Blood Glucose Monitoring: The Facts about Accuracy



Similar documents
Evaluation of Accuracy and User Performance of the TRUE METRIX Self-Monitoring Blood Glucose System *

FDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs)

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

Validation and Calibration. Definitions and Terminology

Accuracy Test Omnitest 3 Blood Glucose Monitoring System. B. Braun Diabetes Care

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

An important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and

A comparison of blood glucose meters in Australia

Accu-Chek Inform II system. Professional glucose testing for the wireless age

Blood Glucose Monitoring Test Systems for Prescription Point-of- Care Use Draft Guidance for Industry and Food and Drug Administration Staff

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Practice Advisory Blood Glucose Meter Accuracy Issued September 16, 2013

Lab: Graphing Activities TOTTEN

Performance Variability of Seven Commonly Used Self-Monitoring of Blood Glucose Systems: Clinical Considerations for Patients and Providers

General. What is a laboratory test? What is a waived test?

MEDICAL DEVICE GUIDANCE

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

I know my value. CoaguChek XS Plus system Smart INR monitoring at your practice. 1 of 6

SKUP Scandinavian evaluation of laboratory equipment for primary health care

Biochemistry Validation Form

Onboard Quality Controls for the CoaguChek XS System

Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate of Waiver

Section 5: Quality Systems Regulation (QSR) and Good Manufacturing Practice (GMP)

STANDARD OPERATING PROCEDURE FOR NOVA STAT STRIP CONNECTIVITY BLOOD GLUCOSE METERS FOR USE IN LEEDS NHS TRUST

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

A guidebook for people with diabetes

Preface. Preface. A Healthcare professional should be contacted when Customer Service is not available.

BLOOD GLUCOSE METER. Standard Owner s Booklet for Single Patient Use Only

Title: Fingerstick Glucose by Accu-Chek Inform

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

The OmniPod Insulin Management System

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

BLOOD GLUCOSE METER. Getting Started Guide for Single Patient Use Only

Self-Monitoring of Blood Glucose

Analytical Methods: A Statistical Perspective on the ICH Q2A and Q2B Guidelines for Validation of Analytical Methods

US Diabetic Devices Industry Research Report: KenResearch

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

AP BIOLOGY 2010 SCORING GUIDELINES

In vitro diagnostic reagent, calibrator and control material stability

Using Current Transformers with the 78M661x

rtech laboratories began working toward ISO 9002:1994 in ISO 17025: Practical Benefits of Implementing a Quality System STATISTICAL ANALYSIS

Center for Clinical Standards and Quality/Survey & Certification Group

ph: Measurement and Uses

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Accu-Chek Connect Online diabetes management system. Setup Guide for Healthcare Providers

Enzyme Action: Testing Catalase Activity

Gage Studies for Continuous Data

Lab 2. Spectrophotometric Measurement of Glucose

Determination of Insoluble Solids in Pretreated Biomass March 2008 Material

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

digital fever alert ear thermometer suitable from birth instruction manual

Basic Lessons in Laboratory Quality Control

Introduction to Biosensors. Professor Brian Birch LIRANS University of Luton UK

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)

Valve Steel. Valve Steel

Who gets you to the next level?

Nova Max Blood Glucose Monitor Owner s Guide

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Key Features in the AgaMatrix Jazz

Blood Glucose Monitoring System USER GUIDE. Replaces Owner s Booklet

Catalase. ***You will be working with hot water, acids and bases in this laboratory*** ****Use Extreme Caution!!!****

How to Verify Performance Specifications

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

INTRODUCTION TO CLINICAL PRACTICE AND CLINICAL SKILLS 2nd Year MEDICAL YEAR 2009/2010

INTRODUCTION TO MACHINE-VISION INSPECTION

Laboratory 5: Properties of Enzymes

Q1: The following graph is a fair to good example of a graph. In the t-chart, list what they did well and what they need to fix.

Assay Migration Studies for In Vitro Diagnostic Devices Guidance for Industry and FDA Staff

THE LABORATORY NOTEBOOK

USE OF REFERENCE MATERIALS IN THE LABORATORY

Enzyme Action: Testing Catalase Activity

Relative Humidity Calibration Kit

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

Instruction Manual Temp 4/5/6 Temperature Meter Series

Test strips and meter designed for glucose self-measurement manufactured by Abbott. Report from an evaluation organised by SKUP

Evaluating Current Practices in Shelf Life Estimation

Balance Accuracy. FlexiWeigh

21 CFR Part 11 White Paper

Statistical estimation using confidence intervals

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

MANUAL TR-110 TR-110

Content Sheet 5-1: Overview of Sample Management

99.37, 99.38, 99.38, 99.39, 99.39, 99.39, 99.39, 99.40, 99.41, cm

SMF Awareness Seminar 2014

ASSURING THE QUALITY OF TEST RESULTS

Current Monitoring Kit

Experiment 1: Measurement and Density

GROUP MEDICARE SUPPLEMENT PLANS. S5753_081213_GB03_MN Internal Approval 08/13/2013

