Proportional Pressure Relief Valves



Similar documents
Proportional Pressure Reducing Valves

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

KDG3V-5/7/8, 10 Series

Pressure Relief Valves for Pipe Mounting

General Information. Installation Wiring Practices for Vickers Electronic Products

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Pressure Relief. Pressure Relief Valves. Vickers

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

Variable Displacement Pump AA10VSO

Pressure reducing valve, direct operated, Type ZDR 6 D

PVH131/141 Variable Displacement Piston Pump - 11 Design

Duct Humidity Transmitter

SystemStak. SystemStak Valves. Vickers

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Unit 24: Applications of Pneumatics and Hydraulics

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

3/2- and 2/2-way cartridge valve type BVE

3/2 Solenoid Cartridge Valve, Size 6

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Vickers. Piston Pumps

Electro-hydraulic pressure switches type DG

2/2 and 3/2 Way Size 6 Seat Valves

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Features. Picture. Specifications

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

Proportional Directional Control Valves

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Hydraulic Flow Control Valves

Hydraulic Control Solutions

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Directional Controls

Series TMM Axial Piston Motor. Technical Information

Check Valves Valve locator

Pressure transmitter For general industrial applications Model A-10

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Chapter 6: Check Valves

4 Posiflow Proportional Solenoid Valves

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Solenoid Operated Directional Valves

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Proportional pressure regulators VPPE

Solenoid Operated Directional Valves

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Dual Path Mobile Pump

Pressure relief valves Size 6

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Electro-pneumatic control valves

Analog signal converters CC-E I/I Current / current isolators

Telephone- and leased line modem for industrial applications TD-36

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

3/2-way Solenoid Valve, direct-acting, NC or NO

Assisted lift operated 2/2-way solenoid valves Type EV250B

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

Round Housing with Side Ports

Digital inductive conductivity transmitter

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

ST Series POWER SUPPLIES USER INSTRUCTIONS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

ACCUMULATOR INSTALLATION

Example. Fluid Power. Circuits

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Chapter 5: Flow Valves

4/2-Way Pneumatic Solenoid Valve

Pressure Relief and Regulating Valves

Cooling system components, removing and installing

T7560A,B,C Digital Wall Module

Centro-Matic Automatic Lubrication Systems System Controls

Joystick PVRES and PVREL. Technical Information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Redundancy Module QUINT-DIODE/40

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Table of Contents. M Series Variable Displacement Piston Pumps

How To Use A Flowmeter

Troubleshooting Guide for Jacks Down LED Lights

OCTOPUS SELECTION & INSTALLATION GUIDE

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment

Transcription:

Proportional Pressure Relief Valves echnical Catalog KBCG-6-1* KBCG-8-1*

Contents General Description Page 3 ypical Section Page 3 Functional Symbol Page 4 Model Codes Page 5 Operating Data Page 6 Performance Data Pressure Override, Off-Load Page 8 Pressure Override when Relieving Page 9 Pressure Gain Page 9 Step Response Page 9 Installation Dimensions KBCG-6/8 Models Page 10 Mounting Surfaces Page 11 CGVM-6-10-R Subplate Page 11 Electrical Information Block Diagram Page 12 ypical Connection Arrangements Page 13 Further Information Page 14 his product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Wiring practices relevant to this Directive are indicated by Electromagnetic Compatibility (EMC). 2

General Description hese two-stage pressure relief valves offer extensive application possibilities through their ability to control the pressure setting in proportion to an applied electrical input (up to a pressure limit which is manually adjustable and lockable). he integral amplifier allows the pressure to be controlled from a low power command signal: either a voltage or current command. he amplifier is mounted in a robust metal housing and electrical connections are via an industry standard 7-pin plug. Factory-set adjustments ensure high reproducibility valve-to-valve. Basic Characteristics Max. pressure...350 bar (5000 psi) Max. flow rate...400 L/min (106 USgpm) Mounting face to ISO 6264: For KBCG-6... AR-06-2-A For KBCG-8... AS-08-2-A Features and Benefits Remote electrical proportional control of pressure from a choice of five pressure ranges per valve size. Excellent repeatability and stable performance results from cartridge design of mainstage elements. Low installed cost and space requirement from high power/size ratios (more than double that of many conventional designs). On-board ramp adjustment. ypical Section 3

