User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors



Similar documents
User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion

MFT Series INTRODUCTION UNPACKING FERRULES

OME-SERIES DATA ACQUISITION CARDS

User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. info@omega.com

User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com info@omega.com For latest product manuals: omegamanual.

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at

User s Guide. SW DIN Series and OSW Series. Shop online at. Rotary Selector Switches

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM


Shop online at: omega.com For latest product manuals: omegamanual.info

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

User s Guide WRS232-USB. Universal Wireless RS232 to USB Transceiver, WRS232 Wireless Transmitter, WUSB Wireless Receiver.

User s Guide OM-USB-TC. 8 Channel Thermocouple Input USB Data Acquisition Module. Shop online at

DL AND DBA SERIES CONNECTORS QUALIFIED TO MIL-DTL SERIES III Weight-saving aluminum connectors designed for rugged use and high temperatures

Duct Temperature Sensors

User s Guide OM-MICROLITE-8 AND OM-MICROLITE-16 DATA LOGGERS AND OM-MICROLAB-LITE SOFTWARE. Shop online at

Pipe Temperature Sensors

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

AMPSEAL* Automotive Plug Connector and Header Assembly

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

MTV-FS1 / FS1T / FSB375

Advantium 2 Plus Alarm

81000 Series Aluminum Gate Valve Installation and Repair Manual

Air Conditioning Systems Warranty Manual. Version 1.8

RT-200 HI-TEST ROPE TESTER

ATS Overhead Table Shelf System INSTRUCTION MANUAL

MTX-D, Oil Temperature/Pressure Gauge

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Old Company Name in Catalogs and Other Documents

About this Manual. Support for Your Product

Mounting Details - Footpads & Brackets

Triple Expansion Chassis

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

24.2L M.A.N. V12 Engine Module

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Installation Instructions

In-Tank Fuel Pump Installation Instructions (Read Carefully Before Starting Project)

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

DCX300 - DCX400 - DCX600

Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide

Waterproof Connectors for Outdoor Use

Quick Connect Boxes Inside Gloveboxes

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Model SRMD Setra Remote Monitoring Display

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

For Models #6-5001, #6-7501, # & #10-12K1

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

Sip/Puff Switch User Guide

Subminiature Load Cell Model 8417

Single Port T1/E1 Tap

Directory chapter 04

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Mini USB and USB 2.0-IP67 Connector System

Ozone Generator Manual

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Installation Guide Smart-UPS X External Battery Pack SMX120BP

12-Volt Negative Ground Installation Instructions

ECM-D70T / ECM-D70T1.5

Laptop Power Adapter for home/office User Manual

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

VK-250 WARRANTY REGISTRATION FORM

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Universal Vehicle Power Supply 9007AX01. Installation Instructions

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

The Wild Children of D38999

Limited Warranty Letter for BYD Photovoltaic Module

369 SERIES CONNECTORS

TBM5, TBM5-S and TBM5-SV

SMA Connectors. RF Coax Connectors. Product Facts

Triton Systems of Delaware, LLC. Warranty Statement

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

Retractable Screen. Replacement Screen Instructions

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

SOURIAU s discrete wire sealing

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

Glenair Military and Industrial Power and Signal Connectors

Calvert USA, Inc. Attic Stairs

HotLok Pass Through Blanking Panel

ExStik TM ph Waterproof Meters

UTS discrete wire sealing

SAVARD PLUMBING COMPANY

BroadBand PowerShield. User Manual

Operating Instructions

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Transcription:

MADE IN User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info MTC SERIES Multi-Pin Thermocouple Connectors

OMEGAnet On-Line Service omega.com Internet e-mail info@omega.com U.S.A.: ISO 9001 Certified One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Servicing Europe: Czech Republic: Frystatska 184, 733 01 Karvina, Czech Republic Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de Servicing North America: Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canada: Mexico: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA En Espan ~ ol: (001) 203-359-7803 Customer Service: 1-800-622-2378 / 1-800-622-BEST FAX: (001) 203-359-7807 Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN e-mail: espanol@omega.com info@omega.com.mx United Kingdom: ISO 9002 Certified One Omega Drive River Bend Technology Centre Northbank, Irlam Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.

Table of Contents Page Section 1 Introduction........................... 1 1.1 General Description................................. 1 1.2 Features........................................... 1 Section 2 Unpacking............................. 2 Section 3 Operation............................. 2 3.1 Multi-Pin Connector Bodies.......................... 2 3.2 Thermocouple Contacts.............................. 4 3.3 Backshell Clamps................................... 8 3.4 Installing the Thermocouple Contacts.................. 8 3.4.1 Contact Termination................................. 8 3.4.2 Contact Insertion into the Connector.................. 10 3.4.3 Contact Removal................................... 12 i