BLOOD GLUCOSE METER / GLYCOMÈTRE. User s Manual Manuel de l'utilisateur

Guidance for Industry

Transcription:

Blood Glucose Monitoring: The Facts about Accuracy Summary The purpose of this document is to provide the facts about the accuracy of self-monitoring of blood glucose (SMBG) systems. Accuracy can be defined as the closeness of agreement of a test result with an accepted reference value. There are multiple drivers of accuracy, including manufacturing processes, environmental factors and patient use. All SMBG systems approved by the U.S. Food and Drug Administration (FDA) must meet the minimum 15/20 requirements of ISO 15197. While multiple studies assert accuracy claims, one manufacturer has proven the ability to exceed this standard across all lots of product produced.

Defining Accuracy SMBG system accuracy is defined as the closeness of agreement of a test result with an accepted reference value. 1 There are multiple drivers of accuracy, including manufacturing processes, environmental factors and individual patient use. System accuracy is independent from system precision. An SMBG system that delivers precise, or consistent, results is not necessarily guaranteed to be accurate. System accuracy is important, as SMBG readings may affect clinical decisions. A blood glucose reading is often referred to as clinically accurate if it would allow for a correct clinical decision to be made. 3

FDA Requirements for Accuracy of SMBG Systems The FDA requires all manufacturers of SMBG systems to meet the ISO 15197 standard set by the International Organization for Standardization (ISO) in 2003. It states that the minimum acceptable accuracy for results produced by a glucose monitoring system shall be as follows: 95% of individual glucose results shall fall: 2 Within ±15 mg/dl of the results of the manufacturer s measurement procedure at glucose concentrations <75 mg/dl And within ±20% at glucose concentrations 75 mg/dl SMBG manufacturers must submit test results from one lot of product to the FDA to demonstrate adherence to these standards. A lot is defined as a batch of product manufactured under uniform conditions during a set period of time. Most lots consist of several thousand vials of test strips. 4

Roche s Commitment to Quality Roche, the maker of ACCU-CHEK products, is committed to manufacturing quality products that provide accurate results. In fact, the ACCU-CHEK Aviva Plus test strip was developed to meet an even higher accuracy specification that is consistent with what AdvaMed, the association of companies that produce medical device and diagnostic products, advocates. 3 With this tighter specification, patients can have even more confidence in the accuracy of their blood glucose results. Acceptance criteria Current Standard ISO 15197: 2003 ACCU-CHEK Aviva Plus test strip 95% of individual glucose results shall fall within ±15 mg/dl of the reference results at glucose concentrations less than 75 mg/dl and within ±20% at glucose concentrations greater than or equal to 75 mg/dl 95% of individual glucose results shall fall within ±15 mg/dl of the reference results at glucose concentrations less than 100 mg/dl and within ±15% at glucose concentrations greater than or equal to 100 mg/dl The ACCU-CHEK Aviva Plus test system was tested against and meets an accuracy specification that is 23% tighter than the current ISO standard. This means that a smaller bias is expected between the meter s blood glucose result and the reference value when using the ACCU-CHEK Aviva Plus test strip versus systems that only meet the ISO standard. Accuracy comparison 600 550 500 The ACCU-CHEK Aviva Plus test strip results The ACCU-CHEK cover an area Aviva 23% Plus smaller test strip than the results area defined cover an by area the 23% ISO smaller standard. than the area defined by the ISO standard. Blood Glucose Result (mg/dl) 450 400 350 300 250 200 150 100 Current ISO standard ACCU-CHEK Aviva Plus test strip 50 Current ISO Standard ACCU-CHEK Aviva Plus Test Strip 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Reference Method (mg/dl) 5