Functional Symbols Manual and electrical pilots internally drained to port. Model code Manual and electrical pilots drained to side drain port. 7 = Blank Model code 7 = 1 7-pin plug 7-pin plug P P Side drain port X P X P apped port on side of pilot head. Manual pilot internally drained to port ; electrical pilot drained to side drain port. Model code 7 = 3 7-pin plug P Side drain port X P apped port on side of pilot head. 4

Model Codes 1 KB - 2 Valve ype Proportional valve with integral amplifier, B series ype C - Pressure relief 3 Mounting G - Subplate mounted 4 Interface - ISO 6264 With B port high pressure inlet, A port reduced pressure outlet 6 - AR-06-2-A 8 - AS-08-2-A 5 Manual Adjustment K - Micrometer with keylock M - Micrometer without keylock W - Screw/locknut 6 Controlled Pressure Range Based on inlet pressure of 350 bar (5000 psi). Note, with 100 bar (1450 psi) inlet the lower limits will be 2-3 bar (30-43 psi) lower 40-6-40 bar (87-580 psi) 100-7,75-100 bar (112-1450 psi) 160-8,5-160 bar (125-2300 psi) 250-8,5-250 bar (125-3625 psi) 350-9-350 bar (139-5000 psi) 7 Drain Blank - Manual and electrical pilots drain internally to port 1 - Manual and electrical pilots drained to side port drain 3 - Manual pilot internally drained to port, electrical pilot drained to side port drain 8 Standard Features ZM - for KBC 9 Electrical Command Options 1 - +/- 10 volts control signal 2-4-20 ma control signal 10 Ramps 3 - Standard ramp for KBCG- 6/8 valve types 11 Command/Pressure Characteristic A - Standard 12 Electrical Connection PC7-7 pin connector, without plug supplied PE7-7 pin connector, with plug supplied PH7 - As PE7 but with pin C used for enable signal PR7 - as PC7 but with pin C used for enable signal 13 Coil Rating H1-24V DC amplifier supply 14 Design Number, 1* Series Subject to change. Installation dimensions unaltered for design numbers 10 to 19 inclusive. Warning o conform to the EC Electromagnetic Compatibility directive (EMC) this KBCG valve must be fitted with a metal 7-pin plug. he screen of the cable must be securely connected to the shell of the metal connector. A suitable IP67 rated connector is available from Eaton, part no. 934939. Alternatively a non IP67 rated connector is available from I-Cannon, part no. CA 02 COM-E 14S A7 P. 5

Operating Data Standard test conditions are with antiwear hydraulic oil at 36 cst (168 SUS) and 50 C (122 F) Maximum pressures: Ports P and X 350 bar (5000 psi) Port in KBCG-*-****-Z valves 2 bar (30 psi) Port in KBCG-*-****-1/3-Z valves 350 bar (5000 psi) Side drain port 2 bar (30 psi) Back pressure at these ports additive to the pressure setting of the valve. Rated flow at p = 6 bar (87 psi): KBCG-6 200 L/min (52.8 USgpm) KBCG-8 400 L/min (105.7 USgpm) Vent flow with valve at rated flow 1 L/min (0.26 USgpm) See Venting, page 8. Pilot control drain flow, when valve is limiting system pressure, i.e. flow P to occurring: KBCG-6 1,3 L/min (0.34 USgpm) KBCG-8 2,0 L/min (0.53 USgpm) Coil or amplifier rating 24V x 40W max. (22 to 36V including 10% pk.-to-pk. max. ripple) Command signal: Volts (see model code 9-1) 0 to +10V or 0 to -10V Input impedance 47 kω Common mode voltage to pin B 4V Current (see model code 9-2) 4 to 20 ma Input impedance 100Ω Valve enable signal: Enable >9.0V (36V max) Disable <2.0V Input impedance 36 kω 7-pin plug connector Pin Description A G A Power supply positive (+) F B B Power supply 0V and current command return C Valve enable (PH7 & PR7) E C D Command signal (+V or current in) E Command signal (-V or current GND) D F Output monitor View of pins of fixed half G Protective ground Electromagnetic compatibility (EMC): Emission (10 V/m) EN 50081-2 Immunity (10 V/m) EN 50082-2 Monitor signal (pin F) 1.7 V/amp solenoid current Output impedance 10 kω Pressure gain See graph Factory setting - Maximum with 100% command signal. Pressure override when relieving and when off-load See graphs Linearity, between 10% and 100% of rated pressure: KBCG-6 models at 100 L/min (26 USgpm) <6% KBCG-8 models at 200 L/min (52 USgpm) <6% Hysteresis <6% (with factory-set dither) Repeatability <1.3% of rated pressure 6

