ENVIRO-SEAL. Valve Packing Systems Extending service life. Meeting environmental requirements.



Similar documents
Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Fisher GX Control Valves

Baumann Way Bronze or Stainless Steel Control Valve

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Baumann Little Scotty Bronze Control Valve

Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability

Baumann Mikroseal Control Valve

Fisher 377 Trip Valve

Baumann Flexsleev Sanitary Control Valve

4310/4320 Wireless Position Monitor

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

Fisher 657 and 667 Diaphragm Actuators

Fisher CV500 Rotary Globe Control Valve

Fisher 8580 Rotary Valve

Baumann 24000SB Barstock Control Valve

ValveLink Software Quick Start Guide

Fisher D3 Control Valve

ValveLink Mobile Software

Fisher Vee-Ball Rotary Control Valves Highly efficient rotary valves to meet a variety of applications

Packing and gaskets Page 029 of 040

Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Control Valve Training Course Program

Integrated Custom Systems

1805 Series Relief Valves

Fisher 249 Caged Displacer Sensors

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

HIGH STANDARD VALVES FOR NON-STANDARD CONDITIONS.

Fisher 2625, 2625SST, and 2625NS Volume Boosters

4310/4320 Wireless Position Monitor Burst Configuration and Diagnostics

FIELDVUE. DVC6200 Series Digital Valve Controller A Single Instrument Solution Across Your Facility

Fisher GX 3-Way Control Valve and Actuator System

Fisher V500 Rotary Globe Control Valve

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

Fisher ES and EAS Sliding-Stem Control Valves

Valve Live Loading With Belleville Springs. Belleville Springs for Valve Live Loading

Basic Fundamentals Of Safety Instrumented Systems

289 Series Spring-Loaded Relief Valves

BY MCI SOLUTIONS SECONDARY CONTAINMENT ADAPTOR

Fisher EDR and ETR easy-e Valves

AMS ValveLink SNAP-ON Application

Simulation of Process Conditions for Calibration of Fisher Level Controllers and Transmitters Supplement to 249 Sensor Instruction Manuals

API Flanged Safety Relief Valves Series 526 CATALOG

QUADRANT SR- Thermal Oxidizer Process Design & Environmental Control Benefits for the Sand Coating Industries

Type 92S Pilot-Operated Steam Regulator

Type 119 Control Valve

Fisher 377 Trip Valve

COLORADO REGULATION 7

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Fisherr 8510 and 8510B Eccentric Disc Control Valves (EMA)

Fluid Automation: The Unsung Contributor to Plant Economic Performance. A Management Brief From ASCO Numatics

Fugitive emissions: guidelines for successful valve upgrades

Types 66R and 66RR Low-Pressure Relief Valves

Fisher 4320 Wireless Position Monitor, with On/Off Control Option

Fisher HP Series Control Valves

BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS. November 06, 2014 By: François Thibodeau, Eng.

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve

Fisher A11 High-Performance Butterfly Valve

Easy Tool Retracting System CMC-SR2159ER36

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Select the Right Relief Valve - Part 1 Saeid Rahimi

Fluid Automation Solutions

AMS Suite: Intelligent Device Manager

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Fisher GX Control Valve and Actuator System

Fisher CV500 Rotary Globe Control Valve

How To Make A Pressure Relief Valve

INSTRUMENTATION & CONTROLS VALVE & AUTOMATION EXPERTS VALVE REPAIR TUBE SERVICES

Emergency Shutoff Valves for Fuel, Oil and Gas Service. Approved by FM, CSA and TÜV

AMS Suite: Intelligent Device Manager with the DeltaV system

Kämmer Series Laboratory Valves

Specification Data CM /10. Putting You In Control Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

167D Series Switching Valves

NELES SOFT SEATED BUTTERFLY VALVE SERIES MAPAG BA FOR PSA PLANT ON/OFF AND CONTROL SERVICE

Daniel Venturi Tubes and Flow Nozzles Brochure

Our Know-How. Your Peace of Mind. Innovative Sealing and Gasket Solutions

Torlon is a registered trademark of Solvay Specialty Polymers USA, LLC Fluorosint is a registered Trademark of Quadrant EPP

CCI 100 DPC DRAG Wellhead Production Choke Valve

DOUBLE BLOCK AND BLEED VALVES

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Full-time Career Opportunities Launch Your Career with Emerson

Fisher 8532 High-Performance Butterfly Valve

Trunnion-Design Ball Valves

Cummins. Remanufacturing. Genuine Performance. Every Time.

