Plasmax Plasma Concentration System BIOLOGICS



Similar documents
Plasmax Plasma Concentration System for Laparoscopic Roux-en-Y Gastric Bypass

HUMULIN 70/30 KwikPen

Collection Guidelines for Routine & Special Coagulation Testing

Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin)

ClikSTAR - Important facts about your new insulin delivery device.

Lentur Cable System. Surgical Technique

Central Line Blood Draw

Instructions for Use

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

Instructions for Use. Components of the GENOTROPIN PEN 12

Standard Operating Procedure (SOP) Work Package 8. Sample Collection and Storage

Blood Collection and Processing SOP

HUMULIN (HU-mu-lin) N

Aseptic Technique. A GMP/GTP Training Module

I-140 Venipuncture for Blood Specimen Collection

KwikPen Insulin delivery device

Syringe. Product Usage Information: Precautions:

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

Blood Sampling in Sheep AS-557-W

Agilent High Sensitivity DNA Kit Guide

Helping to protect you from exposure to hazardous drugs

ON-Q * Catheters and Introducers

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

Medications or therapeutic solutions may be injected directly into the bloodstream

To maintain a port of entry to venous flow when all available peripheral ports have failed.

Instructions and User Guide. Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150. June 8, 2011 Rev 2.

DEPARTMENT OF HEALTH PO BOX 358 TRENTON, N.J

Changing Your Central Line Catheter Cap

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

Parent & Healthcare Professional Instructions for the collection of Maternal & Umbilical Cord Blood

The OmniPod Insulin Management System

VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit. For the collection, preservation and purification of RNA from whole blood

EXERCISE 5: ERYTHROCYTES SEDIMENTATION RATE - ESR, SED RATE

The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get

Date effective: Jan 2005 Date revised: June 2015

YOUR GUIDE TO THE LANTUS SOLOSTAR INSULIN PEN

X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Using Insulin Pens and Pen Needles

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company

Blood sampling and transportation Standard Operating Procedure

Blood Tubes and Lancets

A. ADMINISTERING SUBCUTANEOUS MEDICATIONS INTERMITTENTLY/CONTINUOUSLY B. (SUBCUTANEOUS INFUSION) HYDRODERMOCLYSIS

Administration of Meropenem For Child

(English) NEXUS SPINE SPACER SYSTEM

Hemodialysis Access: What You Need to Know

9.0 Components Description SENTIO MMG System Quick Setup Plugging in Control Unit Attaching Sensor Harness

Section 6: Your Hemodialysis Catheter

(800) Cryo-Cell.com

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection

Instructions for Use PROCRIT (PRO KRIT) (epoetin alfa)

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

HUNTER TENDON IMPLANTS

Disposable Insulin Delivery Device User Manual

Slide 1. Welcome to the on-line training course for Waste Management!

14.0 Stem Cell Laboratory Services

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

New 7/1/2015 MCFRS 1

Clinical Guideline for: Aseptic Technique

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

PICC & Midline Catheters Patient Information Guide

Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line)

PRODUCT CATALOGUE RESULTS OF THE SCIENTIFIC PROCESS

Detach Patient's Instructions for Use from package insert and dispense with the product.

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Product Reference Guide

How To Prepare and Give a Prefilled Syringe Injection

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Red rubber all-purpose urethral. Catheters. Bard Clean-Cath Intermittent catheter: Fr. 100/case

The Enbrel SureClick autoinjector is a single-use prefilled autoinjector. It contains one 50-mg dose of Enbrel.

Lab Exercise 3: Media, incubation, and aseptic technique

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

Portex Arterial Blood Sampling Kits

BLOOD BANK SPECIMEN COLLECTION PROCEDURE

Floseal Hemostatic Matrix

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

Reasons for reissue are in Section 6, REVISION SUMMARY.

