lab standards; change in aorta diameter by 10%. Angle of proximal neck to AAA body. 30 I ENDOVASCULAR TODAY I NOVEMBER 2006

Figure 2. The EndoStaple Applier hand control. roscopic guidance, a steerable EndoGuide with obturator (dilator) was positioned over a stiff,.035-inch guidewire within the proximal neck of the main body endograft. Once positioned, the obturator and guidewire were removed, and the distal tip of the steerable EndoGuide was directed toward the desired EndoStaple implant location. A loaded EndoStaple Applier (Figure 2) was inserted through a port in the proximal end of the steerable EndoGuide control handle and advanced until it contacted the endograft wall, as evidenced by deflection of the main body endograft and aortic wall on fluoroscopy as well as by tactile feedback. The EndoStaple Applier is electronically controlled and allows partial deployment and subsequent retraction of the EndoStaple if the initial position of the EndoStaple is deemed unsatisfactory. After confirming that the EndoStaple is in good position, each EndoStaple was fully deployed with a second activation of the EndoStaple Applier (Figure 3). The EndoStaple Applier was then withdrawn from the steerable EndoGuide. The EndoStapling process is repeated by reloading and reinserting the Applier and repositioning the steerable EndoGuide. Initially, a total of four EndoStaples were TABLE 2. ENDOGRAFT COMPONENTS USED deployed circumferentially in each patient. Once stapling was complete, the EndoStaple Applier was removed, and the guidewire was re-inserted for placement of the contralateral lumen extension endograft. The contralateral lumen extension endograft was delivered and deployed into the contralateral gate using standard techniques. At this time, attention was returned to the ipsilateral side. Deployment of the main body endograft was completed by releasing the tethered arms from the main body endograft via a control knob on the delivery system handle. The main body delivery system was retracted into the jacket and removed from the vasculature, leaving the.035-inch guidewire in place for placement of the ipsilateral lumen extension endograft. The ipsilateral lumen extension endograft was deployed in the same manner as described for the contralateral lumen extension endograft. A touch-up angioplasty was performed with large angioplasty balloons (Coda, Cook Incorporated, Indianapolis, IN) in both cases within the proximal sealing stent and the main body/lumen extension overlap junction. Finally, postprocedure angiography was performed. Table 2 summarizes the endograft components implanted in each case. OPERATIVE RESULTS Upon completion of postprocedure angiography in patient 001, a perioperative endoleak of undetermined origin was observed. Bilateral retrograde iliac contrast injections were performed to isolate and identify the source of the endoleak. A proximal contrast injection revealed a type 1 endoleak at the posterior wall of the proximal neck of the main body. Only four EndoStaples had been deployed at this point. Large-balloon angioplasty was performed with the Coda again in the proximal sealing stent without success. Upon further examination of the 3D CT reconstruction, it was realized that the proximal sealing stent was in a very irregular portion of the proximal neck (Figure 4). A decision was made to place three additional EndoStaples over the Patient 001 Patient 002 Main body size 29 mm 24.5 mm Lumen extension endograft R/L size 13 X 10 mm Overall length R/L 160 mm/160 mm 160 mm/140 mm Number of EndoStaples 7 4 32 I ENDOVASCULAR TODAY I NOVEMBER 2006

TABLE 3. PREOPERATIVE AND POSTOPERATIVE DATA FOR PATIENTS 001 AND 002 Follow-up interval AAA Diameter (cm) AAA Volume (cm 3 ) Proximal Neck Angle (º) Patient 001 Patient 002 Patient 001 Patient 002 Patient 001 Patient 002 Preoperative 6.7 4.3 236.9 89.5 63.5 26.9 30 days 6.9 4 226.1 94.3 63.8 29.6 6 months 6.3 4.4 195.4 84.7 49 20.7 1 year 6.7 4.2 200 79.9 55.1 27 % change (preoperative to 1 year) 0% -2% -16% -11% -13% 0% edge of the graft that was not closely applied to the wall. The implantation of three additional EndoStaples in the posterior segment of the sealing stent was performed. Final contrast injection revealed successful resolution of the endoleak. Patient 002 had no evidence of perioperative endoleak based on completion angiogram, and no further stapling was required. In both patients, the main body endografts as well as EndoStaples were deployed immediately below the renal arteries (Figure 3). Acute technical success was achieved in both patients. Both devices were successfully implanted and secured with the EndoStaple system. Total procedure time was 2 hours 37 minutes, and 2 hours 1 minute, respectively (skinto-skin). For patient 001, the EndoStaple time was 23 minutes for the first group of four EndoStaples and 14 minutes for the second group of three EndoStaples. For patient 002, the total EndoStaple time was 16 minutes. Estimated blood loss was 300 ml in each patient, and blood transfusion was not required. POSTPROCEDURE DATA Both patients recovered well. One patient exhibited mild atelectasis from anesthesia. Both patients were discharged on the second postoperative day. Patient 002 presented preoperatively with a concurrent left popliteal aneurysm at the time of his AAA diagnosis. At the time of AAA treatment, the clinical plan was to treat Figure 3. EndoStapling technique with 29-mm MB Endograft in patient 001. Seven EndoStaples were deployed. the patient s popliteal aneurysm after the 30-day followup visit, after AAA repair. However, on day 27 after AAA treatment, the patient reported acute pain in his left leg and presented with ischemia, absent pulses, and numbness in the lower extremity. The symptoms were determined to be related to the pre-existing popliteal aneurysm. Revascularization with a femoropopliteal bypass graft placement was performed; however, the bypass graft occluded the next day resulting in the need for an above-the-knee amputation. There was no evidence to attribute the popliteal aneurysm thrombosis to the Aptus system or the AAA procedure. FOLLOW-UP RESULTS No endograft device complications have been documented perioperatively, postoperatively, or during follow up at 15 months. Figures 4 and 5 show the patients preoperative and 1-year postoperative spiral CT scan reconstructions. Table 3 provides additional preoperative and 1-year postoperative data for each patient. While the reported AAA diameter showed little change during the 1-year period, overall AAA sac diameter decreased 16% and 11%, respectively, in each patient. Over the same period, patient 001 showed a 13% decrease in proximal neck angle commensurate with the reduction in sac volume. In both cases, the proximal stent and the EndoStaples were located immediately below the renal arteries suggestive of the absence of proximal stent migration. 34 I ENDOVASCULAR TODAY I NOVEMBER 2006