Fisher Vee-Ball V150, V200, and V300 Rotary Control Valves

THE DETECTION OF GREENHOUSE GASES

GS-General Service Control Valves

FLANGED END BALL VALVE

Valve Packing and the Nuclear Industry

Fisher ET, EAT, and ETR Sliding-Stem Control Valves

Green Thread Product Data

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

The First Line of Safety

Tips for a Successful Diesel Retrofit Project

Transcription:

Valve Packing Systems Extending service life. Meeting environmental requirements.

2 Valve Packing Systems valve packing systems: Designed specifically to reduce your total cost of ownership for non-environmental and environmental sealing applications while optimizing process control.

Valve Packing Systems 3 Valve Packing Systems The right choice for extended service life in nonenvironmental and environmental applications. E merson s Fisher packing systems minimize operating expenses over the life of control valves. CONTENTS: systems are available for a wide range of pressure and temperature conditions in non-environmental and environmental applications. They re designed to control emissions to below 100 parts per million volume (ppmv), which makes them a good choice for the chemical, oil and gas, and pulp and paper industries. 4 The Design 6 Environmental Requirements 8 Peace of Mind by Design 9 Performance Testing Why use packing systems? You must control maintenance and environmental costs in today s competitive markets. A proven way to reduce packing maintenance, enhance process control, and minimize labor costs is to use Fisher packing systems 10 Standardize Across the Plant 11 The Next Step in your rotary and sliding-stem valves. Our control valve design and research engineers, the individuals who know control valve sealing technology the best, developed and extensively tested systems. Valve users put the systems to work in a wide variety of applications., introduced in the early 1990s, today stands as the system of choice worldwide, both for extended service life and stringent emission control. In addition, systems have been tested and certified by international certification organizations.

4 Valve Packing Systems The Design Avoiding valve trouble requires a packing system that has a managed stress level, ensures proper stem or shaft alignment, contains the correct amount of packing material, and offers packing containment. packing systems use four principles in their designs. Four Packing System Principles: (1) Managed Stress - Live-load Belleville springs provide a constant load over the life of the packing material. (3) Optimized Amount of Packing - The system uses just the right amount of packing depth for the stem or shaft diameter. (4) Packing Containment - Anti-extrusion rings keep the packing from extruding when it deforms to fill space between the stem and bore. Choose PTFE, Graphite ULF (ultra low friction) or Duplex configurations for sliding-stem valves. For rotary valves, select PTFE or Graphite configurations. (2) Aligned Properly - Lined packing followers ensure that the valve stem or shaft is held precisely in the center of the packing. Anti-extrusion ring Packing set Packing follower Belleville springs CAPABILITY Extended service life Fugitive emissions control Tight sealing High performance level Low friction Minimal maintenance Wide pressure/temperature range Fits sliding-stem and rotary valves Accurate control with Fisher valves Firesafe

Valve Packing Systems 5 A Case-In-Point A Canadian urea plant experienced continual stem leakage problems with its NPS 8 butterfly valve that was used to maintain liquid level in the reactor. Plant personnel tried tightening, repacking, and injecting a sealing compound into the packing, which used PTFE rings. Valve stem leakage was severe enough to close down operations twice in one year at $500,000 per day in lost production. The packing system was installed as a solution. After one year of service, the packing system showed absolutely no sign of leakage. Periodic inspection of the packing follower revealed negligible travel, indicating that the packing was operating without extrusion loss. By using the packing, the plant avoided the potential for a million dollars of shutdown loss per year as well as relieving a major operations and maintenance headache. Rotary Sliding Stem >> >> PTFE Universal chemical compatibility makes PTFE the first choice of chemical plants and pulp mills. >> Graphite ULF Extended pressure and temperature capability combined with ultra low friction keeps critical power plant and refining valves operating smoothly. >> Duplex High-performance firesafe packing perfected for the refining industry. >>

