The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use



Similar documents
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

L A C-M AIR OIL COOLER LUFT/ÖL-KÜHLER OILTECH COOLERS. Oiltech LAC-M for industrial hydraulics in aggressive environments

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Series description: Wilo-Drain TC 40

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Rotary screw compressors kw 5,5 7, , bar MODULO

ECOCIAT. Domestic hot water heat recovery unit

RS-D and RSF-D series with direct drive

RADIAL PISTON PUMPS (RKP)

Fixed displacement vane pumps

Radial piston pumps type R and RG

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Data sheet ECC 12 and 22

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

3/2- and 2/2-way cartridge valve type BVE

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Specifications for Volkswagen Industrial Engine

Screw Compressors ESM Fixed Speed & VS Variable Speed

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Filter Elements E /05.06

Automatic Back-Flushing Filter AutoFilt RF9.

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

ROTARY SCREW COMPRESSOR. RMD kw

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Refrigerated Air Dryers. Catalogue

industry revolves around

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Atlas Copco Stationary air compressors

Refrigeration Compressed Air Dryer Buran Ultrapulse

Overheating limit control

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Refrigeration Air Dryers. Catalogue

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

DRYPOINT RA REFRIGERATION DRYER RANGE

Directional seated valves type VP 1

PUMP AND MOTOR DIVISION

Workshop Compressors CLASSIC Series

300 Series PA Pump and Cooler Assemblies

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Screw Compressors 11-22kW

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical data. Danfoss DHP-A

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Chapter 5: Flow Valves

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

ThermoStar Refrigeration Air Dryers

Pressure reducing valve, direct operated, Type ZDR 6 D

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

AIRROLLAIR COMPRESSORS E

Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Atlas Copco Industrial Aluminium Piston Compressors. L Series Oil-lubricated & oil-free ( kw / 2-20 hp)

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

State of the Art Energy Efficient Data Centre Air Conditioning

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Data Center Cooling. The engineer s choice

RH 12.5 RH Crawler Excavator Specifications

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

Mobile Machines UPDATE Use HYDAC Expertise to avoid Air in Hydraulic Systems

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

These pumps provide a well proven solution in many cases.

Transformer oil cooler ALFA A02

Overview of types. Technical data

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

Stroom voor elke toepassing

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

BR I Blood Bank Refrigerators

Material test chamber with mechanical convection

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Test Report issued under the responsibility of:

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Are these noise cancelling devices needed to make your chiller quiet??

ZU4-Series, Portable Electric Pumps

The conditions below apply to the curves shown on the following pages.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Cooling kw Heating kw

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Thermostatic valve Type AVTA

Micro oil-mist lubricator, Series NL2-LBM G 1/4

Transcription:

The Professional Choice LDC With DC motor OLAER LDC optimized for mobile use

Olaer is a global player specialising in innovative, efficient system solutions for temperature optimisation and energy storage. All over the world, our products are working in the most diverse environments and applications. LDC Air Oil Coolers For mobile use - maximum cooling capacity 30 kw The LDC air oil cooler with 12 or 24 V DC motor is optimized for use in the mobile industry. Together with a wide range of accessories, the LDC cooler is suitable for installation in most applications and environments. The maximum cooling capacity is 30 kw at ETD 40 C. Choosing the right cooler requires precise system sizing. The most reliable way to size is with the aid of our calculation program. This program, together with precise evaluations from our experienced, skilled engineers, gives you the opportunity for more cooling per invested. Overheating - an expensive problem An under-sized cooling capacity produces a temperature balance that is too high. The consequences are poor lubricating properties, internal leakage, a higher risk of cavitation, damaged components, etc. Overheating leads to a significant drop in cost-efficiency and environmental consideration. Cooling capacity Lifetime Temperature optimisation - a basic prerequisite for cost-efficient operation Temperature balance in a hydraulic system occurs when the cooler can cool down the energy input that the system does not consume - the system s lost energy (Ploss = Pcool = Pin Pused). Temperature optimisation means that temperature balance occurs at the system s ideal working temperature the temperature at which the oil s viscosity and the air content comply with recommended values. The correct working temperature produces a number of economic and environmental benefits: The hydraulic system s useful life is extended. The oil s useful life is extended. The hydraulic system s availability increases more operating time and fewer shutdowns. Service and repair costs are reduced. High efficiency level maintained in continuous operation the system s efficiency falls if the temperature exceeds the ideal working temperature. 2 www.olaer.com

Clever design and the right choice of materials and components produce a long useful life, high availability and low service and maintenance costs. Compact design and low pressure drop and high cooling capacity. Easy to maintain and easy to retrofit in many applications. DC motor 12V/24V Quiet fan and fan motor. Compact design and low weight. Smart DC Drive Smart DC Drive for soft start of fan, as well as lower power consumption and sound level by means of temperaturecontrolled speed regulation. Smart DC Drive also eliminates voltage peaks, thus contributing towards a longer useful life for the fan motor. The Professional Choice 3