Achieving Independence. A Guide to Self-Catheterization with the Bard Touchless Plus Intermittent Catheter System

KABEVETTE. Aspiration and Vacuum in one System! The blood collection by KABE LABORTECHNIK KABEVETTE G KABEVETTE V. Aspiration

CATHETER for Hemodialysis

INTERDISCIPLINARY CLINICAL MANUAL Policy and Procedure

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

World Class Equipment worldwide Edition J

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

THE PREPARATION OF SINGLE DONOR CRYOPRECIPITATE

How To Write A Cer

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

Chester Chest Model 2400 User s Manual

INJECTION TECHNIQUE. IVF NURSING OFFICE: (301) Darshana (301) Nicole

A simple guide to using the HumaPen Luxura HD. If you need help with your Pen, call the. HumaPen Luxura HD Help Line:

ProteoMiner Protein Enrichment Kits

SHOT BLAST CABINET MODEL NO: CSB20B

Transcription:

Plasmax Plasma Concentration System BIOLOGICS

Plasmax Plasma Concentration System Plasmax Plasma Concentrate System Contains Plasmax concentrator GPS III separator Provides 16ml of autologous output, 6ml of PRP and 10ml of autologous plasma concentrate Rapidly polymerizing autologous plasma concentrate GPS III generated PRP has nine times more platelets and 5 times more white blood cells then whole blood 1 Consistent/Reproducible Results Utilizes GPS III technology to produce platelet rich plasma Polyacrylamide beads remove excess water from plasma in two minutes Safe Autologous end products Eliminates concerns regarding pooled blood sources Whole Blood Input Platelet Rich Plasma Output Platelet Poor Plasma Input Plasma Concentrate Output Plasmax Concentration System (800-0516) 30ml 3ml 15ml 6ml Plasmax Plus Concentration System (800-0517) 60ml 6ml 25ml 10ml Note: Refer to package inserts for more detailed descriptions

Platelet Rich Plasma (PRP) and Platelet Poor Plasma (PPP) Preparation with GPS III System Technique describes Plasmax Plus Concentration System (800-0517) Step One: Load Remove discard cap and green packaging post on center port (No 1). Slowly load blood-filled 60ml syringe (5ml of citrate anticoagulant and 55ml of blood) into the center port (No 1) of the GPS III separator. Remove and discard protective cover on tethered white cap. Screw white cap onto center port (No 1). Place GPS III separator into centrifuge. Fill the blue GPS III counterbalance (800-0508) with 60 65ml of sterile saline and place into the opposite side of the centrifuge.

Platelet Rich Plasma (PRP) and Platelet Poor Plasma (PPP) Preparation with GPS III System Technique describes Plasmax Plus Concentration System (800-0517) Step Two: Spin Close the lid and set speed for 3200 RPM and timer to 15 minutes. Press green button to start spin. Step Three: PPP and PRP Extraction Once spin is complete, remove yellow cap (No 2). Invert the tube and withdraw 25ml of PPP (No. 2) with a sterile 30ml syringe. Replace yellow cap. Remove red cap on side port No. 3 and connect sterile 10ml syringe. Withdraw 2ml.

Platelet Rich Plasma (PRP) and Platelet Poor Plasma (PPP) Preparation with GPS III System Technique describes Plasmax Plus Concentration System (800-0517) Step Three: PPP and PRP Extraction (Continued) With 10ml syringe attached, suspend the platelets by gently shaking the tube for 30 seconds. Extract the remaining platelet rich plasma (PRP) into the attached 10ml syringe.

Platelet Poor Plasma (PPP) Concentration with Plasmax Concentrator Technique describes Plasmax Plus Concentration System (800-0517) Step Four: Load Plasma Unscrew yellow cap on port No. 1 of Plasmax Plus concentrator and fill with 25ml of PPP. Replace cap (800 0517). Remove and discard protective cover on tethered white cap. Screw white cap onto port No 1. Spin paddle by hand until plasma is fully mixed into beads. Mixing is complete when the white beads are completely saturated with plasma. Note: While spinning, piston the paddle, be sure to push it firmly against the bottom to ensure adequate mixing.

Platelet Poor Plasma (PPP) Concentration with Plasmax Concentrator Technique describes Plasmax Plus Concentration System (800-0517) Step Five: Spin Place Plasmax Plus (800 0517) concentrator into centrifuge with the empty Plasmax Plus counterbalance (800 0512). They should be placed on opposite sides in the centrifuge. Spin for 2 minutes at 2000 RPM. Step Six: Extraction of Plasmax After the spin, the Plasmax Plus concentrator contains approximately 10ml of autologous plasma concentrate. Unscrew red cap on port No. 2. Connect sterile 10ml syringe on port No. 2 and extract approximately 10ml of concentrated plasma.

