Accuracy Test Omnitest 3 Blood Glucose Monitoring System. B. Braun Diabetes Care
|
|
- Andrew Dorsey
- 8 years ago
- Views:
Transcription
1 Accuracy Test Omnitest Blood Glucose Monitoring System B. Braun Diabetes Care
2 Accuracy Test Omnitest blood glucose monitoring system according to ISO 97 The accuracy study of Omnitest blood glucose monitoring system was assessed by comparing patients blood glucose results obtained with Omnitest with those obtained using the YSI 2 auto analyzer, a standard laboratory instrument. Glucose levels were measured in patients from three different hospitals. Test information A) Test date: ~ E) Standard/Guidance documents referenced: B) Test meter serial number: C) Test strip lot numbers: GAA2RDMC49 ~ GAA2RDMC4 ISO/DIS 97:2 In Vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for GMJ24, GMJ2, GMJ26 self-testing in managing diabetes mellitus (during clinical trial) D) Sample numbers: 6 x Omnitest meters 6 x Omnitest test strips (three lots) x YSI 2 auto analyzer ISO 97:2 In Vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (for data analysis) CLSI EP9-A2: 24 Method comparison and bias estimating using patient samples Acceptance criteria 9 % of the individual glucose results shall deviate max. ±.8 mmol/l from the results obtained by the hospital laboratory device (YSI 2) at glucose concentration. mmol/l and the deviation should be per maximum ± % at glucose concentration. mmol/l (according to ISO 97:2). Test results Sample distribution Glucose concentration mmol/l Percentage of sample Sample # Preparation of sample 2.77 % glycolyzed % unaltered % 2 unaltered % unaltered. 6.6 % unaltered % unaltered 22.2 % supplemented with glucose SUM % Table Distribution of glucose concentrations of samples for system accuracy evaluation 2
3 Lot # - - Test results 2 2 System accuracy plot-difference (mmol/l) - - Lot # Lot # Lot # Difference, mmol/l System System accuracy plot-difference (mmol/l) Lot # Lot # Glucose Glucose concentration, concentration, mmol/l mmol/l 2 2 ) System accuracy plot-difference (mmol/l) Difference, mmol/l - -difference (mmol/l) Lot # Lot # System accuracy plot-difference (mmol/l) - - System accuracy ( plot-difference Lot combination) (mmol/l) ( Lot combination) ( Lot combination) Glucose Glucose concentration, concentration, mmol/l mmol/l ) Figure -differences of the x 2 blood glucose samples with the Omnitest BGMS vs. YSI 2 at hospital ( using Lot combination) lots of test strips
4 Omnitest, mmol/l 2 2 Lot # y =,96x +,8 R² =, Omnitest, mmol/l 2 2 YSI 2, mmol/l Test results Omnitest, mmol/l 2 2 System accuracy System plot accuracy plot y =,96x +,8 y =,96x +,8 R² =,984 2 R² =,984 2 Omnitest, mmol/l Lot # Lot # Lot # YSI 2, mmol/l YSI 2, mmol/l Omnitest, mmol/l plot System accuracy System Lot accuracy #2 plot plot Lot # y =,962x +,2 y =,962x +,2 y =,96x R² =,982 +,26 2 R² =,982 R² =, YSI 2, mmol/l YSI 2, mmol/l YSI 2, mmol/l Omnitest Omnitest, mmol/l, mmol/l Lot # Omnitest, mmol/l 2 2 ot Omnitest, mmol/l, mmol/l System Lot accuracy System # accuracy plot plot Lot # y =,962x +,2 y =,96x +,26 y = R²,96x =,982 +,26 R² =, R² =, YSI 2, mmol/l YSI 2, mmol/l YSI 2, mmol/l Omnitest, mmol/l Omnitest, mmol/l System ( Lot combination) accuracy plot ( Lot Combination) ( Lot Combination) y =,99x +,9 y =,99x +,9 R² =, R² =, Omnitest, mmol/l YSI 2, mmol/l YSI 2, mmol/l Figure 2 Linear regression of the x 2 blood glucose samples with the Omnitest BGMS vs. YSI 2 at hospital using lots of test strips ot ( Lot Combination) Omnitest, mmol/l 2 2 y =,99x +,9 R² =, YSI 2, mmol/l 4