As the following chart depicts, a 15/15 standard at a 100 mg/dl breaking point is tighter than the current standard for blood glucose values >75 mg/dl. By changing the break point to 100 mg/dl, the accuracy level is maintained at blood glucose values 75 mg/dl, and accuracy is increased at >75 mg/dl. bg Value (mg/dl) Current Standard (15/20% with 75 mg/dl break point) Tighter Specification (15/15% with 100 mg/dl break point) 60 ±15 mg/dl ±15 mg/dl 75 ±15 mg/dl ±15 mg/dl 80 ±16 mg/dl ±15 mg/dl 90 ±18 mg/dl ±15 mg/dl 100 ±20 mg/dl ±15 mg/dl 110 ±22 mg/dl ±16.5 mg/dl We believe that while accuracy is an extremely important factor in the use of blood glucose monitors, it is only one component in the total performance of a blood glucose system. We focus on each of the following areas to ensure our testing supplies are safe, accurate and effective. We employ quality checks to ensure that every single lot of ACCU-CHEK Aviva Plus test strips meets this tighter accuracy specification. For every ACCU-CHEK Aviva Plus test strip lot produced: We test 1 out of every 100 vials for homogeneity or consistency of performance. As each lot has thousands of vials, this process is quite labor intensive. We test vials that are representative of the entire lot a second time. Some are tested in a lab; others are tested with capillary blood from actual patients with diabetes to reflect a real-world environment. Only those lots that achieve the acceptance criteria based on the tighter accuracy specification are released into the market. These quality checks ensure that ACCU-CHEK Aviva Plus test strips are safe, accurate and dependable. All SMBG systems cleared by the FDA must meet the ISO 15197 standard. 6

Ensuring Adherence to Accuracy Requirements Manufacturers must calibrate SMBG systems against a lab reference method to ensure adherence to the ISO 15197 accuracy standard. Three different types of lab reference methods exist: 4 Glucose oxidase Glucose dehydrogenase Glucose hexokinase All three methods detect glucose without suffering greatly from interfering substances. The primary differences between them are the enzyme system and the technique used for detecting glucose. The most commonly used methods glucose oxidase and glucose hexokinase are examined below. Lab Reference* Enzyme System Used Technique for Detecting Glucose Popular Brand of Analyzer glucose oxidase glucose oxidase electrochemical YSI 2300 STAT Plus glucose hexokinase hexokinase and glucose-6-phosphate dehydrogenase spectrophotometric (optical) Roche Hitachi 917 * Most SMBG systems in the U.S. are calibrated using a glucose oxidase lab reference method. ACCU-CHEK products are calibrated using a glucose hexokinase reference method. While SMBG systems must be calibrated against a lab reference method, variations between different reference methods exist. 7

Guidelines for Accuracy Evaluations In addition to stating the minimum standard for SMBG system accuracy, ISO 15197 also outlines requirements for accuracy evaluations. Examples include: 5 1. Scope and Setting System accuracy should be evaluated with at least 100 different subjects over at least 10 days. Ideally, measurement should take place in a diabetes outpatient clinic or hospital setting. 2. Appropriate Reference Methods SMBG readings should be compared to reference values determined by the manufacturer s measurement procedure. In other words, an ideal evaluation would use the lab reference method that the SMBG system was designed to be calibrated with as a point of comparison. This information can be found on an SMBG manufacturer s product labeling. 3. Range of Glucose Samples Accuracy evaluations should use capillary blood and should include glucose samples that are representative of a wide range of meter operation. The table below illustrates the percentage of glucose samples that should fall within each glucose concentration range. Percentages of samples % Glucose concentrations mg/dl 5 <50 15 50 80 20 80 120 30 120 200 15 201 300 10 301 400 5 >400 4. Lot Inclusion A single lot may be evaluated if data demonstrates that variability across lots is minor. However, many manufacturers choose to examine multiple lots in order to demonstrate robustness of product performance. Manufacturers should adhere to ISO guidelines when conducting accuracy evaluations for SMBG systems. 8

Examining Accuracy Claims A variety of SMBG accuracy studies have been published. Five critical questions must be asked when evaluating these studies and the subsequent claims they have produced. Questions Considerations Was the study conducted by an objective third party? Use of an objective third party prevents manufacturers from tailoring a study to demonstrate favorable performance. For example, a specific lot may be selected to provide betterthan-expected performance. How many lots were tested? (Some manufacturers refer to lots as batches. ) Use of only one lot allows for tailoring a study toward favorable performance. Using multiple samples across various lots provides a better indication of actual manufacturing output. Did the study follow ISO 15197 requirements for proper use of lab reference methods? ISO 15197 requires that accuracy evaluations use the lab reference method indicated on an SMBG manufacturer s labeling. This ensures consistency with how the system was designed. Did the study follow ISO 15197 requirements for correct glucose concentrations of samples? ISO 15197 requires that capillary evaluations of system accuracy include glucose samples that range from <50 mg/dl to >400 mg/dl. Does the accuracy claim represent all lots being manufactured? Accuracy claims are valid for the specific lots tested within a particular study. But unless a manufacturer aligns its quality control process accordingly, it cannot ensure that all lots produced meet the claim. 9

External Factors That Affect Accuracy Accuracy is inherent in SMBG systems, but it can also be driven by environmental factors, such as: Temperature Humidity Altitude Human factors can also affect SMBG accuracy. These can often be corrected through proper patient training. Inadequate blood drop obtained Blood incorrectly applied to test strip Test strip inserted into meter incorrectly Alcohol, if used, not allowed to dry before testing Use of expired test strips Improper coding Ineffective hand washing 10