SECTION 1 INTRODUCTION 1.1 General Description The OMEGA Multi-Pin Thermocouple Connectors provide a sturdy and efficient means of joining multi-wire thermocouple cables. They can be used with OMEGA Multipair Extension Cable for rapid, convenient connection and dismantling of apparatus without handling individual sensors. The design utilizes a combination of resilient and rigid dielectric insulators to eliminate internal air voids and prevent the passage of air and moisture into or through the connector. Connectors can withstand ambient temperatures up to 392 F (200 C) contributing to an extended connector life. The OMEGA Multi-Pin Thermocouple Connectors do not carry a MIL spec. number; however, they do meet the performance requirements of MIL-C 26500E and are intermateable with MIL-C 26500 connectors. 1.2 Features Thermocouple alloy pins and sockets Air and moisture resistant connection Rated to 392 F (200 C) Removable crimp contacts Accepts 20-24 gage wire Aluminum shells Black anodized finish Threaded coupling 1

SECTION 2 UNPACKING Remove the Packing List and verify that all equipment has been received. If there are any questions about the shipment, please call OMEGA Customer Service Department. Upon receipt of shipment, inspect the container and equipment for any signs of damage. Take particular note of any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE: The carrier will not honor any claims unless all ship ing material is saved far their examination. After examining and removing contents, save packing material and carton in the event reshipment is necessary SECTION 3 OPERATION 3.1 Multi-Pin Connector Bodies The contact cavities in the connectors are identified with a spiral guide line indicating cavity sequence (see Figure 3-1). The first and last cavities are numbered and every tenth cavity is bracketed. The number of available cavities are 5, 12, 24, 41, and 55. 2

Figure 3-1. Cavity Sequence 3

The multi-pin connector bodies come in three styles (plus backshell cable clamps), MC-male cord, FC-female cord, and FF-female flanged. A. MC-Male Cord (see Figure 3-2) In-line cord connectors with threaded couplings. MC style uses thermocouple alloy pins. B. Style FC-Female Cord (see Figure 3-3) In-line cord connectors with threaded couplings. FC style uses thermocouple alloy sockets. C. Style FF-Female Flanged (see Figure 3-4) Rugged flanged body for bulkhead and chassis mounting. It is a flange mounted receptacle with threaded coupling. FF style uses thermocouple alloy sockets. D. Backshell Cable Clamp Backshell cable clamps provide effective support for the cable at the male or female connector and prevent twisting and pulling. 3.2 Thermocouple Contacts The thermocouple contacts must be installed into the multi-pin connector bodies by the user. Styles FC and FF use the thermocouple alloy sockets; Style MC uses the thermocouple alloy pins. Pins and sockets must be matched to thermocouple alloys. The push-in crimp style contacts are machined from thermocouple alloy materials and color coded for easy identification. Gold plated copper (uncompensated) pins and sockets are available for use with nonthermocouple wire. Sealing plugs are also available to seal unused positions in lieu of a pin or socket. 4

M S T V Number Backshell Coupling Shell Shell Connector Shell of Clamp Nut Skirt Internal Body Size Cavities Thread Dia. Dia. Dia. MTC-5-MC 10 5 9 16-24 UNEF 0.906 0.526 0.444 MTC-12-MC 12 12 3 4-20 UNEF 1.078 0.696 0.614 MTC-24-MC 16 24 15 16-20 UNEF 1.266 0.892 0.810 MTC-41-MC 20 41 1 3 16-18 UNEF 1.510 1.123 1.041 MTC-55-MC 22 55 1 5 16-18 UNEF 1.625 1.248 1.166 Figure 3-2. MC Style Connector 5

M R S T Y Z Number Backshell Coupling Flange Locknut Mounting Mounting Connector Shell of Clamp Thread Width Flats Hole Hole Body Size Cavities Thread Dia. Flat MTC-5-FC 10 5 9 16-24 UNEF 11 16-24 1.104 15 16 0.076 0.730 MTC-12-FC 12 12 3 4-20 UNEF 7 8-24 1.291 1 1 8 0.947 0.917 MTC-24-FC 16 24 15 16-20 UNEF 1 1 16-18 1.516 1 5 16 1.135 1.105 MTC-41-FC 20 41 1 3 16-18 UNEF 1 5 16-18 1.860 1 9 16 1.385 1.350 MTC-55-FC 22 55 1 5 16-18 UNEF 1 7 16-18 1.954 1 11 16 1.510 1.475 1-3/8 MAX. 1.285.081/.087 SIZES 8 TO 14.122/.128 SIZES 16 TO 24 R THREAD.771 M THREAD 1-1/8 MAX. PANEL THICKNESS Figure 3-3. FC Style Connector 6

