Industrial Generator Set Accessories



Similar documents
Industrial Generator Set Accessories

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Dual wall sub-base fuel tanks-ibc Certified kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2)

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Magnum Mobile Generator MMG55 Specifications

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Morrison Bros. Co. General Product Specifications

The kva RAnge

Midwest Industrial Tanks

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

ECOCIAT. Domestic hot water heat recovery unit

Fire Pump Plan Review March 2010

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

DIESEL GENERATOR SETS

Element D Services Plumbing

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Utility Distribution Systems

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

NFPA31FuelOilPiping 1 Revised

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

PAINT BOOTH LIGHTING

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Element D Services Heating, Ventilating, and Air Conditioning

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

2010 Residential Water Heater Replacement Check List

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Sample - No Commercial Use

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Centro-Matic Automatic Lubrication Systems System Controls

Advantium 2 Plus Alarm

Explosion-Proof Electric Unit Heaters

Frequently Asked Questions Generators

Diesel Engine Driven Generators Page 1 of 6

The following definitions apply with regard to requirements specified in this document:

DRYER VENTING SPECIFICATIONS DRYER SAFETY

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Cooktop Low-Profile Ventilation Hoods

Commercial Gas Water Heaters

COMMISSIONING OF HVAC SYSTEMS

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

HEAVY DUTY STORAGE GAS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

OPERATING INSTRUCTIONS

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

CADB and CADT-D / DI / DC Series

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

ASX7-4-IOM-7 J

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

SECTION GENERAL PROVISIONS FOR HVAC WORK

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

SECTION MORTUARY REFRIGERATORS

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Medical Air Systems: Scroll

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Installation Manual CLIFC Fan & Coil Variable Speed

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

ASCO SERIES 185 Power Transfer Switches

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Cooling Capacity CFM in. w.c. (125 Pa)

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Air Conditioning Sign-Off Sheet

NAVIEN AMERICA INC FITCH AVENUE

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Section 8 Storage Tanks & Equipment

COOLING SYSTEM Section Page

Name Of Occupancy Date. Yes No Describe

Transcription:

Industrial Generator Set Accessories Aluminum and Steel and Subbase Fuel Tank Package All Generator Set,, and Fuel Tank Options are UL 2200 Certified. Available Approvals and Listings - UL 2200 Listing - CSA Approval - IBC Seismic Certification - California OSHPD Approval - cul Listing (fuel tanks only) Applicable to the following: 350-500REOZJ Weather Standard Features D Internal silencer, flexible exhaust connector and rain cap. D Mounts to generator set skid. Aluminum or steel construction with hinged and removable doors. D Fade-, scratch-, and corrosion-resistant Kohlerr Power Armort automotive-grade textured finish. D has six large access doors which allow for easy maintenance. D Lockable, flush-mounted door latches. D Air inlet louvers reduce rain entry. Sound s Standard Features D Includes all of the weather enclosure features with the addition of acoustic insulation material. D Internal vertical discharge plenum directs air up to reduce noise. D Acoustic insulation that meets UL 94 HF1 flammability classification. D Sound enclosure offering Level 1 or Level 2 sound reduction using acoustic insulation. See specifications at the back of this document for sound pressure levels. Subbase Fuel Tank Features D The fuel tank has a Power Armor Plust textured epoxy-based rubberized coating. D The above-ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). D Both the inner and outer tanks have emergency relief vents. D Flexible fuel lines are provided with subbase fuel tank selection. Stainless steel fuel lines are an available option. D The secondary containment tank s construction protects against fuel leaks or ruptures. The inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel if the inner tank leaks or ruptures. D State tanks with varying capacities are an available option. and Subbase Fuel Tank Combinations There are three enclosure configurations available with the subbase fuel tanks. Weather with Internal Silencer Sound Level 1 with Internal Silencer Sound Level 2 with Internal Dual Silencers (connected in series) G6-117 3/16g Page 1