OLAER LDC Calculate the cooling capacity requirement Cooling capacity requirement? Installed capacity Flow? Pressure? Pump capacity? Measure in your existing unit Contact our engineers Theoretical capacity losses Choose the right kind of cooler Enter your values...... suggested solution 4 www.olaer.com

Better energy consumption means not only less environmental impact, but also reduces operating costs, i.e. more cooling per invested. More cooling per with precise calculations and our engineers support Optimal sizing produces efficient cooling. Correct sizing requires knowledge and experience. Our calculation program, combined with our engineers support, gives you access to this very knowledge and experience. The result is more cooling per invested. The user-friendly calculation program can be downloaded from www.olaer.se. Valuable system review into the bargain A more wide-ranging review of the hydraulic system is often a natural element of cooling calculations. Other potential system improvements can then be discussed e.g. filtering, offline or online cooling, etc. Contact us for further guidance and information. OLAER s quality and performance guarantee insurance for your operations and systems A constant striving towards more cost-efficient and environment friendly hydraulic systems requires continuous development. Areas where we are continuously seeking to improve performance include cooling capacity, noise level, pressure drop and fatigue. Meticulous quality and performance tests are conducted in our laboratory. All tests and measurements take place in accordance with standardised methods - cooling capacity in accordance with EN1048, noise level ISO 3743, pressure drop EN 1048 and fatigue ISO 10771-1. For more information about our standardised tests, ask for OLAER s blue book a manual for more reliable cooler purchasing. The Professional Choice 5

OUTLET (with bypass type S) The cooling capacity curves are based on the inlet oil temperature and the ambient air temperature. An oil temperature of 60 C and an air temperature of 20 C produce a temperature difference of 40 C. Multiply by kw/ C for total cooling capacity. TYPE A B C D E F G H I J K L Mø N O P Weight kg (approx) Acoustic Pressure LpA db(a)1m* LDC 002 184 74 72 189 94 G½ 187 72 100 107 157 36 9-11 25 4 66 LDC 003 244 134 82 227 71 G1 146 90 118 102 147 26 9x14-23 35 5 68 LDC 004 267 134 82 253 72 G1 146 90 131 107 152 26 9x14-23 35 6 68 LDC 007 330 203 82 338 59 G1 267 160 173 105 170 57 9-23 44 9 71 LDC 011 400 360 82 396 65 G1 101 230 200 125 218-9x29-23 44 12 74 LDC 016 464 416 82 466 63 G1 101 300 235 125 128-9x29-23 44 15 74 LDC 020 510 470 82 510 61 G1 101 280 257 125 211-9x29-23 44 18 77 LDC 023 615 356 46 635 26 G1 290 305 200 125 218 50 13 455-8 25 77 LDC 033 635 356 82 678 59 G1¼ 290 406 220 165 258 50 13 478 25 49 30 77 * = Noise level tolerance ± 3 db(a) 6 www.olaer.com

Cooling capacity kw/ C Cooling capacity kw/ C 0,80 0,80 0,70 0,70 Cooling capacity Cooling capacity LDC 002 LDC 033 LDC 002 LDC 033 0,60 0,60 023 023 0,50 0,50 0,40 0,40 0,30 0,30 0,20 0,20 007 0,10 003 0,10 003 0 50 100 150 200 250 300 Oil flow 0 Cooling capacity tolerance ± 10% kw. l /min 50 100 150 200 250 300 Oil flow Pressure l /min drop Pressure bar 016, 020, 023 drop 3,0 bar Pressure drop 016, 020, 023 3,0 2,6 2,6 Pressure drop At 30 cst single-pass At 30 cst single-pass 007 2,2 2,2 1,8 003, 004 003, 004 1,8 1,4 1,4 1,0 1,0 0,6 0,6 0,2 0,2 50 100 150 200 250 Oil flow l /min 50 100 150 200 250 Oil flow l /min The Professional Choice 7