GPS III Platelet Concentrate Quality Platelet Concentrate From a small volume of a patient s blood, the GPS III System provides a high quality platelet concentrate in an efficient manor. Ease of Use Load blood, spin, extract platelet concentrate. Kits contain all components needed to process platelet concentrate no searching for individual items. Safety Patient s own blood is used. Blood taken at point-of-care. Small volume of blood required (27 110ml). Ordering Information Part No. Description 800-0516 Plasmax Plasma Concentrate Kit 800-0517 Plasmax Plus Plasma Concentrate Kit 755VES Centrifuge 115 volt 50 60 Hz (Table Top) 800-0508 GPS Counterbalance (Blue) 800-0512 Plasmax Plus Concentrator Counterbalance 800-0510 Plasmax Concentrator Counterbalance 800-0250 Spray Applicator Kit (Tip not included) 800-0201 Dual Spray Applicator Tip 800-0202 Malleable Dual Cannula Tip 20 Gauge x 4 Length 800-0203 Malleable Dual Cannula Tip 20 Gauge x 7 Length 800-0206 Malleable Dual Cannula Tip 20 Gauge x 10 Length 800-0204 Blending Connector Tip Single Cannula 800-0260 Aerosol Spray Kit with Tip 800-0211 Aerosol Regulator w/o vent 800 0215 Endoscopic Aerosol Venting Regulator 800 0208 Rigid Dual Cannula Aerosol Tip 5mm dia. x 16 Length (Tubing Included) 800 0216 Rigid Dual Cannula Tip 5mm dia x 12 Length 800-0207 Malleable Dual Lumen Endoscopic Tip 5mm dia. x 12 Length