Weather Fade, scratch, and corrosion resistant power-baked finish Radiator fill panel enables easy service access Punched air outlet grid. Radiator ducted to enclosure air outlet prevents air recirculation within the enclosure Silencer includes tailpipe and rain cap. Fixed air inlet louvers sized for maximum radiator cooling air flow Door hold backs provide positive door positioning during wind gusts Recessed and lockable door handles minimize potential damage Rubber sealed access doors prevent water infiltration and minimize noise Hinged and removable doors for ease of servicing ships assembled on the generator set skid. Note: Sample model shown, other models are similar. ADV-7991A- Weather Features D Heavy-duty formed panels, solid construction. Preassembled package offering corrosion resistant, dent resilient structure mounting directly to the generator set skid. Available in 3 mm (0.125 in.) aluminum or 14 gauge steel. D Power Armort automotive-grade finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention. D Internal exhaust silencer. Offers maximum component life, operator safety, and includes rain shield and cap. NOTE: Installing an additional length of exhaust tail pipe may increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. D Interchangeable modular panel construction allows design flexibility. D Bolted panels facilitate service, future modification upgrades, or field replacement. D Cooling/combustion air intake. Weather protective designs using fixed air inlet louvers. Sized for maximum cooling airflow. D Cooling air discharge. Weather protective design featuring vertical air discharge. Exhausts air through a punched air outlet grille. D Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. G6-117 3/16g Page 2

Level 1 and Level 2 Sound Fade, scratch, and corrosion resistant powder-baked finish Acoustic insulation meetingul94hf1 flammability classification Radiator fill panel enables easy service access Radiator ducted to enclosure air outlet prevents air recirculation within the enclosure Enclosed insulated exhaust silencer for improved safety and noise reduction. Fixed air inlet louvers sized for maximum radiator cooling Door hold backs provide positive door positioning during wind gusts Recessed and lockable door handles minimize potential damage Rubber sealed access doors prevent water infiltration and minimize noise Hinged and removable doors for ease of servicing Acoustic insulation repels moisture absorption ships assembled on the generator set skid. Note: Sample model shown, other models are similar. ADV-7990A- Level 1 and Level 2 Sound Features D Heavy-duty formed panels, solid construction. Pre-assembled package offering corrosion resistant, dent resilient structure mounting directly to the generator set skid. Available in 3 mm (0.125 in.) aluminum or 14 gauge steel. D Power Armort automotive-grade finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention. D Internal exhaust silencer offering maximum component life and operator safety. NOTE: Installing an additional length of exhaust tail pipe may increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. D Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. D Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. D Bolted panels facilitate service, future modification upgrades, or field replacement. D Cooling/combustion air intake. Weather protective designs using fixed air inlet louvers. Sized for maximum cooling airflow. D Cooling air discharge. Attenuated models offering an internal vertical discharge scoop that redirects cooling air up and above the enclosure to reduce noise. Level 1 Sound Features D Attenuated design using a silencer and acoustic insulation UL 94 HF1 listed for flame resistance. Level 2 Sound Features D Attenuated design using dual silencers connected in series and acoustic insulation UL 94 HF1 listed for flame resistance. G6-117 3/16g Page 3

