TORO STEEL BUILDINGS. BOLTS: o - 0.635" diam. x - 0.75 " diam. x - 1.00 " diam. C.J. - Control Joints to minimize cracking.(0.



Similar documents
Chapter 3 Pre-Installation, Foundations and Piers

SECTION EARTH MOVING

COMMONLY USED RESIDENTIAL BUILDING CODES

The minimum reinforcement for the stem wall is the placement of:

C. Section TESTING LABORATORY SERVICE.

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Residential Foundations and Basements

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

Proposed Minimum Subterranean Termite Treatment Standards

Construction Specification for Concrete Curb and Concrete Curb and Gutter

Cold Weather Concrete Practices

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Lighthouse Engineering, L.L.C.

Superform Products Ltd.

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Detailing of Reinforcment in Concrete Structures

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

Installation PowerPoint for Grasscrete Formers

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

MUNICODE SERVICES LTD.

SECTION CAST-IN-PLACE CONCRETE

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

International Greenhouse Company

Residential Deck Safety, Construction, and Repair

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Structural Foundation System

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

ATLANTA MODEL SPECIFICATIONS

SECTION 1 GENERAL REQUIREMENTS

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Additions and Alterations

Ohio Board of Building Standards Building on the Code Education Series. Residential Code of Ohio Chapter 4 March 1, Presentation Handout

symptoms of a faulty foundation

Section 2100-Trenching and Tunneling

SECTION STORM DRAINAGE SYSTEM

Page & Turnbull imagining change in historic environments through design, research, and technology

EAST LYME HIGH SCHOOL

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

No allowance will be made for classification of different types of material encountered.

Soils, Foundations & Moisture Control

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Designed and Engineered to Perform

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Design and Construction of Cantilevered Reinforced Concrete Structures

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

DESIGNING STRUCTURES IN EXPANSIVE CLAY

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

MANUFACTURED HOUSING USED AS DWELLINGS

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

IRC 2009 CODE REQUIREMENTS FOR CIP CONCRETE FOUNDATIONS SUPPORTING LIGHT FRAME CONSTRUCTION IN SEISMIC DESIGN CATEGORY B (WITH QUESTIONS AND ANSWERS)

Safe & Sound Bridge Terminology

Structures Construction Pre-Work Checklist PRE-WORK SHEET FOR PROJECT MANAGERS

Engineered Wood Foundations

TECHNICAL SPECIFICATIONS CONCRETE SIDEWALKS, DRIVEWAYS AND CURB AND GUTTER

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

MATERIALS. Table 1 Mortar Proportions by Volume (Ref. 12)

Chapter. Restoration of Damaged Structures

Metropolitan Builders Association Masonry & Concrete Standard

ATLAS RESISTANCE Pier Foundation Systems

PART 1 GENERAL 1.1 SECTION INCLUDES

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

Moving Small Mountains Vesuvius Dam Rehab

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

SECTION 3 SANITARY SEWER DESIGN

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Underpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles

Chapter 7 Plumbing Connections

Residential Decks. Planning and Development Services Department

Foundation Code compliance and Best Practices By Michael Coello

SECTION STORM DRAIN SYSTEM

Sonotube Instructions for PreFab Sheds

Mobile Home Pre-Inspection Checklist

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

The AASHO Road Test site (which eventually became part of I-80) at Ottawa, Illinois, was typical of northern climates (see Table 1).

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

Basement Moisture Problems

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Transcription:

100 ' 0 " out to out of steel C 1 ' 3.25 " B Keep This Distance 37 ' 5.5 " ll sections and bolts have been blown up for clarification of placement. They are to be centered as much as possible on pier. For anchor bolt placement, please refer to the steel building drawings (Pages F1 and F3 ). 40 ' 0 " out to out of steel 1 ' 3.25 " 1 1.5" 2 3 4 1.5" CONCRETE NOTCH DETIL SEC - BOLTS: o - 0.635" diam. x - 0.75 " diam. x - 1.00 " diam. - Control Joints to minimize cracking.(0.5" saw cut) San Martin,C. Page 1 PLN VIEW 1

100 ' 0 " out to out of steel 1 ' 3.25 " C 40 ' 0 " out to out of steel ll sections and bolts have been blown up for clarification of placement. They are to be centered as much as possible on pier. For anchor bolt placement, please refer to the steel building drawings (Pages F1 and F3 ). Keep This Distance 37 ' 5.5 " B 1 ' 3.25 " 3 1.5" 4 5 6 1.5" CONCRETE NOTCH DETIL SEC - BOLTS: o - 0.625" diam. x - 0.75 " diam. x - 1.00 " diam. - Control Joints to minimize cracking.(0.5" saw cut) San Martin,C. Page 2 PLN VIEW 1a

