Instruction Manual Crane Scales PCE-HS Series



Similar documents
Operating instructions Platform/floor scales

OCS-S High Resolution Digital Crane Scale

OCSM Series. High Resolution Digital Crane Scale. User Guide

BW-500 BED WEIGHER USER MANUAL

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Hygro-Thermometer + InfraRed Thermometer Model RH101

Ron 3025 Crane Scale with 1"/25mm Display

Operating Manual Electronic Wheelchair Scale with cable display M50610

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

Ground Resistance Clamp On Tester

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

My Weigh Ultraship Series User Manual

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

BODY FAT & HYDRATION % MONITOR SCALE

Portable Air Conditioner

OCS-XZ-C Series User s Guide. OCS-XZ Series Electronic Crane Scale. User s Guide - 1 -

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

4-Channel Thermometer / Datalogger

Integrating Sound Level Meter and Datalogger

High precision counting scale. Operation Manual. l RCZ-A Series

Model 349KLX Remote Display Digital Scale User Instructions

EnergySmart monitor user instructions

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Manual Ranging MultiMeter

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

- 2 - IMPORTANT SAFETY REMINDERS

EVBIKE LCD Display Control User Guide. EVBIKE LCD Display Control User Guide

Light Meter (Foot Candles)

BASIC BODY COMPOSITION SCALE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Electronic Pressure Switch EDS 300

Thermistor Thermometer MODEL NO

Operating Manual Remote Cost Control Monitor

QUANTUM. Body Composition Scale. 330lb x 0.2lb 150kg x 0.1kg

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

How To Use A Meter

Advanced Systems Tester 900AST

DAB+ / FM Tuner Model: TU-201

Product Information Sheet UH28CS-12kV Hi Pot Tester

Body Fat Scale Instructions for use

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

Notice. Reverse engineering and disassembly are prohibited.

Phoenix Body Fat Scale Manual

OPERATING INSTRUCTIONS

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

DAB & FM RADIO Installation Manual

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

ExStik TM ph Waterproof Meters

esata External Storage

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

DISSOLVED OXYGEN METER Model : DO-5509

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

User Guide. Body fat scale

Approach Series. owner s manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ph 200 ph-/redox-/temperature Meter Operating instructions

MAGICAR M871A. Car alarm with two-way remote User s guide

Instruction Manual Temp 4/5/6 Temperature Meter Series

MSI3460. User Guide. Measurement Systems International. Challenger 3 Crane Scales

FT-100 Fire Training Fog Machine User Manual English

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

2 Installation Explanation

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

MANUAL TR-110 TR-110

INFRARED QUARTZ WALL HEATER

GREISINGER electronic GmbH

LCD Readout Digital Pressure Switch

XP Series Balances Operation Manual

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

Register your product and get support at LFH0645 LFH0648. EN User manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

User's Guide. Pinless Moisture Meter. Model MO257

AutoRanging Digital MultiMeter

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

EGSTON Standard E2xFxWx 12W

Hand-held thermometer Model CTH7000

DAR-101. GB Version 1

Operating Manual for Adjustable Height Tables. Contact us at or 1

Operating instructions in the back. PD1020L

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

explained... Settings menu What the buttons do

Meaco 30L and Meaco 40L dehumidifier instruction manual

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

Current Monitoring Kit

Transcription:

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 info@pce-instruments.com www.pce-instruments.com/english www.pce-instruments.com Instruction Manual Crane Scales PCE-HS Series