Weather and Sound Options Fixed air intake louver (standard) Fixed air intake louver (left and right side) (standard) DC lights, qty. 2 Incandescent lights, qty. 2 Rain cap Discharge damper (mounted inside discharge plenum) Controller viewing window 3-way switch with GFCI (left side) Battery charger (left side) Distribution panel External emergency stop switch Timer for DC lights Note: Sample model shown, other models are similar. ADV-7990C- Material - Aluminum - Steel Silencer Options - Internal Silencer, weather enclosure - Internal Silencer, sound enclosure, level 1 - Internal Silencer, sound enclosure, level 2 Basic Electrical Package (BEP) - Distribution Panel/Load Center. Prewired AC power distribution of all factory-installed features including two GFCI-protected internal 120-volt service receptacles, two AC incandescent lights, and commercial grade wall switch. The single-phase load center powered by building source power and protected by a main circuit breaker, rated for 100 amps with capacity and circuit positions for future expansion. AC power distribution installed in accordance with NEC and all wiring within EMT thin wall conduit. Incandescent AC lights located within UL-listed fixtures designed for wet locations. DC Light Package - DC Light Package (DLP). Prewired qty. 2, internal DC light package offering an economical alternative light source within the enclosure, as a complement to the BEP or a source of light when AC power is not available. Battery drain limited with fuse protection and controlled through a 0--60 minute, spring-wound, no-hold timer. Miscellaneous Options Controller Viewing Window. Control panel viewing window. - Aluminum construction - Steel construction - Skid Extensions. Steel construction (for aluminum or steel enclosures) - Gravity Discharge. Aluminum construction (for aluminum or steel enclosures) - Battery Charger, Mounted. Mounting and prewiring of DC output and AC input when optional BEP is selected. Battery charger located inside the enclosure and accessible through an access door. - Battery Charger with Alarms. Mounted and wired. Block Heater Wiring. Prewiring of AC input when optional BEP is selected. - Heater available in single phase 90--120 VAC - Heater available in single phase 208--240 VAC - Remote Emergency Stop Switch. Externally mounted, recessed emergency stop switch. G6-117 3/16g Page 4

Subbase Fuel Tank Removable end channel Electrical stub-up area open to bottom Fuel leak detection switch Emergency outer tank relief vent Removable engine supply dip tube Removable fuel return dip tube Fuel level gauge Emergency inner tank relief vent Basin drain Normal vent Fuel fill with lockable cap Note: Sample standard tank model shown, other tank models are similar. Standard Subbase Fuel Tank Features D Extended operation. Optional tank capacities for multiple hour requirements. D Power Armor Plust textured epoxy-based rubberized coating that creates an ultra-thick barrier between the tank and harsh environmental conditions like humidity, saltwater, and extreme temperatures, and provides advanced corrosion and abrasion protection. D UL listed. Secondary containment generator set base tank meeting UL 142 requirements. D NFPA compliant. Designed to comply with the installation standards of NFPA 30 and NFPA 37. D Integral external lift lugs. Enables crane with spreader-bar lifting of the complete package (empty tank, mounted generator set, and enclosure) to ensure safety. D Emergency pressure relief vents. Vents ensure adequate venting of inner and outer tank under extreme pressure and/or emergency conditions. D Normal vent with cap. Vent is raised above lockable fuel fill. D Fuel level sender with fuel level and low and high fuel warning annunciated through the generator set controller. D Leak detection switch. Annunciates a contained primary tank fuel leak condition at generator set control. D Electrical stub-up area. State Subbase Fuel Tank Options Bottom Clearance/Coating - I-beams, provides 106 mm (4.2 in.) of ground clearance Fuel in Basin Options - Fuel in basin switch, Florida Dept. of Environmental Protection (FDEP) File No. EQ-682 approved Fuel Fill Options - Fill pipe extension to within 152 mm (6 in.) of bottom of fuel tank - 18.9 L (5 gallon) spill containment with 95% shutoff - 18.9 L (5 gallon) spill containment ADV-8045A- - 18.9 L (5 gallon) spill containment fill to within 152 mm (6 in.) of bottom of fuel tank - 28.4 L (7.5 gallon) spill containment, Florida Dept. of Environmental Protection (FDEP) File No. EQ-345 approved - 28.4 L (7.5 gallon) spill containment with 95% shutoff, Florida Dept. of Environmental Protection (FDEP) File No. EQ-345/EQ-257 approved Fuel Supply Options - Fire safety valve (installed on fuel supply line) - Ball valve (installed on fuel supply line) High Fuel Level Switch - High fuel level switch, Florida Dept. of Environmental Protection (FDEP) File No. EQ-682 approved - Three-alarm fuel tank panel - Three-alarm fuel tank panel, Florida Dept. of Environmental Protection (FDEP) File No. EQ-682 approved Normal Vent Options - 3.7 m (12 ft.) above grade (without spill containment) - 3.7 m (12 ft.) above grade (with spill containment) Tank Marking Options - Decal, Combustible Liquids -- Keep Fire Away (qty. 2) - Decal, NFPA 704 identification (qty. 2) - Decal, tank number and safe fuel fill height (qty. 2) - Decal, tank number and safe fuel fill height, NFPA 704 identification Fluid Containment Option - 100% engine fluid containment Freestanding Stairs - Stairs only - Stairs with platform - Stairs with catwalk G6-117 3/16g Page 5