Operating Data (continued) Reproducibility, valve-to-valve (at factory settings): Pressure at 100% command signal 5% Protection: Electrical Reverse polarity protected Environmental IEC 529, Class IP67 Mass (weight): KBCG-6 5,36 kg (11.8 lb) KBCG-8 6,26 kg (13.8 lb) Supporting products: Auxiliary electronic modules (DIN-rail mounting): EHA-CON-201-A-2* Signal converter See catalog 2410B EHD-DSG-201-A-1* Command signal generator See catalog 2470 EHA-RMP-201-A-2* Ramp generator See catalog 2410B EHA-PID-201-A-2* PID controller See catalog 2427 EHA-PSU-201-A-10 Power supply See catalog 2410B Subplates, size 03 See catalog 2425 Mounting bolts See catalog 2314A Note: If not using Vickers recommended bolt kits, bolts must be to ISO 898 grade 12.9 or stronger. Mounting attitude No restriction, provided that the valve is kept full of fluid through port. 7

Performance Data Data is typical with oil at 36 cst (168 SUS) and at 50 C (122 F) Pressure Override, Off-Load KBCG-6 psi bar Graphs show the minimum pressures obtainable: a) With 0 ma current to the solenoid coil b) When the valve is vented (see following explanation). Venting When the vent port X (or alternative vent port in the valve body) is connected to the reservoir via a suitable 2-way pilot valve, the mainstage of the relief valve opens to allow full flow from P to at low pressure drop. he minimum pressure drop is obtained when the pilot valve is also deenergized. he total pressure drop through the venting 2-way valve and pipework is additive to the pressure at P. While the valve is vented the system pressure cannot be controlled via the proportional solenoid. his control feature is frequently used during off-load periods in machine cycle times. If lower off-load system pressures are required then additional full flow unloading valves are recommended, e.g. Vickers CV series cartridge valves. Note: All valves are with pilot valve de-energized. Valve pressure drop Valve pressure drop 150 125 100 75 50 25 0 KBCG-8 psi 150 125 100 75 50 25 0 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 L/min 0 10 20 30 40 50 USgpm Flow rate bar 10 9 8 7 6 5 4 3 2 1 0 KBCG-8*-350 KBCG-8*-100 KBCG-8*-160/250 100 KBCG-6*-160/250/350 KBCG-6*-100 KBCG-6*-40 (also KBCG-6*-350 vented) KBCG-6*-40 vented KBCG-8*-40 (also KBCG-8-350 vented) KBCG-8*-40 vented 200 300 400 L/min 0 20 40 60 80 Flow rate 100 USgpm 8