CONCRETE REBRS BR DESIG. # (OLD STD.) NOMINL DIMETER #3 0.375" 10 #4 0.500" 13 #5 0.625" 16 #6 0.750" 19 #7 0.875" 22 #8 1.000" 25 #9 1.128" 29 NEW DESIGN. NUMBER #10 1.270" 32 #11 1.410" 36 #14 1.693" 43 #18 2.257" 36 WELDED WIRE MESH DESIGNTION OLD DESIGNTION NEW DESIGNTION 6 x 6-6 ga x 6 ga 6 x 6(spacings) - W2.9 x W2.9 San Martin,C. Page 3 rebars

base plate Lp Side Wall (out) Dp SIDE WLL HIRPIN DETIL (TYP.) 16 rebar -72" long (typ.) End Wall (out) Lp Dp lternate Head detail Penetration in Concr. base pl. (centered on pier) hook washer diam. Bolt detail-steel Grade 307 - typ. ELEMENT PIER Diam. Penetration Bolt in Conc. Hook 0.75" 18.0" 3.0"/lt. 1.00" 18.0" 3.0"/lt. 0.625" 18.0" 3.0"/lt. Diam. Penetration Bolt in Conc. Hook 0.625" 6.0" Not.Req. 0.75" 6.0" Not.Req. CONC. COVER 3" TYP. 2" TYP. BOLT DETILS FOR RIGID FRMES, PORTL FRMES ND WIND COLUMNS BOLT DETILS FOR NON-STRUCTURL PPLICTIONS base plate END WLL HIRPIN DETIL (TYP.) 16 rebar -60" long (typ.) base plate Lp Side Wall (out) SLB-ON-GRDE SPECIFICTIONS 6" (Six Inch) Thick Concrete with 6" x 6" MW 18.7 WWF on 6 mil Polyethylene Sheet Barrier with a minimum 6" thick layer of 0-0.75" crushed gravel, compacted to 95% STNDRD PROCTOR DENSITY on UNDISTURBED SOIL. In order to minimize surface shrinkage cracks in the slab, provide control joints at every 20' approximately (0.5" saw cut ). End Wall (out) Dp Estimated Frost Depth : 1 ' 0 " Confirm with Local uthorities. San Martin,C. CORNER HIRPIN DETIL (TYP.) 16 rebar -60" long (typ.) Page 4 slab details

SCHEDULE & DIMENSIONS Section B-B C-C B C Rebar Tie Tie Spacing 30.0" 33.0" 6.0 " 6-19 10 24.0" 30.0" 33.0" 6.0 " 6-19 10 24.0" Base Pl. Length * * * * Base Pl. Width column concrete notch Grade Level 9.5" sidewall for Sec B-B endwall for Sec C-C base plate length base plate * Refer to the anchor bolt drawings issued by the steel building manufacturer (Pages F1 and F3). 4' min. rebar tie 45 Soil C -crushed gravel (6" min.) -6 Mil Polyethylene B 2" rigid insulation may be necessary for frost depth only.(site-specific) Project : San Martin, California Width : 40' Length : 100' Bay Spacing for Frames : 20' Use of : Hazardous/Corrosive Materials : None llowed Concrete 28 day Strength : 2500 psi Steel Grade for Concrete Reinforcement : 60 Ksi (420 Mpa) Steel Grade for Threaded nchor Bolts : 307 Minimum llowable Soil Bearing Capacity Required : 1500 psf (75 Kpa) Foundation must have adequate drainage provided. SLB-ON-GRDE SPECIFICTIONS 6" (Six Inch) Thick Concrete with 6" x 6" MW 18.7 WWF on 6 mil Polyethylene Sheet Barrier with a minimum 6" thick layer of 0-0.75" crushed gravel, compacted to 95% STNDRD PROCTOR DENSITY on UNDISTURBED SOIL. In order to minimize surface shrinkage cracks in the slab, provide control joints at every 20' approximately (0.5" saw cut ). San Martin,C. Float. Slab Page 5 floating slab