5 Data analysis Bias distribution analysis against YSI 2 Strip Lot Within ±.28 mmol/l Within ±.6 mmol/l Within ±.8 mmol/l Lot 46/62 (74.2 %) 8/62 (9. %) 62/62 (. %) Lot 2 4/62 (64. %) 9/62 (9.2 %) 62/62 (. %) Lot 6/62 (8. %) 8/62 (9. %) 62/62 (. %) Combined 22/86 (6.6 %) 7/86 (94. %) 86/86 (. %) Table 2 System accuracy results for Glucose concentration. mmol/l Strip Lot Within ± % Within ± % Within ± % Lot 77/8 (.8 %) 26/8 (9. %) 2/8 (9.7 %) Lot 2 7/8 (.7 %) 22/8 (88.4 %) 4/8 (97. %) Lot 68/8 (49. %) 8/8 (8. %) /8 (96.4 %) Combined 2/44 (.9 %) 66/44 (88.4 %) 99/44 (96.4 %) Table System accuracy results for Glucose concentrations. mmol/l Consensus error grid analysis against YSI 2: The evaluation of the distribution of the test results within the consensus error grid shows that 6 out of 6 measurements ( %) are within the zones A and B. Conclusion A good and direct correlation between a standard hospital laboratory device (YSI 2) and Omnitest were confirmed in the 6 blood samples ( patients) with a combined correlation coefficient R2 =.987. The results indicate that the use of the Omnitest blood glucose monitoring system generate similar results as the YSI 2 auto analyzer, a laboratory instrument used in hospitals to test for glucose concentration. The data shown prove that the results are within the accuracy standard of the ISO 97:2 thus within the acceptance criteria. References. ISO/DIS 97:2 In vitro diagnostic test systems Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus 2. ISO 97:2 In vitro diagnostic test systems Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. CLSI EP9-A2: 24 Method comparison and bias estimating using patient samples 4. Parkes J.L. et al. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood-glucose. Diabetes Care. 2, 2 (8) pp. 448
6 B. Braun Melsungen AG OPM Carl-Braun-Straße 422 Melsungen Deutschland Tel. ( 6 6) 7-99 Fax ( 6 6) Nr Stand: 4/24
Evaluation of Accuracy and User Performance of the TRUE METRIX Self-Monitoring Blood Glucose System *
Evaluation of Accuracy and User Performance of the TRUE METRIX Self-Monitoring Blood Glucose System * Summary Objectives: To demonstrate that the TRUE METRIX Self-Monitoring Blood Glucose System*, from
More informationFDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs)
FDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs) Barriers to Overcoming Interferences and Limitations Alan T. Cariski, MD, JD, and Mike Flis, AdvaMed BGM
More informationA comparison of blood glucose meters in Australia
Diabetes Research and Clinical Practice 71 (2006) 113 118 www.elsevier.com/locate/diabres A comparison of blood glucose meters in Australia Matthew Cohen *, Erin Boyle, Carol Delaney, Jonathan Shaw International
More informationA guidebook for people with diabetes
A guidebook for people with diabetes This booklet is designed to supplement, not replace, your doctor s advice. Please consult your doctor if you have any questions about what you read. You ll learn how
More informationBlood Glucose Monitoring: The Facts about Accuracy
Blood Glucose Monitoring: The Facts about Accuracy Summary The purpose of this document is to provide the facts about the accuracy of self-monitoring of blood glucose (SMBG) systems. Accuracy can be defined
More informationValidation of measurement procedures
Validation of measurement procedures R. Haeckel and I.Püntmann Zentralkrankenhaus Bremen The new ISO standard 15189 which has already been accepted by most nations will soon become the basis for accreditation
More informationSMF Awareness Seminar 2014
SMF Awareness Seminar 2014 Clinical Evaluation for In Vitro Diagnostic Medical Devices Dr Jiang Naxin Health Sciences Authority Medical Device Branch 1 In vitro diagnostic product means Definition of IVD
More informationUSING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY
USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY Breakout Session 3B Tuesday, May 1 8:30 10 am James Blackwood, MS, CLSI David D. Koch, PhD, FACB, DABCC, Pathology & Laboratory
More informationBlood Glucose Monitoring Test Systems for Prescription Point-of- Care Use Draft Guidance for Industry and Food and Drug Administration Staff
Blood Glucose Monitoring Test Systems for Prescription Point-of- Care Use Draft Guidance for Industry and Food and Drug Administration Staff GUIDANCE guidance. Submit written comments to the Division of
More informationSureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)