Biomet Biologics, Inc. 01-50-1448 P.O. Box 587 Date: 03/07 56 E. Bell Drive Warsaw, Indiana 46581 USA Plasmax Plasma Concentrator Accessory used with GPS III Mini Platelet Concentrate Separation Kit with ACD-A ATTENTION OPERATING SURGEON NOTE: FOR SINGLE USE ONLY. Discard the entire disposable kit after one use, using acceptable disposal method for potentially contaminated blood products. DESCRIPTIONS Plasmax Plasma Concentrator Accessory The Plasmax Plasma Concentrator Accessory aids in the concentration of the patient s own plasma proteins by centrifugation utilizing a Biomet Biologics centrifuge. Excess water is removed from the platelet-poor-plasma (PPP) with desalting beads. GPS III Mini Platelet Concentrate Separation Kit with ACD-A The GPS III Mini Platelet Concentrate Separation Kit with ACD-A aids separation of the patient s own blood components by density through the use of a Biomet Biologics centrifuge. MATERIALS The Plasmax Plasma Concentrator Accessory consists of medical grade polymers suitable for the use in medical devices, and contains porous polyacrylamide desalting beads. The GPS III Mini Platelet Separation Kit with ACD-A includes syringes, needles, tubing, connectors, and platelet separators which also consist of medical grade polymers, elastomers and stainless steels suitable for use in medical devices. Blood-draw components in this kit are packaged, labeled and sterilized as indicated by the manufacturer s labeling. All components in this kit are latex-free. ACD-A is an anticoagulant supplied by Citra Anticoagulants, Inc., Braintree, MA, and manufactured by Cytosol Laboratories, Inc., Braintree, MA. For further information regarding ACD-A, please contact the supplier at 1-800- 299-3411. syringe (3ml of ACD-A mixed with 27ml of patient s whole blood) into center blood port #1. Unscrew and discard clear protective inner piece from white cap tethered to port #1. Screw white cap onto port #1. Place platelet separator filled with anticoagulated blood in a Biomet Biologics centrifuge. 3. BALANCE: Fill purple GPS Mini counterbalance tube (800-0505) with 30ml of sterile saline/ water (equal to the amount of whole blood plus ACD-A dispensed in the platelet separator). Place filled counterbalance directly opposite from the platelet separator in the centrifuge. 4. SPIN: Close centrifuge lid. Set RPM to 3.2 (x 1,000) and the time to 15 minutes. Press the start button. Once spin is complete, open centrifuge. 5. EXTRACT PPP: Unscrew yellow cap on port #2, and save yellow cap. Connect 30ml syringe to port #2, invert platelet separator, and extract exactly 15ml of PPP. Remove 30ml syringe from port #2, cap with a sterile syringe cap, and set aside. Replace yellow cap on port #2. 6. If PRP is desired, follow steps 7 8. 7. SUSPEND PRP: Holding platelet separator in the upright position, unscrew red cap on port #3. Attach a 10ml syringe to port #3. Extract 1ml of PRP in the 10ml syringe. Leave the 10ml syringe attached to port #3. Shake platelet separator gently for 30 seconds. 8. EXTRACT PRP: Immediately after suspending the platelets, extract remaining PRP into the attached 10ml syringe. Remove 10ml syringe from port #3, and cap with a sterile syringe cap. PROCEDURE TWO: Use the Plasmax Plasma Concentrator Accessory to prepare PPPc. 1. LOAD: Unscrew cap on port #1. Slowly load the 15ml PPP collected in 30ml syringe into port #1. Unscrew and discard clear, protective inner piece from white cap tethered to port #1. Screw white cap onto port #1. 2. MIX: Twist and piston the mixing paddle for 30 seconds. Be sure to push and twist the paddle to the floor of the Plasmax Plasma Concentrator Accessory s upper chamber to saturate the beads. There should be no white beads visible. Place into centrifuge. 3. BALANCE: Place the green Plasmax counterbalance (800-0510) directly opposite from the Plasmax Plasma Concentrator Accessory in the centrifuge. 4. SPIN: Close centrifuge lid and set RPM to 2.0 (x 1,000) and the time to 2 minutes. Press the start button. Once spin is complete, open centrifuge. 5. EXTRACT PPPc: Unscrew red cap on port #2 and extract PPPc using a sterile 10ml syringe. Remove 10ml syringe from port #2, and cap with a sterile syringe cap. Caution: Federal law (USA) limits this device to sale or use by or on the order of a physician. Comments regarding this device can be directed to Attn: Regulatory Dept., Biomet, P.O. Box 587, Warsaw, IN 46581 USA, FAX: 574-372-1683. GPS is a registered trademark of Biomet Manufacturing Corp. in the United States. The ACD-A included in this kit is only for use with the Plasmax Plasma Concentrator Accessory used with GPS III Mini Platelet Concentrate Separation Kit. INDICATIONS The Plasmax Plasma Concentrator with GPS III Mini Platelet Concentrate Separation Kit with ACD-A is designed to be used for the safe and rapid preparation of concentrated platelet-poorplasma (PPPc) and autologous platelet- rich-plasma (PRP) from a small sample of blood at the patient s point of care. The PPPc and PRP can be mixed with autograft and allograft bone prior to application to an orthopedic surgical site as deemed necessary by the clinical use requirements. CONTRAINDICATIONS 1. Use as a dialyzer or for dialysis with a dialysate. 2. Direct connection to patient s vascular system of circulating blood volume. WARNINGS AND PRECAUTIONS 1. Use proper safety precautions to guard against needle sticks. 2. Follow manufacturer instructions when using the centrifuge. Use only Biomet Biologics centrifuges (GPS IEC centrifuge or Drucker Company centrifuge). Outcomes using centrifuges from other manufacturers are unknown. 3. Do not use sterile components of this kit if package is opened or damaged. 4. Single use device. Do not reuse. 5. The surgeon is to be thoroughly familiar with the equipment and the surgical procedure prior to using this device. 6. The patient is to be made aware of the general risks associated with treatment and possible adverse effects. 7. Use prepared PPPc and PRP within 4 hours after drawing blood from patient, according to current AABB guidelines. 8. The safety and effectiveness for bone healing and hemostasis have not been established. POSSIBLE ADVERSE EFFECTS 1. Damage to blood vessels, hematoma, delayed wound healing and/or infection. 2. Temporary or permanent nerve damage that may result in pain or numbness. 3. Early or late postoperative infection. STERILITY The Plasmax Plasma Concentrator Accessory and the GPS III Mini Platelet Separator are sterilized by exposure to a minimum dose of 25 kgy gamma radiation. All other components supplied in this kit are sterilized by the respective suppliers using radiation or ethylene oxide gas (ETO). Do not re-sterilize. Do not use after expiration date. INSTRUCTIONS FOR USE NOTE: Use standard aseptic technique throughout the following procedures. PROCEDURE ONE: Use the GPS III Mini Platelet Concentrate Separation Kit with ACD-A to prepare platelet-poor-plasma (PPP) and PRP. 1. DRAW: Draw 3ml of ACD-A into 30ml syringe. Attach to 18-gauge apheresis needle and prime with ACD-A. Slowly draw 27ml of patient s own blood into the 30ml syringe primed with ACD-A. Gently, but thoroughly, mix the whole blood and ACD-A upon collection to prevent coagulation. 2. LOAD: ENSURE BLOOD FROM ONLY ONE PATIENT IS PROCESSED PER SPIN, and that the platelet separator remains upright. Unscrew clear cap on center blood port #1. Remove and discard cap and green packaging post. Slowly load blood-filled 30ml The information contained in this package insert was current on the date this brochure was printed. However, the package insert may have been revised after that date. To obtain a current package insert, please contact Biomet at the contact information provided herein.