CST-IN PLCE CONCRETE 1. Conform to the requirements of CI-318, CI-211 for concrete mix components, placing, curing, and testing. 2. Cement: Normal (Type 10) Portland Cement conforming to CI-318. 3. Form-work : Conforming to C1-318 Treat all form-work surfaces in accordance with the requirements of CI-318 and CI-347. 4. ll concrete shall have a maximum aggregate of 1",a minimum compressive 28 day strength of 2500 psi ( 25 MPa), and a slump at discharge of 3" +/- 1.No more than 1 gallon of water per cubic yard, shall be added at the site without the approval of the engineer. 5. Reinforcing steel for all reinforcement use deformed bars of Grade 420 MPa (60 Ksi). Comply with the requirements of CI-318 and STM- 615 for all reinforcement. 6. Conform to STM-185 requirements for welded wire fabric. Minimum yield strength: 65 Ksi ( 450 MPa). 7. Dowel all walls and piers to their respective footings, or supports, using dowels of same size, and spacing as the vertical reinforcing steel in the walls, and piers, unless noted otherwise. 8. Detail and bend all reinforcing steel as outlined in the latest issue of the Local Reinforcing Steel Manual of standard practice. 9. Lap continuous reinforcing steel 30 bar diameters at splices and corners, unless otherwise noted. 10. Unless otherwise noted, provide the following clear cover to reinforcing steel: a) Formed piers not exposed to soil and weather : 1.5 b) Formed concrete exposed to soil and weather : 2 c) Concrete on skim slab : 2 d) Concrete placed on soil : 3 e) Top of slab-on-grade to welded wire fabric : 1.5 11. ir-entrain all concrete exposed to the elements, plus all slabs-on -grade to the requirements of CI-318 and CI-302. 12. Provide 0.5 expansion material where slab-on-grade abuts walls, columns, piers, and the vertical face of other structural elements, unless noted otherwise. 13. Chamfer all exposed corners of concrete piers 0.75 x 0.75, to avoid corner damage. 14. Slab on Grade Specifications : 6 thick concrete slab-on-grade, with 152 x 152 - MW 18.7/MW 18.7 WWF( 6 x 6-6/6 WWF) on 6 -mil polyethylene sheet barrier, with a minimum of 6 type B granular non-organic backfill, compacted to 98 % standard proctor density, on undisturbed soil. 15. Control joints for slabs to minimize concrete cracking, () are recommended along approximately 20' grid lines. Provide 0.5 deep saw cut as per Foundation plan. 16. Install steel frames after the slab has been completed. FOUNDTION 1. The foundations have been designed for an assumed minimum allowable soil-bearing capacity of 1500 psf. (75 Kpa).Found all footings on natural undisturbed inorganic soil.for any other type of soil, the customer shall provide soil reports indicating the allowable net soil-bearing capacity. For foundations on solid rock, remove all fragmented rocks to ensure a solid surface for the foundation to sit on. Drill holes in rock, and use concrete epoxy jacket to anchor rods in place. 2. If the safe net bearing soil pressure is other than the assumed value of 1500 psf (75 Kpa), the design engineer is to be informed, and additional cost for the design and materials may apply. 3. Remove any soft or frozen soil material encountered under footings, and replace with compacted structural fill. If soil under footings has been disturbed,remove all loose soil prior to placing concrete. San Martin,C. Page 6 discl1

4.Install the underside of all exterior wall and column footings, below frost line, and the finished new grade. Protect all footings, walls, slab-on grade, and adjacent soil against freezing and frost-action at all times during construction. Refer to local building code for the required frost depth. In case of a floating slab foundation type, provide sufficient insulation underneath slab, and around the building perimeter, to prevent frost damage to the foundation. 5. Center piers under the column centers, unless otherwise noted. 6. If soil softening occurs before footing concrete can be poured, or as required by the soil report, construct the footings on a level 2 thick skim slab having 2000 psi concrete strength at 28 days, placed immediately after the completion of the excavation. 7.Locate footing elevations as required to accommodate buried electrical or mechanical services. Protect existing and adjacent footings from being undermined, and overloaded, by limiting the slope of the line between adjacent footing elevations to 7 to 10 maximum, having a maximum rise of 2'-0".Verify local required frost depth to ensure that the bearing surface of the foundation is located below the level of potential damage resulting from frost heave of soil, and ad-freezing of the concrete. Proper rigid insulation may be required, in accordance to local building codes. 8. Backfill under slab-on grade granular non -vegetative, type B backfill material, compacted in 6 maximum lifts to 98% standard proctor density at optimum moisture content. 9. The slab-on-grade may only be placed on non-vegetative fill. The engineer must examine all fill material. Should the fill be unacceptable, remove this fill down to undisturbed soil, and replace with compacted granular, non-vegetative type B backfill, compacted in 6 maximum lifts, to 98% standard proctor density, at optimum moisture content. 10. Do not place backfill against cantilevered retaining wall, until the concrete has achieved its full 28 -day strength. 11. Provide 0.5 expansion joint with filler, where indicated. 12. Landscaping around the entire foundation shall include a 5' wide strip of inert ground cover. Irrigation shall be designed so as not to discharge water on this strip. The slope of the ground surface shall provide adequate drainage away from the building foundation. 13. The foundation design engineer is not the inspecting engineer at the site. GENERL 1. Use only the latest issues of any government building codes, standards, or regulations mentioned in the following notes. 2. Except where noted otherwise, provide all materials and workmanship in accordance with the requirements of the latest regulations of the appropriate building code, 3. Verify all dimensions, levels, and elevations provided by the structural drawings with other contract documents, and report any inconsistencies to the engineer, before proceeding with the work. 4.Read the structural drawings in conjunction with specifications, and other contract drawings. 5. Specific notes and details shown on the structural drawings, take precedence over the general notes, and typical details. 6. Co-ordinate with all other trades, where such trades affect the structure. 7. The structural design of the building is based on the full interaction of all its components and parts. No provisions have been made for site-specific conditions. dequate provisions for construction conditions must be maintained to keep the structure plumb and level, through all its phases. 8. No holes, other than those specified by the engineer may be drilled in any members. 9.Lateral pressure of soil against retaining walls (if applicable), has been calculated for a pressure of 46.00 psf, (assuming drained material). 10. Site Inspection and soil testing (if required by the municipality) is not provided by Toro Steel s nor the foundation design engineer. 11. This foundation has been designed based on the reactions provided by the building manufacturer. Page 7 discl2 San Martin,C.