6 Valve Packing Systems is Your Low-Emissions (Low-E) Packing Solution You can no longer select a valve packing system based on price alone. A low-priced system may give months of leak-free service. But when it does start to leak, maintenance costs add up. packing systems keep emission concentrations below mandated limits, such as the U.S. Environmental Protection Agency (EPA) threshold of 500 ppmv to meet Leak Detection and Repair (LDAR) programs. In fact, testing shows packing systems can control emissions to below 100 ppmv. Emerson offers an optional, extended warranty for customers required by the EPA to implement an Enhanced LDAR Program (ELP) and limit emissions to 100 ppmv. Contact your Emerson local business partner or sales office for more information. Keep Emissions Below 100 ppmv Using FIELDVUE Digital Valve Controllers Maintenance personnel can utilize actuator cycle counts to monitor packing systems. FIELDVUE instruments can count the number of cycles the valve assembly completes. ValveLink software keeps a history of these counts. When the valve exceeds a specified number of cycles, ValveLink software can generate a FIELDVUE alert. Based on actual valve service performance, this alert reminds maintenance personnel to check packing for integrity. Low-E Packing Solution packing systems meet ELP fugitive emissions requirements. GX Control Valve with Packing System The GX control valve and actuator system gives you a single valve that you can use effectively in a wide variety of applications. It meets elevated temperature requirements, up to 371 C (700 F), and can handle rigorous mechanical and thermal cycles. packing systems are standard in the GX. Engineered Retrofit and Repair Kits Available If your maintenance staff is short-handed or just too busy to replace your valve seals, contact Emerson s Instrument & Valve Services for onsite valve repacking.

Valve Packing Systems 7 A Case-In-Point A refinery in the southern U.S. utilized packing that was firesafe but didn t keep valve emissions below 100 ppmv, as dictated by area regulations. The plant installed Duplex packing systems on four control valves. The valves were in C 3 and C 4 hydrocarbon service and operated at 32 C to 49 C (90 F to 120 F) and a maximum pressure of 21 bar (300 psi). Three years after installation, leak rates on the four valves have been exceptionally low. The maximum hydrocarbon concentration ever detected was less than 20 ppmv. The Duplex systems have not needed readjusting since they were installed. Company-wide specifications have now been developed that standardize on Duplex packing systems for applications requiring low fugitive emissions, low stem friction, and fire safety. Bellows When combined with packing, bellows provide the ultimate protection against leakage. Certifications packing systems have been certified for a broad range of service conditions. They offer excellent emission control capabilities and have been tested and certified by these international certification organizations: Cetim (ISO 15848-1), Yarmouth (ANSI/FCI 91-1, Shell MESC SPE 77/300), and TÜV (TA-Luft).

8 Valve Packing Systems Peace of Mind by Design here is a difference between live-loaded packing T systems. Ask your control valve or packing supplier to verify that his packing system has passed each of the following tests. Was the packing system tested to recognized industry standards? Fisher packing systems have been tested across a broad range of conditions to demonstrate compliance with numerous industry standards including ISO 15848-1, ANSI/FCI 91-1, and TA-Luft. Was the packing system engineered specifically for the valve style you intend to use? Packing performance is influenced not only by valve geometry but also by valve design features. Fisher packing systems fit Fisher control valves as shipped. There is no need to force-fit generic, non-oem packing into your control valve. Was the packing system subjected to multiple operating cycles? The packing system should be subjected to extensive mechanical testing. Did testing of packing systems for rotary valves include deflection of the valve shaft? Pressure drop across the valve plug and the resulting side loads imposed in rotary valves can distort packing, create leak paths, and limit packing life. Was stem leakage monitored using EPA Method 21? EPA Method 21 measures the concentration of VOCs near the valve stem and is the only appropriate technique for qualifying LDAR monitoring frequencies in the U.S. Were packing system components examined for wear after the completion of each test? After each test, the valve stem should be checked for scoring, wear, corrosion, or erosion. Was the compression load on the packing measured as each test progressed? Packing systems based on PTFE sealing elements can gradually lose packing volume. The monitoring of packing load during the test period can detect loss of packing volume and can aid in predicting ultimate packing failure. Was the packing system subjected to multiple thermal cycles? Generally, a packing system that demonstrates continued low leakage after numerous thermal cycles while experiencing thousands of mechanical cycles is sufficiently stable to perform through continued thermal cycling. Were packing adjustments made or was the packing system maintained during the performance test? Packing that must be maintained or adjusted in order to retain its low leak rate jeopardizes the goal of annual LDAR regulation. Was the packing system tested at or above the service conditions of your application? The combination of high pressure and temperature can increase the leak potential and can limit the service life of a packing system.