Fuel Tank Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz with Full Load 350REOZJ Max. Dimensions, mm (in.) Max. Weight, kg (lb.) * Fuel Tank Height, mm (in.) Length Width Height With Steel With Aluminum Weather and Standard Subbase Fuel Tank 2423 (95) 5077 (11193) 4524 (9974) 0 (0) 2804 (110) 6147 (13635) 5594 (12416) 381 (15) 2905 (767) 24 5030 (198) 3083 (121) 6450 (14221) 5897 (13002) 660 (26) 6697 (14764) 6144 (13545) 4975 (1314) 48 5627 (222) 6904 (15222) 6351 (14003) Weather and State Subbase Fuel Tank 2804 (110) 6303 (13896) 5750 (12677) 381 (15) 2930 (774) 24 3007 (118) 6579 (14504) 6026 (13285) 584 (23) 3083 (121) 7103 (15659) 6550 (14440) 660 (26) 5046 (1333) 48 3134 (123) 7187 (15845) 6634 (14626) 711 (28) 10009 (2644) 72 6731 (265) 2591 (102) 3499 (138) 8576 (18906) 8023 (17687) Sound (Level 1) and Standard Subbase Fuel Tank 2423 (95) 5113 (11273) 4561 (10054) 0 (0) 2804 (110) 6183 (13715) 5631 (12496) 381 (15) 2905 (767) 24 5030 (198) 3083 (121) 6486 (14301) 5934 (13082) 660 (26) 6733 (14844) 6181 (13625) 4975 (1314) 48 5627 (222) 6940 (15302) 6388 (14083) Sound (Level 1) and State Subbase Fuel Tank 2804 (110) 6339 (13976) 5787 (12757) 381 (15) 2930 (774) 24 3007 (118) 6615 (14584) 6063 (13365) 584 (23) 3083 (121) 7139 (15739) 6587 (14520) 660 (26) 5046 (1333) 48 3134 (123) 7223 (155) 6671 (14706) 711 (28) 10009 (2644) 72 6731 (265) 2591 (102) 3499 (138) 8612 (18986) 8060 (17767) Sound (Level 2) and Standard Subbase Fuel Tank No Tank 0 5029 (198) 2423 (95) 5227 (11523) 4669 (10294) 0 (0) 2804 (110) 6297 (13965) 5739 (12736) 381 (15) 2905 (767) 24 5030 (198) 3083 (121) 6600 (14551) 6042 (13322) 660 (26) 6847 (15094) 6289 (13865) 4975 (1314) 48 5627 (222) 7054 (15552) 6496 (14323) Sound (Level 2) and State Subbase Fuel Tank 2804 (110) 6453 (14226) 5895 (12997) 381 (15) 2930 (774) 24 3007 (118) 6729 (14834) 6171 (13605) 584 (23) 3083 (121) 7253 (15989) 6695 (14760) 660 (26) 5046 (1333) 48 3134 (123) 7337 (16175) 6779 (14946) 711 (28) 10009 (2644) 72 6731 (265) 2591 (102) 3499 (138) 8726 (136) 8168 (18007) Sound Pressure Levels, db(a) [ 81 81 74 74 Note: Data in table is for reference only, refer to the respective ADV drawings for details. * Max. weight includes the generator set (wet) with largest alternator option, enclosure, silencer, and tank (no fuel). [ Log average sound pressure level of 8 measured positions around the perimeter of the unit at a distance of 7 m (23 ft). Refer to TIB-114 for details. G6-117 3/16g Page 6