Key for LDC air oil coolers All positions must be filled in when ordering EXAMPLE: LDC - 016 - A - S - 00 - S20 - S - 0 1 2 3 4 5 6 7 8 1. AIR OIL COOLER WITH DC MOTOR = LDC 2. COOLER SIZE 002, 003, 004, 007, 011, 016, 020, 023, 033 3. Motor Voltage 12 V = A 24 V = B 4. Accessories for DC Motor No motor accessories = 0 Smart DC Drive, incl. temperature indicator 50 C = S Relay box = C 5. THERMO CONTACT No thermo contact = 00 40 C = 40 50 C = 50 60 C = 60 70 C = 70 80 C = 80 90 C = 90 6. COOLER MATRIX Standard = 000 Two-pass = T00 Built-in, pressure-controlled bypass, single-pass 2 bar = S20 5 bar = S50 8 bar = S80 Built-in, pressure-controlled bypass, two-pass* 2 bar = T20 5 bar = T50 8 bar = T80 Built-in temperature and pressure-controlled bypass, single-pass 50 C, 2.2 bar = S25 60 C, 2.2 bar = S26 70 C, 2.2 bar = S27 90 C, 2.2 bar = S29 Built-in temperature and pressure-controlled bypass, two-pass* 50 C, 2.2 bar = T25 60 C, 2.2 bar = T26 70 C, 2.2 bar = T27 90 C, 2.2 bar = T29 * = not for LDC 002 - LDC 004 7. MATRIX GUARD No guard = 0 Stone guard = S Dust guard = D Dust and stone guard = P Technical specification Fluid combinations Mineral oil HL/HLP in accordance with DIN 51524 Oil/water emulsion HFA, HFB in accordance with CETOP RP 77H Water glycol HFC in accordance with CETOP RP 77H Phosphate ester HFD-R in accordance with CETOP RP 77H Material Cooler matrix Fan blades/guard Fan housing Other parts Surface treatment Aluminum Glass fibre reinforced polypropylene Steel Steel Electrostatically powder-coated cooler matrix Maximum static working pressure 21 bar Dynamic working pressure 14 bar* Heat transfer tolerance ± 6 % Maximum oil inlet temperature 120 C * Tested in accordance with ISO/DIS 10771-1 Electric motor LDC 002 003 004 007-020 023-033 Speed (rpm) 3 700 3 670 3 350 3 060 3 060 Protection std. IP 68 IP 68 IP 68 IP 68 IP 68 Insulation class H H H H H Ambient temp. -30 C - +80 C Power consump. (A) 12V 6.5 8 8 20 2x20* (A) 24V 3.5 4 4 10 2x10* * = LDC 023 and LDC 033 have two motors Use a relay if the current load is superior to: 8 A at 12V and 6 A 24V Cooling capacity curves The cooling capacity curves in this technical data sheet are based on tests in accordance with EN 1048 and have been produced using oil type ISO VG 46 at 60 C. Contact olaer for advice on Oil temperatures > 120 C Oil viscosity > 100 cst Aggressive environments Ambient air rich in particles High-altitude locations Connection chart Connection chart for LDC air oil cooler. 8. Standard/special Standard Special = O = Z The information in this brochure is subject to change without prior notice. 8 www.olaer.com

With our specialist expertise, industry knowledge and advanced technology, we can offer a range of different solutions for coolers and accessories to meet your requirements. Take the next step - choose the right accessories Supplementing a hydraulic system with a cooler, cooler accessories and an accumulator gives you increased availability and a longer useful life, as well as lower service and repair costs. All applications and operating environments are unique. A well-planned choice of the following accessories can thus further improve your hydraulic system. Please contact Olaer for guidance and information. Pressure-controlled bypass valve Integrated Allows the oil to bypass the cooler matrix if the pressure drop is too high. Reduces the risk of the cooler bursting, e.g. in connection with cold starts and temporary peaks in pressure or flow. Available for single-pass or two-pass matrix design. Smart DC Drive speed regulation For cost-efficient operation and better environmental consideration through speedregulated fan control the higher the temperature, the higher the fan speed. Temperature-controlled bypass valve Integrated Same function as the pressure-controlled by pass valve, but with a temperature-controlled opening pressure - the hotter the oil, the higher the opening pressure. Available for single-pass or two-pass matrix design. Stone guard/dust guard Protects components and systems from tough conditions. Thermo contact Sensor with preset fix point. For temperature warnings, and for more cost-efficient operation and better environmental consideration through the automatic switching on and off of the fan motor. Temperature-controlled 3-way valve External Same function as the temperature-controlled bypass valve, but positioned externally. Note: must be ordered separately. The Professional Choice 9

Professional competence as well as advanced technology and extensive knowledge from the industry, allow us to provide many cooler combinations, which meet your unique needs. Combinations providing optimal solutions A close collaboration between our application engineers, designers and you as customer during the whole project will result in a high-quality product. The final product will be a tailor-made cooler, which always meet your unique needs. Extensive choices Long-term experience from the mobile field has provided us with a unique ability to deliver the ideal combination cooler solution. Depending on the conditions, the cooler fan can be operated by the diesel engine on the machine or by a hydraulic motor or a DC motor. We can also supply many different cooler combination options. A frequent combination is the side-by-side -cooler, where the coolers are placed side-by-side, no matter the media, such as a water cooler, an oil cooler and an intercooler. Another solution is the sandwich -cooler, where the coolers are placed in front of each other. The solution could also be a combination of these two. No matter which combination will be used, the pressure drop and the heat dissipation across the matrix will always be optimal. 10 www.olaer.com

The Professional Choice 11

The Professional Choice - in Fluid Energy Management Global perspective and local entrepreneurial flair Olaer is a global player specialising in innovative, efficient system solutions for temperature optimisation and energy storage. Olaer develops, manufactures and markets products and systems for a number of different sectors, e.g. the aircraft, engineering, steel and mining industries, as well as for sectors such as oil and gas, contracting and transport, farming and forestry, renewable energy, etc. All over the world, our products operate in the most diverse environments and applications. One constantly repeated demand in the market is for optimal energy storage and temperature optimisation. We work at a local level with a whole world as our workplace local entrepreneurial flair and a global perspective go hand in hand. Our local presence, long experience and a wealth of knowledge combine with our cutting-edge expertise to give you the best possible conditions for making a professional choice. Copyright 2010 OLAER - The information in this brochure is subject to change without prior notice. www.olaer.com