Biomet Biologics, Inc. 01-50-1456 P.O. Box 587 Date: 03/07 56 E. Bell Drive Warsaw, Indiana 46581 USA Plasmax Plus Plasma Concentrator Accessory used with GPS III Platelet Concentrate Separation Kit with ACD-A ATTENTION OPERATING SURGEON NOTE: FOR SINGLE USE ONLY. Discard the entire disposable kit after one use, using acceptable disposal method for potentially contaminated blood products. DESCRIPTION Plasmax Plus Plasma Concentrator Accessory The Plasmax Plus Plasma Concentrator Accessory aids in the concentration of the patient s own plasma proteins by centrifugation, utilizing a Biomet Biologics centrifuge. Excess water is removed from the platelet-poor-plasma (PPP) when mixed with desalting beads. GPS III Platelet Concentrate Separation Kit with ACD-A The GPS III Platelet Concentrate Separation Kit with ACD-A aids separation of the patient s own blood components by density through the use of a Biomet Biologics centrifuge. MATERIALS The Plasmax Plus Plasma Concentrator Accessory consists of medical grade polymers suitable for the use in medical devices, and contains porous polyacrylamide desalting beads. The GPS III Platelet Concentrate Separation Kit with ACD-A includes syringes, needles, tubing, connectors, and platelet separators which consist of medical grade polymers, elastomers and stainless steels suitable for use in medical devices. Blood-draw components in this kit are packaged, labeled and sterilized as indicated by the manufacturer s labeling. All components in this kit are latex-free. ACD-A is an anticoagulant supplied by Citra Anticoagulants, Inc., Braintree, MA, and manufactured by Cytosol Laboratories, Inc., Braintree, MA. For further information regarding ACD-A, please contact the supplier at 1-800-299-3411. and discard clear protective inner piece from white cap tethered to port #1. Screw white cap onto port #1. Place platelet separator filled with anticoagulated blood in a Biomet Biologics centrifuge. 3. BALANCE: Fill blue GPS counterbalance tube (800-0508) with 60ml of sterile saline/water (equal to amount of whole blood plus ACD-A dispensed in the platelet separator). Place filled counterbalance directly opposite from the blood-filled platelet separator in the centrifuge. 4. SPIN: Close centrifuge lid. Set RPM to 3.2 (x 1,000) and the time to 15 minutes. Press the start button. Once spin is complete, open centrifuge. 5. EXTRACT PPP: Unscrew yellow cap on port #2, and save yellow cap. Connect 30ml syringe to port #2, invert platelet separator, and extract exactly 25ml of PPP. Remove 30ml syringe from port #2, cap with a sterile syringe cap, and set aside. Replace yellow cap on port #2. 6. If PRP is desired, follow steps 7 8. 7. SUSPEND PRP: Holding platelet separator in the upright position, unscrew red cap on port #3. Attach a 10ml syringe to port #3. Extract 2ml of PRP in the 10ml syringe. Leave the 10ml syringe attached to port #3. Shake platelet separator gently for 30 seconds. 8. EXTRACT PRP: Immediately after suspending the platelets, extract remaining PRP into the attached 10ml syringe. Remove 10ml syringe from port #3, and cap with a sterile syringe cap. PROCEDURE TWO: Use the Plasmax Plus Plasma Concentrator Accessory to prepare PPPc. 1. LOAD: Unscrew cap on port #1. Slowly load the 25ml PPP collected in 30ml syringe into port #1. Unscrew and discard clear, protective inner piece from white cap tethered to port #1. Screw white cap onto port #1. 2. MIX: Twist and piston the mixing paddle for 30 seconds. Be sure to push and twist the paddle to the floor of the Plasmax Plus Plasma Concentrator Accessory s upper chamber to saturate the beads. There should be no white beads visible. Place into centrifuge. 3. BALANCE: Place the green Plasmax Plus counterbalance (800-0512) directly opposite from the Plasmax Plus Plasma Concentrator Accessory in the centrifuge. 4. SPIN: Close centrifuge lid and set RPM to 2.0 (x 1,000) and the time to 2 minutes. Press the start button. Once spin is complete, open centrifuge. 