Fuel Tank Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz with Full Load 400REOZJ Max. Dimensions, mm (in.) Max. Weight, kg (lb.) * Fuel Tank Height, mm (in.) Length Width Height With Steel With Aluminum Weather and Standard Subbase Fuel Tank 2423 (95) 5077 (11193) 4524 (9974) 0 (0) 2804 (110) 6147 (13635) 5594 (12416) 381 (15) 2905 (767) 24 5030 (198) 3083 (121) 6450 (14221) 5897 (13002) 660 (26) 6697 (14764) 6144 (13545) 5767 (1523) 48 6237 (246) 7081 (15612) 6528 (14393) Weather and State Subbase Fuel Tank 2804 (110) 6303 (13896) 5750 (12677) 381 (15) 2930 (774) 24 3007 (118) 6579 (14504) 6026 (13285) 584 (23) 3083 (121) 7103 (15659) 6550 (14440) 660 (26) 5767 (1523) 48 3236 (127) 7303 (16104) 6750 (14885) 813 (32) 10009 (2644) 72 6731 (265) 2591 (102) 3499 (138) 8576 (18906) 8023 (17687) Sound (Level 1) and Standard Subbase Fuel Tank 2423 (95) 5113 (11273) 4561 (10054) 0 (0) 2804 (110) 6183 (13715) 5631 (12496) 381 (15) 2905 (767) 24 5030 (198) 3083 (121) 6486 (14301) 5934 (13082) 660 (26) 6733 (14844) 6181 (13625) 5767 (1523) 48 6237 (246) 7117 (156) 6565 (14473) Sound (Level 1) and State Subbase Fuel Tank 2804 (110) 6339 (13976) 5787 (12757) 381 (15) 2930 (774) 24 3007 (118) 6615 (14584) 6063 (13365) 584 (23) 3083 (121) 7139 (15739) 6587 (14520) 660 (26) 5767 (1523) 48 3236 (127) 7339 (16184) 6787 (14965) 813 (32) 10009 (2644) 72 6731 (265) 2591 (102) 3499 (138) 8612 (18986) 8060 (17767) Sound (Level 2) and Standard Subbase Fuel Tank No Tank 0 5029 (198) 2423 (95) 5227 (11523) 4669 (10294) 0 (0) 2804 (110) 6297 (13965) 5739 (12736) 381 (15) 2905 (767) 24 5030 (198) 3083 (121) 6600 (14551) 6042 (13322) 660 (26) 6847 (15094) 6289 (13865) 5767 (1523) 48 6237 (246) 7231 (15942) 6673 (14713) Sound (Level 2) and State Subbase Fuel Tank 2804 (110) 6453 (14226) 5895 (12997) 381 (15) 2930 (774) 24 3007 (118) 6729 (14834) 6171 (13605) 584 (23) 3083 (121) 7253 (15989) 6695 (14760) 660 (26) 5767 (1523) 48 3236 (127) 7453 (16434) 6895 (15205) 813 (32) 10009 (2644) 72 6731 (265) 2591 (102) 3499 (138) 8726 (136) 8168 (18007) Sound Pressure Levels, db(a) [ 82 82 75 75 Note: Data in table is for reference only, refer to the respective ADV drawings for details. * Max. weight includes the generator set (wet) with largest alternator option, enclosure, silencer, and tank (no fuel). [ Log average sound pressure level of 8 measured positions around the perimeter of the unit at a distance of 7 m (23 ft). Refer to TIB-114 for details. G6-117 3/16g Page 7