Pressure Override when Relieving psi 5000 bar 350 9 Pressure 4000 3000 2000 1000 300 250 200 150 100 50 8 7 6 5 4 3 2 1 MODEL 0 KBCG-8 KBCG-6 0 0 100 200 300 400 L/min 0 20 40 60 80 100 USgpm 0 40 80 120 160 200 L/min 0 10 20 30 40 50 USgpm Flow rate CURVE NUMBER 1 2 3 4 5 6 7 8 9 KBCG-**-40 KBCG-**-100 KBCG-**-160 KBCG-**-250 KBCG-**-350 Pressure Gain ypical pressure versus command signal response of KBCG-6-250 model. Pressure psi 4000 3000 2000 1000 bar 300 250 200 150 100 50 0 0 10 20 30 40 50 60 70 80 90 100% % max. solenoid current Step Response KBCG models with factory-set gain. est method 1. rapped volume between pump and test valve, as in table. 2. Flow rate set at pump, as in table. 3. Response = time from step input signal until pressure reaches 90% of step change, as measured by transducer. VALVE SIZE ES CONDIIONS: SEP SIZE: RESPONSE RAPPED VOLUME FLOW RAE PRESSURE DEMAND IME (ms) 6 2,0 liters 100 L/min 0 to 100% 100 (0.53 USg) (26 USgpm) 100% to 0 70 25 to 100% 40 100 to 25% 50 8 4,0 liters 200 L/min 0 to 100% 110 (1.06 USg) (52 USgpm) 100% to 0 70 25 to 100% 50 100 to 25% 65 9

Installation Dimensions KBCG-6/8 Models Dimensions are shown in mm (inches) o bleed air, loosen plug in end of core tube; re-tighten to 2,4 +/- 0,2 Nm (1.85 +/- 0.15 lbf ft) after bleeding is complete. 20,0 (0.79) for connector removal 196,5 (7.74) 203,0 (8.12) for KBCG-6 209,0 (8.23) for KBCG-8 3rd angle projection Side drain port G 1 /4 ( 1 /4" BSPF) (see "Functional Symbols" section) A A L 77,5 (3.1) Locknut 17,0 (0.67) A/F 16,0 (0.63) Micrometer Adjustment Options "K" or "M" in Model Code ype K only: 43,0 (1.7) for key removal 7,5 (0.29) A/F urn clockwise to increase pressure setting 45,0 (1.8) for removal of protective cap E Port outlet to reservoir Port P pressure inlet K C 62 Port X (vent port) G 1 /4 ( 1 /4" BSPF) alternative vent port. Remove plug for access. B D H G A Mainstage overall dimension with adjuster knob fully out: 196,0 (7.7) for KBCG-6 models 203,0 (8.0) for KBCG-8 models "K" Feature: o adjust pressure setting, insert key and turn clockwise. urn micrometer knob clockwise to increase pressure setting; counter-clockwise to decrease setting. When the key is removed the knob can spin freely without affecting the pressure setting. Warning o conform to the EC Electromagnetic Compatibility directive (EMC) this KBCG valve must be fitted with a metal 7-pin plug. he screen of the cable must be securely connected to the shell of the metal connector. A suitable IP67 rated connector is available from Eaton, part no. 934939. Alternatively a non IP67 rated connector is available from I-Cannon, part no. CA 02 COM-E 14S A7 P. J View "A-A" MODEL A B C D E RAD ØF (DIA) KBCG-6 58,0 35,0 68,0 35,0 12,0 20,0 (2.3) (1.4) (2.7) (1.4) (0.5) (0.78) KBCG-8 42,0 39,0 83,0 30,0 16,0 26,0 (1.7) (1.54) (3.3) (1.2) (0.63) (1.02) MODEL G H ØJ (DIA) K L KBCG-6 79,0 82,0 13,5 176,0 20,0 (3.1) (3.23) (0.53) (7.0) (0.78) KBCG-8 103,0 106,0 17,0 183,0 25,0 (4.1) (4.2) (0.7) (7.2) (1.0) F 10