1. Introduction The hanging scale of the PCE-HS series is applied in industrial sectors as well as in private sectors. The scale stands out due to a long life time, a simple design and useful functions. It is delivered as a ready-to-work article, so that you can start as soon as the package has arrived without further ado. Functions of the hanging scale: - Auto ON / OFF Function (can be deactivated) - Various measurement units: kg, lb and N (Newton) - Mode for weighing animals (Filter for moving objects) - Several Hold-functions (Auto-HOLD / Key-HOLD / AUTO-button-HOLD) - Peak-Value indication (PEAK) - Background lights 2.Technical Specifications PCE-HS 50 PCE-HS 150 Maximum load 50 kg 150 kg Minimum load (without indication) 0.20 kg (200 g) 0.50 kg (500 g) Reading Precision ( d ) 0.02 kg (20 g) 0.05 kg (50 g) Tolerance / Accuracy ± 0.08 kg (80 g) ± 0.20 kg (200 g) Overload indication -ooooo- from 50.18 kg from 150.45 kg Tare weight Display Measuring unit For entire measuring range (Multiple-tare performable) LCD backlit (Auto-OFF within 5 sec.) / digit height 19 mm kg / lb / N (Newton) Power Supply 3 x 1.5 V AA batteries (3.6 V 5 V) LO Display (weak battery) Power Consumption Enclosure from 3.4 V ± 0.1 V < 20 ma Synthetics Operation temperature 5 C 35 C Storage temperature 0 C 60 C Weight (incl. hook & carabiner) Adjustment / Calibration linear approx. 400 g 10 kg / 20 kg / 40 kg / 50 kg 40 kg / 80 kg / 120 kg / 150 kg 2

3. Delivery content und montage Please check immediately, after the package has arrived, whether the following items are included. Delivery content: 1x hanging scale PCE-HS series, 1x hook, 1x shackle, batteries and instruction manual. Montage: 1. Please remove the wrapping from the scale. 2. Insert battery into scale. 3. Hang mounting parts into the scale. 4. Precaution The scale may only be plugged into a socket with earth conductors (PE) according to regulations. The protective effect cannot be abolished by using an extension line without earth conductors. In case of voltage supplies from networks without connected earth conductor, a comparable protection according to the effective installation guidelines is to build by a specialist. - In case of operation in surroundings of more strict safety requirements the relevant guidelines are to follow. Use only extension lines with earth conductors. - If the line cord is damaged, the device has to be disconnected from the power network, effective immediately, and the line cord has to be replaced. - If there is any reason to doubt a risk-free operation of the scale, the device has to be disconnected from the power network and safeguarded against accidental operation. - The instruction manual is to be read by every operator and must be always within reach at the workplace. DANGER Do not let any flammable material onto, under or aside the device. Do not operate the scale in possibly explosive areas. Please be cautious to not let any fluids get inside the device or rather into the connections at the back of the device. In case a fluid is spilled onto the device, disconnect the device immediately from the power network. The device may only be reinstated, after inspection by a competent PCE-inst. retail specialist. 4.1 LO = Low battery voltage In case a battery load is lower than 3.4 V ± 0.1 V, the scale will indicate an error indication LO at the display. Then the batteries should be replaced. You will require three 1.5 V AA batteries. 3

4.2 ooooo = overload If the scale is loaded above its maximum range, the display will indicate ooooo (see table). Please unload the scale and check it afterwards. That error indication may also occur, if the calibration of the scale is wrong and the scale assumes to be overloaded. Please perform a calibration of the scale then. 5. Disposal To implement the RoHS (redemption and disposal of electric devices) we take back our devices. They will either be recycled by us or be disposed through a recycling company according to statutory provisions (WEEE-Reg.-Nr. DE69278128 ) 6. Operation 6.1. Starting the scale In order to start the scale, please press the button at the control panel. The scale will first shortly activate all segments of the display (1 st image) and will show than which HOLD-functions are activated (2 nd image shows HOLD-KEY). Then the scale will automatically skip to the scaling mode (3 rd image) and the scaling can be started. Since the scale only indicates weights above 10 d (compare with table minimum load ) it may occur that later on these values will lead to fault measurements. We advise to press previous to every weighing the button to delete the values that cannot be indicated anyway. 6.2. Tare function The scale features a tare function, e.g. in order to subtract packages from the gross weight. - Therefore hang the empty container onto the scale, so it will only indicate the weight of that package. - Press then the button, so that the display will show again. - You can also use the tare - function repeatedly (multiple tare). The range for the tare function of the scale covers the entire weighing range. But please consider that the weighing range of the scale cannot be extended with that function. For example, if you have the 50 kg scale and you use the tare function with a container of 5 kg, you will only have a total weighing range of 45 kg left. So if the maximum weighing range is exceeded, the display will indicate the 4