WHITE PAPER SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR) LifeScan developed the SureStep Pro Linearity Solutions to assist institutional customers in meeting regulatory
More informationSamsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT
Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT Alexander Belenky, PhD Director -Product Development Samsung - Nexus-Dx Edward Brennan, PhD
More informationSAMPLE. Effects of Different Sample Types on Glucose Measurements
1st Edition POCT06 Effects of Different Sample Types on Glucose Measurements This report provides information to assist the clinical and point-ofcare staff in result and measurement procedure comparisons
More informationUS Diabetic Devices Industry Research Report: KenResearch
US Diabetic Devices Industry Research Report: KenResearch by KenResearch - Monday, February 24, 2014 https://www.kenresearch.com/blog/2014/02/us-diabetic-devices-industry-research-report-kenresearch/ The
More informationMethod Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory
Method Validation/Verification CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory References Westgard J. O.: Basic Method Validation, Westgard Quality Corporation Sarewitz
More informationBasic Statistics and Data Analysis for Health Researchers from Foreign Countries
Basic Statistics and Data Analysis for Health Researchers from Foreign Countries Volkert Siersma siersma@sund.ku.dk The Research Unit for General Practice in Copenhagen Dias 1 Content Quantifying association
More informationCenter for Clinical Standards and Quality/Survey & Certification Group
DEPARTMENT OF HEALTH & HUMAN SERVICES Centers for Medicare & Medicaid Services 7500 Security Boulevard, Mail Stop C2-21-16 Baltimore, Maryland 21244-1850 Center for Clinical Standards and Quality/Survey
More informationUnivariate Regression
Univariate Regression Correlation and Regression The regression line summarizes the linear relationship between 2 variables Correlation coefficient, r, measures strength of relationship: the closer r is
More informationHow To Write A Guideline For Global Application From The Clinical And Laboratory Standards Institute
December 2008 Performance Metrics for Continuous Interstitial Glucose Monitoring; Approved Guideline This document provides consensus guidelines for health care professionals, in vitro diagnostic (IVD)
More information510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY
510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY A. 510(k) Number: k103555 B. Purpose for Submission: New submission C. Measurand: Platelet aggregation D. Type of Test: Platelet aggregometer
More informationYour diabetes: Understanding your blood glucose test results. Information for patients Diabetes Service. HbA1c. Large Print. What is the HbA1c test?
Your diabetes: Understanding your blood glucose test results This leaflet explains about the different ways your diabetes blood glucose control is measured. Knowing the level of glucose in your blood is
More informationAn important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and
An important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and CoaguChek systems Cardiovascular disease: the #1 killer in
More informationBLOOD GLUCOSE MONITORING SYSTEM USER GUIDE
BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE Thank you for choosing the Contour blood glucose monitoring system! We are proud to be your partner in helping you manage your diabetes. Our goal is to make this
More informationD-Facts. Vitamin D Competitive Evaluation
D-Facts Vitamin D Competitive Evaluation Abstract 101 patient samples collected across sites in Germany were used to compare the performance of the Siemens ADVIA Centaur Vitamin D Total (VitD), Abbott
More informationQuantifying measurement error from digital instruments
Quantifying measurement error from digital instruments W. BLAKE LAING AND SEAN BRYANT SOUTHERN ADVENTIST UNIVERSITY CHAT TANOOGA, TN What I m doing HELPING STUDENTS LEARN TO CONSTRUCT KNOWLEDGE First lab:
More informationContents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1
ISBN 1-56238-584-4 Volume 25 Number 27 ISSN 0273-3099 Interference Testing in Clinical Chemistry; Approved Guideline Second Edition Robert J. McEnroe, PhD Mary F. Burritt, PhD Donald M. Powers, PhD Douglas
More informationUnit 31 A Hypothesis Test about Correlation and Slope in a Simple Linear Regression
Unit 31 A Hypothesis Test about Correlation and Slope in a Simple Linear Regression Objectives: To perform a hypothesis test concerning the slope of a least squares line To recognize that testing for a
More informationUrinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren
Urinalysis Compliance Tools POCC Webinar January 19, 2011 Dr. Susan Selgren Learning Objectives Be able to review and improve upon a laboratory plan for compliance including: Competency Documentation Proficiency
More informationForecasting the first step in planning. Estimating the future demand for products and services and the necessary resources to produce these outputs
PRODUCTION PLANNING AND CONTROL CHAPTER 2: FORECASTING Forecasting the first step in planning. Estimating the future demand for products and services and the necessary resources to produce these outputs
More informationPerformance Variability of Seven Commonly Used Self-Monitoring of Blood Glucose Systems: Clinical Considerations for Patients and Providers
Journal of Diabetes Science and Technology Volume 7, Issue 1, January 2013 Diabetes Technology Society ORIGINAL ARTICLE Performance Variability of Seven Commonly Used Self-Monitoring of Blood Glucose Systems:
More informationReport. European Co-ordinated Post Market Surveillance Operation under COEN authority. Blood Glucose Meters
1 v 3 Report European Co-ordinated Post Market Surveillance Operation under COEN authority Blood Glucose Meters Afssaps: France Irish Medicines Board: Ireland MHRA: United Kingdom 2 Summary I - INTRODUCTION...
More informationB. Braun Space GlucoseControl (SGC)
B. Braun Space GlucoseControl (SGC) Quick Reference Guide Valid for software I9305_C Automated Infusion Systems Starting a new insulin therapy SpaceControl cannot be switched on and off by itself. It is
More information510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY
A. 510(k) Number: K092353 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY B. Purpose for Submission: This is a new 510k application for a new indication for the MONOLISA Anti-HAV IgM EIA
More informationHow To Test For Creatinine
Creatinine is measured amperometrically. Creatinine is hydrolyzed to creatine in a reaction catalyzed by the enzyme creatinine amidohydrolase. Creatine is then hydrolyzed to sarcosine in a reaction catalyzed
More informationBasic Lessons in Laboratory Quality Control
Bio-Rad Laboratories QC education Basic Lessons in Laboratory Quality Control QC Workbook Basic Lessons in Laboratory Quality Control Written by Greg Cooper, CLS, MHA Manager of Clinical Standards and
More informationThe importance of graphing the data: Anscombe s regression examples
The importance of graphing the data: Anscombe s regression examples Bruce Weaver Northern Health Research Conference Nipissing University, North Bay May 30-31, 2008 B. Weaver, NHRC 2008 1 The Objective
More informationEVALUATION OF AUTOMATIC CLASS III DESIGNATION FOR STUDIO on the Cloud Data Management Software DECISION SUMMARY
A. DEN Number: DEN140016 EVALUATION OF AUTOMATIC CLASS III DESIGNATION FOR STUDIO on the Cloud Data Management Software B. Purpose for Submission: DECISION SUMMARY De novo request for adjunct data management
More informationAnswer: C. The strength of a correlation does not change if units change by a linear transformation such as: Fahrenheit = 32 + (5/9) * Centigrade
Statistics Quiz Correlation and Regression -- ANSWERS 1. Temperature and air pollution are known to be correlated. We collect data from two laboratories, in Boston and Montreal. Boston makes their measurements