5. EXTRACT PPPc: Unscrew red cap on port #2 and extract PPPc using a sterile 10ml syringe. Remove 10ml syringe from port #2, and cap with a sterile syringe cap. Caution: Federal law (USA) limits this device to sale or use by or on the order of a physician. Comments regarding this device can be directed to Attn: Regulatory Dept., Biomet, P.O. Box 587, Warsaw, IN 46581 USA, FAX: 574-372-1683. GPS is a registered trademark of Biomet Manufacturing Corp. in the United States. The ACD-A included in this kit is only for use with the Plasmax Plus Plasma Concentrator Accessory used with GPS III Platelet Concentrate Separation Kit. INDICATIONS The Plasmax Plus Plasma Concentrator Accessory used with GPS III Platelet Concentrate Separation Kit with ACD-A is designed to be used for the safe and rapid preparation of concentrated platelet-poor-plasma (PPPc) and autologous platelet-rich-plasma (PRP) from a small sample of blood at the patient s point of care. The PPPc and PRP can be mixed with autograft and allograft bone prior to application to an orthopedic surgical site as deemed necessary by the clinical use requirements. CONTRAINDICATIONS 1. Use as a dialyzer or for dialysis with a dialysate. 2. Direct connection to patient s vascular system of circulating blood volume. WARNINGS AND PRECAUTIONS 1. Use proper safety precautions to guard against needle sticks. 2. Follow manufacturer instructions when using the centrifuge. Use only a Biomet Biologics centrifuge (GPS IEC centrifuge or Drucker Company centrifuge). Outcomes using centrifuges from other manufacturers are unknown. 3. Do not use sterile components of this kit if package is opened or damaged. 4. Single use device. Do not reuse. 5. The surgeon is to be thoroughly familiar with the equipment and the surgical procedure prior to using this device. 6. The patient is to be made aware of the general risks associated with treatment and possible adverse effects. 7. Use prepared PPPc and PRP within 4 hours after drawing blood from patient, according to AABB guidelines. 8. The safety and effectiveness for bone healing and hemostasis have not been established. POSSIBLE ADVERSE EFFECTS 1. Damage to blood vessels, hematoma, delayed wound healing and/or infection. 2. Temporary or permanent nerve damage that may result in pain or numbness. 3. Early or late postoperative infection. STERILITY The Plasmax Plus Plasma Concentrator Accessory and the GPS III platelet separator are sterilized by exposure to a minimum dose of 25 kgy gamma radiation. All other components are sterilized by the respective suppliers using radiation or ethylene oxide gas (ETO). Do not re-sterilize. Do not use after expiration date. INSTRUCTIONS FOR USE NOTE: Use standard aseptic technique throughout the following procedures. PROCEDURE ONE: Use the GPS III Platelet Concentrate Separation Kit with ACD-A to prepare platelet-poor-plasma (PPP) and PRP. 1. DRAW: Draw 5ml of ACD-A into 60ml syringe, attach to 18-gauge apheresis needle and prime with ACD-A. Slowly draw 55ml of patient s own blood into the 60ml syringe primed with ACD-A. Gently, but thoroughly mix the whole blood and ACD-A upon collection to prevent coagulation. 2. LOAD: ENSURE BLOOD FROM ONLY ONE PATIENT IS PROCESSED PER SPIN, and that the platelet separator remains upright. Unscrew clear cap on center blood port #1. Remove and discard cap and green packaging post. Slowly load blood-filled 60ml syringe (5ml of ACD-A mixed with 55ml of patient s whole blood) into center blood port #1. Unscrew The information contained in this package insert was current on the date this brochure was printed. However, the package insert may have been revised after that date. To obtain a current package insert, please contact Biomet at the contact information provided herein.

References 1. Data on file at Biomet Biologics TM, LLC. Bench test results are not necessarily indicative of clinical performance. All trademarks herein are property of Biomet, Inc. or its subsidiaries unless otherwise indicated. This material is intended for the sole use and benefit of the Biomet Biologics sales force and physicians. It is not to be redistributed, duplicated, or disclosed without the express written consent of Biomet. BIOLOGICS P.O. Box 587, Warsaw, IN 46581-0587 800.348.9500 ext. 1501 2008 Biomet Orthopedics www.biomet.com Form No. BBI0020.0 REV061508