following error notice: 6.3. Measuring unit UNIT The scale can perform measurements in kg (kilogram), in lb (pound) and N (Newton). The measuring unit is indicated at the right corner of the display. The unit switch is installed at the ba ck of the scale. The unit that is set will remain active as long as you do not switch to the next unit. 1 kg = 1000 g 1 kg = 2.204 lb 1 kg = 9.81 N 6.4. AUTO Power OFF The scale features an automatic switch-off to preserve the batteries. If the scale remains inactivated for 5 minutes (no alternation of the weight, no manipulation of the keys), the scale will switch-off itself. But this function can also be deactivated. Hold the UNIT key at the back of the scale pressed, while also pressing the button in order to start the scale. There will occur P-ON (power on) at the display for a short time. If you activate the scale this way, it will remain active until you switch off the scale yourself by pressing the button or until the batteries die. At the next start of the scale the AUTO Power OFF function will be active again. Thus an unintentional waste of the battery power of the scale will be avoided. 6.5. Lightening The display lights of the scale will be activated as soon as the scale is in use. If the scale is not operating, the lights will shut down after 5 seconds. This adjustment is preset and cannot be alternated. 6.6. Adjustment / Calibration The scale provides the option of a linearly adjustment. Hereby the scale is adjusted with several weights. Thus a more precise accuracy for the entire scaling range is achieved. Therefore press the key and the UNIT key at the back of the scale, hold both keys pressed while starting the scale via the key. There will occur CAL at the display. Now release the keys and the display will indicate S-20. Via the Unit - key, you can now search for the weighing range of the scale, e.g. S-150, which can then be confirmed by pressing the key. After that there will occur a number, e.g. 28353, at the display. Now you have to set the scale into the wanted calibration position and press then the key. 5

As soon as the weight, that is required for the calibration, will be indicated shortly at the display, the adequate calibration weight is to hang onto the scale. Then you have to wait until the value is stabilized. Then press and the next weight to hang on for calibration, will be indicated at the display (e.g. PCE-HS 150 shows: 40 kg / 80 kg / 120 kg and 150 kg). You have to hang each of these weights one after another onto the scale for proper calibration. Follow each step until the display indicates End. If there is written FAIL at the display, the adjustment went wrong and you are advised to repeat all adjustment steps. 6.7. HOLD function (MAX. and weighing animals) The scale supports various HOLD -functions. The HOLD-functions determine when to show a result at the display of the scale. In order to access the adjustment-options for the HOLD -function, press and hold the several HOLD-functions will be shown one after another. key, so that HOLD / ANIMAL Mode to weight animals This function allows showing moving objects Therefore the scale automatically calculates an average value out of several weights. The average value will be indicated after 6-8 seconds at the display. The average value is calculated from approx. 14-16 measurements. PEAK Indication of maximum value This function saves the maximum value at the display until that value is exceeded. This function is often used for tensile tests (500ms- 0.5 sec.). HOLD / AUTO Automatic Hold of value This function automatically freezes the value at the display, as soon as it is stable. The stability will be indicated at the left upper corner of the display as a circle. Further weighings can be performed by pressing the HOLD button. During the measuring process the HOLD symbol blinks. As soon as a stable value is reached the HOLD symbol will freeze in the middle upper area of the display and will not blink anymore. HOLD / KEY Freezing value by key press This function freezes the value at the display that is indicated during pressing the HOLD button. Therefore the value does not need to be stable. For further weighing please press the HOLD button again. 6

HOLD / AUTO / KEY HOLD by key press for stable values The value will be only frozen on the display after the HOLD key is pressed and the value on the display is stable enough. For further questions and information on calibration, please contact us: PCE Inst. In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm To implement the RoHS (redemption and disposal of electric devices) we take back our devices. They will either be recycled by us or be disposed through a recycling company according to statutory provisions. WEEE-Reg.-Nr. DE69278128 7