More informationDiabetes Monitoring Diary
Diabetes Monitoring Diary For those Counting Diabetes Service My targets: Before breakfast Before other meals Before bed... mmol/l... mmol/l... mmol/l Correcting high blood glucose levels: Information
More information11. Analysis of Case-control Studies Logistic Regression
Research methods II 113 11. Analysis of Case-control Studies Logistic Regression This chapter builds upon and further develops the concepts and strategies described in Ch.6 of Mother and Child Health:
More informationPoint Biserial Correlation Tests
Chapter 807 Point Biserial Correlation Tests Introduction The point biserial correlation coefficient (ρ in this chapter) is the product-moment correlation calculated between a continuous random variable
More information4/3/2014 STATISTICAL APPLICATIONS IN MARKET RESEARCH. Introductions. Tiffany Bonus, MS Chris Claeys, MS
STATISTICAL APPLICATIONS IN MARKET RESEARCH Introductions Tiffany Bonus, MS Chris Claeys, MS 1 Agenda What is Market Research? Job Responsibilities Important Skills Research Topics Statistical Applications
More informationInnovations in Diabetes. Angela Blair Channel Manager RN Credentialled Diabetes Educator
Innovations in Diabetes Angela Blair Channel Manager RN Credentialled Diabetes Educator Innovations Time - $$$ Innovations & Technology Blood Testing Insulin delivery devices Insulin pumps Pills & Potions
More informationBLOOD GLUCOSE MONITORING SYSTEM USER GUIDE
BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE Thank you for choosing the CONTOUR blood glucose monitoring system! We are proud to be your partner in helping you manage your diabetes. Our goal is to make this
More informationPOCT in diagnosing and monitoring of Diabetes Mellitus. 13th EFLM Continuous Postgraduate Course, Sverre Sandberg, Noklus / EFLM
POCT in diagnosing and monitoring of Diabetes Mellitus - 13th EFLM Continuous Postgraduate Course, Sverre Sandberg, Noklus / EFLM The most important constituents - Glucose monitoring and diagnosing - U-albumin
More informationSelf-Monitoring of Blood Glucose in Noninsulin- Treated Diabetes
Summary and Conclusions Self-Monitoring of Blood Glucose in Noninsulin- Treated Diabetes A Systematic Review Swedish Council on Health Technology Assessment SBU Board of Directors and Scientific Advisory
More informationLinear Regression. Chapter 5. Prediction via Regression Line Number of new birds and Percent returning. Least Squares
Linear Regression Chapter 5 Regression Objective: To quantify the linear relationship between an explanatory variable (x) and response variable (y). We can then predict the average response for all subjects
More informationAssay Migration Studies for In Vitro Diagnostic Devices Guidance for Industry and FDA Staff
Assay Migration Studies for In Vitro Diagnostic Devices Guidance for Industry and FDA Staff Document issued on: April 25, 2013 The draft of this document was issued on January 5, 2009. For questions regarding
More informationCHAPTER 13 SIMPLE LINEAR REGRESSION. Opening Example. Simple Regression. Linear Regression
Opening Example CHAPTER 13 SIMPLE LINEAR REGREION SIMPLE LINEAR REGREION! Simple Regression! Linear Regression Simple Regression Definition A regression model is a mathematical equation that descries the
More informationTHE COST OF COLLEGE EDUCATION PROJECT PACKET
THE COST OF COLLEGE EDUCATION PROJECT PACKET Introduction We live in a society where a college education is considered the norm and not the exception. While everyone is expected to attend a college or
More informationWireless Blood Glucose Monitoring System
Wireless Blood Glucose Monitoring System User Guide For use with CONTOUR LINK Blood Glucose Meter, Ascensia MICROFILL Test Strips, and Compatible Medtronic Diabetes Devices Thank you for choosing the CONTOUR
More information2011 EBM-hyperglycemia
嗎 2011 EBM-hyperglycemia 陳 莉 瑋 醫 師 一 定 要 打 打 bolus insulin? 用 FinePrint 列 印 - 可 在 www.ahasoft.com.tw/fineprint 訂 購 Question 1 Is bolus insulin necessary in DKA? P:DKA adult patient I:initial bolus insulin+insulin