surgical repair for the treatment of AAA. Its relative safety and reduction in aneurysm-related mortality has been proven in at least two randomized trials. 2,3 However, several factors continue to limit the wider use of EVAR, including the ongoing risk of proximal stent migration, durability, risk of vascular injury, and access-related issues due to the large-bore delivery system and inability to treat short and angulated proximal aortic necks. With the low-profile delivery system and unique fixation method of the Aptus Endovascular AAA Repair System, we believe this third-generation endovascular repair system has the potential to further improve the outcome and penetration of EVAR procedures. Figure 4. 3D CT reconstructions of preoperative and 1-year postoperative imaging for patient 001. DISCUSSION The Aptus Endovascular AAA Repair System was safely implanted in these two patients. Both patients tolerated the procedure well, and recovery through hospital discharge was unremarkable. The CT evaluations through 1 year for both patients indicate stable device positioning (no migration) and good aneurysm exclusion. There were no type I, III, or IV endoleaks or device-related complications. At 6 months, a small type II lumbar endoleak (0.5 ml) was documented by CT scan in patient 001. At 1 year, the type II endoleak was reduced by 20% (0.2 ml). EVAR has been established as an alternative to open Figure 5. 3D CT reconstructions of preoperative and 1-year postoperative imaging for patient 002. CONCLUSION This initial experience established the feasibility of endovascular AAA repair using the Aptus Endovascular AAA Repair System. The data on these two patients support further clinical evaluation of this technology. A US Feasibility trial is currently underway. David H. Deaton, MD, is Chief of Endovascular Surgery, Division of Vascular Surgery/Georgetown University Hospital, Washington, DC. He has disclosed that he receives expense reimbursement as a Scientific Advisory Board member for Aptus Endosystems, as well as a Clinical Proctor for the Aptus STAPLE-1 US Clinical Investigation. He is also a Principal Investigator in the STA- PLE-1 study. Dr. Deaton may be reached at (202) 444-1265; david@deaton.md. Takao Ohki, MD, is Professor and Chief, Department of Vascular Surgery, Jikei University School of Medicine, Tokyo, Japan; North Shore LIJ Health System, Albert Einstein College of Medicine, Lake Success, New York. He has disclosed that he is an investor in, and Scientific Advisory Board member for, Aptus Endosystems, Inc. Dr. Ohki may be reached at (516) 233-3600 or +81-3-3433-1111 ex. 3400 (Japan); takohki@msn.com. José Antonio Condado, MD, is with Hospital Centro Médico de Caracas in Caracas, Venezuela. He has disclosed that he received expense reimbursement from Aptus Endosystems for expenses related to the conduct of this study, as well as remuneration for consultation services. Dr. Condado may be reached at +58 (212) 552 5262. 1. Parodi JC, Palmaz JC, Barone BD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysm. Ann Vasc Surg. 1991;5:491-499. 2. EVAR trial participants. Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial. Lancet. 2005;365:2179-2186. 3. Blankensteijn JD, de Jong SE, Prinssen M, et al. Dutch Randomized Endovascular Aneurysm Management (DREAM) Trial Group. Two-year outcomes after conventional or endovascular repair of abdominal aortic aneurysms. N Engl J Med. 2005;352:2398-2405. 36 I ENDOVASCULAR TODAY I NOVEMBER 2006