Installation Dimensions (continued) Mounting Surfaces, ISO 6264 AR-06-2-A AS-08-2-A When a subplate is not used, a raised pad must be provided for mounting. he pad must be flat within 0,001 mm/100 mm (0.0001 /10 ) and smooth within 0,8 µm (32 µin). Dimensional tolerances are ±0,2 mm (±0.008 ) except where indicated. Port functions: P = Pressure inlet = Outlet to reservoir X = Vent, or remote control port M (min.) L N B (min.) X J A (min.) C E F H K (min.) Y Plug or omit if this vent / hydraulic remote port is not to be used P D (min.) Ø 7,5 (0.29 dia) x 6,0 (0.24) deep min. SIZE A B C D E F H J K L AR-06 80 (3.2) 13,1 (0.5) 53,8 (2.12) 13,1 (0.5) 47,5 (1.87) 22,1 (0.87) 22,1 (0.87) 0 13,1 (0.5) 53,8 (2.12) AS-08 118 (4.7) 35,0 (1.4) 66,7 (2.63) 16,3 (0.7) 55,6 (2.19) 33,4 (1.35) 11,1 (0.44) 23,8 (0.94) 16,0 (0.63) 70,0 (2.76) SIZE M N ØP (DIA) Q Ø (DIA) ØX (DIA) Y HREAD x MIN. FULL HREAD DEPH AR-06 13,1 (0.5) 26,9 (1.06) 14,7 (0.58) 80 (3.2) 14,7 (0.58 4,8 (0.19) M12 x 21 (7/16 UNF x 0.83) AS-08 16,0 (0.63) 35,0 (1.38) 23,4 (0.92) 102 (4.0) 23,4 (0.92) 6,3 (0.25) M16 x 30 (5/8 UNF x 1.2) Q (min.) olerance on bolt and pin locations ±0,1 mm (±0.004 ). hese ISO standard dimensions can be used, but improved flow paths to and from valve are obtained by using 48,0 (1.89) instead of 47,5 (1.87), and 22,6 (0.89) instead of 22,1 (0.87). ISO standard does not give UNC bolt sizes. hese are recommended equivalents to metric sizes specified in the standard. CGVM-6-10-R Subplate 4 holes, Ø 11,0 (0.43 dia) through, Ø 17,5 (0.68 dia) spotface Ø 7,5 (0.29 dia) x 6,0 (0.24) deep, for valve locating pin 125,0 (5.0) 56,0 (2.2) G 1 /4 ( 1 /4" BSPF) x 12,0 (0.47) min. depth full thread, from underside 21,0 (0.83) 7,0 (0.27) 21,7 (0.85) 20,0 (0.79) 55,0 (2.2) 80,0 (3.15) P X 26,9 101,0 (1.06) (4.0) 68,5 (2.7) 2 ports, G1 (1" BSPF) x 19,0 (0.75) min. depth full thread, from underside 132,0 (5.2) 150,0 (6.0) 24,0 (0.95) 4 holes tapped M12 x 21,0 (0.82) min. depth full thread 11

Electrical Information Block Diagram Command signal 7-pin plug connections +24V Power 0V Enable Non-inverting Inverting Current monitor A B C D E F Protective ground G +24V +5V Ramp Gain PWM modulator Wiring Connections must be made via the 7-pin plug mounted on the amplifier. See this leaflet and Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Recommended cable sizes are: Power Cables For 24V supply: 0,75 mm 2 (18 AWG) up to 20m (65 ft) 1,00 mm 2 (16 AWG) up to 40m (130 ft) Signal Cables 0,50 mm 2 (20 AWG) In valves with PH7 or PR7 type electrical connection. Solenoid drive Screen (Shield) A suitable cable should have at least 6 cores with pairs of conductors individually screened and an overall screen. Cable outside diameter 8,0-10,5 mm (0.31-0.41 inches). See connection diagrams on next page. Warning All power must be switched off before connecting or disconnecting any plugs. 12