More informationPractice Advisory Blood Glucose Meter Accuracy Issued September 16, 2013
Practice Advisory Blood Glucose Meter Accuracy Issued September 16, 2013 For the person with diabetes, blood glucose monitoring provides immediate feedback on the effects of daily activities such as taking
More informationAUDIT PROTOCOL FOR THE VICTORIAN WATER QUALITY MONITORING NETWORK
AUDIT PROTOCOL FOR THE VICTORIAN WATER QUALITY MONITORING NETWORK ENVIRONMENT PROTECTION AUTHORITY June 1999 AUDIT PROTOCOL FOR THE VICTORIAN WATER QUALITY MONITORING NETWORK, June 1999 David Robinson
More informationDimensionality Reduction: Principal Components Analysis
Dimensionality Reduction: Principal Components Analysis In data mining one often encounters situations where there are a large number of variables in the database. In such situations it is very likely
More informationValidation and Calibration. Definitions and Terminology
Validation and Calibration Definitions and Terminology ACCEPTANCE CRITERIA: The specifications and acceptance/rejection criteria, such as acceptable quality level and unacceptable quality level, with an
More information1. What is the critical value for this 95% confidence interval? CV = z.025 = invnorm(0.025) = 1.96
1 Final Review 2 Review 2.1 CI 1-propZint Scenario 1 A TV manufacturer claims in its warranty brochure that in the past not more than 10 percent of its TV sets needed any repair during the first two years
More informationIndex-Velocity Rating Development (Calibration) for H-ADCP Real-Time Discharge Monitoring in Open Channels
Index-Velocity Rating Development (Calibration) for H-ADCP Real-Time Discharge Monitoring in Open Channels Hening Huang Teledyne RD Instruments, Inc., 14020 Stowe Drive, Poway, CA. 92064, USA (Tel: 858-842-2600,
More informationThe Effect of Temperature on Conductivity Measurement
The Effect of on Measurement Authors: John J. Barron & Colin Ashton Technical Services Department, Reagecon Diagnostics Ltd, Shannon Free Zone, County Clare, Ireland Abstract The conductivity of all solutions
More informationA telemedical therapy-management-system with rule-based active patient-feedback
A telemedical therapy-management-system with rule-based active patient-feedback Austrian Research Centers GmbH ARC ehealth systems Graz - Hall in Tirol - Vienna Matthias Pinsker, Peter Kastner, Günter
More information430 Statistics and Financial Mathematics for Business
Prescription: 430 Statistics and Financial Mathematics for Business Elective prescription Level 4 Credit 20 Version 2 Aim Students will be able to summarise, analyse, interpret and present data, make predictions
More informationExperiment #1, Analyze Data using Excel, Calculator and Graphs.
Physics 182 - Fall 2014 - Experiment #1 1 Experiment #1, Analyze Data using Excel, Calculator and Graphs. 1 Purpose (5 Points, Including Title. Points apply to your lab report.) Before we start measuring
More informationTesting for a Reason:
Testing for a Reason: New Information About Type 2 Diabetes and Testing Your Blood Sugar A Guide for You Blood Sugar Testing Testing blood sugar at home using test strips and a meter is common practice
More informationCONTROL SYSTEM FOR INSULIN PUMPS IN THE MELLITUS DIABETES TREATMENTS
CONTROL SYSTEM FOR INSULIN PUMPS IN THE MELLITUS DIABETES TREATMENTS 1. INTRODUCTION The mellitus diabetes is a chronic disease that develops a great risk of progression of diabetes complications: diabetes
More informationNova Scotia Guidelines for Acute Coronary Syndromes (Updating the 2008 Diabetes sections of the Guidelines)
Cardiovascular Health Nova Scotia Guideline Update Nova Scotia Guidelines for Acute Coronary Syndromes (Updating the 2008 Diabetes sections of the Guidelines) Authors: Dr. M. Love, Kathy Harrigan Reviewers:
More informationtable to see that the probability is 0.8413. (b) What is the probability that x is between 16 and 60? The z-scores for 16 and 60 are: 60 38 = 1.