M R S T Y Z Number Backshell Coupling FlangeMounting Back Front Connector Shell of Clamp Thread Width Hole Mounting Mounting Body Size Cavities Thread Centers Hole Hole MTC-5-FF 10 5 9 16-24 UNEF 11 16-24.937 0.719 0.748 0.572 MTC-12-FF 12 12 3 4-20 UNEF 7 8-24 1.031 0.812 0.913 0.760 MTC-24-FF 16 24 15 16-20 UNEF 1 1 16-18 1.250 0.969 1.107 0.948 MTC-41-FF 20 41 1 3 16-18 UNEF 1 5 16-18 1.437 1.156 1.325 1.197 MTC-55-FF 22 55 1 5 16-18 UNEF 1 7 16-18 1.562 1.250 1.452 1.322 1-3/8 MAX. S 1.155 T.091/.097 SIZES 8 to 14.122/.128 SIZES 16 TO 24 T S R THREAD M THREAD.125/.116 SIZES 8 to 22 (4) HOLES.154/.145 SIZES 24 TO 28 Figure 3-4. FF Style Connector 7

3.3 Backshell Clamps (See Figure 3-9, Page 9). 3.4 Installing The Thermocouple Contacts 3.4.1 Contact Termination Contacts are crimp terminated onto the wire outside the connector assembly. A specially designed MS standard crimping tool (OMEGA MTC-CT) must be used to properly crimp wires to the pins or sockets. 1. Strip the wire (20 to 24 gage).170'' to.201''; avoid nicking the wires or damaging the insulation as it is a functional part of the sealing system. 2. Insert the stripped wire into the contact pocket until it is visible through the inspection hole (see Figure 3-6). 3. Fully seat contact in crimp tool positioner. 4. Crimp in one full stroke. (Ratchet action ensures a complete crimp every time.) 5. Inspect crimp for wire visibility through inspection hole. 8

Backshelf Max Max Clamp Dia. B Length Dia. D Dia. E MTC-5-SHL 3 4 2 1 3 8 MTC-12-SHL 1 2 1 1 8 1 2 MTC-24-SHL 1 1 8 2 1 2 1 1 2 5 8 MTC-41-SHL 1 3 8 2 1 2 1 1 2 5 8 MTC-55-SHL 1 1 2 3 1 5 8 7 8 MTC-5-SHL-A 3 4 2 3 4 MTC-12-SHL-A 1 2 7 8 1 8 3 16 MTC-24-SHL-A 1 1 8 2 1 2 1 5 16 MTC-41-SHL-A 1 3 8 2 1 2 1 1 8 7 16 MTC-55-SHL-A 1 1 2 3 1 1 8 1 2 LENGTH O-RING BODY DIA. "B" DIA. "E" DIA. "D" M THREAD PER FIGURE 3-2, 3-3, 3-4 SILICONE SEAL CLAMP CAP Figure 3-5. Backshell Clamps 9

Figure 3-6. Inserting the Stripped Wire into the Contact 3.4.2 Contact Insertion into the Connector Once the contacts are property crimped onto the wire, they are inserted into the appropriate cavity of the connector by means of an insertion tool (OMEGA s MTC-IT). Assembly of the contacts into the connector must be made with reasonable care to avoid damage to the insulation. 1. Lubricate the wire cavities in the back face of insert (on the connectors) with a very thin film of silicone oil, or equal, before inserting contacts. 2. Locate contact in insertion tool as shown in Figure 3-7. 3. Align contact with the hole in the rear face of the insert (see Figure 3-8). The alignment of the insertion tool with contact must be coaxial with the axis of the connector. When the contact has entered the rear seal portion of the insert, maintain alignment of contact and tool parallel to and in line with the hole. Insert the contact to full depth. User will hear contact click-in when seated fully in retention collet. 4. Remove insertion tool, keeping it aligned with the hole. 10

Figure 3-7. Locating Contact into Insertion Tool Figure 3-8. Aligning Contact 11

3.4.3 Contact Removal A contact is removed from the connector insert with the extraction tool (OMEGA s MTC-RT). 1. Set the space sleeve in the proper position for removal of male or female contact. 2. Place too[ over the contact and insert into the cavity (see Figure 3-9). The alignment of the removal tool with the contact must be coaxial with the axis of the connector. 3. Exert pressure axially to release retention collet. Spacer sleeve will shoulder at face of insulation when tool is inserted to proper depth. 4. Push extraction plunger to force the contact out of the rear of the insert. 5. Grasp contact or wire at the rear of the insert and pull to complete extraction. 6. Remove tool axially. 7. After using extraction tool the space sleeve should be set forward in last notch to protect the end of the plunger guide. 12

Figure 3-9. Alignment of Removal Tool 13

Notes 1. MS standard assembly tools are required to properly crimp and assemble connectors. 2. Match pins and sockets to thermocouple alloys. Example: A 12 cavity connector carries 6 thermocouple circuits (pairs) requiring 6 positive alloy pins or sockets, and 6 negative alloy pins or sockets per connector. 3. Order connectors in mating pairs. Style MC mates with Style FF. Style MC mates with Style FC. 4. Backshell cable clamps are recommended with each cord style connector. 14

Notes 15

WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2006 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers ph/conductivity ph Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial ph & Conductivity Equipment DATA ACQUISITION Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters HEATERS Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment ph, Conductivity & Dissolved Oxygen Instruments M0192/0306