Valve Packing Systems 9 Performance Testing Fisher Graphite ULF Non-OEM Expandable Graphite Non-OEM Wedge-Shaped Graphite Non-OEM Flexible Graphite Jacket Over Carbon Core Stem Friction (lbs) 1200 1000 800 600 400 200 Valve Stem Friction at Ambient Temperature for Newly-Installed, Emission-Rated Graphite Packing Sets 0 0 1000 2000 3000 4000 5000 6000 Packing Stress (psi) Fisher easy-e sliding-stem valve with Graphite ULF system 10000 1500 psig Methane Leakage at Ambient Temperature for Newly-Installed, Emission-Rated Graphite Packing Sets Packing Leakage (PPMv) 1000 100 10 1 0 1000 2000 3000 4000 5000 6000 Packing Stress (psi) 10000 1500 psig Methane Leakage for Emission-Rated Graphite Packing Sets Tested From 70 F to 600 F Without Adjustment Packing Leakage (PPMv) 1000 100 10 1 0.1 0 10000 20000 30000 Mechanical Cycles

10 Valve Packing Systems Standardize Across the Plant packing systems are available in all Fisher valves, which means you can take advantage of their excellent sealing and extended service capabilities throughout your plant. Support and Service Emerson Process Management Educational Services offers training for technicians, engineers, and others responsible for installing, troubleshooting, and replacing parts on valves and actuators. Whether it s diagnostic services, valve repair, or parts, we understand the relationship between our prompt service and your profitability. With locations throughout the world, Emerson can provide the valve maintenance you need, when you need them. Fisher eccentric plug rotary control valve with PTFE packing system

Valve Packing Systems 11 The Next Step If you like the advantages given by packing systems, call your Emerson local business partner or sales office. Highly skilled and experienced applications experts are ready to help you take advantage of the many benefits of systems. Visit www.fisher.com to locate an office near you. When you need process automation products, turn to Emerson Process Management for an extensive lineup of measurement and analytical instruments, final control devices, and systems and software. systems help reduce maintenance costs and extend service life in non-environmental and environmental applications. The temperature ratings shown in the table below apply to the actual packing temperature, not the process temperature. packing systems can be used across the full temperature capability range of Fisher control valves. Packing Pressure and Temperature Selection Guidelines (1)(2) Valve Type Sliding Stem Packing System PTFE Non-environmental Service (3) Environmental Service (3) Metric Imperial Metric Imperial -46 to 104 C 259 bar 104 <_ 232 C decreasing to 103 bar -50 to 220 F 3750 psi 220 <_ 450 F decreasing to 1500 psi -46 to 93 C 52 bar 93 <_ 232 C decreasing to 30 bar -50 to 200 F 750 psi 200 <_ 450 decreasing to 450 psi Sliding Stem Duplex -46 to 104 C 259 bar 104 <_ 232 C decreasing to 103 bar -50 to 220 F 3750 psi 220 <_ 450 F decreasing to 1500 psi 51.7 bar -46 to 232 C 750 psi -50 to 450 F Sliding Stem Graphite ULF 207 bar -198 to 371 C 3000 psi -325 to 700 F 103 bar -7 to 315 C 1500 psi 20 to 600 F Rotary PTFE 103 bar -46 to 232 C 1500 psig -50 to 450 F 103 bar -46 to 232 C 1500 psig -50 to 450 F Rotary Graphite 207 bar -198 to 371 C 3000 psig -325 to 700 F 103 bar -18 to 315 C 1500 psig 20 to 600 F 1. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. 2. Complete specifications can be found in Fisher Bulletin 59.1:061 Packing Systems for Sliding-Stem Valves and Fisher Bulletin 59.3:041 Packing Systems for Rotary Valves. 3. The values shown are only guidelines. These guidelines can be exceeded, but shortened packing life or increased leakage might result. The temperature ratings apply to the actual packing temperature, not to the process temperature.

main red C0 M96 Y90 K2 white C0 M0 Y0 K0 gradient bottom C13 M96 Y81 K54 black C100 M100 Y100 K100 YOUTUBE LOGO SPECS PRINT on light backgrounds standard on dark backgrounds standard PMS 1795C PMS 1815C WHITE BLACK no gradients no gradients watermark watermark http://www.facebook.com/fishervalves http://www.twitter.com/fishervalves stacked logo (for sharing only) stacked logo (for sharing only) http://www.youtube.com/user/fishercontrolvalve http://www.linkedin.com/groups/fisher-3941826 To find the Emerson sales contact in your area, scan the QR code. 2003, 2013 Fisher Controls International LLC. All rights reserved. Fisher,, FIELDVUE, ValveLink, and easy-e are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, nothing herein is to be construed as a warranty or guarantee, express or implied, regarding the products or services described herein or their use, performance, merchantability or fitness for a particular purpose. Individual results may vary. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Responsibility for proper selection, use and maintenance of any product or service remains solely with the purchaser and end user. D351050X012 / MZ100 / Apr13