Review Problems for Exam 3 Math 1040 1 1. Find the probability that a standard normal random variable is less than 2.37. Looking up 2.37 on the normal table, we see that the probability is 0.9911. 2. Find
More informationApplying Statistics Recommended by Regulatory Documents
Applying Statistics Recommended by Regulatory Documents Steven Walfish President, Statistical Outsourcing Services steven@statisticaloutsourcingservices.com 301-325 325-31293129 About the Speaker Mr. Steven
More informationLab: Graphing Activities TOTTEN
Name: Class: Date Completed: Lab Minutes: Lab: Graphing Activities TOTTEN SCIENCE Introduction Graphing is used by scientists to display the data that is collected during a controlled experiment. A line
More informationQuality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)
Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs) James H. Nichols, PhD, DABCC, FACB Professor of Pathology, Microbiology, and Immunology Medical Director, Clinical
More informationADMINISTRATIVE MANUAL Policy and Procedure
ADMINISTRATIVE MANUAL Policy and Procedure TITLE: Point of Care Testing NUMBER: CH 30-111 (Laboratory Diagnostic Bedside Testing) Effective Date: January 2014 Page 1 of 6 Applies To: Holders of Administrative
More informationWater scarcity as an indicator of poverty in the world
Water scarcity as an indicator of poverty in the world Maëlle LIMOUZIN CE 397 Statistics in Water Resources Dr David MAIDMENT University of Texas at Austin Term Project Spring 29 Introduction Freshwater
More informationWind resources map of Spain at mesoscale. Methodology and validation
Wind resources map of Spain at mesoscale. Methodology and validation Martín Gastón Edurne Pascal Laura Frías Ignacio Martí Uxue Irigoyen Elena Cantero Sergio Lozano Yolanda Loureiro e-mail:mgaston@cener.com
More informationSymmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE www.tosohbioscience.us
Symmetry in Diagnostics HPLC ANALYZER Gold Standard Accuracy by Ion-Exchange HbA1c TOSOH BIOSCIENCE www.tosohbioscience.us HPLC ANALYZER HbA1c analysis in 1.6 minutes Direct determination of stable HbA1c
More informationApplied Software Project Management
Applied Software Project Management Estimation http://www.stellman-greene.com 1 What is estimation? The project manager must set expectations about the time required to complete the software among the
More informationGuidance for Industry and FDA Staff
Guidance for Industry and FDA Staff Review Criteria for Assessment of C-Reactive Protein (CRP), High Sensitivity C-Reactive Protein (hscrp) and Cardiac C-Reactive Protein (ccrp) Assays Document issued
More informationQuantitative Imaging In Clinical Trials Using PET/CT: Update
Quantitative Imaging In Clinical Trials Using PET/CT: Update Paul Kinahan, Robert Doot Imaging Research Laboratory Department of Radiology University of Washington, Seattle, WA Supported by RSNA Quantitative
More informationVirtual Met Mast verification report:
Virtual Met Mast verification report: June 2013 1 Authors: Alasdair Skea Karen Walter Dr Clive Wilson Leo Hume-Wright 2 Table of contents Executive summary... 4 1. Introduction... 6 2. Verification process...
More informationReport reference guide. mmol/l. One. solution EMR. No fuss
Report reference guide mmol/l One solution No fuss 0000000000 00 0 0000 00 0 0 0 0 0 0 000000000 0 0 00 0 0 0 00 00 0 0 0 0 0 0 00 00000000000000000000 00 EMR About. Plug Transmitter into your outlet is
More informationRegression Analysis: A Complete Example
Regression Analysis: A Complete Example This section works out an example that includes all the topics we have discussed so far in this chapter. A complete example of regression analysis. PhotoDisc, Inc./Getty
More informationNot Your Dad s Magic Eight Ball
Not Your Dad s Magic Eight Ball Prepared for the NCSL Fiscal Analysts Seminar, October 21, 2014 Jim Landers, Office of Fiscal and Management Analysis, Indiana Legislative Services Agency Actual Forecast
More informationYour diabetes: Understanding your blood glucose test results. Information for patients Diabetes Service. HbA1c. Large Print. What is the HbA1c test?
Your diabetes: Understanding your blood glucose test results This leaflet explains the different ways your diabetes blood glucose control is measured. Knowing the level of glucose in your blood is important
More informationChapter 7: Simple linear regression Learning Objectives
Chapter 7: Simple linear regression Learning Objectives Reading: Section 7.1 of OpenIntro Statistics Video: Correlation vs. causation, YouTube (2:19) Video: Intro to Linear Regression, YouTube (5:18) -
More informationWhat Does Having a FDA Cleared Pregnancy Test Mean?
What Does Having a FDA Cleared Pregnancy Test Mean? Clinical Trials Transformation Initiative (CTTI) July 15-16, 2013 Denise N. Johnson-Lyles, Ph.D. Toxicology Branch Chief Division of Chemistry and Toxicology
More information2. Filling Data Gaps, Data validation & Descriptive Statistics
2. Filling Data Gaps, Data validation & Descriptive Statistics Dr. Prasad Modak Background Data collected from field may suffer from these problems Data may contain gaps ( = no readings during this period)
More informationSAMPLE. Accuracy in Patient and Sample Identification; Approved Guideline. This guideline describes the essential elements of systems and processes
March 2010 Accuracy in Patient and Sample Identification; Approved Guideline This guideline describes the essential elements of systems and processes required to ensure accurate patient identification.