KOHLER CO., Kohler, Wisconsin 53044 USA Phone 0-457-4441, Fax 0-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Fuel Tank Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz with Full Load 500REOZJ Max. Dimensions, mm (in.) Max. Weight, kg (lb.) * Fuel Tank Height, mm (in.) Length Width Height With Steel With Aluminum Weather and Standard Subbase Fuel Tank 2423 (95) 5077 (11193) 4524 (9974) 0 (0) 1734 (458) 12 2855 (112) 6231 (13736) 5678 (12517) 432 (17) 5030 (198) 3347 (884) 24 3210 (126) 6554 (14450) 6001 (13231) 787 (31) 5767 (1523) 36 6237 (246) 7081 (15612) 6529 (14393) 6659 (1759) 48 63 (273) 7323 (16144) 6770 (145) Weather and State Subbase Fuel Tank 1771 (468) 12 2804 (110) 6378 (14062) 5825 (12843) 381 (15) 3385 (894) 24 3083 (121) 6657 (14676) 6104 (13457) 660 (26) 5767 (1523) 36 3236 (127) 7305 (16104) 6752 (14885) 813 (32) 6675 (1763) 48 7438 (16397) 6885 (15178) 10009 (2644) 72 6731 (265) 2591 (102) 8576 (18906) 8023 (17687) Sound (Level 1) and Standard Subbase Fuel Tank 2423 (95) 5113 (11273) 4560 (10054) 0 (0) 1734 (458) 12 2855 (112) 6267 (13816) 5714 (12597) 432 (17) 5030 (198) 3347 (884) 24 3210 (126) 6591 (14530) 6038 (13311) 787 (31) 5767 (1523) 36 6237 (246) 7118 (156) 6565 (14473) 6659 (1759) 48 63 (273) 7359 (16224) 6806 (15005) Sound (Level 1) and State Subbase Fuel Tank 1771 (468) 12 2804 (110) 6415 (14142) 5862 (123) 381 (15) 3385 (894) 24 3083 (121) 6693 (14756) 6140 (13537) 660 (26) 5767 (1523) 36 3236 (127) 7341 (16184) 6788 (14965) 813 (32) 6675 (1763) 48 7474 (16477) 61 (15258) 10009 (2644) 72 6731 (265) 2591 (102) 8612 (18986) 8059 (17767) Sound (Level 2) and Standard Subbase Fuel Tank No Tank 0 5029 (198) 2423 (95) 5227 (11523) 4669 (10294) 0 (0) 1734 (458) 12 2855 (112) 6380 (14066) 5823 (12837) 432 (17) 5030 (198) 3347 (884) 24 3210 (126) 6704 (14780) 6147 (13551) 787 (31) 5767 (1523) 36 6237 (246) 7231 (15942) 6674 (14713) 6659 (1759) 48 63 (273) 7472 (16474) 6915 (15245) Sound (Level 2) and State Subbase Fuel Tank 1771 (468) 12 2894 (110) 6528 (143) 5971 (13163) 381 (15) 3385 (894) 24 3083 (121) 6807 (15006) 6249 (13777) 660 (26) 5767 (1523) 36 3236 (127) 7454 (16434) 6897 (15205) 813 (32) 6675 (1763) 48 7587 (16727) 7030 (15498) 10009 (2644) 72 6731 (265) 2591 (102) 8725 (136) 8168 (18007) Sound Pressure Levels, db(a) [ 84 84 76 76 Note: Data in table is for reference only, refer to the respective ADV drawings for details. * Max. weight includes the generator set (wet) with largest alternator option, enclosure, silencer, and tank (no fuel). [ Log average sound pressure level of 8 measured positions around the perimeter of the unit at a distance of 7 m (23 ft). Refer to TIB-114 for details. DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability. 2011, 2012, 2013, 2016 by Kohler Co. All rights reserved. G6-117 3/16g Page 8