ypical Connection Arrangements Wiring Connections User Panel Power Supply Demand Signal Solenoid Current Monitor 0V +/-10V Outer Screen +24V A 0V B 0V Input Inner Screen Drain Wire KB..PC7/PE7 valve C D or E E or D G F Valve must be connected to ground via subplate Pin C may be connected to ground or left unconnected. Output monitor voltage (pin F) will be referenced to the power 0 volts (pin B). Enclosure 0V must be connected to ground Connector shell Wiring Connections for Valves with Enable Feature User Panel Power Supply Enable Signal Demand Signal Solenoid Current Monitor Outer Screen +24V A 0V B 0V +8.5V to 36V 0V Input Inner Screen Drain Wire KB..PR7/PH7 valve C D or E E or D G F Valve must be connected to ground via subplate Note: In applications where the valve must conform to European RFI/EMC regulations, the outer screen (shield) must be connected to the outer shell of the 7-pin connector, and the valve body must be fastened to the earth ground. Proper earth grounding practices must be observed in this case, as any differences in command source and valve ground potentials will result in a screen (shield) ground loop. 0V must be connected to ground Warning Electromagnetic Compatibility (EMC) It is necessary to ensure that the valve is wired up as above. For effective protection the user electrical cabinet, the valve subplate or manifold and the cable screens should be connected to efficient ground points. he metal 7-pin connector part no. 934939 should be used for the integral amplifier. In all cases both valve and cable should be kept as far away as possible from any Connector shell sources of electromagnetic radiation such as cables carrying heavy current, relays and certain kinds of portable radio transmitters, etc. Difficult environments could mean that extra screening may be necessary to avoid the interference. It is important to connect the 0V lines as shown above. he multi-core cable should have at least two screens to separate the demand signal and monitor output from the power lines. 13

Further Information Hydraulic Fluids Materials and seals used in these valves are compatible with: Anti-wear petroleum oils...l-hm Non-alkyl based phosphate esters...l-hfd he extreme operating range is 500 to 13 cst (270 to 70 SUS) but the recommended running range is 54 to 13 cst (245 to 70 SUS). For further technical information about fluids see 694. Contamination Control Requirements Recommendations on contamination control methods and the selection of products to control fluid condition are included in publication 9132 or 561, Guide to Systemic Contamination Control. he book also includes information on the concept of ProActive Maintenance. he following recommendations are based on ISO cleanliness levels at 2 µm, 5 µm and 15 µm. For products in this catalog the recommended levels are: Up to 210 bar (3000 psi)...18/16/13 Above 210 bar (3000 psi)...17/15/12 Installation and Start-up Guidelines he proportional valves in this catalog can be mounted in any attitude but it may be necessary, in certain demanding applications, to ensure that the solenoids are kept full of hydraulic fluid. If this proves to be the case any accumulated air can be bled from the solenoid bleed screw. his task is easier if the valve has been mounted base downwards. Good installation practice dictates that the tank port, and any drain port, are piped so as to keep the valve full of fluid once the system start-up has been completed. emperatures For petroleum oil: Min...-20 C (-45 F) Max...+70 C (158 F) For fluids where limits are outside those of petroleum oil, consult fluid manufacturer or Eaton representative. Whatever the actual temperature range, ensure that viscosities stay within those specified under Hydraulic Fluids. Ambient for: Valves at full performance specification: -20 to +70 C (-4 to +158 F). Valves, as above, will operate at temperatures of 0 to -20 C (32 to -4 F) but with a reduced dynamic response. Storage: -25 to +85 C (-13 to +185 F) Seal Kits Pilot valve: KBCG-3...02-352521 Mainstage valves: KBCG-6...614824 KBCG-8...614931 14

Eaton 14615 Lone Oak Road Eden Prairie, MN 55344-2287 USA el: (+1) 952 937-9800 Fax: (+1) 952 974-7722 www.hydraulics.eaton.com Eaton 20 Rosamond Road Footscray Victoria 3011 Australia el: (+61) 3 9319 8222 Fax: (+61) 3 9318 5714 Eaton Dr.-Reckeweg-Str. 1 D-76532 Baden-Baden Germany el: +49 (0) 7221 682-0 Fax: +49 (0) 7221 682-788 2003 Eaton Corporation All Rights Reserved Printed in USA Document No. V-VLPO-MC003-E May 2003