Challenges in Comparing SMBG System Results All SMBG systems must meet the ISO 15197 standard. However, when two different systems are compared, their test results may be different. The following two scenarios illustrate how this can occur. Scenario 1 System A and system B were both calibrated using the same lab reference method Reading from SMBG system A deviated from lab result by +10% Reading from SMBG system B deviated from lab result by -10% Results from two systems deviate from each other by 20 percentage points Scenario 2 System A and system B were calibrated using different lab reference methods Reading from SMBG system A deviated from lab result by +10% Reading from SMBG system B deviated from lab result by -10% Results from two systems could deviate from each other by more or less than 20 percentage points because they were calibrated using two different lab reference methods These scenarios illustrate the challenge in directly comparing readings from one SMBG system to another. Two SMBG systems can both meet the ISO 15197 accuracy standard but provide two different blood glucose readings. 11

Evaluating Clinical Impact To help overcome the challenge of comparing two different systems, industry professionals often refer to clinical accuracy. A blood glucose reading is clinically accurate if it would allow for a correct clinical decision to be made. A consensus error grid* can be used to assess the clinical accuracy of SMBG systems. 6 This grid places SMBG-measured glucose results on the y-axis and actual glucose results as measured by a lab analyzer on the x-axis. The risk posed by discrepant readings is categorized by five zones, labeled A through E. Graph depicting suggested new standards Parkes Error Grid FPO Zone A: No effect on clinical action Zone B: Altered clinical action little or no effect on clinical outcome Zone C: Altered clinical action likely to affect clinical outcome Zone D: Altered clinical action could have significant medical risk Zone E: Altered clinical action could have dangerous consequences * Both the Parkes Error Grid and Clarke Error Grid are used to examine clinical accuracy. The Parkes grid is portrayed above, as it was developed more recently and is increasingly used by SMBG manufacturers in clinical studies. The primary difference between the grids is the placement of dividing lines between zones. 12

Recall that ISO 15197 requires that 95% of SMBG glucose results fall: 2 Within ±15 mg/dl of the results of the manufacturer s measurement procedure at glucose concentrations <75 mg/dl. And within ±20% at glucose concentrations 75 mg/dl. SMBG results that meet this criteria should fall within Zone A and allow for correct patient treatment. If two different SMBG readings both fall into Zone A, they are both clinically accurate. 13

Accuracy Interferences and System Limitations Safeguards Total System Performance Labeling Quality Assurance Support and Education Interference and Use Limitation Testing We test for more than 190 of the most common and known interferences. We believe that this is roughly 7 times the number tested by other major manufacturers. 7 System Safeguards We employ system safeguards to warn patients of external factors that can impact system accuracy. These safeguards include underdose detection, test strip expiration warnings, damaged test strip detection, abnormal temperature warnings and low-meter battery warnings. Labeling We support standardizing product labeling with a simple, easy-to-use format. With the launch of the ACCU-CHEK Aviva Plus care kit, we have redesigned the labeling to be more user friendly. Quality Assurance We support development of an industry standard for complaint handling, medical device reporting (MDR) of product malfunctions and consistent manufacturing processes. Patient Support and Education Our call center is available 24/7/365 and offers patient support in over 150 languages. 14

References 1. International Organization for Standardization (ISO) 15197: 2003. Terms and definitions. Section 3.1. 2. International Organization for Standardization (ISO) 15197: 2003. Minimum acceptable system accuracy. Section 7.4.1. 3. Brotman S. FDA public hearing on clinical accuracy requirements for point of care blood glucose meters. AdvaMed PowerPoint presentation. 2010. 4. Duxbury M. An enzymatic clinical chemistry laboratory experiment incorporating an introduction to mathematical method comparison techniques. Biochemistry and Molecular Biology Education. 2004;32:246 249. Available at: http://onlinelibrary.wiley.com/doi/10.1002/ bmb.2004.494032040366/pdf. Accessed October 20, 2011. 5. International Organization for Standardization (ISO) 15197: 2003. System accuracy evaluation. Section 7.3.1. 6. Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23:1143-1148. Available at: http://care.diabetesjournals.org/content/23/8/1143.full.pdf. Accessed October 20, 2011. 7. Manufacturer 510(k) product submission and internal Roche evaluation.

If you have any questions, please contact your local ACCU-CHEK representative. ACCU-CHEK and ACCU-CHEK AVIVA are trademarks of Roche. YSI 2300 STAT Plus is a trademark of YSI Life Sciences. All other product names and trademarks are the property of their respective owners. 2011 Roche. 316-49670-1011