More informationCopyright 2010-2012 PEOPLECERT Int. Ltd and IASSC
PEOPLECERT - Personnel Certification Body 3 Korai st., 105 64 Athens, Greece, Tel.: +30 210 372 9100, Fax: +30 210 372 9101, e-mail: info@peoplecert.org, www.peoplecert.org Copyright 2010-2012 PEOPLECERT
More informationFinancial Risk Management Exam Sample Questions/Answers
Financial Risk Management Exam Sample Questions/Answers Prepared by Daniel HERLEMONT 1 2 3 4 5 6 Chapter 3 Fundamentals of Statistics FRM-99, Question 4 Random walk assumes that returns from one time period
More informationThe Shifting Sands of Medical Software Regulation
The Shifting Sands of Medical Software Regulation Suzanne O Shea Ralph Hall September 10, 2014 What Software is Regulated by FDA? FDA regulates medical devices. FDA regulates software that meets the definition
More informationPoint-of-care (POC) versus central laboratory instrumentation for monitoring oral anticoagulation
Point-of-care (POC) versus central laboratory instrumentation for monitoring oral anticoagulation David M Dorfman a, Ellen M Goonan a, M Kay Boutilier a, Petr Jarolim a, Milenko Tanasijevic a and Samuel
More informationNCSS Statistical Software Principal Components Regression. In ordinary least squares, the regression coefficients are estimated using the formula ( )
Chapter 340 Principal Components Regression Introduction is a technique for analyzing multiple regression data that suffer from multicollinearity. When multicollinearity occurs, least squares estimates
More informationHypoglycemia (Technician-Paramedic) Protocol revised October 2008
Hypoglycemia (Technician-Paramedic) Protocol revised October 2008 Preamble Prolonged hypoglycemia may result in serious neurologic complications and death. Glucose and glucagon can be administered to correct
More informationAP Physics 1 and 2 Lab Investigations
AP Physics 1 and 2 Lab Investigations Student Guide to Data Analysis New York, NY. College Board, Advanced Placement, Advanced Placement Program, AP, AP Central, and the acorn logo are registered trademarks
More information510(K) SUMMARY FEB - 12008. Submitter: Name of the device: * Common Name: Clinical Chemistry Analyzer (with optional ISE Module) Attachment #2
Attachment #2 510 (k) Summary 510(K) SUMMARY FEB - 12008 This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92.
More informationGuidance for Industry
Guidance for Industry Q2B Validation of Analytical Procedures: Methodology November 1996 ICH Guidance for Industry Q2B Validation of Analytical Procedures: Methodology Additional copies are available from:
More informationTheory at a Glance (For IES, GATE, PSU)
1. Forecasting Theory at a Glance (For IES, GATE, PSU) Forecasting means estimation of type, quantity and quality of future works e.g. sales etc. It is a calculated economic analysis. 1. Basic elements
More information3-Step Competency Prioritization Sequence
3-Step Competency Prioritization Sequence The Core Competencies for Public Health Professionals (Core Competencies), a consensus set of competencies developed by the Council on Linkages Between Academia
More informationList of Examples. Examples 319
Examples 319 List of Examples DiMaggio and Mantle. 6 Weed seeds. 6, 23, 37, 38 Vole reproduction. 7, 24, 37 Wooly bear caterpillar cocoons. 7 Homophone confusion and Alzheimer s disease. 8 Gear tooth strength.
More informationCorrelation key concepts:
CORRELATION Correlation key concepts: Types of correlation Methods of studying correlation a) Scatter diagram b) Karl pearson s coefficient of correlation c) Spearman s Rank correlation coefficient d)
More informationExamining a Fitted Logistic Model
STAT 536 Lecture 16 1 Examining a Fitted Logistic Model Deviance Test for Lack of Fit The data below describes the male birth fraction male births/total births over the years 1931 to 1990. A simple logistic
More informationBLOOD KETONE TESTING
BLOOD KETONE TESTING Information Leaflet Your Health. Our Priority. Page 2 of 5 What are ketones? Maintaining good blood glucose control is important. When there is not enough insulin in the body, or when
More information